PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Device Removal”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Surgical treatment of morbid obesity by adjustable gastric band: the case for a conservative strategy in the case of failure - a 9-year series.

BACKGROUND: Lapaparoscopic adjustable gastric banding (LAGB) has become a widespread method to treat morbid obesity. Long-term complications and failures require a strategy for reoperation. METHODS: 1,180 patients have been operated on from April 1995 to December 2003. 151 had reoperation for complications (12.7%) excluding access-port problems: slippage (105), erosion (22), intolerance (24). 67 patients (5.6%) had their band removed; only 5 had a switch to another procedure. Esophageal dilatation and insufficient excess weight loss (<25%) after 5 years (13.7%) should also be addressed. Two situations are described: 1) Band in place: anterior slip, dilatation, isolated insufficient weight loss. 2) Band to be removed: posterior slip, severe anterior slip (acute, with necrosis or perforation), erosion, intolerance. Four options are recognized: 1) Conservation (adjustment management) or surgical correction (anterior slip). 2) Placement of a new band: for failure of the device, accidental removal (slippage in difficult conditions), and erosion after a delay. 3) RYGBP or BPD in selected cases only. 4) Other procedures. CONCLUSION: 1) A new band can be placed if there has been a technical problem. 2) Weight control is possible, including in the case of esophageal dilatation. Reoperation for insufficient weight loss without a technical problem is not an option. Failures of VBG cannot be fairly compared with Lap-Band (R) failures because of adjustability. 3) Reoperation is not often demanded. For failure after LAGB, the future should involve less invasive bariatric procedures and nonsurgical approaches.

Adolescent↗

[Ministry of Justice issues circular on sanctions against people who sabotage birth control plans by removing women's intrauterine contraceptive devices].

The relevant document recently issued by the Ministry of Justice pointed out that to protect women's lives and health and to facilitate birth control, severe punishments should be meted out in accordance with the relevant provisions of the criminal law to those who are guilty of the wicked practice of removing women's intrauterine contraceptive devices to defraud money and belongings, bringing about serious consequences as a result. Recently, the Ministry of Justice received a letter from the birth control office in Fuling Prefecture, Sichuan Province, reporting repeated instances in the prefecture of some people sabotaging the birth control plan by illegally removing women's intrauterine contraceptive devices to defraud the women of their money and belongings, and some women had even died as a result. The letter appealed to the judicial organs to ban these activities. In its document in answer to the letter, the Ministry of Justice pointed out, that out of greed for pecuniary and material gains, some people illicitly made iron wire hooks to remove women's intrauterine contraceptive devices, and serious consequences and even deaths have occurred. These activites have not only seriously sabotaged the birth control plan, but also constituted criminal offenses of fraud, unpremeditated injury, and manslaughter in violation of the criminal law. It called on the judicial departments throughout the country to punish the offenders according to the laws. The document also pointed out that some comrades called the illegal activities of illicitly removing women's intrauterine contraceptive devices "inappropriate removal of intrauterine rings," or said that "there are no concrete provisions about it in the laws," the result being that criminals have been allowed to go scot-free. To protect women's lives and health and to facilitate birth control, the judicial organs at all levels should coordinate with the departments concerned to ban such illegal activities and to carry out large-scale education among the masses. Severe judicial punishments should be meted out in accordance with the relevant provisions of the criminal law to those guilty of the illegal and wicked practice of removing women's intrauterine contraceptive devices to defraud money and belongings, bringing about serious consequences as a result.

Asia↗

A rare case of ileal embedding by an intrauterine device.

Ileal penetration by a copper-bearing intrauterine device (IUD) is a rare but serious potential complication. This paper reports the case of a 30-year-old gravida 4 para 3 woman with ileal embedding by an IUD. Laparoscopy was performed on the patient 4 months after the insertion of the IUD. When the tail of the IUD was seen during laparoscopy protruding outside the small bowel, the device was removed through a 1-cm incision in the ileum by laparotomy. This report demonstrates a rare case of ileal embedding of an IUD.

Abdominal Pain↗

Apical suction leads to severe ischemia of the ventricular apex.

