PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “systems drift”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Life and death near a windy oasis.

We propose a simple experiment to study delocalization and extinction in inhomogeneous biological systems. The nonlinear steady state for, say, a bacteria colony living on and near a patch of nutrient or favorable illumination ("oasis") in the presence of a drift term ("wind") is computed. The bacteria, described by a simple generalization of the Fisher equation, diffuse, divide A --> A + A, die A --> 0, and annihilate A + A --> 0. At high wind velocities all bacteria are blown into an unfavorable region ("desert"), and the colony dies out. At low velocity a steady state concentration survives near the oasis. In between these two regimes there is a critical velocity at which bacteria first survive. If the "desert" supports a small nonzero population, this extinction transition is replaced by a delocalization transition with increasing velocity. Predictions for the behavior as a function of wind velocity are made for one and two dimensions.

Bacteria↗

Vergence compensation during binocularly- and monocularly-evoked horizontal optokinetic nystagmus in the pigmented rat.

During horizontal optokinetic nystagmus evoked by binocular stimulation in the rat, the slow phases are well-conjugate. The fast phases in the adducting eye are on average about 2 deg greater in amplitude than those of the abducting eye. This causes a transient convergence which is compensated for by a divergent drift within the 100 msec following the fast phase. The amplitudes of these convergence-divergence components fluctuates somewhat from one fast phase to another and their relative amplitudes may differ. As a consequence differences in vergence between successive slow phases may occur. Such differences are usually of small amplitude, but may be as large as 5 deg. When optokinetic nystagmus is evoked by monocular stimulation, the slow phase velocities are different in the two eyes, giving a disjunctive component which is compensated for by a difference in the relative amplitudes and velocities of the fast phases in the two eyes. However, the divergent drift immediately following the fast phases is very similar whatever form of stimulation is employed. It is suggested that during monocularly-evoked optokinetic nystagmus the oculomotor system compensates for the disjunctive component arising during the slow phases by giving a different balance to the pulses of innervation of two eyes, resulting in fast phases of different amplitude.

Animals↗

Efficacy and safety of latanoprost eye drops for glaucoma treatment: a 1-year study in Japan.

PURPOSE: To evaluate the intraocular pressure (IOP)-lowering effect and safety of latanoprost, a prostaglandin analogue, in patients with primary open-angle glaucoma or ocular hypertension. METHOD: One hundred and twenty-four Japanese patients with primary open-angle glaucoma or ocular hypertension were enrolled in this open-labeled study and were treated with 0.005% latanoprost once daily for 1 year. RESULTS: At all follow-up visits there was a significant (P < .001) reduction in IOP compared with the baseline value. After 1 year, the IOP was reduced by 5.4 +/- 2.9 (mean +/- SD) mm Hg from a baseline value of 23.5 +/- 2.2 mm Hg. No evidence of an upward drift in the IOP was observed during the treatment period. The most frequently reported adverse ocular events were mild conjunctival hyperemia and iris pigmentation. Very few adverse systemic events were observed. CONCLUSIONS: Latanoprost eye drops showed a marked and stable IOP-lowering effect during the 1-year treatment period. Furthermore, latanoprost was well-tolerated and should be a valuable contribution to the management of glaucoma.

Adult↗

Analysis of thermohydrologic behavior for above-boiling and below-boiling thermal-operating modes for a repository at Yucca Mountain.

