PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “spatial dependency”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35Linked to original sources

Active motion of polymorphonuclear leukocytes in response to chemoattractant in a micropipette.

A novel experimental method of producing and observing the active motion of polymorphonuclear leukocytes (PMNs) using a micropipette technique has been recently developed (Usami et al., 1992). The present paper develops a quantitative theory for the chemoattractant gradients and cell locomotion observed in these experiments. In previous experimental methods (e.g., the Boyden chamber, the Zygmond chamber and the Dunn chamber) for study chemotaxis of leukocytes, fibroblasts, and PMNs, the exact nature of the concentration gradient of the chemoattractant is unknown. The cells may themselves modify the local gradient of the chemoattractant. In experiments using the micropipette, an internal source of chemoattractant provides well-defined boundary and initial conditions which allow the computation of the chemoattractant concentration gradient during the active locomotion of the PMNs. Since the cell completely fills the pipette lumen, convection is limited to the motion of the cells themselves. In coordinates moving with cell, it is assumed that diffusion is the only mechanism of mass transport of the chemoattractant (fMLP). Computations of the fMLP concentration during locomotion of the cell were carried out for a range of rates of fMLP binding by the receptors expressed on the front face of the cell membrane. The results show that the front face of the cell is subjected to increasing fMLP concentration during the cell motion. The sequence of events involve receptor binding of fMLP, signal transduction, polymerization of the cell cytoskeleton at the membrane of the front face, spatially dependent adhesion to the pipette wall, and localized contraction of the cytoskeleton. This sequence of events leads to the steady locomotion of the leukocytes in the micropipette. The computation of the distribution of the fMLP concentration during cell locomotion with constant velocity in micropipette experiments shows that the cell is exposed to increasing concentration of fMLP. This suggests that chemotaxis maybe induced by temporal gradient of an attractant.

Cell Movement↗

Development and characterization of a tissue equivalent plastic scintillator based dosimetry system.

High precision techniques in radiation therapy, such as intensity modulated radiation therapy, offer the potential for improved target coverage and increased normal tissue sparing compared with conformal radiotherapy. The complex fluence maps used in many of these techniques, however, often lead to more challenging quality assurance with dose verification being labor-intensive and time consuming. A prototype dose verification system has been developed using a tissue equivalent plastic scintillator that provides easy-to-acquire, rapid, digital dose measurements in a plane perpendicular to the beam. The system consists of a water-filled Lucite phantom with a scintillator screen built into the top surface. The phantom contains a silver coated plastic mirror to reflect scintillation light towards a viewing window where it is captured using a charge coupled device camera and a personal computer. Optical photon spread is removed using a microlouvre optical collimator and by deconvolving a glare kernel from the raw images. A characterization of the system was performed that included measurements of linear output response, dose rate dependence, spatial linearity, effective pixel size, signal uniformity and both short- and long-term reproducibility. The average pixel intensity for static, regular shaped fields between 3 cm X 3 cm and 12 cm x 12 cm imaged with the system was found to be linear in the dose delivered with linear regression analysis yielding a correlation coefficient r2 > 0.99. Effective pixel size was determined to be 0.53 mm/pixel. The system was found to have a signal uniformity of 5.6% and a long-term reproducibility/stability of 1.7% over a 6 month period. The system's ability to verify a dynamic treatment field was evaluated using 60 degrees dynamic wedged fields and comparing the results to two-dimensional film dosimetry. Results indicate agreement with two-dimensional film dosimetry distributions within 8% inside the field edges. With further development, this system promises to provide a fast, directly digital, and tissue equivalent alternative to current dose verification systems.

Biomimetic Materials↗

Phase and sensitivity of receiver coils in magnetic resonance imaging.

Receiver coil response is a major cause of nonuniformities in magnetic resonance images. The spatial dependence of the sensitivity and phase of single-saddle receiver coils has been investigated quantitatively by calculating the H1 field and comparing the results with measurements of a uniform phantom. Agreement between the measurements and calculations is excellent. A method is developed which corrects for both the nonuniform sensitivity and the phase shifts introduced by receiver coils.

Humans↗

Thermodynamics of movable inductively heated seeds for the treatment of brain tumors.

