PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Volatile Organic Compounds”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Catalytic combustion of volatile organic compounds.

Despite the success of adsorption and thermal incineration of (C)VOC emissions, there is still a need for research on techniques which are both economically more favorable and actually destroy the pollutants rather than merely remove them for recycling elsewhere in the biosphere. The catalytic destruction of (C)VOC to CO2, H2O and HCl/Cl2 appears very promising in this context and is the subject of the present paper. The experiments mainly investigate the catalytic combustion of eight target compounds, all of which are commonly encountered in (C)VOC emissions and/or act as precursors for the formation of PCDD/F. Available literature on the different catalysts active in the oxidation of (C)VOC is reviewed and the transition metal oxide complex V2O5-WO3/TiO2 appears most suitable for the current application. Different reactor geometries (e.g. fixed pellet beds, honeycombs, etc.) are also described. In this research a novel catalyst type is introduced, consisting of a V2O5-WO3/TiO2 coated metal fiber fleece. The conversion of (C)VOC by thermo-catalytic reactions is governed by both reaction kinetics and reaction equilibrium. Full conversion of all investigated VOC to CO2, Cl2, HCl and H2O is thermodynamically feasible within the range of experimental conditions used in this work (260-340 degrees C, feed concentrations 30-60 ppm). A first-order rate equation is proposed for the (C)VOC oxidation reactions. The apparent rate constant is a combination of reaction kinetics and mass transfer effects. The oxidation efficiencies were measured with various (C)VOC in the temperature range of 260-340 degrees C. Literature data for oxidation reactions in fixed beds and honeycomb reactors are included in the assessment. Mass transfer resistances are calculated and are generally negligible for fleece reactors and fixed pellet beds, but can be of importance for honeycomb monoliths. The experimental investigations demonstrate: (i) that the conversion of the hydrocarbons is independent of the oxygen concentration, corresponding to a zero-order dependency of the reaction rate; (ii) that the conversion of the hydrocarbons is a first-order reaction in the (C)VOC; (iii) that the oxidation of the (C)VOC proceeds to a higher extent with increasing temperature, with multiple chlorine substitution enhancing the reactivity; (iv) that the reaction rate constant follows an Arrhenius dependency. The reaction rate constant kr (s(-1)) and the activation energy E (kJ/mol) are determined from the experimental results. The activation energy is related to the characteristics of the (C)VOC under scrutiny and correlated in terms of the molecular weight. The kr-values are system-dependent and hence limited in design application to the specific VOC-catalyst combination being studied. To achieve system-independency, kr-values are transformed into an alternative kinetic constant K (m3/(m2u)) expressed per unit of catalyst surface and thus independent of the amount of catalyst present in the reactor. Largely different experimental data can be fitted in terms of this approach. Results are thereafter used to define the Arrhenius pre-exponential factor A*, itself expressed in terms of the activation entropy. Destruction efficiencies for any given reactor set-up can be predicted from E- and A*-correlations. The excellent comparison of predicted and measured destruction efficiencies for a group of chlorinated aromatics stresses the validity of the design approach. Since laboratory-scale experiments using PCDD/F are impossible, pilot and full-scale tests of PCDD/F oxidation undertaken in Flemish MSWIs and obtained from literature are reported. From the data it is clear that: (i) destruction efficiencies are normally excellent; (ii) the efficiencies increase with increasing operating temperature; (iii) the higher degree of chlorination does not markedly affect the destruction efficiency. Finally, all experimental findings are used in design recommendations for the catalytic oxidation of (C)VOC and PCDD/F. Predicted values of the a)VOC and PCDD/F. Predicted values of the acceptable space velocity correspond with the cited industrial values, thus stressing the validity of the design strategy and equations developed in the present paper.

