Study of real time temperature profiles in routine TLD read out--influences of detector thickness and heating rate on glow curve shape.

This paper reports the results of a study using a commercial routine read out system with non-contact hot nitrogen heating and linear heating gas profiles. Glow curves of LiF:Mg,Ti as well as LiF:Mg,Cu,P were analysed for different linear heating rates beta from 1 to 30 degrees K s(-1). Different thermoluminescent detectors (TLDs) of different thicknesses (0.38-0.90 mm) were studied and compared. By means of the application of CGCD program considering kinetic parameters of the used TL-material the analysis of the peak temperature of the individual TL peaks lead to the approximation of the real heating profile T(chip)(t) in the TL chip. The real heating profile deviates strongly from linearity and can be characterised by the solution of a differential equation T(chip)(t) = F [T(gas)(t)]. The model of this equation is discussed in the paper. The difference between gas and chip temperatures are heating rate and chip thickness dependent and reach values of up to 100 degrees C (for thick detectors and fast heating rates). Especially for LiF:Cu,P, knowledge of the real chip temperature is essential, since read out shall be performed at the highest possible temperature, without destroying the dosimetric properties of the material. On the basis of this work, an optimisation of the readout parameters for LiF:Cu,P is possible.

Computer Simulation↗

Performance of Harshaw TLD-100H two-element Dosemeter.

One of the advantages of LiF based thermoluminescent (TL) materials is its tissue-equivalent property. The Harshaw TLD-100H (LiF:Mg,Cu,P) material has demonstrated that it has a near-flat photon energy response and high sensitivity. With the optimized dosemeter filters built into the holder, the Harshaw TLD-100H two-element dosemeter can be used as a whole body personnel dosemeter for gamma, X ray and beta monitoring without the use of an algorithm or correction factor. This paper presents the dose performance of the Harshaw TLD-100H two-element dosemeter against the ANSI N13.11-2001 standard and the results of tests that are required in IEC 1066 International Standard.

Dose-Response Relationship, Radiation↗

Low temperature radioluminescence of LiF:Mg,Cu,P.

Low temperature radioluminescence spectra of LiF, variously co-doped with Mg, Cu and P, show highly unusual temperature dependencies which resemble thermoluminescence data. The signals include intense peaks and a relatively weak continuous background. One peak occurs below 30 K, together with a major peak near 125 K. The signals are highly sensitive to the dopants and slightly sensitive to X-ray dose rate. The role of donor acceptor pairs and the perturbations from intrinsic defects formed by ionisation can be used to describe all the observations. The 290 nm emission band is linked to H center annealing.

Copper↗

Neutron dosimetry with 6LiF-rich TL sheet.

A (6)LiF-rich thermoluminescent sheet-type dosemeter ((6)LiF-rich NTL sheet) was developed for neutron 2D dosimetry. The dosemeter utilises the (6)Li(n, alpha)(3)H reaction to detect thermal neutrons. Responses of the (6)LiF-rich NTL sheet to neutrons were measured at the neutron beam irradiation facility for BNCT in JRR-4 Research Reactor at the Japan Atomic Energy Research Institute. Placement of a multi-leaf collimator at the output port of the neutron (beam) irradiation facility, produced either stripe- or round-shaped neutron distributions; the spatial distribution was measured using the developed NTL sheets. Direct measurements of neutron attenuation in water were also carried out using the developed NTL sheet, submersed in a water phantom. In each experiment, NTL sheets having natural abundance (7.9%) of LiF, and (6)LiF-enriched NTL (18.94%) sheet were irradiated under the same conditions. The ratio of thermoluminescence intensities of the (6)LiF-rich NTL sheet to that of the normal NTL sheet was compared to a theoretically calculated value. The experimental measurements are shown to be in good agreement with the calculations.

Boron Neutron Capture Therapy↗

On neutron-gamma mixed field dosimetry with LiF:Mg,Ti at radiation protection dose levels.