A thermodynamic study is presented of temperature distributions created by an inductively heated 6-mm-diam Ni sphere imbedded in vivo and in vitro into porcine brain tissue. This study was performed in support of the development of a system that creates localized heat-induced lesions in deep-seated brain tumors. In this system, a magnetic "seed" will be remotely repositioned within the brain by an externally produced magnetic field. Convective effects of a hot moving seed will produce a different thermodynamic situation than that arising from an array of static implants. In this work, a study is presented of part of the expected change, in which a static sphere is heated to high temperature. Measurements were made of the temporal and spatial dependence of the temperature rise in the vicinity of the heated sphere, in vivo in four animals and in one that was euthanized immediately prior to experimentation. These results are used for parameter estimation with a theoretical model based on a point source solution to a form of the thermal diffusion equation, i.e., the "bioheat transfer equation." With this model thermal distributions from a power source of arbitrary geometry can be found using appropriate integration methods, and the method has widespread applicability. Estimates of blood flow rates, tissue thermal conductivity, and seed power absorption were found using the parameter estimation algorithm. The estimated blood perfusion exhibits a step increase following the first heating in multiple heating experiments. Thermal conductivity estimated using data from the nonperfused (in vitro) animal is 0.6 W/m degrees C. Seed power absorption is estimated correspondingly to be 0.9 W, a result confirmed independently with calorimetry. Statistical uncertainty is established for the radial decrease of the tissue temperature rise created by this method. This result allows estimation of a cell death boundary uncertainty of 0.6 mm, caused by fluctuations in power delivered to the seed, uncertainty in the temperature probe placements, and thermal properties such as blood perfusion and tissue thermal conductivity.

Animals↗

Differential attenuation method for simultaneous estimation of activity and attenuation in multiemission single photon emission computed tomography.

A penalized weighted least squares reconstruction algorithm is described that simultaneously estimates activity and attenuation distributions from emission sinogram data alone. This estimation technique is based on differential attenuation information and is applicable to any single photon emission computed tomography imaging isotope with emissions at two or more distinct energies, after accurate compensation for Compton scatter. A rotation-based forward projector is used to efficiently model photon attenuation at multiple emission energies, as well as distance-dependent spatial resolution. The algorithm was tested using simulated scatter-free 201T1 projection data from a single-slice numerical cardiac phantom with and without cold myocardial defects. Poisson noise was added to the projection data to mimic clinically realistic count densities. The activity estimates resulting from the proposed method had fewer artifacts and were substantially more accurate than images reconstructed with filtered backprojection without compensation for attenuation. Several techniques were employed to reduce the time required for the iterative routine to converge and to reduce the sensitivity of the solution to noise in the projection data. These included: (1) a preconditioning image variable transformation; (2) a coarse-to-fine grid initialization schedule; and (3) a convex hull image mask determined directly from the data. The combined effect of these techniques substantially reduced the compute time required for the reconstruction.

Algorithms↗

Resonant response of complex shell structures

Resonances of shell structures play a prominent role in determining their acoustic characteristics. Among the most important of such characteristics are radiated noise, scattering, and self-noise levels. The nature of the structural resonances, for example the number of modes within a particular frequency band or the overall spatial dependence of the response, determines the importance of these phenomena in various contexts and what steps may be taken to modify their acoustic impact. In the past, knowledge of the resonant response of highly idealized systems has been used to guide the development of quiet platforms. The results of a scale model investigation of the effects of increased complexity on the nature of the resonances of submerged shell structures are reported. Effects presented here are flexural Bloch mode resonances, localized resonances resulting from structural irregularity, and the effects of non-axisymmetry on these phenomena. The implications of these results on acoustic design and the development of systems is discussed.

Journal Article↗

Modeling vibrational energy transmission at bolted junctions between a plate and a stiffening rib.

An analytical model is presented for structure-borne sound transmission at a bolted junction in a rib-stiffened plate structure. The model is based on the wave approach for junctions of semi-infinite plates and calculates coupling loss factors required by statistical energy analysis. The stiffening rib is modeled as a plate strip and the junction is represented by an elastic interlayer with a spatially dependent stiffness. Experimental verification is carried out on a series of Plexiglas plate structures with varying rib depth and bolt spacing. A well-defined connection length at the junction was created by inserting thin spacers between the plate and the rib at each bolt. Comparison between numerical and experimental data for this case showed good agreement. Measured results for the bolted junction without spacers suggested that structure-borne sound transmission could be modeled as a series of connections characterized by a finite connection length. This concept is explored further by determining an equivalent connection length which gives the best agreement between numerical and experimental data.

Journal Article↗

Aberration correction for time-domain ultrasound diffraction tomography.

Extensions of a time-domain diffraction tomography method, which reconstructs spatially dependent sound speed variations from far-field time-domain acoustic scattering measurements, are presented and analyzed. The resulting reconstructions are quantitative images with applications including ultrasonic mammography, and can also be considered candidate solutions to the time-domain inverse scattering problem. Here, the linearized time-domain inverse scattering problem is shown to have no general solution for finite signal bandwidth. However, an approximate solution to the linearized problem is constructed using a simple delay-and-sum method analogous to "gold standard" ultrasonic beamforming. The form of this solution suggests that the full nonlinear inverse scattering problem can be approximated by applying appropriate angle- and space-dependent time shifts to the time-domain scattering data; this analogy leads to a general approach to aberration correction. Two related methods for aberration correction are presented: one in which delays are computed from estimates of the medium using an efficient straight-ray approximation, and one in which delays are applied directly to a time-dependent linearized reconstruction. Numerical results indicate that these correction methods achieve substantial quality improvements for imaging of large scatterers. The parametric range of applicability for the time-domain diffraction tomography method is increased by about a factor of 2 by aberration correction.

