PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Effects of microcystins on phosphorylase-a binding to phosphatase-2A: kinetic analysis by surface plasmon resonance biosensor.

Cyclic heptapeptide microcystins are a group of hepatoxicants which exert the cytotoxic effects by inhibiting the catalytic activities of phosphatase-2A (PP-2A) and phosphatase-1 (PP-1) and thus disrupt the normal signal transduction pathways. Microcystins interact with PP-2A and PP-1 by a two-step mechanism involving rapid binding and inactivation of protein phosphatase catalytic subunit, followed by a slower covalent interaction. It was proposed that inactivation of PP-2A/PP-1 catalytic activity by microcystins precedes covalent adduct formation. In this study, we used a biosensor based on surface plasmon resonance (SPR) to examine the effects of three microcystins, MCLR, MCRR and MCYR, on the binding between PP-2A and its substrate, phosphorylase-a (PL-a), during the first step of the interaction. The SPR biosensor provides real-time information on the association and dissociation kinetics of PL-a with immobilized PP-2A in the absence and presence of microcystins. It was found that the affinity of PL-a to microcystin-bound PP-2A was four times smaller compared to unbound PP-2A, due to 50% decreases in the association rates and two-fold increases in dissociation rates of PL-a binding to PP-2A. The results suggest that the rapid binding of microcystins to the PP-2A catalytic site leads to the formation of a noncovalent microcystin/PP-2A adduct. While the adduct formation fully inhibits the catalytic activity of PP-2A, it only results in partial inhibition of the substrate binding. The similar effects of the three microcystins on PP-2A suggest that the toxins bind to PP-2A at the same site and cause similar conformational changes. The present work also demonstrates the potential application of biosensor technology in environmental toxicological research.

Binding Sites↗

Immunochemical detection of Salmonella group B, D and E using an optical surface plasmon resonance biosensor.

A surface plasmon resonance biosensor (Biacore) was used to detect Salmonella through antibodies reacting with Salmonella group A, B, D and E (Kauffmann-White typing). In the assay designed, anti-Salmonella antibodies immobilized to the biosensor surface were allowed to bind injected bacteria followed by a pulse with soluble anti-Salmonella immunoglobulins to intensify the signal. No significant interference was found for (mixtures of) 30 non-Salmonella serovars at 10(9) CFU ml(-1). A total of 53 Salmonella serovars were successfully detected at 1 x 10(7) CFU ml(-1), except those of groups C, G, L and P, as expected. The cut-off point was determined with an equicellular mixture of Salmonella enteritidis and Salmonella typhimurium at a final amount of 1.7 x 10(3) CFU per test portion. Although further work is needed to cover the detection of all relevant Salmonella serovars in food-producing animals and food products, this work demonstrates the merits of this alternative biosensor approach in terms of automation, sensitivity, specificity, simple handling and limited hands-on time.

Animals↗

On-line supported liquid membrane-liquid chromatography with a phenol oxidase-based biosensor as a selective detection unit for the determination of phenols in blood plasma.

The potential of on-line combination of supported liquid membrane extraction and column liquid chromatography with a phenol oxidase-based biosensor as a selective detection unit has been investigated for the determination of phenols in human plasma. The phenols are selectively extracted into a porous PTFE (polytetraflouroethene) membrane impregnated with a water-immiscible organic solvent and further into an alkaline acceptor phase. Via an ion-exchange interface, the analytes are transferred to a reversed-phase column where they are separated and detected using the biosensor. No sample pretreatment before the extraction, except centrifugation, is made. Due to the high selectivity both in the extraction and in the detection steps and to the fact that the demands on the chromatographic separation are low, a quick separation using an eluent with a low concentration of organic modifier can be made, without affecting the biosensor response. Detection limits below the 50 microg/l level in blood plasma were obtained for the three model compounds, phenol, p-cresol and 4-chlorophenol.

Biosensing Techniques↗

Strategies for the improvement of an amperometric cholesterol biosensor based on electropolymerization in flow systems: use of charge-transfer mediators and platinization of the electrode.

Different configurations based on an amperometric biosensor with cholesterol oxidase entrapped in a polypyrrole film have been developed with a view to improving the analytical properties of this biosensor. The alternatives considered involve the simultaneous entrapment of the enzyme and a charge-transfer mediator as well as previous platinization of the surface of the Pt electrode. Both artificial (a ferrocene derivative) and natural (flavin nucleotides) mediators were studied as constituents of the charge-transfer process between the enzyme and the electrode. The comparative study of these biosensors, which were prepared in situ in a continuous flow system, made it possible to determine the advantages and disadvantages of each configuration when applied to flow-injection determination of cholesterol.

