PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “POLAROGRAPHY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Study on the polarographic catalytic wave of vitamin P in the presence of persulfate and its application.

The polarographic catalytic wave of vitamin P in the presence of persulfate was studied by linear potential scan polarography and cyclic voltammetry. Vitamin P yielded a single reduction wave in acidic aqueous solution, which was ascribed to a 2e(-), 2H(+) reduction of the carbonyl group in the C-4 position. Actually, the carbonyl group C=O first underwent a 1e(-), 1H(+) reduction to form a neutral free radical, and the further 1e(-), 1H(+) reduction of the free radical was simultaneous with its following chemical reactions. When S(2)O(2-)(8) was present, the free radical of vitamin P was oxidized by both S(2)O(2-)(8) and its reduction intermediate, the sulfate radical anion SO(*-)(4), to regenerate the original, which resulted in the production of a polarographic catalytic wave of vitamin P. Based on this catalytic wave, a novel method for the determination of vitamin P was proposed. In 0.02 M tartaric acid-sodium tartrate (pH 3.3) buffer containing 5.0 x 10(-3) M K(2)S(2)O(8), the peak potential of the catalytic wave was -1.42 V (vs SCE) and the peak current was rectilinear to the vitamin P concentration in the range of 8.0 x 10(-9)-1.0 x 10(-6) M (r = 0.9994, n = 13). The catalytic wave of 2.0 x 10(-7) M vitamin P enhanced the polarographic current 70 times compared with the corresponding reduction wave. The detection limit was 2.0 x 10(-9) M, and the relative standard deviation at the 2.0 x 10(-7) M level was 0.7% (n = 15). The proposed method was used for the determination of vitamin P content in the pharmaceutical preparation of tablets and the medicinal plant Sophora japonica L. without previous separation.

Catalysis↗

Opening of potassium channels protects mitochondrial function from calcium overload.

Ischemic preconditioning (IPC) protects myocardium from ischemia reperfusion injury by activating mitochondrial K(ATP) channels. However, the mechanism underlying the protective effect of K(ATP) channel activation has not been elucidated. It has been suggested that activation of mitochondrial K(ATP) channels may prevent mitochondrial dysfunction associated with Ca(2+) overload during reperfusion. The purpose of this experiment was to study, in an isolated mitochondrial preparation, the effects of mitochondrial K(ATP) channel opening on mitochondrial function and to determine whether it protects mitochondria form Ca(2+) overload. Mitochondria (mito) were isolated from rat hearts by differential centrifugation (n = 5/group). Mito respiratory function was measured by polarography without (CONTROL) or with a potassium channel opener (PINACIDIL, 100 microM). Different Ca(2+) concentrations (0 to 5 x 10(-7) M) were used to simulate the effect of Ca(2+) overload; state 2, mito oxygen consumption with substrate only; state 3, oxygen consumption stimulated by ADP; state 4, oxygen consumption after cessation of ADP phosphorylation; respiratory control index (RCI: ratio of state 3 to state 4); rate of oxidative phosphorylation (ADP/Deltat); and ADP:O ratio were measured. PINACIDIL increased state 2 respiration and decreased RCI compared to CONTROL. Low Ca(2+) concentrations stimulated state 2 and state 4 respiration and decreased RCI and ADP:O ratios. High Ca(2+) concentrations increased state 2 and state 4 respiration and further decreased RCI, state 3, and ADP/Deltat. PINACIDIL improved state 3, ADP/Deltat, and RCI at high Ca(2+) concentrations compared to CONTROL. Pinacidil depolarized inner mitochondrial membrane, as evidenced by decreased RCI and increased state 2 at baseline. Depolarization may decrease Ca(2+) influx into mito, protecting mito from Ca(2+) overload, as evidenced by improved state 3 and RCI at high Ca(2+) concentrations. The myocardial protective effects resulting from activating K(ATP) channels either pharmacologically or by IPC may be the result of protecting mito from Ca(2+) overload.

Animals↗

Nitroarene reduction and generation of free radicals by cell-free extracts of wild-type, and nitroreductase-deficient and -enriched Salmonella typhimurium strains used in the umu gene induction assay.