Breast↗

Statistical-acoustics models of energy decay in systems of coupled rooms and their relation to geometrical acoustics.

An improved statistical-acoustics model of high-frequency sound fields in coupled rooms is developed by incorporating into prior models geometrical-acoustics corrections for both energy decay within subrooms and energy transfer between subrooms. The conditions under which statistical-acoustics models of coupled rooms are valid approximations to geometrical acoustics are examined by comparison of computational geometrical-acoustics predictions of decay curves in two- and three-room systems with those of both improved and prior statistical-acoustics models. The accuracy of the decay model used within subrooms is found to have a primary influence on the accuracy of predictions in coupled systems. Likewise, nondiffuse transfer of energy is shown to significantly affect decay of energy in systems of coupled rooms. The decrease in energy density of the reverberant field with distance from the source, which is predicted by geometrical acoustics, is found to result in spatial dependence of decay-curve shape for certain coupling geometries. Geometrical effects are shown to contribute to the failure of statistical-acoustics models in the case of strong coupling between subrooms; thus, previously proposed statistical-acoustics criteria cannot predict the point at which the models break down with consistent accuracy.

Acoustics↗

On the stability of the effective apodization of the nonlinearly generated second harmonic with respect to range.

The concept of an effective apodization was introduced to describe the field pattern for the nonlinearly generated second harmonic (2f) within the focal zone using a linear propagation model. Our objective in this study was to investigate the validity of the concept of an effective apodization at 2f as an approach to approximating the field of the second harmonic over a wide range of depths. Two experimental setups were employed: a vascular imaging array with a water path and an adult cardiac imaging array with an attenuating liver path. In both cases the spatial dependencies of the ultrasonic fields were mapped by scanning a point-like hydrophone within a series of planes orthogonal to the propagation direction. The sampling distances were located before, within, and beyond the focal zone. The signals were Fourier transformed and the complex values at 2f were linearly backpropagated to the transmit plane in order to obtain an effective apodization. The measured results demonstrated a relatively constant effective apodization at 2f as a function of propagation distance. Finite amplitude computer simulations were found to be in agreement with these measurements. Thus the measure of the effective apodization at 2f provides an approximation to the second harmonic field outside the focal zone.

Acoustics↗

The combination of echolocation emission and ear reception enhances directional spectral cues of the big brown bat, Eptesicus fuscus.

The acoustic information used by bats is produced by a combination of the properties of the sound emission and the reception at the eardrum. The potential localization cues used by bats can only be fully revealed when the magnitude spectra of the emission and the external ear are convolved to produce the echolocation combination magnitude spectra. The spatially dependent changes in the magnitude spectra of the echolocation combination of Eptesicus fuscus are described. The emission and external ear magnitude spectra act together to enhance the potential localization cues. In the echolocation combination, the spectral peaks are sharpened and there is greater contrast in intensity between peaks and notches when compared to the spectra of the ear alone. The spectral localization cues in the echolocation combination appear to be restricted to a cone of space of approximately +/-30 degrees.

Animals↗

A backpropagation network model of the monaural localization information available in the bat echolocation system.

The information echolocating bats receive is a combination of the properties of the sound they emit and the sound they receive at the eardrum. Convolving the emission and the external ear transfer functions produces the full spectral information contained in the echolocation combination. Spatially dependent changes in the magnitude spectra of the emission, external ear transfer functions, and the echolocation combination of Eptesicus fuscus could provide localization information to the bat. Principal component analysis was used to reduce the dimensionality of these complex spectral data sets. The first eight principal component weights were normalized, rotated, and used as the input to a backpropagation network model which examined the relative directionality of the emission, ear, and the echolocation combination. The model was able to localize more accurately when provided with the directional information of the echolocation combination compared to either the emission or ear information alone.

Animals↗

A fast method for acoustic imaging of multiple three-dimensional objects.

This paper is concerned with the inverse problem for imaging multiple three-dimensional objects using the information of the far-field pattern of the scattered wave. A spatially dependent function, which has noticeably different values inside and outside the obstacle, is derived. A numerical method based on the characterization is developed to obtain a visualization of the obstacle. The most remarkable advantage of this method is that it does not need any prior knowledge about the geometry and physical properties of the scatterer, and requires only the information of the far-field measurements for a finite number of directions of incidence and observation distributed over a limited range. Furthermore, the scheme is very simple and fast since it avoids the use of the iterative procedure and requires only the solution of a linear system. Some numerical examples with synthetic far-field data are given showing the practicality and efficiency of this scheme.