The possibility of using the specific responses of the high temperature Peaks 6 and 7 and Peaks 4 and 5 to different LET radiations was mentioned in the past mainly for very high doses. The applicability of the two regions method for thermal neutrons--gamma ray mixed field dosimetry was investigated by analysing the response of LiF:Mg,Ti dosemeters irradiated to different ratios of thermal neutrons and gamma rays at radiation protection dose levels encountered in routine work conditions, up to approximately 50 mSv. The Region of Interest method was used to define the areas of the Peaks 4 + 5 and 6 + 7. We found that a simple algorithm can be used to determine with good accuracy the separate contributions of neutron and gamma doses.

Computer Simulation↗

Response of LiF:Mg,Ti to low energy carbon and oxygen ions.

The extended track interaction model (ETIM) has been formulated to explain the TL-fluence response for peak 5 to heavy ions using radial dose distributions produced by the ions in LiF and their luminescent centre occupation probability distributions. In this work, an experimental study of the TLD-100 fluence response to carbon and oxygen ions and its interpretation in terms of a Monte Carlo simulation of ETIM applied to peak 5 are presented. Irradiations were performed with 7.34 and 10.3 MeV 12C and 8.34 MeV 16O ions in the fluence interval between 2 x 10(7) and 2 x 10(11) cm(-2). Individual glow curve responses show the expected increase of supralinearity as the peak temperature increases. Data for peak 5 show a weak dependence with energy. These latter results are difficult to understand when one considers the differences in the expected radial occupancies for different ion energies.

Carbon Radioisotopes↗

Dosimetry of densely ionising radiation with three LiF phosphors for space applications.

A new method of thermoluminescence dosimetry of densely ionising radiation based on the ratio of different efficiency-LET functions of three thermoluminescent detectors (TLDs) has been developed. The applied TLD types are: MTS-7 ((7)LiF:Mg,Ti), MCP-7 ((7)LiF:Mg,Cu,P) and MTT-7 (a newly developed (7)LiF:Mg,Ti with modified activator composition and increased response to high-LET radiation). The tests of this method, performed with high-energy ion beams at the HIMAC accelerator within the ICCHIBAN project, proved that good agreement with the true dose values may be achieved even in very complicated mixed fields. The proposed method will be applied for analysis of several thousand TLDs used for the determination of organ doses in an anthropomorphic phantom orbiting outside the International Space Station within the MATROSHKA experiment.

Dose-Response Relationship, Radiation↗

Comparison of the energy-response factor of LiF and Al2O3 in radiotherapy beams.

A Monte Carlo study of the energy-response factor of aluminium oxide (Al2O3) and lithium fluoride (LiF) TLDs in kilovoltage and megavoltage photon beams relative to 60Co gamma rays has been performed using EGSnrc Monte Carlo simulations. The sensitive volume of the detector was simulated as a disc of diameter 2.85 mm and thickness 1 mm. The phantom material was water and the irradiation depth was 2.0 cm in kilovoltage photon beams and 5.0 cm for megavoltage photon beams. The results show that the energy-response of the Al2O3 and LiF-TLDs is constant within 3% for photon beam energies in the energy range of 60Co gamma rays to 25 MV X rays. However, both detectors show an enhanced response for kilovoltage photon beams, which in the case of 50 kV X rays is 3.2 times higher than that for 60Co gamma rays. The energy-response factor was 1.46 for LiF irradiated in 50 kV X rays. The Al2O3 detector has an energy-response that is 2.2 times higher than that of LiF in 50 kV X rays decreasing to 1.19 for 250 kV X rays. The results show that the addition of 0.1 or 1% of carbon by weight (as dopant) into the Al2O3 does not change the Monte Carlo determined energy-response factor by more than 1%.

Algorithms↗

The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions.