Catalysis↗

Inclusion of Volatile Organic Compounds into Natural Cyclodextrins and Their Branched Cyclodextrins in the Gaseous Phase

The adsorption isotherms of water, the differential heat of adsorption, and the entropy of adsorbed water were investigated to elucidate the structure of stability of cyclodextrins (CyD) and branched CyD's. The amount adsorbed on branched CyD's increased with increasing relative humidity. The steep rise in the amount adsorbed at higher relative humidities indicated that the structure of branched CyD's was affected by the water molecules at these higher relative humidities. The bonding force between alpha-CyD's and water molecules was stronger than that between their branched CyD's and water, while that between beta-CyD's and water was weaker than that between their branched CyD's and water. We have used activated carbons for the recovery of organic solvents. There are polar groups on the activated carbon surface. Therefore, the recovered organic solvents were degraded by these groups. However, such polar groups are not expected for the hydroxyl groups of the CyD's. The amounts of 1,1,1-trichloroethane, benzene, and toluene included in natural CyD's and their branched CyD's were measured. The amounts of organic solvents included in the CyD's depended upon the cavity radii and the glucosyl and maltosyl functional groups of the CyD's and the radii of the organic solvent molecules.

Journal Article↗

Location and characterization of emission sources for airborne volatile organic compounds inside a refinery in Taiwan.

This study aimed to locate VOC emission sources and characterized their emitted VOCs. To avoid interferences from vehicle exhaust, all sampling sites were positioned inside the refinery. Samples, taken with canisters, were analyzed by GC-MS according to TO-14 method. The survey period extended from Febrary 2004 to December 2004, sampling twice per season. To interpret a large number of VOC data was a rather difficult task. This study featured using ordinary application software, Excel and Surfer, instead of expensive one like GIS, to overcome it. Consolidating data into a database on Excel facilitated retrieval, statistical analysis and presentation in the form of either table or graph. The cross analysis of the data suggested that the abundant VOCs were alkanes, alkenes, aromatics and cyclic HCs. Emission sources were located by mapping the concentration distribution of these four types of VOCs in terms of contour maps on Surfer. During eight surveys, five emission sources were located and their VOCs were characterized.

Air Pollutants↗

Influence of relative humidity and ozone on the sampling of volatile organic compounds on carbotrap/carbosieve adsorbents.

By using a dynamic dilution system, the atmospheric measurement of 11 selected toxics VOCs (ethylene, acetylene, propene, 1-butene, 1,3-butadiene, 1-pentene, 1-hexene, benzene, toluene, ethylbenzene, m+p-xylene) from the list WHO of 1996 and TO-14 method of US EPA by preconcentration by thermal desorption (TD), analysis by gas chromatography (GC), identification and quantification with a flame ionisation detector (FID) was developed and validated in term of metrology, especially the techniques of sampling of these VOCs with adsorbents cartridges "Air Toxics" when used with an "UMEG sampler" equipped in the inlet with a nafion membrane. In particular the influence of climatic conditions (temperature and relative humidity) and the influence of chemical factors like ozone, on the representativity of sampling were studied. Experiments made with various humidities showed that the addition of a nafion membrane in the inlet of the sampling system was required. Without this membrane, losses of compounds were observed for RH >50%. With this membrane, storage for 2 weeks in a refrigerator, as for canisters, did not induce a loss of compounds. No significative decrease of concentrations of the studied VOCs after 14 days storage, which are known to react with ozone, were observed with an ozone concentrations of 55 ppb. One explanation is that nafion membrane, placed in the inlet of the sampler, will neutralize ozone before entering the sampling tubes. This observation is in accordance with literature which states that the sampling of VOCs on Carbotrap cartridges without ozone scrubber induce a loss of compounds.

Adsorption↗

Adsorption characterisation of different volatile organic compounds over alumina, zeolites and activated carbon using inverse gas chromatography.

Adsorption parameters (enthalpy of adsorption, free energy of adsorption) of several alkanes, cyclic hydrocarbons, aromatic hydrocarbons and chlorinated compounds on different adsorbents (alumina, zeolites 13X and 5 A, and activated carbon) were determined by inverse gas chromatography. Dispersive surface energy interaction and specific interaction parameters were determined for each solute-adsorbent system. It was found that mesoporous alumina presents lower enthalpy of adsorption than the microporous materials. Furthermore, zeolite 13X, which has wider pores than zeolite 5 A, exhibits a higher adsorption capacity.