Biosensing Techniques↗

Biosensor analysis of the molecular interactions of pentosan polysulfate and of sulfated glycosaminoglycans with immobilized elastase, hyaluronidase and lysozyme using surface plasmon resonance (SPR) technology.

Pentosan polysulfate (NaPPS) and chondroitin sulfates (ChSs) have recently been shown to exhibit both symptom and disease modifying activities in osteoarthritis (OA), but their respective mechanisms of action are still the subject of conjecture. Excessive catabolism of joint articular cartilage is considered to be responsible for the initiation and progression of OA but the abilities of these drugs to mitigate this process has received only limited attention. Human neutrophil elastase (HNE) is a proteinase, which can degrade the collagens and proteoglycans (PGs) of the cartilage directly or indirectly by activating latent matrix metalloproteinases. Hyaluronidase (HAase) is an endoglycosidase, which degrades glycosaminoglycans including hyaluronan, which provides the aggregating component of the PG aggrecan complex. In the present study the molecular interactions between the NaPPS, ChSs and some other sulfated polysaccharides with immobilized HNE, HAase or lysozyme (a cationic protein implicated in PG metabolism) were studied using a SPR biosensor device-BIAcore2000. The above three enzymes were covalently immobilized to a biosensor chip CM5 separately using amine coupling. The binding affinity of each sulfated polysaccharide and the kinetics of NaPPS over the concentration range of 0.3-5.0 microg/ml were determined. The inhibition of HNE by the sulfated polysaccharides as determined using the synthetic substrate succinyl-Ala-Ala-Val-nitroanilide (SAAVNA) in a functional assay was compared with their respective binding affinities for this proteinase using the BIAcore system. The results obtained with the two independent techniques showed good correlation and indicated that the degree and ring positions of oligosaccharide sulfation were major determinants of enzyme inhibitory activity. The observed difference in order of binding affinities of the drugs to the immobilized HNE, HAase and lysozyme suggests a conformational relationship, in addition to the charge interactions between the sulfate esters of the polysaccharides and the cationic amino acids of the enzymes. Significantly, the SPR biosensor technology demonstrated that small differences among sulfated polysaccharides, even subtle variations among different NaPPS batches, could be readily detected. The SPR technology therefore offers not only a sensitive and reproducible method for ranking noncompetitive enzyme inhibitors for drug discovery but a rapid and quantitative bioassay for monitoring batch consistency of manufacture.

Biosensing Techniques↗

Determination of the antioxidant capacity of samples of different types of tea, or of beverages based on tea or other herbal products, using a superoxide dismutase biosensor.

Research was performed to experimentally evaluate the antioxidant capacity of different plant products sold by herbalists (ginger, dog rose, ginseng and camomile) and of several types of tea (ordinary tea, green tea, detheinated tea, lemon and peach flavoured tea) using a superoxide dismutase (SOD) biosensor recently developed by the present authors. Measurements were carried out by comparing biosensor response to the superoxide radical produced in solution using the xanthine-xanthine oxidase system, both in the presence and absence of the antioxidant sample considered. Precision of antioxidant capacity measures for herbal products and for non diluted samples was good, generally with a R.S.D.%< or =10% and a LOD value about 0.1 for relative antioxidant capacity. Also a "pool" of polyphenols from different tea samples was measured using a tyrosinase biosensor (LOD approximately 2 microM).

Antioxidants↗

Amperometric biosensor based on monoamine oxidase (MAO) immobilized in sol-gel film for benzydamine determination in pharmaceuticals.

The development and application of a flow-through amperometric biosensor for benzydamine determination in anti-inflammatory drugs is described. The biosensor was obtained by physical entrapment of monoamine oxidase in a sol-gel film applied on platinum or carbon paste conducting support. The sol-gel membranes were prepared using an optimum concentration of 3-aminopropyltriethoxy silane, 2-(3,4-epoxycyclohexyl)ethyl-trimethoxy silane, double distilled water saturated with polyethylene glycol 6000 and HCl. The developed biosensors were incorporated in a single channel flow injection system to enable the determination of benzydamine in the concentration range of 0.05-2.5 mmol l(-1) (with platinum based electrode) or within 0.1-2.5 mmol l(-1) (carbon paste based electrode). The operational stability of the bioanalytical system developed was about 3 months permitting approximately 4700 substrate measurements. The flow injection system developed enables a sampling rate of 20-25 samples h(-1) and relative S.D. of results less than 4%. The analytical usefulness of the proposed procedure was evaluated through analysis of commercial pharmaceutical products containing benzydamine, available on the Portuguese market. The results obtained did not differ significantly from the values resulting from analysis of the same products by the method described in the BP Pharmacopoeia.