LiF:Mg,Cu,P is starting to replace LiF:Mg,Ti in a variety of personnel dosimetry applications. LiF:Mg,Cu,P has superior characteristics as compared to LiF:Mg,Ti including, higher sensitivity, improved energy response for photons, lack of supralinearity and insignificant fading. The use of LiF:Mg,Cu,P in large scale dosimetry programs is of particular interest due to the extreme sensitivity of this material to the maximum readout temperature, and the variety of different dosimetry aspects and details that must be considered for a successful implementation in routine dosimetry. Here we discuss and explain the various aspects of large scale LiF:Mg,Cu,P based dosimetry programs including the properties of the TL material, new generation of TLD readers, calibration methodologies, a new generation of dose calculation algorithms based on the use of artificial neural networks and the overall uncertainty of the dose measurement. The United States Navy (USN) will be the first US dosimetry processor who will use this new material for routine applications. Until June 2002, the Navy used two types of thermoluminescent materials for personnel dosimetry, CaF2:Mn and LiF:Mg,Ti. A program to upgrade the system and to implement LiF:Mg,Cu,P, started in the mid 1990s and was recently concluded. In 2002, the new system replaced the LiF:Mg,Ti and is scheduled to start replacing the CaF2:Mn system in 2006. A pilot study to determine the dosimetric performance of the new LiF:Mg,Cu,P based dosimetry system was recently completed, and the results show the new system to be as good or better than the current system in all areas tested. As a result, LiF:Mg,Cu,P is scheduled to become the primary personnel dosimeter for the entire US Navy in 2006.

Copper↗

Determination of LiF:Mg,Ti and LiF:Mg,Cu,P TL efficiency for X-rays and their application to Monte Carlo simulations of dosemeter response.

The simulation of response of a new passive area dosemeter for measuring ambient dose equivalent H*(10) for photons has been performed using the Monte Carlo code MCNP and experimentally determined responses of LiF:Mg,Ti and LiF:Mg,Cu,P thermoluminescent (TL) detectors for hard-filtered X-ray spectra from 20 to 300 keV and for 137Cs and 60Co gamma radiation. Relative TL efficiency for both types of detectors, determined in experiments with bare detectors and similar Monte Carlo simulations, compared favourably with prediction of microdosimetric models for proposed microdosimetric target sizes in the range of 20-40 nm. The concluding verification experiment showed small deviations between measured and simulated dosemeter energy response values in the range of a few percent.

Algorithms↗

Sensitivity loss of Lif:Mg,Cu,P thermoluminescence dosemeters caused by oven annealing.

LiF:Mg,Cu,P is a very sensitive thermoluminescence material that can be used for personal dosimetry in radiology. But if this material is heated too much during annealing or reading it quickly loses its sensitivity. This study shows that an annealing oven in wide use can cause thermal damage to the dosemeters owing to inhomogeneous temperature distribution in the annealing tray. At annealing temperatures>240 degrees C, differences of only 1 degrees C lead to significant losses of sensitivity. Therefore, it is necessary to measure the distribution of temperature in the annealing tray for correct placement of the dosemeters in the tray.

Copper↗

Comparison of the effects of exposure to light in Harshaw LiF:Mg,Ti and LiF:Mg,Cu,P.

The response of thermoluminescence dosemeters (TLDs) to light, in various conditions, has been studied. TLD cards containing both conventional lithium fluoride (LiF:Mg,Ti) and the high-sensitivity material LiF:Mg,Cu,P were available, so permitting a comparison between the two types. Also available for the tests were Harshaw extremity EXT-RAD (LiF:Mg,Cu,P) dosemeters. The LiF:Mg,Ti body TLD cards and the EXT-RAD extremity dosemeters both showed some response to fluorescent light, while the LiF:Mg,Cu,P cards showed no significant response. It is therefore concluded that LiF:Mg,Cu,P body cards need no special precautions to protect them from the effects of light. For LiF:Mg,Ti cards and extremity dosemeters, effects are small, but steps to avoid excessive light exposure should be considered.

Artifacts↗

Development of LiF:Mg,Cu,Si TL material (new KLT-300) with a low-residual signal and high-thermal stability.