Adsorption↗

Adsorption of volatile organic compounds onto carbon nanotubes, carbon nanofibers, and high-surface-area graphites.

The adsorption of different alkanes (linear and cyclic), aromatics, and chlorohydrocarbons onto different nonmicroporous carbons--multiwalled carbon nanotubes (CNTs), carbon nanofibers (CNFs), and high-surface-area graphites (HSAGs)--is studied in this work by inverse gas chromatography (IGC). Capacity of adsorption was derived from the isotherms of adsorption, whereas thermodynamic properties (enthalpy of adsorption, surface free energy characteristics) have been determined from chromatographic retention data. HSAGs present the highest adsorption capacity, followed by CNTs and CNFs (although CNTs present an intermediate surface area between the two HSAG studied). Among the different adsorbates tested, benzene exhibits the highest adsorption capacity, and the same trend is observed in the enthalpy of adsorption. From surface free energy data, enthalpies of adsorption of polar compounds were divided into dispersive and specific contributions. The interactions of cyclic (benzene and cyclohexane) and chlorinated compounds (trichloroethylene, tetrachloroethylene, and chloroform) with the surfaces are mainly dispersive over all the carbons tested, CNTs being the material with the highest dispersive contribution, as was deduced also from the entropy parameter. Adsorption parameters were correlated with morphological and chemical properties of the materials.

Journal Article↗

Chemesthesis from volatile organic compounds: Psychophysical and neural responses.

In Experiment 1, subjects sought to localize the nostril stimulated, left or right, in tests with nine esters (acetates, propionates, and butyrates) at concentrations meant to trigger chemesthesis (pungency, irritation). The task produced psychometric functions for chemesthetic detection unconfounded by olfactory sensations. The functions indicated a sharp transition from no detection to perfect detection, rather uniform across the esters, which themselves varied in potency by two log units. The correlation between the thresholds for the eight materials that yielded thresholds and predictions from a published linear free energy relationship (LFER) equaled 0.99. In Experiment 2, amplitude of the negative mucosal potential (NMP) was recorded from the septum. The resulting functions also increased with concentration sharply. Against a criterion amplitude of the NMP, thresholds measured in the first experiment (and predictions from the LFER) correlated 0.99. The NMP seems to offer an adequate objective measure of sensory irritation. The LFER, although effective predictively, could stand to have a parameter to anticipate that molecules beyond a certain size fail to trigger irritation. In the present case, a cut-off of chemesthetic potency occurred between butyl butyrate and hexyl butyrate for the group of subjects, with some variation of the boundary among individuals.

Adolescent↗

Seasonal and diurnal variations of volatile organic compounds (VOCs) in the atmosphere of Hong Kong.

Ambient VOCs samples were collected at three locations (PolyU campus (PU), Kwun Tong (KT), Hok Tsui (HT)) in Hong Kong during the periods of November 2000-February 2001 and June 2001-August 2001. Also the concentrations of VOCs in Cross Harbor tunnel in Hong Kong were obtained in order to determine the vehicular sources of VOCs. Toluene was the most abundant VOC detected in Hong Kong. At the PU station, which is close to a main road, the concentrations of most VOCs were higher in summer than in winter. However, at the background location HT, the concentrations of all VOCs except tetrachloroethene were higher in winter than in summer. Regional physical dispersion/transportation and mixing depth may be the reasons for higher VOC concentrations in winter at HT. The BTEX (benzene:toluene:ethylbenzene:xylene) ratios of PU and KT during winter period were (1.9:10.1:1.0:1.8) and (1.9:10.4:1.0:1.5), and (0.9:8.3:1.0:2.2) and (0.8:29.6:1.0:1.8) for summer season, respectively. The xylene/ethylbenzene (X/E) ratio was used to assess the relative age of the air parcels in this study. The concentrations of VOCs in the atmosphere in Hong Kong were mainly affected by direct emissions from vehicles, evaporation of fuels, photochemical reactions and few industrial emissions. The BTEX ratio in the tunnel was 2:10.4:1:3.2. The BTEX ratios at PU and KT during the winter period were similar to that in tunnel (except for xylenes). The X/E ratio in the tunnel was higher than that in the ambient air. This indicated that the freshly emitted xylenes in the tunnel decayed at different rates from OH-oxidation in the atmosphere. Good BTEX correlations (r>0.8) were found at PU and KT in winter (**P<0.01). Vehicular exhaust was the dominant source at PU and KT stations, and less evaporation of fuel or additive occurred at low temperature in winter. Diurnal variations of mean BTEX concentrations at the roadside monitoring station (PU) showed two peaks associated with traffic density and vehicle type.