We report results from a multi-scale thermohydrologic modeling study for two alternative thermal-operating modes for the potential repository system recently analyzed by the Yucca Mountain Project. These include a Higher-Temperature Operating Mode (HTOM), which results in a localized boiling zone around each emplacement drift, and a Lower-Temperature Operating Mode (LTOM), which always maintains sub-boiling temperatures throughout the repository. The HTOM places all waste packages nearly end to end, making the lineal power density greater than in the LTOM. The lower lineal power density in the LTOM was achieved by placing some waste packages farther apart (which results in a larger repository footprint), and through an increased reliance on pre-closure ventilation to remove the waste-package-generated heat. We focus on temperature T and relative humidity RH at the waste-package and drift-wall surfaces, and on in-drift evaporation. In general, HTOM temperatures are greater than corresponding LTOM temperatures, exhibit similar spatial variability and have a stronger dependence on infiltration flux. The duration of RH reduction on waste packages is similar for the LTOM and HTOM. A major difference between the LTOM and HTOM is the lower waste-package temperature at any given value of waste-package RH for the LTOM. Waste-package temperatures in the LTOM, by design, remain below approximately 85 degrees C; the absence of RH reduction arising from host-rock dryout causes waste-package RH to remain above about 40%. The HTOM waste packages experience higher temperatures and correspondingly lower RH conditions as a result of RH reduction arising from host-rock dryout. For most of the repository area, the HTOM delays the potential onset of gravity-driven seepage compared to the LTOM (as indicated by the duration of boiling at the drift wall). Boiling conditions in the HTOM also delays the onset of capillary-driven seepage into the granular invert, causing the HTOM to have less evaporation in the invert during the first 800-1500 years than the LTOM; subsequent evaporation rates are higher in the HTOM, due to the higher power density.

Forecasting↗

Short latency ocular-following responses in man.

The ocular-following responses elicited by brief unexpected movements of the visual scene were studied in human subjects. Response latencies varied with the type of stimulus and decreased systematically with increasing stimulus speed but, unlike those of monkeys, were not solely determined by the temporal frequency generated by sine-wave stimuli. Minimum latencies (70-75 ms) were considerably shorter than those reported for other visually driven eye movements. The magnitude of the responses to sine-wave stimuli changed markedly with stimulus speed and only slightly with spatial frequency over the ranges used. When normalized with respect to spatial frequency, all responses shared the same dependence on temporal frequency (band-pass characteristics with a peak at 16 Hz), indicating that temporal frequency, rather than speed per se, was the limiting factor over the entire range examined. This suggests that the underlying motion detectors respond to the local changes in luminance associated with the motion of the scene. Movements of the scene in the immediate wake of a saccadic eye movement were on average twice as effective as movements 600 ms later: post-saccadic enhancement. Less enhancement was seen in the wake of saccade-like shifts of the scene, which themselves elicited weak ocular following, something not seen in the wake of real saccades. We suggest that there are central mechanisms that, on the one hand, prevent the ocular-following system from tracking the visual disturbances created by saccades but, on the other, promote tracking of any subsequent disturbance and thereby help to suppress post-saccadic drift. Partitioning the visual scene into central and peripheral regions revealed that motion in the periphery can exert a weak modulatory influence on ocular-following responses resulting from motion at the center. We suggest that this may help the moving observer to stabilize his/her eyes on nearby stationary objects.

Humans↗

Robust algorithm for alignment of liquid chromatography-mass spectrometry analyses in an accurate mass and time tag data analysis pipeline.

Liquid chromatography coupled to mass spectrometry (LC-MS) and tandem mass spectrometry (LC-MS/MS) has become a standard technique for analyzing complex peptide mixtures to determine composition and relative abundance. Several high-throughput proteomics techniques attempt to combine complementary results from multiple LC-MS and LC-MS/MS analyses to provide more comprehensive and accurate results. To effectively collate and use results from these techniques, variations in mass and elution time measurements between related analyses need to be corrected using algorithms designed to align the various types of data: LC-MS/MS versus LC-MS/MS, LC-MS versus LC-MS/MS, and LC-MS versus LC-MS. Described herein are new algorithms referred to collectively as liquid chromatography-based mass spectrometric warping and alignment of retention times of peptides (LCMSWARP), which use a dynamic elution time warping approach similar to traditional algorithms that correct for variations in LC elution times using piecewise linear functions. LCMSWARP is compared to the equivalent approach based upon linear transformation of elution times. LCMSWARP additionally corrects for temporal drift in mass measurement accuracies. We also describe the alignment of LC-MS results and demonstrate their application to the alignment of analyses from different chromatographic systems, showing the suitability of the present approach for more complex transformations.

Algorithms↗

A reanalysis of protein polymorphism in Drosophila melanogaster, D. simulans, D. sechellia and D. mauritiana: effects of population size and selection.

