PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Angiography, Digital Subtraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

[Intra-arterial digital subtraction angiography (IADSA) in liver metastases].

From Dec. 1988 to Dec. 1990, fifty cases of metastatic liver tumors were examined with IADSA. The present article analysed the DSA imaging in this series and divided the DSA appearances of the tumor vessels into five types: 1. Dilatation and enlargement, 29 cases (58%); 2. Stricture and narrowing, 17 cases (34%); 3. Zigzag and tangle, 39 cases (78%); 4. Intermittence and discontinuance, 20 cases (40%); 5. Removement and encirclement, 34 cases (68%). Sometimes several types could be found in one case. There were two cases in this group without any tumor vessels. The DSA appearances of tumor stains were also divided into four types: 1. Circular, cystiform and honeycomb-like, 9 cases (18%). 2. Nodular masses, 13 cases (26%). 3. Spots and flakes, 8 cases (16%). 4. Wadding-like, 15 cases (30%). There were 5 cases without any tumor stains. In no case there was AVM or cancerous embolus in portal vein. In this series, hypervascular lesions were observed in 17 cases (34%), midvascular lesions in 25 cases (50%), and hypovascular lesions in 8 cases (16%).

Adult↗

Intravenous digital subtraction angiography of the internal jugular veins.

92 patients with various head-related symptoms were underwent study with IV-DSA. The width and density of the internal jugular veins were compared with the width and density of the common carotid arteries. The right internal jugular vein was more than twice as broad as the common carotid artery in 58 patients (63%), and was denser than the common carotid artery in 14 patients (15%). On the other hand, the left internal jugular vein was broader than the common carotid artery in 76 patients (83%) and more than twice as broad as the common carotid artery in 19 patients (21%). However, the left jugular vein was narrower than the common carotid artery in 12 patients (13%), and in 5 patients (5%) could not be demonstrated. If it is recalled that the internal jugular veins are sometimes congenitally aplastic or hypoplastic as developmental variations of the confluence of sinuses, the occurrence of complications associated with retrograde catheterization can be minimized.

Adolescent↗

[Digital subtraction angiography in lower extremity phlebography].

DSA was applied to the lower extremity phlebography on 21 cases (36 legs). The patient lay in the supine position and a tourniquet was placed around the ankle. Forty ml of contrast medium, diluted to 25% of the original concentration with normal saline, was injected into the dorsal vein of the foot. The anterior tibial vein, posterior tibial vein, peroneal vein and muscular vein of the calf were identified in 24 (63.2%), 36 (94.7%), 37 (97.4%) and 7 legs (18.4%), respectively. The poor opacification of the anterior tibial vein was attributed partly to the compression effect of the tourniquet. The abnormal findings were deep vein thrombosis (5 legs), reflux from the deep to the superficial vein (14 legs) and irregularity of the venous wall (16 legs). The superficial varicose veins were not demonstrated in DSA phlebography. The examination was comfortable because the patient position was supine and the dilute contrast medium caused no burning sensation. We believe that DSA phlebography is a safe and useful method for diagnosing the deep venous system disorders.

Adult↗

[Studies of image quality and dose in digital subtraction angiography].

METHODS: The dose needed for high image quality in l.a. DSA, was determined by investigation of the necessary relationship between dose and image quality. This method is based on measurements of the signal-to-noise ratio and of the contrast-detail detectability. It has been tested on two different systems (Philips integris V3000, Philips Diagnost 97). RESULTS: Our measurements prove that an image intensifier entrance dose of 1.1 microGy (image intensifier diameter 38 cm) is sufficient for high image quality in DSA. An increased dose value does not lead to an improvement in image information. For details larger than the pixel size the 512 matrix produces a higher signal-to-noise ratio with a higher contrast-detail detectability, whereas higher spatial resolution results by the use of a 1024 matrix. In rotational angiography, high image quality can be achieved at an image intensifier entrance dose of 1.1 microGy. In contrast to sequences without rotation, image quality is decreased through movement unsharpness. As the maximum exposure time 25 ms should be selected. The use of a 1024 matrix does not lead to a better spatial resolution in rotational angiography.

Angiography, Digital Subtraction↗

Digital subtraction angiography in the diagnosis of congenital heart diseases: analysis of 60 cases.

