An amperometric biosensor with human CYP3A4 as a novel drug screening tool.

We developed a biosensor based on the redox properties of human CYP3A4 to directly monitor electron transfer to the heme protein. Enzyme films were assembled on gold electrodes by alternate adsorption of a CYP3A4 layer on top of a polycation layer. Direct, reversible electron transfer between the electrode and CYP3A4 was observed with voltammetry under anaerobic conditions. In the presence of oxygen, the oxidation peak of the hemoprotein disappeared, and the reduction peak increased 2- to 3-fold. Addition of CYP3A4 substrates (verapamil, midazolam, quinidine, and progesterone) to the oxygenated solution caused a concentration-dependent increase in the reduction current in cyclic voltammetric and amperometric experiments. Product analyses after electrolysis with the enzyme film showed catalytic activity of the biosensor depending on substrate concentration, its inhibition by ketoconazole, and a minor contribution of H(2)O(2) to the catalytic cycle. These results suggest that electron exchange between the electrode and the immobilized CYP3A4 occurred, and that metabolic activity of the enzyme was maintained. Thus, important requirements for the application of human CYP biosensors in order to identify drugs or drug candidates as substrates or inhibitors to the attached enzyme are fulfilled.

Biosensing Techniques↗

Evaluation of a miniaturized thermal biosensor for the determination of glucose in whole blood.

A miniaturized thermal biosensor has been evaluated as part of a flow-injection analysis system for the determination of glucose in whole blood. Glucose was determined by measuring the heat evolved when samples containing glucose passed through a small column with immobilized glucose oxidase and catalase. Samples of whole blood (1 microliter) can be measured directly, without any pretreatment. The correlation in the response between the thermal biosensor, the Reflolux S meter (Boehringer Mannheim), the Granutest 100 glucose test kit (Merck Diagnostica) and the Ektachem (Kodak) instrument was evaluated. The influence of the hematocrit value and of possible interferences is reported. The correlation measurements show that the thermal biosensor calibrated with aqueous glucose standards generally gives lower values on blood glucose than the reference methods calibrated for serum or blood measurements. Mean negative biases range from 0.53 to 1.16 mmol/l. Differences in sample treatment clearly complicate comparisons and the proper choice of reference method. There was no influence from substances such as ascorbic acid (0.11 mmol/l), uric acid (0.48 mmol/l), urea (4.3 mmol/l) and acetaminophen (0.17 mmol/l) on the response to 5 mmol/l glucose. The hematocrit value does not influence the glucose determination, for hematocrit values of between 13 and 53%.

Biosensing Techniques↗

Allosteric enzymes as biosensors for molecular diagnosis.

Biosensors are hybrid analytical devices that amplify signals generated from the specific interaction between a receptor and the analyte, through a biochemical mechanism. Biosensors use tissues, whole cells, artificial membranes or cell components like proteins or nucleic acids as receptors, coupled to a physicochemical signal transducer. Allosteric enzymes exhibit a catalytic activity that is modulated by specific effectors, through binding to receptor sites that are distinct from the active site. Several enzymes, catalyzing easily measurable reactions, have been engineered to allosterically respond to specific ligands, being themselves the main constituent of new-generation biosensors. The molecular basis, robustness and application of allosteric enzymatic biosensing are revised here.

Allosteric Regulation↗

Reassessment of the calibration constant for the IAsys biosensor.

A magnitude of 50 are s ng-1 mm2 has been determined for the calibration constant relating biosensor response to the amount of protein bound to the sensor surface of an IAsys cuvette. These studies entailed enzymatic assessment of the extent of lactate dehydrogenase depletion in the liquid phase arising from enzyme binding to a carboxymethyldextran-coated sensor surface, and also estimation of a maximum biosensor response for the electrostatic interaction of ovalbumin with an aminosilane-coated sensor surface. The latter results required correction for contributions to biosensor response resulting from changes in the refractive index of the liquid phase effected by high protein concentrations.

Biosensing Techniques↗

Transforming growth factor-beta (TGF-beta) binding to the extracellular domain of the type II TGF-beta receptor: receptor capture on a biosensor surface using a new coiled-coil capture system demonstrates that avidity contributes significantly to high affinity binding.