Benzydamine↗

Amperometric glucose biosensor based on lipid film.

A novel glucose biosensor based on cast lipid film was developed. This model of biological membrane was used to supply a biological environment on the surface of the electrode, moreover it could greatly reduce the interference and effectively exclude hydrophilic electroactive material from reaching the detecting surface. TTF was selected as a mediator because of its high electron-transfer efficiency, and it was incorporated in the lipid film firmly. Glucose oxidase was immobilized in hydrogel covered on the lipid film. The effects of pH, operating potential were explored for the optimum analytical performance by using amperometric method. The response time of the biosensor was less than 20 s, and the linear range is up to 10 mmol l(-1) (corr. coeff. 0.9932) with the detection limit of 2 x 10(-5) mol l(-1). The biosensor also exihibited good stability and reproducibility.

Biosensing Techniques↗

Chemiluminescent choline biosensor using histidine-modified peroxidase immobilised on metal-chelate substituted beads and choline oxidase immobilised on anion-exchanger beads co-entrapped in a photocrosslinkable polymer.

A novel sensing layer design is presented based on the non-covalent immobilisation of enzymes on derivatized Sepharose beads subsequently entrapped in PVA-SbQ photopolymer. Two different modified Sepharose beads were used, IDA- and DEAE-Sepharose, for the immobilisation, respectively, of horseradish peroxidase (HRP) modified with histidine, and choline oxidase (Chx). The HRP-IDA-Sepharose-based sensing layer was used in a flow injection analysis chemiluminescent system as the basis of an H2O2 biosensor. It was shown that the pre-immobilisation on IDA-Sepharose beads enhanced the sensing layer stability and enabled the immobilisation of a larger amount of enzyme. A 1.8 mg charge of HRP-IDA-Sepharose beads in the sensing layer produced the most sensitive H2O2 biosensor. Such an analytical system exhibited very good performances, with a cycle time of 2 min and a detection limit of 15 pmol (detection ranging over four decades at least), and an unusual long operational stability of 200 measurements (CV, 3.5%). The HRP-IDA-Sepharose beads were then combined with Chx-DEAE-Sepharose. With this modified Sepharose-based biosensor the limit of detection for choline (S/N, 3) was equal to 0.5 pmol and the working range was 0.35 pmol-10 nmol. Moreover, the cycle time was only 2.5 min with the new sensing layer, and a long operational stability of 150 successive assays was found, with a variation coefficient of 2.6%.

Alcohol Oxidoreductases↗

Development of a disposable ethanol biosensor based on a chemically modified screen-printed electrode coated with alcohol oxidase for the analysis of beer.

A disposable amperometric biosensor for the measurement of ethanol has been developed. It comprises a screen-printed carbon electrode doped with 5% cobalt phthalocyanine (CoPC-SPCE), and coated with alcohol oxidase; a permselective membrane on the surface acts as a barrier to interferents. The measurement of ethanol is based on the signal produced by H2O2, the product of the enzymatic reaction. Optimisation studies were performed using amperometry in stirred solution and the magnitude of the signal was found to be dependent on pH, enzyme loading, type of membrane and applied potential. The same technique was used to evaluate the biosensor for the determination of ethanol in samples. The results obtained compared well with the manufacturers specifications. In order to test the possibility of using the devices in the field, chronoamperometry was also used to determine ethanol in the same beer samples. The precision and recovery data again indicated that the biosensor should give reliable results under the conditions described.

Alcohol Oxidoreductases↗

Analyte-receptor binding and dissociation kinetics for biosensor applications: a fractal analysis.