Ninety-one IVDSA and/or IADSA examinations with 192 injections were performed in 60 patients with congenital heart disease (CHD), including 31 anatomic anomalies. Axial projection was used in 23 patients. Analysis of the results of this series showed that accurate diagnosis by DSA confirmed by cardiac surgery together with definite diagnosis by DSA were obtained in 54 cases (90%). Two cases of nondiagnosis by DSA resulted from a suboptimal DSA method; four cases of partially accurate or mistaken diagnosis determined by cardiac surgery occurred because the axial view was not used and/or the anomalies were too small to be visualized by DSA. To increase the diagnostic accuracy of DSA in CHD, an optimal method of DSA must be selected according to the position of the anomaly and the hemodynamic data, and the axial view should be used to visualize the anomaly clearly in complex cases. In addition, DSA may fail to define a mild anomaly because of its lower spatial resolution.

Adolescent↗

Evaluation of the anterior ethmoidal artery by 3D dual volume rotational digital subtraction angiography and native multidetector CT with multiplanar reformations. Initial findings.

Our purpose is to codify the anterior ethmoidal artery (AEA) course and its relationship with adjacent structures. Twenty patients with cerebrovascular disease underwent selective internal carotid dual volume angiography. Fusion of the vascular and bony images was obtained successively on a second console. MDCT of the cranium was performed in all patients. To identify the AEA course, multiplanar CT reformations were obtained. In all cases the entry-point of AEA and its course were identified by means of dual volume angiography. The information was confirmed by MDCT. In a second phase, we studied another 78 patients affected by inflammatory disease and polyposis only by means of MDCT, in order to confirm the previous data obtained by comparison between angiography and MDCT. In this second phase, 110/156 vessels were indirectly detected by means of visualization of the ethmoidal entry point. In the remaining cases, AEA was directly shown due to integrity of the thin ethmoidal bone lamellae or bony canal. Dual volume angiography is essential to identify the course of the AEA (standard of reference for the interpretation of CT). In patients with benign rhinosinusal pathology, where invasivity techniques are not justified, MPR reconstructions were of pivotal importance in the evaluation of the course of the artery with particular reference to its relationship with the frontal recess.

Adult↗

Iodixanol in abdominal digital subtraction angiography. A randomized, double-blind, parallel trial with iodixanol and iohexol.

The safety, tolerability and efficacy of iodixanol 270 mg I/ml were compared to those of iohexol 300 mg I/ml in a double-blind, randomized, parallel abdominal intra-arterial DSA phase III trial. Fifty-nine patients were included in the trial; 39 patients received iodixanol and 20 received iohexol. The mean volume of iodixanol administered was 235.8 ml (0.93 g I/kg b.w.) while the mean volume of iohexol was 254.7 ml (1.10 g I/kg b.w.). No differences in diagnostic information and radiographic density were apparent in spite of the difference in the concentration of iodine. No serious adverse events occurred. Four patients (10%) in the iodixanol group and 2 (10%) in the iohexol group experienced adverse events. Eight percent of the injections of iodixanol promoted discomfort, compared to 12% of the injections of iohexol. An increase in S-urea and S-creatinine was seen with both agents the first day after injection, but appeared to be less pronounced with iodixanol than with iohexol. Other serum tests revealed no changes of clinical importance. Both iodixanol and iohexol were found to be effective, safe and well tolerated contrast media for abdominal intra-arterial DSA.

Abdomen↗

Imaging of a parapharyngeal hemangiopericytoma. Radioimmunoscintigraphy (SPECT) with indium-111-labeled anti-CEA antibody, and comparison to digital subtraction angiography, computed tomography, and immunohistochemistry.

A 27-year-old male patient with a parapharyngeal hemangiopericytoma was investigated radiologically with orthopantomography, computed tomography, and digital subtraction angiography before the operation. Because a malignancy was suspected, the patient was imaged with gamma camera using radiolabeled monoclonal anticarcinoembryonal antigen antibody including single photon emission computed tomography. The radioantibody accumulated strongly into the neoplasm. Tumor to background ratio was 2.2. Samples of the excised tumor were stained immunohistochemically for desmin, vimentin, muscle actin, cytokeratin, CEA (carcinoembryonic antigen), and factor VIII. They showed that the antibody uptake was of unspecific nature and not due to CEA expression in the tumor.

Adult↗

[Incidence of local complications after heart catheter studies and their imaging with intravenous digital subtraction angiography: a retro- and prospective study].