LiF-based thermoluminescence (TL) materials have been widely used for radiation dosimetry due to their attractive features. LiF:Mg,Cu,P is one of the most sensitive tissue-equivalent TL materials, approximately 40 times more sensitive than LiF:Mg,Ti (TLD-100), but it has two main drawbacks: a thermal loss of the TL sensitivity when annealed at temperatures>240 degrees C, and a relatively high-residual signal. Recently, LiF:Mg,Cu,Na,Si TL material was developed to overcome these drawbacks at the Korea Atomic Energy Research Institute, but it provided only marginal improvements in reducing the residual signal. The newly developed LiF:Mg,Cu,Si TL material has a significantly lower residual signal and a better stability to thermal treatments. In this article, the preparation method and some dosimetric properties (sensitivity and residual signal) of the new LiF:Mg,Cu,Si TL material are presented. At the end of the preparation procedures, a dual-step annealing method is introduced and this has proved as a very efficient method to reduce the high-temperature peak and is the cause of residual signal. Therefore, the high-temperature peak in the glow curve was significantly reduced. The sensitivity is approximately 20 times higher than that of TLD-100 and the residual signal was estimated to be approximately 0.04%.

Dose-Response Relationship, Radiation↗

Dosimetric properties of new cards with high-sensitivity MCP-N (LiF:Mg,Cu,P) detectors for Harshaw automatic reader.

A new configuration for a thermoluminescent dosimetric card has been developed through collaboration between the Institute of Nuclear Physics in Kraków and several commercial dosimetric companies. The card is based on high-sensitivity LiF:Mg,Cu,P circular pellets (MCP-N) welded inside synthetic foils. The basic configuration consists of two pellets of 3.6 mm diameter and thicknesses from 0.25 up to 0.38 mm. The cards can be processed in a standard 6600 or 8800 Harshaw automatic TLD reader. The dosemeters demonstrate very high sensitivity, low background and good stability. This article presents results of the performance tests of the new dosimetric cards in the automatic TLD readers and a comparison of their properties.

Environmental Exposure↗

A comparative study on the susceptibility of LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (TLD-100H) to spurious signals in thermoluminescence dosimetry.

It is well known that spurious signals can occur in thermoluminescence dosimetry (TLD) whenever contaminants (i.e. dirt, oil, dust) are present on the surface of the TLD card or crystal during the read-out process. For TLD cards, the Teflon material can also contribute to the background noise and this contribution has been found to depend on the material's light absorption. These non-radiation-induced signals contribute to the total light output during TLD read-out and can lead to incorrect dosimetry especially for low-dose measurements such as personal dosimetry. However, these spurious signals are generally in the low-temperature channels and are mostly accompanied by abnormal glow curves. Most of the published reports dealing with this type of spurious TL signal are on the LiF:Mg,Ti (TLD-100) material. The relatively new TLD material, LiF:Mg,Cu,P, is more sensitive and has higher signal-to-noise ratio than the traditional LiF:Mg,Ti. In this study, the effects of disturbing signals to the LiF:Mg,Cu,P (TLD-100H) cards used in personal dosimetry are investigated and compared with those of LiF:Mg,Ti (TLD-100).

Artifacts↗

An aqueous formulation of gamma-linolenic acid with anti-proliferative action on human pancreatic cancer cell lines.

Essential fatty acids, especially gamma-linolenic acid (GLA), have been shown to directly inhibit the growth of cancer cell lines in culture. The aim of this study was to see whether an aqueous formulation of GLA works as well as the lithium-based salt. We evaluated the effect of the 1-deoxy-1-methylamino-D-glucitol salt of GLA (MeGLA) on the growth of two human pancreatic cancer cell lines (Panc-1 and MIA PaCa-2) in vitro, and compared its effects with a previously studied formulation, lithium GLA (LiGLA). The effect of time exposure (2-7 days) and difference in concentration (0-1000 micromol/l) were studied using 96-well culture plates. Cell growth was assessed by MTT assay. Control experiments were performed with meglumine alone in similar concentrations. MeGLA had cytostatic and cytotoxic effects on pancreatic cancer cell lines with 50% growth inhibition at 30-100 micromol/l and cytotoxic effects at 60-250 micromol/l. The degree of growth inhibition increased with time of exposure to MeGLA. The anti-proliferative effects of MeGLA were similar to those previously observed with LiGLA. We conclude that MeGLA has equivalent anti-proliferative activity to LiGLA when tested in vitro against pancreatic cancer cell lines and is therefore a suitable alternative to LiGLA for investigation of the in vivo activity of GLA against pancreatic adenocarcinomas.