Mature TGF-beta isoforms, which are covalent dimers, signal by binding to three types of cell surface receptors, the type I, II and III TGF-beta receptors. A complex composed of the TGF-beta ligand and the type I and II receptors is required for signaling. The type II receptor is responsible for recruiting TGF-beta into the heteromeric ligand/type I receptor/type II receptor complex. The purpose of this study was to test for the extent that avidity contributes to receptor affinity. Using a surface plasmon resonance (SPR)-based biosensor (the BIACORE), we captured the extracellular domain of the type II receptor (TbetaRIIED) at the biosensor surface in an oriented and stable manner by using a de novo designed coiled-coil (E/K coil) heterodimerizing system. We characterized the kinetics of binding of three TGF-beta isoforms to this immobilized TbetaRIIED. The results demonstrate that the stoichiometry of TGF-beta binding to TbetaRIIED was one dimeric ligand to two receptors. All three TGF-beta isoforms had rapid and similar association rates, but different dissociation rates, which resulted in the equilibrium dissociation constants being approximately 5pM for the TGF-beta1 and -beta3 isoforms, and 5nM for the TGF-beta2 isoform. Since these apparent affinities are at least four orders of magnitude higher than those determined when TGF-beta was immobilized, and are close to those determined for TbetaRII at the cell surface, we suggest that avidity contributes significantly to high affinity receptor binding both at the biosensor and cell surfaces. Finally, we demonstrated that the coiled-coil immobilization approach does not require the purification of the captured protein, making it an attractive tool for the rapid study of any protein-protein interaction.

Amino Acid Sequence↗

Stress responsive bacteria: biosensors as environmental monitors.

The delicate and dynamic balance of the physiological steady state and its maintenance is well characterized by studies of bacterial stress response. Through the use of genetic analysis, numerous stress regulons, their physiological regulators and their biochemical processes have been delineated. In particular, transcriptionally activated stress regulons are subjects of study and application. These regulons include those that respond to macromolecular damage and toxicity as well as to nutrient starvation. The convenience of reporter gene fusions has allowed the creation of biosensor strains, resulting from the fusion of stress-responsive promoters with a variety of reporter genes. Such cellular biosensors are being used for monitoring dynamic systems and can report the presence of environmental stressors in real time. They provide a greater range of sensitivity, e.g. to sub-lethal concentrations of toxicants, than the simple assessment of cell viability. The underlying physiological context of the reporter strains results in the detection of bioavailable concentrations of both toxicants and nutrients. Culture conditions and host strain genotypes can be customized so as to maximize the sensitivity of the strain for a particular application. Collections of specific strains that are grouped in panels are used to diagnose targets or mode of action for unknown toxicants. Further application in massive by parallel DNA and gene fusion arrays greatly extends the information available for diagnosis of modes of action and may lead to development of novel high-throughput screens. Future studies will include more panels, arrays, as well as single reporter cell detection for a better understanding of the population heterogeneity during stress response. New knowledge of physiology gained from further studies of novel systems, or using innovative methods of analysis, will undoubtedly yield still more useful and informative environmental biosensors.

Bacteria↗

Screening of the Bacillus thuringiensis Cry1Ac delta-endotoxin on the artificial phospholipid monolayer incorporated with brush border membrane vesicles of Plutella xylostella by optical biosensor technology.

The binding of Cry1Ac, an insecticidal protein of Bacillus thuringiensis, to a brush border membrane (BBM) isolated from midguts of the diamondback moth Plutella xylostella was examined by surface plasmon resonance (SPR)-based biosensor. BBM was mixed with 1,3-ditetradecylglycero-2-phosphocholine (PC14), a neutral charged artificial lipid, and was reconstructed to a monolayer on a hydrophobic chip for the biosensor. The binding of Cry1Ac to the reconstructed monolayer was analyzed by a two-state binding model, and it was shown that Cry1Ac bound to the monolayer in the first step with an affinity constant (K(1)) of 508 nM, followed by the second uni-molecular step with an equilibrium constant (K(2)) of 0.472. The overall affinity constant K(d) was determined to be 240 nM. The binding was markedly inhibited by N-acetyl-D-galactosamine (K(i)=8 mM). The monolayer was shown to retain a high affinity to Cry1Ac, providing an insect-free system for rapid and large-scale screening of B. thuringiensis insecticidal proteins by the SPR-based biosensor technology.

Animals↗

Characterization in vitro and in vivo of the oxygen dependence of an enzyme/polymer biosensor for monitoring brain glucose.