Comparison of synonymous and nonsynonymous variation/substitution within and between species at individual genes has become a widely used general approach to detect the effect of selection versus drift. The sibling species group comprised of two cosmopolitan (Drosophila melanogaster and Drosophila simulans) and two island (Drosophila mauritiana and Drosophila sechellia) species has become a model system for such studies. In the present study we reanalyzed the pattern of protein variation in these species, and the results were compared against the patterns of nucleotide variation obtained from the literature, mostly available for melanogaster and simulans. We have mainly focused on the contrasting patterns of variation between the cosmopolitan pair. The results can be summarized as follows: (1) As expected the island species D. mauritiana and D. sechellia showed much less variation than the cosmopolitan species D. melanogaster and D. simulans. (2) The chromosome 2 showed significantly less variation than chromosome 3 and X in all four species which may indicate effects of past selective sweeps. (3) In contrast to its overall low variation, D. mauritiana showed highest variation for X-linked loci which may indicate introgression from its sibling, D. simulans. (4) An average population of D. simulans was as heterozygous as that of D. melanogaster (14.4% v.s. 13.9%) but the difference was large and significant when considering only polymorphic loci (37.2% v.s. 26.1%). (5) The species-wise pooled populations of these two species showed similar results (all loci = 18.3% v.s. 20.0%, polymorphic loci = 47.2% v.s. 37.6%). (6) An average population of D. simulans had more low-frequency alleles than D. melanogaster, and the D. simulans alleles were found widely distributed in all populations whereas the D. melanogaster alleles were limited to local populations. As a results of this, pooled populations of D. melanogaster showed more polymorphic loci than those of D. simulans (48.0% v.s. 32.0%) but the difference was reduced when the comparison was made on the basis of an average population (29.1% v.s. 21.4%). (7) While the allele frequency distributions within populations were nonsignificant in both D. melanogaster and D. simulans, melanogaster had fewer than simulans, but more than expected from the neutral theory, low frequency alleles. (8) Diallelic loci with the second allele with a frequency less than 20% had similar frequencies in all four species but those with the second allele with a frequency higher than 20% were limited to only melanogaster the latter group of loci have clinal (latitudinal) patterns of variation indicative of balancing selection. (9) The comparison of D. simulans/D. melanogaster protein variation gave a ratio of 1.04 for all loci and 1.42 for polymorphic loci, against a ratio of approximately 2-fold difference for silent nucleotide sites. This suggests that the species ratios of protein and silent nucleotide polymorphism are too close to call for selective difference between silent and allozyme variation in D. simulans. In conclusion, the contrasting levels of allozyme polymorphism, distribution of rare alleles, number of diallelic loci and the patterns of geographic differentiation between the two species suggest the role of natural selection in D. melanogaster, and of possibly ancient population structure and recent worldwide migration in D. simulans. Population size differences alone are insufficient as an explanation for the patterns of variation between these two species.

Alleles↗

Carbon and oxygen isotope ratios of ecosystem respiration along an Oregon conifer transect: preliminary observations based on small-flask sampling.

Isotope ratio analyses of atmospheric CO(2) at natural abundance have significant potential for contributing to our understanding of photosynthetic and respiration processes in forest ecosystems. Recent advances in isotope ratio mass spectrometry allow for rapid, on-line analysis of small volumes of CO(2) in air, and open new research opportunities at the ecophysiological, whole-organism, and atmospheric levels. Among the immediate applications are the carbon and oxygen isotope ratio analyses of carbon dioxide in atmospheric air. Routine analysis of carbon dioxide in air volumes of approximately 50-300 &mgr;l is accomplished by linking a commercially available, trace gas condenser and gas chromatograph to an isotope ratio mass spectrometer operated in continuous-flow mode. Samples collected in the field are stored in either gas-tight syringes or 100-ml flasks. The small sample volume required makes it possible to subsample the air in flasks for CO(2) and then to sample the remaining air volume for the analysis of the isotopic composition of either methane or nitrous oxide. Reliable delta(13)C and delta(18)O values can be obtained from samples collected and stored for 1-3 days. Longer-term storage, on the order of weeks, is possible for delta(13)C measurements without drift in the isotope ratio signal, and should also be possible for delta(18)O measurements. When linked with an infrared gas analyzer, pump and flask sampling system, it is feasible to sample CO(2) extensively in remote forest locations. The air-sampling system was used to measure the isotope ratios of atmospheric CO(2) and to conduct a regression analysis of the relationship between these two parameters. From the regression, we calculated the delta(13)C of ecosystem respiration of four coniferous ecosystems along a precipitation gradient in central Oregon. The ecosystems along the coast-to-interior Oregon (OTTER) gradient are dominated by spruce-hemlock forests at the wet, coastal sites (> 200 cm precipitation annually) to juniper woodlands (20 cm precipitation) at the interior, dry end of the transect. The delta(13)C values of ecosystem respiration along this transect differed by only 1.3 per thousand (range of -25.2 to -23.9 per thousand ) during August at the peak of the summer drought. Following autumn rains in September, the delta(13)C of ecosystem respiration in the four stands decreased; overall the difference in the carbon isotope ratio of ecosystem respiration among sites increased to 3.9 per thousand (-26.8 to -22.9 per thousand ).

