PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Sutureless”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Endoscopic stapling technique of esophagodiverticulostomy for Zenker's diverticulum.

We present an endoscopic technique of division of the common wall between the esophagus and the hypopharyngeal (Zenker's) diverticulum. The novelty of the technique, as compared with endoscopic sutureless coagulating methods, consists of stapling the esophageal to the diverticular wall using the Endo-GIA 30 stapler (US Surgical Corp, Norwalk, CT), which protects the neck from any contamination from the digestive lumen and ensures optimal hemostasis of the wound edges. The stapler has been designed such that perforation of the bottom of the diverticulum is not likely. The technique has been applied to 6 patients.

Esophagoscopy↗

New approach to aortic dissection: development of an insertable aortic prosthesis.

We have developed a new aortic prosthesis with which we can replace or reinforce the aorta using a simple percutaneous technique. We have named the new prosthesis the shape-memory aortic prosthesis (SAP); it consists of a spiral-shaped nitinol stent and polyurethane tube. It can be compressed inside a 14F catheter at a low temperature and regain its original shape at above 30 degrees C. As a preliminary study, SAP sutureless grafting into the descending aorta was performed on 10 mongrel dogs. We found that when the proper diameter of SAP was applied, it functioned satisfactorily for 3 months or more. A percutaneous placement technique pertinent to the SAP also was developed and tried on 4 animals. Our procedure was applied to Stanford type B dissection models to close the entry point successfully. This newly developed SAP has potential to be applied to emergency cases of human aortic dissections.

Aortic Dissection↗

Surgical correction of aortic disease using intraluminal, crimped bovine pericardial graft.

We propose the use of a crimped bovine pericardial graft joined to a rigid and grooved ring for the treatment of aortic dissections and aneurysms. This device was developed to support common tubular vascular prostheses of any material, length, diameter, or form, transforming them into intraluminal ones during the surgical procedure. During March 1989 to May 1994, 74 patients underwent an operation on the aorta in which this intraluminal ring, prepared from a tubular prosthesis of bovine pericardium, was used. Twenty-seven patients had an acute type A aortic dissection, 6 had an acute type B aortic dissection, 10 had annuloaortic ectasia, 6 had a descending aortic aneurysm, 3 had a thoracoabdominal aneurysm, and 22 had an abdominal aneurysm. The global mortality rate of 10.8% in the immediate postoperative period cannot be related to the surgical technique or the type of prosthesis used. We conclude from our findings that this modification of the sutureless intraluminal graft, which allows it to be used to replace diseased segments of the aorta, affords the quickest and simplest means of repair and is attended by the least likelihood of anastomotic complications.

Adult↗

Laser assisted fusion of the rat stomach: preliminary studies.

The purpose of this study was (1) to determine whether rat gastrotomies could be securely closed without sutures by CO2 laser-induced tissue fusion alone and (2) to compare some characteristics (physical, biochemical, histological) of laser-fused gastrotomies with sutured gastrotomies. Following pentobarbital anesthesia a 1.5-cm longitudinal anterior gastrotomy was made in the forestomach of male Sprague-Dawley rats. This wound was closed using either a sutureless tissue weld created by a microscope-mounted CO2 laser (153 W/cm2) (Group I, N = 61) or with a running 6-O polypropylene suture (Group II, N = 58). Animals were sacrificed on Postoperative Days 1, 2, 4, 7, and 11 and the wounds were studied. Survival to scheduled sacrifice was 95% in Group I and 93% in Group II. Although bursting pressure of laser-fused gastrotomies was significantly lower than that of sutured controls on Postoperative Day 1, measurement on subsequent days showed comparable wound strength between the laser and suture groups. Wound hydroxyproline content was significantly higher on Postoperative Day 1 and lower on Postoperative Day 11 in the laser group. Histologic examination of the laser-fused wounds revealed less inflammation and earlier reepithelialization than the sutured wounds, giving the microscopic appearance of a "neater" healing wound. These results suggest that laser-induced fusion is a feasible method of gastrointestinal wound closure which may complement standard suture techniques.

Animals↗

Prospects for epidermal growth factor in the management of corneal disorders.