Frequency of local complications following punction of the femoral artery aimed to cardiac catheterisation has been checked with 1051 patients retrospectively as well as 300 patients prospectively. Intravenous DSA was carried out when symptoms like stenotic murmurs, pulsations, hematoma, swelling or resistance within the concerned inguinal region appeared with suspicion diagnose of pseudoaneurysm, arteriovenous fistula or any other complications of vessels. The retrospective study reviewed a rate of complications of 1.62% and the prospective study a rate of 2.7%. The study reviewed that by using of DSA-checkings during a time period of 4 up to 10 month later no rest aneurysm or AV-fistula could be proved. That means a spontaneous thrombose took place with patients without operation indication. Significant connections were found between clinical pathological findings next to the position of punction and the occurrence of local complications. The single symptoms like stenotic murmurs or large hematoma are statistically proved indications to a complication of vessel. There is no connection between findings like pseudoaneurysm or AV-fistula and small hematomas next to the punction position. The intravenous DSA has been proved as easy and proof method with a small quantity of complications for the inclusion and differentiation of local complications following punction of the artery femoral.

Adult↗

[Postoperative digital subtraction angiography after infrainguinal bypass operation].

Bypass occlusions in infrainguinal arterial reconstructions occur in up to 20% within the first postoperative month and are caused by technical defects in most cases. In a prospective study to evaluate the importance of imaging techniques in infrainguinal bypass grafting 81 of 103 bypasses were examined by intraarterial DSA 10 days postoperatively. The findings of early postoperative DSA were compared with the results of intraoperative angioscopy and completion angiography. In 11 cases (13.6%) there were additional pathological findings. In 6 patients stenoses were localized at the proximal anastomosis, which could not be visualized intraoperatively due to technical reasons. In 2 more patients postoperative DSA revealed an occlusion of the distal segment of the recipient artery with a retrograde blood flow in the proximal segment. Further pathological findings were one perianastomotic stenosis caused by a thrombus at a venous valve site and one arteriovenous fistula in an in-situ-bypass. In one more patient angiography showed a stenosis in the outflow tract. The duplex-derived PSV, however, was normal and no revision was made. At present, examination of the proximal anastomosis is possible by intraoperative DSA, but initially unrecognized and secondary bypass defects can only be identified by early postoperative DSA in asymptomatic patients. A final scrutiny of the arterial reconstruction can be achieved by postoperative DSA without any recognizable morbidity before subsequent bypass function is monitored by non invasive methods like duplex sonography.

Adult↗

Duplex ultrasonography, digital subtraction angiography, and conventional angiography in assessing carotid atherosclerosis.

We prospectively compared duplex ultrasonography with digital subtraction angiography (DSA) and conventional angiography in the evaluation of carotid atherosclerosis by studying 494 arteries. Arteries were graded independently as normal, mildly stenotic, moderately stenotic, severely stenotic, or occluded. There was absolute agreement between duplex ultrasonography and DSA as to disease severity in 296 (68%) of 434 vessels, good correlation in an additional 119 vessels (28%), and poor correlation in 19 vessels (4%). When duplex studies were compared with conventional angiograms, the correlations were similar: absolute for 60 (71%) of 85 vessels, good for 17 (20%) of 85 vessels, and poor for eight (9%) of 85 vessels. With conventional angiography as the standard, duplex studies tended to overestimate the severity of disease in 64% of vessels and underestimate it in 36%, v 28% and 72%, respectively, for DSA. We concluded that duplex ultrasonography is as accurate as DSA in assessing carotid bifurcation atherosclerosis. The tendency of DSA to underestimate disease severity may lead to diagnostic errors in patients with nonobstructive plaques.

Carotid Artery Diseases↗

Velocity measurement based on bolus tracking with the aid of three-dimensional reconstruction from digital subtraction angiography.

The problem of blood flow measurement in x-ray angiography using measurements of the leading edge of the contrast bolus as it traverses the vascular bed is considered. A new technique for velocity measurement is presented based upon the ratio of the temporal derivative to the spatial derivative of the contrast bolus in the direction of flow. With the addition of a small correction factor, the value obtained is shown to reflect the transport velocity, or the velocity at which the contrast is transported down the vessel of interest. Most blood flow measurements based on bolus tracking techniques are actually using the contrast transport velocity to represent the blood flow velocity. Because of the streaming that occurs due to laminary flow conditions, the measured transport velocity is found to be somewhere between the average and the peak (central) fluid velocities for measurements taken during the traversal of the bolus leading edge. The spatial and temporal variation of the transport velocity are found to be consistent with the bolus motion expected in the presence of laminar flow. From x-ray images of contrast passage through simple tubes, we find that the derivative method measures the transport velocity during passage of the bolus leading edge. In most cases of laminar blood flow, the leading edge transport velocity can be 20%-40% higher than the average blood velocity.