Studies of the enzymatic properties of cell-free extracts prepared from overnight cultures of the normal, and nitroreductase-deficient and -enriched strains of Salmonella typhimurium, designed for use in the umu gene induction assay of Oda et al. (1992), were undertaken in an effort to clarify the nature of nitroreductase deficiency in relation to mutagenicity. The ability of these strains to promote oxygen consumption and free radical intermediates of representative nitroarene substrates was measured, respectively, by oxygen polarography and electron spin resonance (ESR) spectroscopy. The substrates 4-nitropyridine N-oxide (4NPO) and 4-nitroquinoline N-oxide (4NQO) stimulated the rate and extent of NADH-dependent oxygen consumption catalyzed by cell-free extracts prepared from wild-type, and nitroreductase-deficient and -enriched strains. The extent of oxygen consumption was greater than stoichiometric with respect to the amount of nitroaromatic substrate, which implied one-electron reduction of 4NQO by these bacterial extracts and subsequent redox cycling with oxygen. ESR spectroscopy confirmed the production of free radical metabolites of the nitroarene substrates, which were inferred by the oxygen consumption studies. At equal protein concentrations the cell-free extracts of each strain catalyzed univalent reduction of 4NPO yielding the 59 line signal characteristic of the 4NPO nitro anion radical. This ESR signal was potently inhibited by the flavoprotein inhibitors CuSO4 and PCMB, albeit a twofold or higher concentration of both inhibitors was required to inhibit the signal produced by extract from the nitroreductase-deficient strain than that produced by the other strains. The results indicate that the nitroreductase-deficient strain of Salmonella typhimurium developed for use in the umu gene induction assay is not deficient in either one-electron nitro group or quinone reductase activity.

4-Nitroquinoline-1-oxide↗

Disruption of mitochondrial respiration by melatonin in MCF-7 cells.

Clinical and laboratory studies have provided evidence of oncostatic activity by the pineal neurohormone melatonin. However, these studies have not elucidated its mechanism of action. The following series of MCF-7 breast tumor cell studies conducted in the absence of exogenous steroid hormones provide evidence for a novel mechanism of oncostatic activity by this endogenous hormone. We observed a 40--60% loss of MCF-7 cells after 20-h treatment with 100 nM melatonin, which confirmed and extended previous reports of its oncostatic potency. Interestingly, there were no observed changes in tritiated thymidine uptake, suggesting a lack of effect on cell cycle/nascent DNA synthesis. Further evidence of a cytocidal effect came from morphologic observations of acute cell death and autophagocytosis accompanied by degenerative changes in mitochondria. Studies of mitochondrial function via standard polarography revealed a significant increase in oxygen consumption in melatonin-treated MCF-7 cells. Enzyme-substrate studies of electron transport chain (complex IV) activity in detergent permeabilized cells demonstrated a concomitant 53% increase (p < 0.01) in cytochrome c oxidase activity. Additional studies of succinate dehydrogenase activity (complex II) as determined by reduction of (3-4,5-dimethylthiazol-2-yl)2,5-diphenyltetrazolium bromide demonstrated a significant increase (p < 0.05) in melatonin-treated cells and further confirmed the accelerated ET activity. Finally, there was a 64% decrease (p < 0.05) in cellular ATP levels in melatonin-treated cells. The G-protein-coupled melatonin receptor antagonist luzindole abrogated the cytotoxic and mitochondrial effects. These studies suggest a receptor-modulated pathway of cytotoxicity in melatonin-treated MCF-7 tumor cells with apparent uncoupling of oxidative phosphorylation.

Adenocarcinoma↗

Does tumour related oedema contribute to the hypoxic fraction of human brain tumours?

Focal hypoxia has been demonstrated and is known to contribute to the resistance of malignant brain tumours to radiation and chemotherapy. Using dynamic needle micro-polarography and tissue morphometry on biopsy specimens, the relationship between the effect of oedema on tissue structure and tissue pO2 was investigated in 24 patients undergoing craniotomy for tumour decompression. An inverse correlation (r = -0.84) was found for intercapillary distance and pO2 levels in peritumoural white matter, but this was less marked (r = -0.22) in tumour, probably as a result of sampling difficulties from tissue heterogeneity. Comparison of maximum pO2 levels in oedematous peritumoural white matter with those in tumour suggests that peritumoural oedema is unlikely to contribute to tumour hypoxia.