Epidermal growth factor (EGF) is a naturally occurring mitogen which, in its recombinant form, is under intensive investigation for therapeutic use. Receptor activation by EGF induces up-regulation of synthesis of specific proteins as well as proliferation and differentiation of the corneal epithelium, keratocytes, and endothelium both in vivo and in vitro. With topical application of EGF, corneal wounds could possibly heal within hours, and the strength of the stromal scars is also increased; this may lead to the prospect of sutureless surgery. It may be possible to treat degenerative and dystrophic disorders of the cornea, especially of the endothelium, and to enhance the density of endothelial cells in donor corneas prior to transplantation. Combination therapy with EGF, fibroblast growth factor, and corticosteroids may be advantageous in producing a synergistic effect. It is possible that, with increased knowledge of the pharmacokinetics and the development of appropriate delivery systems, EGF could become an integral part of the next generation of ophthalmic pharmaceuticals.

Adrenal Cortex Hormones↗

Oblique sclerotomy technique for prevention of incompetent wound closure in transconjunctival 25-gauge vitrectomy.

PURPOSE: To develop a surgical incisional technique that helps overcome incompetent sclerotomy closure previously reported in sutureless 25-gauge vitrectomy. DESIGN: Prospective interventional case series report. METHODS: We performed this surgical technique in 12 eyes of 12 consecutive patients scheduled for 25-gauge vitrectomy. The sclerotomy was created performing an oblique incision, a structural modification that helps the closure stay watertight once the cannulas are removed. RESULTS: This technical variation resulted in no intraoperative leakage after cannula removal in any of the 36 sclerotomies performed. CONCLUSIONS: Incision construction using this technique may resolve the reported sclerotomy leakage that in some cases had to be solved by suturing.

Conjunctiva↗

Five years' world experience with nonpenetrating clips for vascular anastomoses.

BACKGROUND: A new sutureless technique has been introduced clinically to facilitate the process of vascular reconstruction and improve patency. The Vessel Closure System (VCS) is nonpenetrating, creates an elastomeric everted anastomosis, and is easily and reproducibly applied. The objective of this report is to review the published world experience that has accrued regarding these clips with attention to the assets, liabilities, and pitfalls associated with the new technology. DATA SOURCES: Medline search and manual cross-referencing were performed, after which 61 original articles were identified on the use of VCS clips for vascular anastomoses. RESULTS: Advantages of the clips compared with sutures include the technical ease of application, the reduced anastomotic time, the superior hemodynamics, and the improved healing pattern of the anastomosis. Disadvantages include the potential problems in atherosclerotic vessels, lack of prospective randomized long-term follow-up, and initial costs. The best clinical results have been achieved in microvascular repair, as well as with vascular access and transplantation surgery. CONCLUSIONS: The VCS clip technology has become an accepted vascular anastomosing technique, which in future could lead to the use of clips as a standard approach and the use of sutures only in case of severe atherosclerosis and other circumstances in which vessel edges are difficult to evert.

Anastomosis, Surgical↗

Cyclic loading of rotator cuff repairs: an in vitro biomechanical comparison of bioabsorbable tacks with transosseous sutures.

PURPOSE: This study compares rotator cuff repair strength after cyclic loading of bioabsorbable tacks and traditional transosseous sutures, and correlates the results with bone density, age, and gender. The hypotheses were that tack repair strength would be inferior to transosseous sutures and that repair strength would be directly related to bone quality. TYPE OF STUDY: In vitro randomized biomechanical study. METHODS: Eight paired cadaveric shoulders with a standardized supraspinatus defect were randomized to tack or suture repair and subjected to step-wise cyclic loading. Repair migration was measured by quantifying the motion of markers affixed to tendon and bone using a digital camera. Failure mode, cycles, and load were measured for 50% and 100% loss of repair. Results were correlated with bone density, age, and gender. RESULTS: Tack repairs failed at the tack-tendon interface, whereas suture rupture was the mode of failure for the suture repairs. Mean values for 50% loss of repair were 206 +/- 88 cycles and 44 +/- 15 N for the sutures, and 1,193 +/- 252 cycles and 156 +/- 20 N for the tacks (P < .05). The corresponding values for 100% loss of repair were 2,458 +/- 379 cycles and 294 +/- 27 N for the sutures, and 2,292 +/- 333 cycles and 263 +/- 28 N for the tacks (P > .05). These results did not correlate with bone density, age, or gender. CONCLUSIONS: This study has shown that bioabsorbable tacks provide improved repair strength in comparison with traditional suture techniques. Repair strength did not correlate with bone quality, and this may be attributed to failure primarily through the repair construct or at the tack-tendon interface and not through bone. This report describes a new high-resolution optical method of measuring tendon repair strength that should be a useful model for future studies. CLINICAL RELEVANCE: This study demonstrates the biomechanical advantages of a sutureless tack device for rotator cuff repair compared with a traditional augmented suture repair technique.