Angiography, Digital Subtraction↗

[Digital subtraction angiography of the extremities using step-translation technique].

PURPOSE: To evaluate, how routine application of i.a. DSA with the step-translation technique using a single contrast bolus can effectively reduce radiation exposure and the amount of contrast media in comparison to standard peripheral DSA. METHOD/MATERIALS: 100 patients with peripheral arterial occlusive disease were assessed with step-translation DSA, 100 with standard DSA using the same equipment. Imaging quality was rated two observers, judgement by consensus. Comparison of the technical data (radiation dose, contrast media) was based on pairs of patients with similar constellations of stenoses to reduce selection bias. RESULTS: Step-translation DSA was of high imaging quality from the iliac vessels to the popliteal artery. In the distal leg, imaging was often impaired by effects like unilaterally delayed contrast flow due to high grade stenosis or motion artifacts. 53% of the step translation DSA required 1 or 2, 29% more than two additional DSA runs. Including the additional runs, the average radiation exposure and the amount of contrast media (2434 cGycm2/128 ml) were comparable to those of standard DSA (2461 cGycm2/144 ml). CONCLUSIONS: Step-translation DSA provides high quality images. In routine application realization of the advantages over standard DSA such as reduction of examination times, radiation exposure and amounts of contrast media may be impaired by poorly collateralized stenoses or motion artifacts demanding additional series.

Aged↗

[Intraarterial digital subtraction angiography (i.a. DSA) of the lower limb using fine needle technique].

PURPOSE: Severe peripheral arterial occlusive disease (pAOD) requires adequate diagnostic imagery of poststenotic and postocclusive vascular regions. This study was designed to evaluate the validity of i.a. DSA using fine-needle technique (FNA) especially concerning the vascular area of the lower limb. MATERIAL AND METHODS: 206 FNA of the lower limb wer evaluated retrospectively. Besides evaluation of the image quality of the 1119 angiographic image series, main points of interest were the determination of accuracy of the FNA in comparison to the operative findings, the average radiocontrast agent consumption and the rate of complication. RESULTS: In all cases the image quality was rated either very good or good in the pelvic, femoral and popliteal vessels. 94% of the image series of the lower leg and foot could be rated as well as very good/good although 75% of all patients demonstrated an advanced stage of pAOD. Accuracy of FNA compared to operative findings came up to 82%. The average radiocontrast consumption amounted to 69 ml per examination. Overall, two major complications were seen. CONCLUSION: I.a. DSA of the lower limb using fine-needle-technique is an easily applied angiographic method of low radiocontrast agent consumption and a low complication rate. Essential information can be acquired preoperatively in planning far peripheral bypass anastomoses. Postoperative vascular complications can be safely assessed.

Angiography, Digital Subtraction↗

[Evaluation of anastomosis between intrahepatic or extrahepatic vessels by intra-arterial digital subtraction angiography using carbon dioxide].

Carbon dioxide (CO2) intraarterial subtraction angiography (IADSA) was performed in 31 patients with various hepatobiliary diseases. The injection sites of CO2 were proper hepatic artery (10/31; group A), segmental hepatic artery (18/31; group B), and peripheral inferior phrenic artery (3/31; group C), respectively. In group A, only the third order branches of the portal venous system were visualized anterogradely in 8 of 10 patients. In group B, the microcatheter was placed coaxially through a 5 French guiding catheter at the main arterial supply of the tumor in 7 patients and at the peripheral segmental branch of the hepatic artery in 11 patients. The portal venous system was visualized retrogradely in all of the patients regardless of the injection site. The injected CO2 may flow back into the portal vein through the anastomosis known as the peribiliary or periportal plexus. In group C, not only the portal vein but also the pulmonary artery or pericardial vein were visualized by this method. CO2-IADSA was useful to image the minute communications between the various vessels, which have been not hitherto visualized by iodinated contrast medium.

Adult↗

[Densitometry determination of coronary flow rates using digital subtraction angiography (DSA). Methods, multiple examinations and interobserver comparison].