A fractal analysis of confirmative nature only is presented for analyte-receptor binding and dissociation kinetics for biosensor applications. Data taken from the literature may be modeled, in the case of binding using a single-fractal analysis or a dual-fractal analysis. The dual-fractal analysis represents a change in the binding mechanism as the reaction progresses on the surface. Relationships are presented for the binding and dissociation rate coefficients as a function of their corresponding fractal dimension, Df or the degree of heterogeneity that exists on the surface. When analyte-receptor binding or dissociation is involved, an increase in the heterogeneity on the surface (increase in Df) leads to an increase in the binding and in the dissociation rate coefficient. It is suggested that an increase in the degree of heterogeneity on the surface leads to an increase in the turbulence on the surface owing to the irregularities on the surface. This turbulence promotes mixing, minimizes diffusional limitations, and leads subsequently to an increase in the binding and in the dissociation rate coefficient (Martin S.J., Granstaff, V.E., Frye, G.C., Anal. Chem., 65, (1991) 2910). The binding and the dissociation rate coefficient are rather sensitive to the degree of heterogeneity, Df,bind and Df,diss respectively, that exists on the biosensor surface. For example, the order of dependence on Df,bind is 19.2 for the binding rate coefficient, kbind for the binding of 0.03-1.0 microM SH-2Ld in solution to 2C TCR immobilized on a surface plasmon resonance (SPR) biosensor (Corr, M., Salnetz, A.E., Boyd, L.F., Jelonek, M.T., Khilko, S., Al-Ramadi, B.K., Kim, Y.S., Maher, S.E., Bothwell, A.L.M., Margulies, D.H., Science, 265, (1994) 946). The order of dependence on Df,diss is -6.22 for the dissociation rate coefficient, kdiss for the dissociation of 250-1000 nM Sophora japonica agglutinin (SJA)-lactose complex from the SPR surface. In general, the technique is applicable to other reactions occurring on different types of surfaces, such as cell-surface reactions.

Biosensing Techniques↗

A facile approach to immobilize protein for biosensor: self-assembled supported bilayer lipid membranes on glassy carbon electrode.

A kind of solid substrate, glassy carbon (GC) electrode, was selected to support self-assembled lipid layer membranes. On the surface of GC electrode, we made layers of dimyristoylphosphatidylcholine (DMPG, a kind of lipid). From electrochemical impedance experiments, we demonstrated that the lipid layers on the GC electrode were bilayer lipid membranes. We immobilized horseradish peroxidase (HRP) into the supported bilayer lipid membranes (s-BLM) to develop a kind of mediator-free biosensor for H2O2. The biosensor exhibited fine electrochemical response, stability and reproducibility due to the presence of the s-BLM. As a model of biological membrane, s-BLM could supply a biological environment for enzyme and maintain its activity. So s-BLM is an ideal choice to immobilize enzyme for constructing the mediator-free biosensor based on GC electrode.

Biosensing Techniques↗

Voltammetric biosensors for the determination of formate and glucose-6-phosphate based on the measurement of dehydrogenase-generated NADH and NADPH.

This paper describes the development of a modified electrode for the electrocatalytic oxidation of beta-nicotinamide adenine dinucleotide (beta-NADH) and beta-nicotinamide adenine dinucleotide phosphate (beta-NADPH) using electropolymerised 3,4-dihydroxybenzaldehyde (3,4-DHB). Two voltammetric biosensors using enzyme-immobilised membranes were constructed for the determination of formic acid and glucose-6-phosphate (G6P), respectively. The formic acid biosensor based on the combination of formate dehydrogenase (FDH)-modified membrane with 3,4-DHB-coated glassy carbon electrode is one to two orders more sensitive (LOD, 5.0x10(-5) M) than previously reported electrochemical biosensors. Similarly, lower detection limit (4.0x10(-5) M) for the measurement of G6P was achieved using glucose-6-phosphate dehydrogenase (G6PDH) in the presence of beta-NADP(+). The interference of uric acid and ascorbate was minimised by incorporating an additional membrane modified with uricase and ascorbate oxidase, respectively. The biosensing scheme developed in this study can be adopted universally with a number of dehydrogenases for the detection of different substrates.

Benzaldehydes↗

Amperometric microbial biosensor for direct determination of organophosphate pesticides using recombinant microorganism with surface expressed organophosphorus hydrolase.

An amperometric microbial biosensor for the direct measurement of organophosphate nerve agents is described. The sensor is based on a carbon paste electrode containing genetically engineered cells expressing organophosphorus hydrolase (OPH) on the cell surface. OPH catalyzes the hydrolysis of organophosphorus pesticides with p-nitrophenyl substituent such as paraoxon, parathion and methyl parathion to p-nitrophenol. The later is detected anodically at the carbon transducer with the oxidation current being proportional to the nerve-agent concentration. The sensor sensitivity was optimized with respect to the buffer pH and loading of cells immobilized using paraoxon as substrate. The best sensitivity was obtained using a sensor constructed with 10 mg of wet cell weight per 100 mg of carbon paste and operating in pH 8.5 buffer. Using these conditions, the biosensor was used to measure as low as 0.2 microM paraoxon and 1 microM methyl parathion with very good sensitivity, excellent selectivity and reproducibility. The microbial biosensor had excellent storage stability, retaining 100% of its original activity when stored at 4 degrees C for up to 45 days.