Absorbable Implants↗

Experimental study of one-shot vascular anastomostic device for proximal vein graft anastomoses.

PURPOSE: A new type of sutureless aortic-vein-graft vascular anastomostic device, One-Shot Vascular Anastomostic Device (Horologe Factory of Jinan City, Shandong Province, China) has been recently designed to create a one-shot anastomosis between the aorta and vein grafts for coronary artery bypass grafting surgery. DESCRIPTION: Twelve pigs were scheduled for the test of the feasibility of the One-Shot Vascular Anastomostic Device for artery to vein graft anastomosis. In each animal one proximal anastomosis was performed by means of the One-Shot Vascular Anastomostic Device and the distal end was sutured in a conventional manner to serve as the animal own control. The anastomosis incorporating the abdominal main artery to the segment of a free external carotid vein to the external iliac artery is for the simulation of the aorta-vein anastomosis. EVALUATION: The mean duration of the completion of the proximal anastomosis was 1.2 +/- 1.2 minutes (range, 0.3-5.0 minutes). There was a significant difference between the control groups (p < 0.01). All vein grafts were still functioning at the end of the procedure. Pathologic studies and angiography demonstrated that the results were satisfactory. CONCLUSIONS: This device enables rapid and safe completion of vascular anastomostic procedure. The vein graft was functioning well and incorporated into the vessel intima smoothly.

Animals↗

First clinical results with a 30 degrees end-to-side coronary anastomosis coupler.

OBJECTIVE: The purpose of this study is to evaluate the safety and efficacy of a novel 30 degrees end-to-side coronary anastomotic coupler (Converge Medical, Inc., Sunnyvale, CA) that facilitates a non-penetrating, sutureless vein graft to coronary artery anastomosis. MATERIAL AND METHODS: The Coupler utilizes a set of concentric mating frames approximating adjacent vessel tissue allowing for biological healing of the anastomosis. The frames are manufactured from Nitinol, a nickel titanium super-elastic metal alloy. The Nitinol frames attach the bypass graft to the coronary artery in a 30 degrees end-to-side configuration. Between November 2002 and March 2003 a total of 46 patients (44 male) with a mean age of 63.6+/-7.5 years were admitted for coronary artery revascularization and included in the study. The mean LVEF was 60.6+/-12.4%. RESULTS: Thirty-three patients were successfully treated with the Coupler. Nine patients did not meet the intraoperative inclusion criteria, and were excluded from the study due to small (<or=2.0mm) or severely calcified coronary vessels, or small vein grafts. Hemostasis could not be achieved with the Coupler in 3 patients, and in one patient the graft flow measured intraoperative was low. In these instances the Coupler was removed and the anastomosis was sutured without complication. Average mean flow rate using transit time method through the Coupler attached bypasses was 54+/-26ml/min. In a control angiography 2 months after surgery, 29 (96.7%) of the 30 connector grafts were patent. One stenosis of 50% occurred on the site of a connector anastomosis. Angiographic patency assessments for 81 hand sewn grafts revealed 73 (90.1%) patent grafts. CONCLUSION: Initial results indicate that the Converge Coupler can be used to create a safe and effective 30 degrees vein graft to coronary artery anastomosis under suitable conditions.

Aged↗

Severe ostial saphenous vein graft disease leading to acute coronary syndromes following proximal aorto-saphenous anastomoses with the symmetry bypass connector device: is it a suture device or a "stent"?

The Symmetry Bypass Connector (St. Jude Medical, St. Paul, Minnesota) is a nitinol, star-shaped device that was designed to facilitate placement of sutureless aorto-saphenous anastomoses during off-pump coronary artery bypass graft surgery (CABG). Although the device is approved for clinical use in Europe and the U.S., its short- and long-term safety and efficacy are not established. We report on 5 of 121 patients undergoing CABG who presented with an acute coronary syndrome two to five months following placement of this device. In each patient, all saphenous vein grafts (SVGs) placed (n = 11) with the device were totally occluded (n = 6) or compromised by ostial stenoses (n = 5). Treatment consisted of repeat CABG in one patient and percutaneous coronary intervention (PCI) in four patients with cutting balloon atherotomy and stenting. Following PCI, two of four patients presented again within two months with near-occlusive ostial restenosis in all stents placed. Intracoronary ultrasound showed severe neointimal hyperplasia, but only at the proximal interface of the device and stent. One patient was treated with brachytherapy in two SVGs but had a recurrence four months later and was treated with drug-eluting stents in both restenotic segments. Recalcitrant neointimal hyperplasia is postulated to be involved in the pathogenesis of anastomotic device stenosis, possibly similar to in-stent restenosis. Prospective randomized clinical trials are needed to assess the clinical safety and efficacy of this device. Pending such studies, consideration should be given in limiting its use to cases of unacceptably high risk of stroke during aortic cross-clamping. Dual antiplatelet agents, evaluation for ischemia, and close follow-up are warranted in patients that have already received the device.