OBJECTIVE: Apical suction devices allow displacement of the heart in off-pump coronary artery surgery. However, high vacuum pressure may injure the suctioned myocardium. It has been demonstrated that partial pressure of oxygen in the myocardium (ptiO(2)) is a sensitive and rapid indicator of myocardial ischemia. The purpose of this study is to evaluate the effect of apical suction on the ptiO(2) as an indirect measure of myocardial perfusion of the ventricular apex. METHODS: Twenty-six patients undergoing elective off-pump coronary surgery were studied. Intramyocardial ptiO(2) was continuously measured using a flexible catheter microprobe (Licox GMS mbH, Kiel, Germany). Patients were divided into two groups. In one group (Group A; n=14), the microprobe was intraoperatively inserted into the myocardium of the left ventricular apex. In the second group (Group B; n=12), the probe was inserted in the anterior wall of the left ventricle. Intramyocardial ptiO(2) monitoring was made with the heart in the resting position and after placing the apical suction device. RESULTS: In Group A, basal ptiO(2) was 15.3+/-7.4 mmHg. One minute after placing the apical suction device, the ptiO(2) significantly decreased to 2.3+/-1 mmHg (p<0.001). A progressive increase of ptiO(2) was observed immediately after the Xpose suction device was removed. ptiO(2) was 13.6+/-9.1 mmHg 5 min after releasing the suction cup and increased to 27.2+/-12.6 mmHg 20 min later. In Group B, basal ptiO(2) was 17+/-10.3 mmHg. No significant changes were observed in Group B after placing and removing the suction cup. CONCLUSIONS: Apical suction devices lead to severe ischemia of the suctioned myocardium. Collapse of coronary vessels due to vacuum pressure is a possible mechanism. Reperfusion occurs immediately after removing the suction cup and a significant reactive hyperemia is observed.

Aged↗

Estrus synchronization of lactating dairy cows with GnRH, progesterone, and prostaglandin F2 alpha.

The reproductive performance of synchronized cows was compared with that of nonsynchronized cows. In trial 1, cyclic cows in five seasonal herds were randomly divided into two groups. Cows in one group (n = 515) were treated with a GnRH agonist and an intravaginal progesterone device, followed in 7 d by a PGF2 alpha injection, and the device was removed 1 d after PGF2 alpha. Cows in the other group (n = 512) did not receive any treatment and acted as control. In trial 2, the treatments were similar to those used in trial 1 except that the progesterone device was removed at the time of PGF2 alpha injection (synchronized: n = 516; control: n = 512). The estrus synchronization rate was 92.8% in trial 1 and 92.2% in trial 2. Conception rate to first artificial insemination (AI) was lower for synchronized cows than for control cows in trial 1 (56.5 vs. 62.7%), but similar in trial 2 (64.6 vs. 63.3%). Across both trials, the pregnancy rate during the AI breeding period was greater for the synchronized cows (85.6%) than for the control cows (81.2%). The synchronization treatment reduced the interval from start of the breeding season to conception for cows conceiving by AI (8.9 vs. 14.8 d) or by AI or natural mating (14.1 vs. 21.6 d). The synchronization protocol used in trial 2 achieved better conception rate than that used in trial 1, but the precision of estrus was less in trial 2 than in trial 1.

Administration, Intravaginal↗

Disassembly of a rotablator: getting out of a trap.

The rotablator burr rarely becomes trapped within calcified lesions. Manual traction can be ineffective and dangerous. We report a case that illustrates a novel technique involving use of a percutaneous snare in conjunction with partial disassembly of the rotablator device to remove a trapped burr without need for open surgical intervention.

Aged↗

Midface distraction advancement in the canine without osteotomies.

Midface hypoplasia, often associated with exorbitism and malocclusion, has been traditionally corrected by using Le Fort advancement osteotomies through wide surgical exposure. These procedures suffer the disadvantages of hemorrhage, unpredictable bone graft resorption, the need for retained hardware, and bone graft donor-site morbidity. We present an investigation of midface distraction in the canine without osteotomies. Five canines were the subjects of this study and were divided into two groups. At the time of placement of the lengthening devices, Group 1 animals were 10 weeks of age and Group 2 animals were 5 years of age. Under general anesthesia, four modified Hoffman bone distractors were mounted on 2-mm half pins placed individually across the nasofrontal and the zygomaticotemporal sutures on each side of the craniofacial skeleton. Distraction of all devices was begun on postoperative day 1 at the rate of 0.5 mm/day for 4 days and then 1.0 mm/day for 28 days, after which interval the devices were removed. The dogs were serially monitored and examined for 3 months. One dog in the first group served as a sham control. The results were assessed by standardized cephalograms, and craniofacial computed tomographic scans with three-dimensional reconstruction performed before device placement as well as after removal of the device. In one Group 1 animal, computed tomographic scanning was performed every 2 to 4 weeks for 3 months. Gross examination of the Group 1 animals demonstrated the development of enophthalmos, dolichocephaly, and a class II malocclusion-overbite.(ABSTRACT TRUNCATED AT 250 WORDS)

Age Factors↗

Prosthetic joint infections in the elderly.