Adolescent↗

[Demonstration and identification of a new Maillard compound in heated milk].

By means of polarography a new Maillard product (5a) was detected in heated milk. The compound was isolated from a glycine/lactose mixture, which had been heated in buffer at pH 6,8, and then freeze dried by extraction with ethylacetate/methanol. According to its spectroscopic properties, 5a is 4-0-beta-D-galactopyranosyl-2-hydroxy-2-methyl-2H-pyran-3-(6H)-one. Though the amount of 5a formed during heat treatment of milk corresponds to the severity of heat stress, the usefulness of 5a as an indicator with respect to intensity of heat treatment is limited. 5a is rather rapidly converted to galactosyl isomaltol; also unknown peaks develop in the polarogram.

Acetylation↗

Reactivity of nitro-thiophene derivatives with electron and oxygen radicals studied by pulse radiolysis and polarographic techniques.

A new series of nitrothiophene derivatives have been synthetized and some of the physico-chemical parameters which can influence both their radiosensitizing efficiency and toxicity have been investigated. These include octanol/water partition coefficient (P), one-electron reduction potential (E7(1] and reactivity of the drugs towards primary radical species. For these studies, pulse radiolysis techniques and conventional polarography have been extensively used. Biological responses (both sensitization and toxicity) have been tested towards Chinese Hamster cells in vitro. The results are valuable in selecting, among the tested compounds, 5-NTMA, 5-NTM, 4- and 5-NTCA as the nitrohiophenes promising for in vivo applications.

Animals↗

Changes in DNA properties due to treatment with the pesticides malathion and DDVP.

Properties of calf thymus DNA were investigated after treatment with the pesticides malathion (0,0-dimethyl-S-(1,2-bis ethoxycarbonyl ethyl)dithiophosphate) and DDVP (0,0-dimethyl-0-(2,2 dichlorovinyl)phosphate) in vitro by means of derivative (differential) pulse polarography (DPP), thermal denaturation curves recorded spectrophotometrically (Tm), viscometric measurements, and chromatography on the hydroxyapatite column. Changes in the properties of DNA were observed by means of DPP after only a few hours incubation with the pesticides, whereas the other methods did not detect any changes even after 48 h. The results obtained by DPP indicate that single-stranded segments and thermolabile regions are formed in DNA due to the action of the pesticides. This behaviour could perhaps be a consequence of guanine alkylation followed by depurination and chain scission at elevated temperatures. Malathion and DDVP differ in the kinetics of reaction with double-helical DNA. DDVP is more reactive and its action is also manifested after 72 h in changes in viscosity, Tm, and chromatographic behaviour on the hydroxyapatite column. The changes induced by malathion were, under identical conditions, not detectable by these methods.

Animals↗

Chemical evidence for interactions between vitamins E and C.

Experimental proof is provided for interactions between radicals of vitamin E/vitamin C as generated by air-oxidized lipids (liquid fraction of subcutaneous chicken fat). Using ESR spectroscopy, hydrogen atom exchange is shown to take place between vitamin C and the radical of vitamin E. Sequential consumption of these two vitamins in oxidized lipid, first vitamin C then vitamin E, is demonstrated by means of differential pulse polarography. These results elucidate the in vitro radical scavenging functions attributed to vitamin E and vitamin C as well as their synergism in lipid antioxidation.

Adipose Tissue↗

Polarographic activity of the antitumor drug cis-dichlorodiammineplatinum (II). The effect of hydrolysis and trans-isomerization of the drug.

Electrochemical activities of cis-dichlorodiammineplatinum (II) (cis-DDP) and its trans isomer were studied by classical and differential pulse polarography (d.p.p.). It was shown that both isomers yielded a polarographic step or peak at about -1.6 V (vs. Ag/AgCl), which corresponded to electroreduction of the complex and to catalytic hydrogen evolution. This signal was easily measurable with the aid of d.p.p. and was suitable for investigation of the extent of hydrolysis and trans-isomerization of cis-DDP leading to the formation of toxic products. The detection limit for determination of cis-DDP and its trans isomer by d.p.p. was 1 X 10(-6) mol/l.

Chlorides↗

Potential carcinogenicity of some transition metal ions.