Aryldialkylphosphatase↗

Use of a thin film biosensor for rapid visual detection of PCR products in a multiplex format.

Rapid, sensitive assays for nucleic acid amplification products have utility for the identification of bacterial or viral infections. We have developed a nucleic acid hybridization assay utilizing thin film technology that permits visual detection of hybrids. The silicon-based biosensor detects the presence of target sequences by enzymatically transducing the formation of nucleic acid hybrids into molecular thin films. These films alter the interference pattern of light on the biosensor surface, producing a perceived color change. We have applied this technology to the development of a chip containing capture probes specific for human respiratory virus sequences including respiratory syncytial virus, influenza virus A and B, parainfluenza virus types 1 and 3, and rhinovirus. In a ten-minute assay, the biosensor permits unambiguous identification of viral-specific RT/PCR products from infected cell lysates.

Base Sequence↗

Polypyrrole-hydrogel composites for the construction of clinically important biosensors.

The present study reports on the use of p(2-hydroxyethyl methacrylate) (pHEMA) in which polypyrrole and various oxidoreductase enzymes were physically entrapped to function as a viable matrix for the construction of clinically important amperometric biosensors. Glucose oxidase, cholesterol oxidase and galactose oxidase biosensors were constructed. Electrode-supported hydrogel films were prepared by UV polymerization of the HEMA component (containing the dissolved enzyme) followed immediately by electrochemical polymerization (+0.7V vs. Ag/AgCl) of the pyrrole component within the interstitial spaces of the pre-formed hydrogel network. The optimized glucose oxidase biosensor displayed a wide linear glucose response range (5.0 x 10(-5) to 2.0 x 10(-2) M), a detection limit (3S(y/x)/sensitivity) of 25 microM and a response time of 35-40 s. The analytical recovery of glucose in serum samples ranged from 98 to 102% with mean coefficients of variation of 4.4% (within-day analyses) and 5.1% (day-to-day analyses). All three sensors displayed good stabilities when stored desiccated in the absence of buffer (>9 months).

Biosensing Techniques↗

Optical biosensor based on nitrite reductase immobilised in controlled pore glass.

The increasing concentration of nitrite in groundwater, rivers and lakes brings serious risks to the public health and to the environment. The aim of this work was the development of an optical biosensor for quantifying nitrite based on the activity of cytochrome cd(1) nitrite reductase immobilised in controlled pore glass (CPG) beads. The developed biosensor operates by measuring the optical reflectance of nitrite reductase, which shows spectroscopic changes when nitrite reversibly binds to the reduced form and oxidizes the enzyme. The optimisation of the immobilisation procedure showed that the immobilisation efficiency is highly dependent on the pH, being very low at basic pH, and that the maximum capacity of the CPG for the immobilisation of cd(1) was estimated in 57+/-10 mg cd(1)/g CPG. The CPG/cd(1) specific activity remained stable at 4 degrees C, decreasing only 10% in 15 days. No observed effects of the immobilisation on the enzyme characteristics were detected, regarding both the red/ox absorbance spectra and the enzyme specific activity, since the red/ox spectra are in good agreement with similar ones obtained for cd(1) in solution, and the specific activity at time zero (0.6 micromoles of NO(2)(-) reduced min(-1) mg of protein(-1)) is similar to that found for the soluble enzyme. The biosensor shows a sensitive response to increasing concentrations of nitrite in solution, especially at 460 nm, at which it showed higher sensitivity. The corresponding detection limit of 0.93 microM is well below the maximum admissible concentration imposed by European Community norms, of 2.2 microM.

Biosensing Techniques↗

Biosensor arrays for simultaneous measurement of glucose, lactate, glutamate, and glutamine.

For simultaneous measurement of glucose, lactate, glutamine, and glutamate a biosensor array is implemented in a micro flow-system thus giving a microsystem. The microsystem consists of a glass chip with the integrated biosensor array and a bottom part, which comprises a gold counter electrode, a 300 microm thick seal, and electrical interconnection lines. The flow device has a total internal volume of 2.1 or 6 microl when integrated with a mixer on chip. The biosensors with no crosstalking and high long term stability were produced by modifying the electrochemical transducers and utilizing photopatternable enzyme membranes. The use of appropriate miniaturization technology leads to mass producable devices for in vivo and ex vivo applications in whole blood and fermentation broth. Due to a novel glutaminase with an activity optimum in the neutral pH range direct and simultaneous monitoring of glutamine together with glucose, lactate, and glutamate could be performed.

Biosensing Techniques↗