In invasive diagnostics of coronary heart disease (CHD), three each DSA examinations of the left coronary artery were performed at 2-minute intervals in ten patients subsequent to conventional examination by means of a left-side cardiac catheter and coronary angiography. While placing the patient in left anterior oblique (60 degrees) position, 6 ml each of ionic contrast medium were injected mechanically with a flow of 4 ml/sec at a pacemaker-induced heart rate of 100/min. Examinations were performed according to a standard mode and were evaluated via the image analysing computer APU of the Philips DVI-DSA system. The purpose of this approach was to analyse the examination conditions and a new improved evaluation algorithm in respect of stability, feasibility and sensitivity. 17 series were evaluated by two examiners who were independent of each other. The interobserver differences obtained were between 5% at the time of maximum density (Tmax) and 25% with exponential downward slope of the curve (lambda), with reference to the median value in each case. Scatter of the individual examinations around the median value of all the three DSA runs is 11 to 17% with the exception of lambda. A significant rise can be proven in the RCX region for the curve slope rise parameters "slope" and "RFL2". We interpret this as a genuine 1.2 to 1.3 fold regional flow increase due to the residual effect of the contrast medium. At the same time, this can be interpreted as an indicator for the good sensitivity of the method.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Vertebrocarotid collateral in extracranial carotid artery occlusions: digital subtraction angiography findings.

The internal and external carotid arteries are usually considered occluded distal to a common carotid artery occlusion but some collateral vessels may provide blood keeping the internal and external carotid arteries patent distal to the occlusion. Most common communication in such a case is diversion of blood from muscular branches of the vertebral artery to occipital branch of the external carotid artery which in turn could maintain blood flow into the internal carotid artery, a condition called carotid steal. We encountered vertebrocarotid anastomoses maintaining the patency of carotid circulation in six patients. Patients were four females and two males, ages ranging from 40 to 67 (mean age: 56) years. Five of the patients had ischemic cerebral symptoms. The origin of the external carotid artery was occluded in two and the whole common carotid artery in the remaining four patients. Two patients had double steal, carotid and subclavian at the same time. There was also severe stenosis or occlusion of at least one other major extracranial cerebral artery in all the cases. This concomitant involvement of the second extracranial cerebral artery was thought to be the main reason for the development of vertebrocarotid collateral. In contrast to most of the previously published reports claiming the inadequacy of angiography when compared with colour Doppler ultrasonography, angiography finely depicted the distal patency of the carotid circulation and all the collaterals in detail in every case. Selective injection of the vertebral artery ipsilateral to the occlusion, is the key to demonstrate distal patency of the carotid circulation in cases of proximal carotid occlusion. Demonstration of patency of the distal circulation is very important because some of the patients might get benefit from a reconstructive surgery.

Adult↗

Gadolinium-based contrast media compared with iodinated media for digital subtraction angiography in azotaemic patients.

BACKGROUND: To determine whether gadolinium-based contrast media (CM) could be used safely for angiographies in patients with renal dysfunction we investigated renal function after gadobutrol exposure and compared the results with standard iodinated CM (iohexol) in a randomized clinical study. METHODS: Twenty-one patients (aged 67+/-11 years, nine female and 12 male) with severely impaired renal function [mean serum creatinine 3.2+/-1.3 mg/dl, mean glomerular filtration rate (GFR) 31+/-16 ml/min/1.73 m(2)] who needed to have angiography because of severe peripheral vascular disease, renal artery stenosis or aortic aneurysms were randomized to receive in a blinded manner either gadobutrol (Gadovist 1.0 mmol/ml) or iohexol (Omnipaque 350) as contrast agents. GFR was measured by CM clearance (Renalyzer) at baseline and 48 h after CM administration. The primary end point was the mean change of GFR from baseline at 48 h, the secondary one the incidence of CM-induced acute renal failure, defined as a decrease in GFR of >50% from baseline within 48 h of CM administration. RESULTS: In the gadobutrol group (n = 10) we observed a statistically significant decrease in GFR of 10.6+/-13.8 ml/min/1.73 m(2) within 48 h after CM administration (P<0.05, paired t test). The incidence of CM-induced ARF amounted to 50%. In comparison, the iohexol group (n = 11) also showed a statistically significant GFR reduction of 8.7+/-8.8 ml/min/1.73 m(2) (P<0.05, paired t test), and of ARF by 45%. The percentile of differences of GFR decreases between the two groups was not significant (P = 0.70). No patient demonstrated other adverse effects of gadobutrol or iohexol administration, apart from GFR reduction. Despite the decline in GFR, no patient required haemodialysis in the 10 following days. CONCLUSIONS: In our study, gadolinium-based angiography showed no benefit over iohexol angiography with respect to preventing GFR reduction in patients with severely impaired renal function.

Aged↗