Acoustics↗

More is less: neurogenesis and age-related cognitive decline in Long-Evans rats.

A reduction in the ability to generate new neurons in the brain has been suggested to contribute to cognitive decline with advanced age. In an outbred model strain of Long-Evans rats, cognitive performance as a function of age is variable in assessments of hippocampal-dependent spatial memory. Recent research indicates that greater hippocampal neurogenesis accompanies diminished cognitive abilities in older Long-Evans rats. These findings imply that the role of neurogenesis might change between youth and old age, and that further work is needed to understand the potential benefits and liabilities that new neurons may afford an aging brain.

Age Factors↗

Localization of metastable atom beams with optical standing waves: nanolithography at the heisenberg limit

The spatially dependent de-excitation of a beam of metastable argon atoms, traveling through an optical standing wave, produced a periodic array of localized metastable atoms with position and momentum spreads approaching the limit stated by the Heisenberg uncertainty principle. Silicon and silicon dioxide substrates placed in the path of the atom beam were patterned by the metastable atoms. The de-excitation of metastable atoms upon collision with the surface promoted the deposition of a carbonaceous film from a vapor-phase hydrocarbon precursor. The resulting patterns were imaged both directly and after chemical etching. Thus, quantum-mechanical steady-state atom distributions can be used for sub-0.1-micrometer lithography.

Journal Article↗

Numerical study of the flow around a cylinder using multi-particle collision dynamics.

A novel mesoscopic simulation technique--multi-particle collision dynamics--which has been suggested very recently, is used to study the two-dimensional flow around a square and a circular cylinder. The method is described and new proper boundary conditions are proposed to deal with wall collisions. The flow is analyzed in a wide range of Reynolds numbers in order to cover both the steady and unsteady regimes, resulting in symmetric steady vortices and periodic vortex shedding, respectively. The numerical results for integral flow parameters, such as the recirculation length, the drag and lift coefficients, the Strouhal number, as well as the spatial dependence of the velocity field, are compared with previous numerical and experimental studies. The qualitative and quantitative agreement is very good, validating the method as a promising technique to describe the hydrodynamic effects of solvent on embedded particles.

Journal Article↗

Single-exposure dual-energy computed radiography: improved detection and processing.

Recent reports have emphasized the potential for dual-energy computed radiographic applications. An improved method for single-exposure material-selective imaging with a photostimulable phosphor computed radiography system was investigated. The essential elements of the technique are (a) prefiltration with gadolinium, which divides the incident broad-beam x-ray spectrum into low-energy and high-energy peaks; (b) a cassette consisting of four photostimulable phosphor plates that record images of increasing mean energies, with a computed energy separation of 23 keV from the front to the rear plate; (c) spatially dependent scatter and beam-hardening corrections; and (d) a noise-reduction algorithm based on noise correlations between bone-selective and soft-tissue-selective dual-energy images. These elements result in improved material cancellation and signal-to-noise ratio throughout the image.

Algorithms↗

Virtual-space receptive fields of single auditory nerve fibers.

1. Sounds reaching the tympanic membranes are first modified by the acoustic properties of the torso, head, and external ear. For certain frequencies in the incident sound there results a complex, direction-dependent spatial distribution of sound pressure at the eardrum such that, within a sound field, localized areas of pressure maxima are flanked by areas of pressure minima. Listeners may use these spatial maxima and minima in localizing the source of a sound in space. The results presented describe how information about this spatial pressure pattern is transmitted from the cochlea to the central auditory system via single fibers of the auditory nerve. 2. Discharges of single fibers of the auditory nerve were studied in Nembutal-anesthetized cats [characteristic frequencies (CFs) ranged from 0.4 to 40 kHz]. Click stimuli were derived from sound-pressure waveforms that were generated by a loudspeaker placed at 1,800 locations around the cat's head and recorded at the tympanic membrane with miniature microphones. Recorded signals were converted to acoustic stimuli and delivered to the ear via a calibrated and sealed earphone. The full complement of signals is referred to as "virtual acoustic space," and the spatial distribution of discharges to this array of signals is referred to as a "virtual-space receptive field" (VSRF). 3. Fibers detect both pressure maxima and pressure minima in virtual acoustic space. Thus VSRFs take on complex shapes. 4. VSRFs of fibers of the same or similar CF having low spontaneous rates had the same overall pattern as those from high-spontaneous rate (HSR) fibers. For HSR fibers, the VSRF is obscured by the high background spike activity. 5. Comparison of the VSRF and isolevel contour maps of the stimulus derived at various frequencies revealed that auditory nerve fibers most accurately extract spectral information contained in the stimulus at a frequency close to or slightly higher than CF.

Animals↗