The oxygen dependence of a first generation amperometric biosensor was investigated in vitro and in vivo by monitoring its glucose response as a function of solution pO(2). The biosensor was a glucose oxidase (GOx) modified poly(o-phenylenediamine) coated Pt cylinder electrode (Pt/PPD/GOx) that has been designed for neurochemical analysis in vivo. Two types of oxygen probes were used: a self-calibrating commercial macroelectrode in vitro; and a carbon paste microelectrode in vivo. Calibrations in vitro showed that oxygen interference in the operation of Pt/PPD/GOx electrodes was minimal for concentrations of glucose (approximately 0.5 mM) and oxygen (approximately 50 microM) found in brain ECF. This observation was confirmed by simultaneous monitoring in vivo of brain glucose and oxygen in the awake rat. However, at levels of glucose normally found in peripheral tissues (approximately 5 mM), the oxygen dependence was severe. We conclude that the oxygen sensitivity of Pt/PPD/GOx biosensors does not preclude their reliable use in media containing low glucose levels, such as brain ECF.

Animals↗

Green fluorescent protein-based biosensor for detecting SOS-inducing activity of genotoxic compounds.

Increasing levels of environmental pollution demand specific and sensitive methods for detection of genotoxic agents in water, food products and environmental samples. Tests for genotoxicity assessment are often based on biosensor strains that respond to DNA damage induced by chemicals. In the present study, fluorescent reporter Escherichia coli strains have been developed, which contain a plasmid-borne transcriptional fusion between the DNA-damage inducible recA promoter and the green fluorescent protein gene (gfp) or a gene encoding a red-shifted, higher intensity GFP variant (mutant 3). GFP-based biosensors allowed the detection of a dose-dependent response to genotoxic agents such as mitomycin C (MMC), N-methyl-N'-nitro-N-nitrosoguanidine (MNNG) and nalidixic acid (NA). A reporter strain carrying recA'-gfp mutant 3 fusion gave more dramatic and sensitive response than a strain containing the wild-type gfp. These results indicate that recA'-gfp mutant 3-based biosensor is potentially useful for detection of genotoxins.

Biosensing Techniques↗

Creatinine biosensors: principles and designs.

Creatinine biosensors, based on both potentiometric and amperometric devices, have been created. However, there are significant problems still to be addressed, including the balance between sensitivity and selectivity, interference rejection and sensor stability. In addition, many devices still rely on a dual-sensor approach for creatine and creatinine subtractive measurements. However, creatinine biosensors appear close to attaining the performance goals necessary for their widespread application. This article looks at the operating principle and design of both potentiometric and amperometric creatinine biosensors, and shows how the design of these devices affects their performance.

Aminohydrolases↗

Detection of physiologically active compounds using cell-based biosensors.

Cell-based biosensors are portable devices that contain living biological cells that monitor physiological changes induced by exposure to environmental perturbations such as toxicants, pathogens or other agents. Methods of detecting physiological changes include extracellular electrical recordings, optical measurements, and, in the future, functional genomics and proteomics. Several technical developments are occurring that will increase the feasibility of cell-based biosensors for field applications; these developments include stem cell and 3D culture technologies. Possible scenarios for the use of cell-based biosensors include broad-range detectors of unknown threat agents and functional assessment of identified agents.

Biosensing Techniques↗

Bacterial biosensors for monitoring toxic metals.

Biosensors utilize biological components to provide selectivity for monitoring compounds of environmental, clinical and industrial importance. A number of biosensors based on bacteria have recently been developed for monitoring toxic metals in the environment. The advantages and disadvantages of these types of biosensors are discussed.

Bacterial Proteins↗

Fluorescent-protein biosensors: new tools for drug discovery.

Recent improvements in target discovery and high-throughput screening have increased the pressure at key points along the drug-discovery pipeline. High-content screening was developed to ease the bottlenecks formed at the target-validation and lead-optimization points, and a new generation of reagents that report on specific molecular processes in living cells (fluorescent-protein biosensors) have been important in its development. Creative designs of fluorescent-protein biosensors have emerged and been used to measure the molecular dynamics of macromolecules, metabolites and ions. Recent applications of fluorescent-protein biosensors to biological problems have provided a foundation for their use in biotechnology.

Biosensing Techniques↗

Spectral surface plasmon resonance biosensor for detection of staphylococcal enterotoxin B in milk.

This work evaluates a newly developed wavelength modulation-based SPR biosensor for the detection of staphylococcal enterotoxin B (SEB) in milk. Two modes of operation of the SPR biosensor are described: direct detection of SEB and sandwich assay. In the sandwich assay detection mode, secondary antibodies are bound to the already captured toxin to amplify sensor response. Samples including SEB in buffer and SEB in milk were analyzed in this work. The SPR biosensor has been shown to be capable of directly detecting concentrations of SEB in buffer as low as 5 ng/ml. In sandwich detection mode, the lowest detection limit was determined to be 0.5 ng/ml for both buffer and milk samples. The reported wavelength modulation-based SPR sensor provides a generic platform which can be tailored for detection of various foodborne pathogens and agents for food analysis and testing.