Potential carcinogenicity of some transition metal ions was tested using a direct-current polarography method. The measurements were based on the reduction of tested compounds in an anhydrous solution using alpha-lipoic acid as the detection compound. The potential carcinogenicity was expressed in terms of the parameter tg alpha, which is known to directly correlate with the carcinogenicity of tested compounds. For the metal ions tested, tg alpha was found to decrease in the following sequence: Fe(III) > Pb(II) > V(IV) > Fe(II) > Mn(II) > Cu(II). Zero values of tg alpha were found for Cd(II) and Mn(III).

Animals↗

Inline blood gas analysis by gas chromatography in patients during and after coronary artery surgery.

A system was evaluated of measuring Pao2 and Pao2 by an inline sensor in the brachial artery and gas chromatography. Eight patients having coronary artery vein grafts were studied during anaesthesia, operation, perfusion and for 24 hours afterward. Compared to conventional blood gas analysis by polarography (electrodes), the chromatographic method gave readings for Pao2 which were not significantly different during normothermia. During hypothermic perfusion, the chromatographic system read significantly higher than the bench electrode, due at least in part to a difference in temperature correction. For Pao2 the correlation between the two methods was close and differences were clinically insignificant. The Sentorr blood-gas analyser provides a sensitive, accurate indicator of changes in oxygenation, ventilation and circulation during anaesthesia and in the intensive care unit.

Anesthesia, Inhalation↗

Differential pulse polarographic determination of poly(8-hydroxyquinoline) in the presence and absence of an insulating poly(vinyl alcohol) matrix.

The electrochemical activity of poly(8-hydroxyquinoline) (PHQ) in acid and alkaline media has been investigated by use of differential pulse polarography (DPP). The reduction peak height (I(p)) of PHQ in universal buffer solutions is not useful as an analytical signal, because it is highly affected by hydrogen evolution in acid media and appears as a small peak located at more negative potential values in alkaline media. A new and highly sensitive reduction peak (E(p)=-0.45, pH 9.25) appears, however, after addition of trace amounts of PHQ to Cu(II), or vice versa. This reduction peak is a result of the reduction of Cu(II) chelates in the PHQ-Cu(II) complex and is highly promising for the trace determination of PHQ at nanomolar and submicromolar levels. The response current (I(p)/mu A) for the reduction peak of Cu(II) chelates in a PHQ-Cu(II) matrix results in sensitivity to the concentration of PHQ at least three orders of magnitude higher than that for the reduction peak of PHQ alone under the same conditions. The limit of detection is as low as 5.264 ppb (microg L(-1)). The effect of a variety of anions and cations and of an insulating poly(vinyl alcohol) (PVA) matrix has been investigated. Electroactive PHQ-Cu(II) at a level of 0.685% could induce a current of approximately 240 nA in an insulating PVA matrix, suggesting possible application for the preparation of a PHQ-Cu(II)-PVA electroactive composite.

Buffers↗

How experimental design can improve the validation process. Studies in pharmaceutical analysis.

A critical discussion about the possibility of improving the method validation process by means of experimental design is presented. The reported multivariate strategies concern the evaluation of the performance parameters robustness and intermediate precision, and the optimisation of bias and repeatability. In particular, accuracy and precision improvement constitutes a special subset of experimental design in which the bias and the relative standard deviation of the assay are optimised. D-optimal design was used in order to plan experiments for this aim. The analytical methods considered were capillary electrophoresis, HPLC, adsorptive stripping voltammetry and differential pulse polarography. All methods were applied to real pharmaceutical analysis problems.

Adsorption↗

Rapid determination of telmisartan in pharmaceuticals and serum by the parallel catalytic hydrogen wave method.

The polarographic characteristics of telmisartan have been investigated in 0.8 mol L(-1) NH3.H2O-NH4Cl (pH 8.9)-0.01 mol L(-1) H2O2 as supporting electrolyte. The results demonstrate that the polarographic reduction wave at ca. -1.30 V in the absence of H2O2 is a catalytic hydrogen wave, and the reduction wave enhanced by H2O2 is a so-called parallel catalytic hydrogen wave. The analytical sensitivity of the parallel catalytic hydrogen wave is ca. 60 times higher than that of the corresponding catalytic hydrogen wave. Based on the parallel catalytic hydrogen wave a novel method has been developed for determination of telmisartan by linear sweep polarography. The calibration curve is linear in the range 2.0x10(-8)-2.0x10(-6) mol L(-1) and the detection limit is 1.0x10(-8) mol L(-1). The precision is excellent with relative standard deviations of 2.6% at a concentration of 1.0x10(-7) mol L(-1) telmisartan. The proposed method has been applied to the direct determination of the telmisartan in capsule forms and biological samples. The proposed method has been proved to be advantageous over existing CZE and MEKC methods in simplicity, rapidity, and reproducibility.