Journal Article↗

Isolation and characterization of Methanomethylovorans hollandica gen. nov., sp. nov., isolated from freshwater sediment, a methylotrophic methanogen able to grow on dimethyl sulfide and methanethiol.

A newly isolated methanogen, strain DMS1(T), is the first obligately anaerobic archaeon which was directly enriched and isolated from a freshwater sediment in defined minimal medium containing dimethyl sulfide (DMS) as the sole carbon and energy source. The use of a chemostat with a continuous DMS-containing gas stream as a method of enrichment, followed by cultivation in deep agar tubes, resulted in a pure culture. Since the only substrates utilized by strain DMS1(T) are methanol, methylamines, methanethiol (MT), and DMS, this organism is considered an obligately methylotrophic methanogen like most other DMS-degrading methanogens. Strain DMS1(T) differs from all other DMS-degrading methanogens, since it was isolated from a freshwater pond and requires NaCl concentrations (0 to 0.04 M) typical of the NaCl concentrations required by freshwater microorganisms for growth. DMS was degraded effectively only in a chemostat culture in the presence of low hydrogen sulfide and MT concentrations. Addition of MT or sulfide to the chemostat significantly decreased degradation of DMS. Transient accumulation of DMS in MT-amended cultures indicated that transfer of the first methyl group during DMS degradation is a reversible process. On the basis of its low level of homology with the most closely related methanogen, Methanococcoides burtonii (94.5%), its position on the phylogenetic tree, its morphology (which is different from that of members of the genera Methanolobus, Methanococcoides, and Methanohalophilus), and its salt tolerance and optimum (which are characteristic of freshwater bacteria), we propose that strain DMS1(T) is a representative of a novel genus. This isolate was named Methanomethylovorans hollandica. Analysis of DMS-amended sediment slurries with a fluorescence microscope revealed the presence of methanogens which were morphologically identical to M. hollandica, as described in this study. Considering its physiological properties, M. hollandica DMS1(T) is probably responsible for degradation of MT and DMS in freshwater sediments in situ. Due to the reversibility of the DMS conversion, methanogens like strain DMS1(T) can also be involved in the formation of DMS through methylation of MT. This phenomenon, which previously has been shown to occur in sediment slurries of freshwater origin, might affect the steady-state concentrations and, consequently, the total flux of DMS and MT in these systems.

Base Sequence↗

A new device for continuous ambulatory central venous pressure measurement.