Animals↗

Construction of a bacterial biosensor for styrene.

A new bacterial biosensor for styrene has been developed and characterized. A translational fusion of the lacZ gene to the sty promoter of Pseudomonas sp. strain Y2 has been inserted into miniTn5. Transposition of the recombinant transposon to the chromosome of Pseudomonas sp. strain Y2 resulted in a whole-cell biosensor able to detect and degrade styrene. In this biosensor, the endogenous StyS/StyR system detects the presence of styrene and turns on the expression of the exogenous reporter gene from the transferred construction. Other compounds such as toluene, epoxystyrene, phenylacetaldehyde and 2-phenylethanol also induced expression of beta-galactosidase although quantitative differences in their effect are clearly detected. Non-inducing compounds affect differently the sensitivity to inducing compounds when present in a mixture.

Biosensing Techniques↗

Kinetic characterization of TAR RNA-Tat peptide and neomycin interactions by acoustic wave biosensor.

The kinetics of binding of short Tat peptides and an aminoglycoside molecule to the human immunodeficiency virus-type 1(HIV-1) TAR RNA and to a bulge mutant analogue (MTAR) is studied in a biosensor format by monitoring the time course of the response in a series resonance frequency, using an acoustic wave biosensor. Association and dissociation rate constants are evaluated by fitting the experimental data to a simple 1:1 (Langmuir) model. Kinetic rate and equilibrium dissociation constants show that MTAR-peptide complexes are subject to a higher dissociation rate and are less stable compared to the corresponding TAR-peptide complexes. In addition, longer peptides display enhanced discrimination ability than a shorter peptide according to the equilibrium dissociation constants evaluated using this technique. K(D) values for TAR-Tat vs. MTAR-Tat complexes are 2.6 vs. 3.8 microM for Tat-12, 0.87 vs. 4.3 microM for Tat-18 and 0.93 vs. 1.6 microM for Tat-20. The equilibrium dissociation constant for TAR-neomycin complex is 12.4 microM and it is comparable to the values obtained from non-biosensor type assays. These findings are in parallel with those cited in the literature and the results from this study underline the potential of the acoustic wave sensor for detailed biophysical analysis of nucleic acid-ligand binding.

Acoustics↗

An electrochemical multienzymatic biosensor for determination of cholesterol.

This paper describes an electrochemical biosensor for free cholesterol monitoring. The sensor is a multienzymatic electrodic system in which horseradish peroxidase and cholesterol oxidase are simultaneously immobilized within a polymeric film, on the surface of a pyrolitic graphite electrode. From voltammetric and amperometric (flow-injection) data obtained, the efficiency, reproducibility and stability of the system are discussed. Results obtained, of interest for basic and applied biochemistry, represent a first step for construction of a mediator-free biosensor with potentialities for a successful application in the biosensor area.

Biosensing Techniques↗

A kinetic study of analyte-receptor binding and dissociation for biosensor applications: a fractal analysis for two different DNA systems.

A fractal analysis of DNA binding and dissociation kinetics on biosensor surfaces is presented. The fractal approach provides an attractive, convenient method to model the kinetic data taking into account the effects of surface heterogeneity brought about by ligand immobilization. The fractal technique can be used in conjunction or as an alternate approach to conventional modeling techniques, such as the Langmuir model, saturation model, etc. Examples analyzed include a DNA molecular beacon biosensor and a plasmid DNA-(cationic polymer) interaction biosensor. The molecular beacon example provides some insights into the nature of the surface and how it influences the binding rate coefficients. The DNA-cationic polymer interaction example provides some quantitative results on the binding and dissociation rate coefficients. Data taken from the literature may be modeled, in the case of binding, using a single-fractal analysis or a dual-fractal analysis. The dual-fractal analysis results indicate a change in the binding mechanism as the reaction progresses on the surface. A single-fractal analysis is adequate to model the dissociation kinetics in the example presented. Relationships are presented for the binding rate coefficients as a function of their corresponding fractal dimension, D(f), which is an indication of the degree of heterogeneity that exists on the surface. When analyte-receptor binding is involved, an increase in the heterogeneity of the surface (increase in D(f)) leads to an increase in the binding rate coefficient.

Biosensing Techniques↗