Acute Disease↗

Unusual presentation of angle-closure glaucoma treated by phacoemulsification.

We report the case of a 70-year-old woman with a history of acute primary angle-closure glaucoma (PACG) in the left eye who, 2 hours after a fundus examination and mydriasis, experienced acutely elevated intraocular pressure (IOP) up to 40 mm Hg in the presence of fully dilated pupil and a patent iridotomy. Gonioscopy revealed appositional angle closure in 3 quadrants. After medical control of the IOP, sutureless cataract surgery was performed, including clear corneal incision, phacoemulsification, and soft acrylic posterior chamber intraocular lens (IOL) implantation. Eighteen months after the operation, improvement of visual acuity, widening of anterior chamber angle, and deepening of anterior chamber depth were found. Intraocular pressures are now normal without medication, even after mydriasis. Modern cataract surgery is an effective treatment for selected patients with appositional angle closure and IOP elevation after acute PACG.

Acute Disease↗

Cohort study of 27 cases of endophthalmitis at a single institution.

PURPOSE: To identify potential risk factors associated with post-cataract surgery bacterial endophthalmitis. SETTING: The John A. Moran Eye Center, Salt Lake City, Utah, USA. METHODS: This retrospective cohort study consisted of patients who had surgery for cataract(s) at this eye hospital. A 10% sampling of all patients operated on for cataract surgery from January 1, 1996, to December 31, 2002, were compared with all cases of postcataract surgery bacterial endophthalmitis during this same time period at this institution. The main outcome measure(s) included surgical complication, first postoperative day wound leak, incision placement and location, intraocular lens material, whether a suture was placed, antibiotic used, collagen shield use, and whether the eye was patched. RESULTS: A total of 1525 patients were in the control cohort, and there were 27 cases of endophthalmitis. In a multivariate regression analysis, the factors found to be statistically associated with endophthalmitis were (1) wound leak on the first postoperative day (odds ratio [OR] 44 +/- 42; confidence interval [CI] 6.85 to 287; P<.001); (2) capsular or zonular surgical complication (OR 17.2 +/- 14.2; CI 3.44 to 86.4; P=.001); (3) topical antibiotic started the day after surgery rather than the day of surgery (OR 13.7 +/- 12.9; CI 2.17 to 90.9; P=.005); (4) use of ciprofloxacin rather than ofloxacin topically after surgery (OR 5.3 +/- 3.6; CI 1.41 to 20.0; P=.014); (5) not patching after surgery (OR 7.1 +/- 5.6; CI 1.47 to 36.4; P=.015); and (6) not placing a collagen shield soaked in antibiotic (OR 2.7 +/- 1.3; CI 1.06 to 7.14 P=.037). CONCLUSION: In sutureless cataract surgery, surgical complications and wound leak on the first postoperative day were most strongly associated with endophthalmitis.

Aged↗

Sequential argon-YAG laser membranectomy and phacoemulsification for treatment of persistent pupillary membrane and associated cataract.

We report a case of a persistent pupillary membrane (PPM) associated with a cataract managed by sequential argon-YAG laser membranectomy and phacoemulsification. A 30-year-old woman had an extensive PPM and anterior capsular opacity of the lens in the right eye. Best corrected visual acuity (BCVA) was 20/60. Argon laser photocoagulation was performed at the junction of the PPM and the iris collarette. Subsequently, a neodymium:YAG laser was used to sever the strands of the PPM. These laser procedures resulted in shrinkage of the PPM without hemorrhage in the iris or other complications. The patient had clear corneal sutureless phacoemulsification uneventfully on the next day. The BCVA improved to 20/25 3 months following the treatment. We conclude that combined sequential argon-YAG laser membranectomy and modern phacoemulsification surgery can effectively be used to treat PPM associated with cataract without bleeding of the iris or other major side effects.

Adult↗

Bacterial contamination in the anterior chamber after povidone-iodine application and the effect of the lens implantation device.