Journal Article↗

Accumulation of metals, trace elements and semi-volatile organic compounds on exterior window surfaces in Baltimore.

Organic films have been found to develop on window surfaces [Diamond et al., Environmental Science and Technology 34 (2000a) 2900]. The film contains organic compounds that are in dynamic equilibrium with the gas-phase in air, and organic and inorganic compounds and elements associated with deposited air particles. In this study, the exterior surfaces of windows were sampled in downtown and suburban Baltimore, Maryland. Higher concentrations of PCBs, PAH, metals and trace elements were found at downtown than a suburban site. PCBs in the films at downtown sites were dominated by penta and hexa homologue groups and PAH signatures resembled that of vehicle emissions. Twenty-six metals and trace elements were separated into two groups according to their enrichment factors (EF). Ag, Hg, Se, Sb and Zn had EF > 100, suggesting anthropogenic sources of these metals in the films; whereas Fe, Ca, Co, Cr and others had EF <10, suggesting a crustal origin. An unusual profile dominated by deca- and nona- PCBs and relatively higher concentrations of Ag, Hg and Zn may be attributable to emissions from a medical waste incinerator. Dry deposition fluxes of selected metals on windows were 1.4-94 times higher on windows with than without films, indicating that the film increases the dry deposition of particles and their associated chemicals. This implies that film development, which is associated with elevated VOC and SOC emissions to urban air, will increase film development that will, in turn, increase the accumulation of other atmospherically deposited constituents such as metals.

Air Pollutants↗

Slow desorption of volatile organic compounds from soil: evidence of desorption step limitations.

Transient adsorption and desorption of 1,2 dichloroethane and toluene on dry Yolo silt loam soil were studied by continuously measuring the composition of the effluent from a soil-packed chromatography column with a mass spectrometer. After obtaining complete breakthrough at approximately 30% relative saturation of one chemical in nitrogen, pure nitrogen feed was initiated and maintained for several hours. Of the material adsorbed at breakthrough, 9.7% of the 1,2 dichloroethane and 14.2% of the toluene were highly resistant to desorption and remained sorbed on the soil even after 5 h of nitrogen flow. When a second chemical with a higher adsorption affinity was introduced into the soil column (water following toluene or toluene following 1,2 dichloroethane), the majority of the first chemical was quickly desorbed and began leaving the soil column before breakthrough of the second chemical. Conversely, when a second chemical with a smaller adsorption affinity was introduced into the soil column, only a small amount of the first chemical was displaced and began leaving the soil column after breakthrough of the second chemical. The results of this study indicate that the desorption step itself may be the rate-limiting step for sorbate which remains after prolonged exposure to sorbate-free gas.

Adsorption↗

Description of the analysis of a wide range of volatile organic compounds in whole air samples collected during PEM-tropics A and B.

A large number of hydrocarbons, halocarbons, and organic nitrates were quantified in whole air samples acquired for the NASA-sponsored GTE missions PEM-Tropics A and B. The samples were collected in electro-polished stainless steel canisters from two aircraft while flying over the Pacific Basin. Two nominally identical multicolumn multidetector gas chromatographic analytical systems were employed. Whole air samples were also used as working and calibrated standards and were collected specifically for this purpose. This paper describes the analytical procedure employed during PEM-Tropics B. Minor differences in the PEM-Tropics A system will also be discussed. More than 3,900 samples were analyzed for 34 gases during PEM-Tropics A, over 4,500 samples were analyzed for 58 gases during PEM-Tropics B. An overview is presented of the collection, analysis, and quantification of whole air samples during the PEM-Tropics missions, along with an analysis of the analytical precision achieved during these missions.

Journal Article↗