PURPOSE: The aim of this study was to review risk factors, presenting symptoms and signs, organisms causing infection, treatment modalities, and outcomes in elderly patients with infection of prosthetic joints. PATIENTS AND METHODS: Patients over 60 years of age treated at the University of Michigan Hospital or Ann Arbor Veterans Administration Medical Center from 1977 to 1987 who had a diagnosis of prosthetic joint infection were reviewed. Early infections were defined as those occurring within 12 months of insertion of the prosthesis; late infections were those occurring more than 12 months after insertion. RESULTS: Fifty-one episodes of infection in 38 elderly patients were reviewed. There were 20 infections in prosthetic hips and 31 infections in prosthetic knees. Twenty-seven infections occurred early and 24 occurred late. Coagulase-negative staphylococci, Staphylococcus aureus, and Group D enterococci were the organisms most commonly isolated (33%, 27%, and 24% of episodes, respectively). Pseudomonas aeruginosa and other gram-negative bacilli were the causative organisms in approximately a third of the infections, and anaerobic organisms were noted in almost one fourth of episodes. In 33 episodes, the infected device was eventually completely removed, but infection resolved in only 20 of these 33 episodes (61%). In 18 episodes treated without removal of the device, none resolved. Outcome was poor; only five patients could walk without assistance, six patients developed contiguous osteomyelitis, two required amputation, and three died. CONCLUSIONS: Infection of prosthetic joints in elderly patients is a serious disease with poor functional outcome. The device has to be removed in order to clear the infection, and even then the infection is often difficult to eradicate.

Aged↗

Partial aortic valve fusion induced by left ventricular assist device.

BACKGROUND: Left ventricular assist devices (LVADs) may be used (1) as a bridging device to cardiac transplantation, (2) for permanent replacement of left ventricular function, and (3) as a bridge to recovery of ventricular function, for example, in recoverable myocardial disease. In this third group of patients, it is important that the LVAD does not produce changes in the heart that will have a deleterious effect on cardiac function once the device is removed. Furthermore, if the LVAD fails, survival depends on optimal function of the diseased heart. METHODS: All hearts with LVADs encountered as surgical specimens following heart transplantation or at autopsy at the Fairview-University of Minnesota Medical Center during the 5-month period August 1998 to January 1999 were examined for native valvular heart disease. The nature and extent of commissural fusion was noted and measured. Light microscopy was performed on any valve lesions. RESULTS: Four of 6 patients with HeartMate (Thermo Cardiosystems, Inc, Woburn, MA) LVADs showed evidence of commissural fusion (acquired aortic stenosis). In 1 patient, this condition was caused by an organizing thrombus uniting a 14-mm length of the commissural region of the right coronary and noncoronary cusps of the aortic valve. Fibrous commissural fusion due to totally organized thrombus in the other 3 patients affected one aortic commissure (2 patients, 2 mm and 4 mm, respectively) and two commissures (1 patient, 2 mm and 5 mm). Partial cuspal fusion in each case was due to permanent closure of the native aortic valve induced by the LVAD's operating in its automatic setting. Mean length of commissural fusion was 5.4 mm (range, 2 to 14 mm; standard deviation [SDI = +/-5.0 mm). Mean duration of implantation of the six LVADs was 180.3 days (range, 26 to 689 days; SD = +/-253.8 days). The LVADs of the 3 patients with fibrous fusion of the commissures had been implanted for an average of 252.3 days (range, 26 to 689 days; SD = +/-378.2 days). CONCLUSIONS: Normal function of the LVAD produces permanent closure of the native aortic valve. Stasis on the ventricular aspect of the aortic valve, combined with a low level of anticoagulation, favors thrombosis at this site. Thrombus organization leads to aortic stenosis of variable severity. This previously unsuspected complication was not detected clinically in any of our patients. Aortic stenosis may hold serious implications for patients in whom the LVAD acts as a bridge to recovery or in those in whom the LVAD fails. Prevention may be achieved by intermittently reducing LVAD pumping action. A built-in venting cycle would be of value in long-term implants. Thrombi on the aortic valve may also predispose patients to infective endocarditis, because bloodstream infection is common in patients with LVADs.

Aged↗

[External fixation in fractures of the lower limb in children].