PURPOSE: To assess the incidence of anterior chamber bacterial contamination during cataract surgery, and compare results of injector implantation and forceps implantation of foldable intraocular lenses (IOLs). SETTING: Department of Ophthalmology and Institute of Medical Microbiology, Semmelweis University, Budapest, Hungary. METHODS: This prospective randomized controlled clinical study comprised 97 eyes of 96 patients. Antibiotic eyedrops were not used; however, povidone-iodine 10% solution was used to prepare the eyebrow and eyelids and povidone-iodine 5% to disinfect the ocular surface. A Steri-Drape (3M) was used to surround the eye. Aqueous fluid samples were aspirated from the anterior chamber at the beginning and the end of surgery. The samples were cultured for 14 days under aerobic and anaerobic conditions simultaneously. Cataract surgery was performed using a sutureless, superotemporal, clear corneal phacoemulsification technique. The IOL was implanted with an injector (n = 47) or a forceps (n = 50), with the instrument randomly selected. The frequency of positive bacterial cultures with each implantation method was compared using the Fisher exact test. RESULTS: Bacteria were found in the conjunctival samples in 21 eyes (21.65%) before povidone-iodine application and in 4 eyes (4.12%) after disinfection. The anterior chamber sample before surgery was culture positive for Staphylococcus epidermidis in 2 eyes and for Micrococcus luteus in 1 eye. After surgery, the culture was positive for S epidermidis in 1 eye (2.15%) in the injector group and 1 eye (2.00%) in the forceps group (P = .74). Neither sample came from an eye that had a positive culture preoperatively. There were no intraoperative complications. CONCLUSIONS: In uneventful clear corneal phacoemulsification, meticulous technique can prevent antibiotic use during surgery. No difference in anterior chamber bacterial contamination was found between IOL implantation using an injector or a forceps.

Adult↗

Intraocular ophthalmic ointment following clear corneal phacoemulsification: Clinical implications.

We report 4 cases of apparent ophthalmic ointment in the anterior chamber after sutureless clear corneal phacoemulsification and posterior chamber intraocular lens implantation. The cases, as well as previous literature, indicate that ointment for topical use can be well tolerated in the eye, although glaucoma and uveitis can be potential negative outcomes. Possible risk factors, some of which may be related to current rates of endophthalmitis after clear corneal cataract surgery, and methods to prevent intraocular ophthalmic ointment after cataract surgery are discussed.

Anterior Chamber↗

Automated distal coronary bypass with a novel magnetic coupler (MVP system).

OBJECTIVE: We sought to assess the feasibility of performing sutureless distal coronary artery bypass anastomoses with a novel magnetic coupling device. METHODS: From May 2000 to April 2001, single-vessel side-to-side coronary artery bypass grafting on a beating heart was performed in 39 domestic white pigs (35-60 kg) without the use of mechanical stabilization, shunts, or perfusion bridges. Animals were divided into 2 groups. Seventeen pigs underwent right internal thoracic artery to right coronary artery bypass grafting through a median sternotomy (group 1) with a novel magnetic vascular positioning system (MVP system; Ventrica, Inc, Fremont, Calif). Twenty-two pigs underwent left internal thoracic artery to left anterior descending artery grafting with the MVP anastomotic device through a left anterior minithoracotomy (group 2). This system consists of 2 pairs of elliptical magnetic implants and a deployment device. One pair of magnets forms the anastomotic docking port within the graft; the other pair forms an identical anastomotic docking port within the target vessel. The anastomosis is created when the 2 docking ports magnetically couple. Anastomotic patency was evaluated by means of angiography during the first postoperative week and at 1 month. Histologic studies were performed at different time points as late as 6 months. RESULTS: Right internal thoracic artery to right coronary artery anastomoses and left internal thoracic artery to left anterior descending artery anastomoses were successfully performed with the system in all animals. The self-adherent and self-aligning properties of the implants allowed for immediate and secure approximation of the arteries (total anastomotic time between 2-3 minutes). Anastomoses were constructed without a stabilization platform. Five nondevice-related deaths occurred postoperatively. One-week angiography, performed in 35 surviving animals, showed a patent graft and anastomosis in all cases. The patency rate at 1 month was 97% (33/34). Histologic studies as late as 6 months demonstrated neointimal coverage of the magnets without any significant luminal obstruction. Histology also confirmed the presence of viable tissue between magnets. CONCLUSION: The MVP anastomotic system uses magnetic force to create rapid and secure distal coronary artery anastomoses, which might facilitate minimally invasive and totally endoscopic coronary artery bypass surgery.

Anastomosis, Surgical↗