Antihypertensive Agents↗

Rapid determination of mono and dinitrophenols by DPP, in the presence of lead and cadmium and using concentrated CaCl2 electrolyte.

The contamination of drinking water and industrial wastewaters is a critical environmental problem. The nitrophenol, dinitrophenol, cadmium, and lead contaminants are classified as hazardous compounds. Their rapid determination may be obtained using differential pulse polarography with concentrated electrolyte. CaCl2, which is very soluble to levels exceeding 5 mol l(-1), allows separation of coalescent peaks at 0.1 mol l(-1). A systematic study undertaken from 0.1 to 5 mol l(-1) shows good separation of lead and cadmium from the organic compounds, and optimization of the electrolyte concentration according to the objective is described. Preconcentration of real samples is necessary because pollution levels are usually very low.

Cadmium↗

Oil-in-water emulsions as suitable working media for the direct polarographic determination of aziprotryne and desmetryne from its organic extracts in water samples.

The electroanalytical behavior of the reduction of the herbicides aziprotryne (2-azido-4-isopropylamino-6-methylthio-1,3,5-triazine) and desmetryne (4-isopropylamino-6-methylamino-2-methylthio-1,3,5-triazine) in oil-in-water emulsions is reported. This medium allows the differential pulse polarographic determination of these s-triazines directly from their sample extracts in an appropriate organic solvent. Sodium pentanesulfonate was chosen as the most suitable surfactant to be used as emulsifying agent, whereas ethyl acetate was selected as the organic solvent to form the emulsions. The peak current was maximum in a 0.3 mol L(-1) HClO4 medium of the continuous aqueous phase for aziprotryne, and at pH 3.0 for desmetryne, and the potential became more negative as the pH increased for both herbicides. The limiting current is diffusion controlled and the electrode process is irreversible. Four electrons are involved in the overall electrochemical reduction process as determined by controlled potential coulometry, whereas the alpha n(a) values suggested that two electrons are involved in the rate-determining step. Using differential pulse polarography, aziprotryne and desmetryne can be determined in the emulsified medium over the concentration ranges 1.0 x 10(-7)-1.0 x 10(-4) mol L(-1), with limits of detection of 4.5 x 10(-8) mol L(-1) and 6.6 x 10(-8) mol L(-1), respectively. The method was applied to the determination of aziprotryne and desmetryne in spiked irrigation water. At concentration levels of 6.0 x 10(-7) mol L(-1) aziprotryne and 4.0 x 10(-7) mol L(-1) desmetryne, recoveries of 94 +/- 3% and 94 +/- 4%, respectively, were obtained after preconcentration on Sep-Pack C18 cartridges. Finally, partial least-squares regression (PLSR) has been used for treatment of the polarographic data obtained from mixtures of aziprotryne, desmetryne and simazine in oil-in-water emulsions. The size of the calibration set was of 29 samples by ninety two current measurements at different potentials. Prediction of the herbicides concentration within the range 1.0 x 10(-6)-1.0 x 10(-5) mol L(-1) was possible.

Calibration↗

Electrochemical determination of trace amounts of environmentally important dyes.

A number of dyes exhibit genotoxic or ecotoxic properties leading to the need for sensitive and selective methods for their determination. Because of the easy reducibility of dyes, modern polarographic and voltammetric methods (differential pulse polarography on classical dropping mercury electrode, differential pulse voltammetry on hanging mercury drop electrode or adsorptive stripping voltammetry) are suitable for the determination of trace amounts of these substances in the general environment in the vicinity of production plants. The scope and limitations of these methods is reviewed and optimum conditions for recently developed methods are summarized. It is shown that the sensitivity of newly developed polarographic and voltammetric methods is sufficient even for the most demanding applications and their selectivity can be increased by their combination with preliminary separation using thin layer chromatography or liquid extraction.

Coloring Agents↗