PURPOSE OF THE STUDY: The indications, morbidity and results of the use of external fixation for fractures of the lower limbs in children is presented. MATERIAL AND METHOD: We studied 72 fractures of the lower limbs (femur: 25; tibia: 47) in 63 children over a seventeen year period. Average age at fracture was 10 yrs 6 mos. (range 4 yrs 5 mos to 14 yrs 6 mos). Forty fractures were open fractures. The indication for external fixation was decided in three different situations: 39 isolated fractures, 11 patients with multiple fractures, and 13 polytraumatized patients. Three different devices were used: Illizarov: 4, Judet: 16, Orthofix: 52. The fixators were left in place until fracture union was demonstrable. RESULTS: Final results were classed into three groups: good, good following reoperation and sequelae. Comparison of the three different series was made using Student's T test. 9 axial deviations or malrotations occurred: 6 times correction was possible with the device in place. Three cases of osteomyelitis occurred at the fracture site. 23 pin tract infections occurred (23 per cent) 5 of which were persistent and 4 required reoperation. The average healing time was different in the three groups: 4.5 mos for isolated fractures: 8.1 mos for multiple fractures and 5.7 mos for polytraumatized patients. Reoperation was required for 4 patients: 2 bone grafts, 1 decortication, 1 bone transport. Ten refractures occurred following removal of the device, 8 times in patients presenting multiple injuries. In 46 patients with a follow-up greater than 18 months, 9 presented an overgrowth between 1 and 2 cm. Following an average follow-up of 2 years 4 months, 7 patients presented sequelae, 56 had good results, 18 following reoperation. DISCUSSION: The use of external fixation remains an irreplaceable method for osteosynthesis of open fractures with severe soft tissue injuries, multiple fractures or in the polytraumatized patient. Some disadvantages such as pin tract infections and refracture following device removal should be taken into consideration before using it for the treatment of simple, isolated closed fractures of the lower limbs in children. CONCLUSION: When external fixation is chosen for treating fractures, it is preferable to use a modular device which allows axial corrections. Local pin site care is essential to prevent early infection. Early weight bearing and dynamization as soon as possible will promote callus mineralization, removal of the device must be progressive and cast protection is recommended.

Adolescent↗

Ripening and dilatation of the unfavourable cervix for induction of labour by a double balloon device: experience with 250 cases.

OBJECTIVE: To determine the efficacy of the double balloon device (the Atad Ripener Device) in ripening and dilatation of the unfavourable cervix for induction of labour. METHODS: Two hundred and fifty women with unfavourable cervices (Bishop score < or = 4) underwent induction of labour with the Atad Ripener Device. Indications were pregnancy induced hypertension (n = 118), post-dates (n = 69), elective inductions (n = 23), other reasons including nonreassuring nonstress test, intrauterine growth retardation, previous caesarean section and diabetes mellitus (n = 40). The Atad Ripener Device was inserted into the cervix, the uterine balloon inflated in the internal os, and the cervico-vaginal balloon in the external os of the cervix (100 mL of normal saline to each balloon). Pressure produced by the inflated balloons caused gradual dilatation and effacement of the cervix. The Atad Ripener Device was removed 12 h after insertion, the cervix assessed again, and labour managed according to obstetrical criteria. RESULTS: The Atad Ripener Device caused an increase in the Bishop score in all subgroups with a mean change of 4.6 (from 2.0 prior to induction to 6.6 upon removal of the Atad Ripener Device; P < 0.05). The mean time interval from insertion of the Atad Ripener Device to delivery was 18.9 h, and from removal to delivery was 6.9 h. Caesarean section was performed in 39/250 patients (16%), and the others had a normal vaginal delivery. CONCLUSIONS: 1. The double balloon device induces significant ripening and dilatation of the unfavourable cervix. 2. Induction of labour was successfully achieved following removal of the Atad Ripener Device. 3. Our caesarean section rate was low compared with rates reported for women with an unfavourable cervix induced by other methods.

Adult↗

Difficulty in removal of the distal locking device of the Brooker-Wills tibial nail.

Complications in removal of the Brooker-Wills tibial nail were encountered in eight patients, and breakage of the distal fins occurred in four of these patients. Although none of the patients experienced residual effects related to removal of the tibial nail, the procedure is associated with potential risks such as infection or nonunion. Three methods of nail removal are described.

Adult↗

Gastro-clip gastroplasty: a very long-term complication.

For most surgeons, the gastro-clip gastroplasty is an unfamiliar operation. It was performed during the mid 1980s as an alternative to more complex bariatric operations. However, the device had problems. Because of its rigid nature, it occasionally eroded into the stomach and chest. Many of these devices required removal. However, patients may occasionally present with delayed complications. We present a patient with a Gastro-clip gastroplasty, who presented years after the procedure with a functional gastric outlet obstruction.

Deglutition Disorders↗