We have developed a device for continuous direct measurement of human central venous pressure (CVP) during space flight. Normal resting CVP is typically in the range of 5-10 mmHg; in zero gravity, the expected changes are +/- 5 mmHg or less. A 1-mm Hg change in CVP can represent a substantial intravascular fluid shift. The device is small, battery powered, and designed to run for at least 24 hr. Pressure is measured in a saline solution-filled catheter inserted into a central vein. The transducer is placed in the axilla at the level of the catheter tip to offset hydrostatic gradients. A pump and an electronic system mount on the leg. This assembly provides a slow, continuous infusion of heparinized saline solution to maintain the patency of the catheter. The electronic system generates a digital display in mm Hg, an analog output, and a visible and audible alarm for excessive pressure. An air-filled syringe allows for a two-point calibration (zero and a positive pressure generated by measured compression of a known gas volume). A two-failure tolerant system minimizes electric shock hazards. Two latex diaphragms separate the saline solution from the transducer surface, and the electronic system and pump chamber are in separate enclosures. A clear polycarbonate case allows bubbles to be seen. The unit has been tested for pump function, temperature stability, drift, and accuracy. We conclude that this approach provides a unit with sufficient stability, accuracy, and temperature insensitivity for measuring ambulatory CVP for up to 28 hr. The design may be suitable for ambulatory measurement of other intravascular and intracardiac pressures.

Catheterization, Central Venous↗

Establishment of a 24-hour electrocardiogram recording system using a Holter recorder for miniature swine.

A Holter recording system was established for the Göttingen miniature swine. For this purpose, we first developed a jacket to hold a Holter recording set, and subsequently determined a bipolar lead suitable for obtaining stable electrocardiogram (ECG) recording without artifacts. To make the jacket, we measured the lengths of eight sites of the body of 14 miniature swine. Several types of jackets were made and tested. We observed the behaviour of animals with these jackets by videotape recorder (VTR) recording. These observations permitted development of a jacket suitable for Holter recording. The jacket permits easy placement of the recorder, and long-term ECG recording can be performed without difficulty. In order to determine a suitable lead for long-term recording, we recorded ECGs from six adult miniature swine using three types of leads, the M-X, R-L and A-B leads. The R-L lead frequently exhibited baseline drift, and QRS complexes often disappeared in this lead due to low amplitude. ECG recording with the M-X and A-B leads was of sufficient quality to permit analysis. This system is expected to be useful for further cardiovascular research in miniature swine.

Anesthesia↗

Recent climate change in the Arctic and its impact on contaminant pathways and interpretation of temporal trend data.

The Arctic has undergone dramatic change during the past decade. The observed changes include atmospheric sea-level pressure, wind fields, sea-ice drift, ice cover, length of melt season, change in precipitation patterns, change in hydrology and change in ocean currents and watermass distribution. It is likely that these primary changes have altered the carbon cycle and biological systems, but the difficulty of observing these together with sporadic, incomplete time series makes it difficult to evaluate what the changes have been. Because contaminants enter global systems and transport through air and water, the changes listed above will clearly alter contaminant pathways. Here, we review what is known about recent changes using the Arctic Oscillation as a proxy to help us understand the forms under which global change will be manifest in the Arctic. For Pb, Cd and Zn, the Arctic is likely to become a more effective trap because precipitation is likely to increase. In the case of Cd, the natural cycle in the ocean appears to have a much greater potential to alter exposure than do human releases of this metal. Mercury has an especially complex cycle in the Arctic including a unique scavenging process (mercury depletion events), biomagnifying foodwebs, and chemical transformations such as methylation. The observation that mercury seems to be increasing in a number of aquatic species whereas atmospheric gaseous mercury shows little sign of change suggests that factors related to change in the physical system (ice cover, permafrost degradation, organic carbon cycling) may be more important than human activities. Organochlorine contaminants offer a surprising array of possibilities for changed pathways. To change in precipitation patterns can be added change in ice cover (air-water exchange), change in food webs either from the top down or from the bottom up (biomagnification), change in the organic carbon cycle and change in diets. Perhaps the most interesting possibility, presently difficult to predict, is combination of immune suppression together with expanding ranges of disease vectors. Finally, biotransport through migratory species is exceptionally vulnerable to changes in migration strength or in migration pathway-in the Arctic, change in the distribution of ice and temperature may already have caused such changes. Hydrocarbons, which tend to impact surfaces, will be mostly affected by change in the ice climate (distribution and drift tracks). Perhaps the most dramatic changes will occur because our view of the Arctic Ocean will change as it becomes more amenable to transport, tourism and mineral exploration on the shelves. Radionuclides have tended not to produce a radiological problem in the Arctic; nevertheless one pathway, the ice, remains a risk because it can accrue, concentrate and transport radio-contaminated sediments. This pathway is sensitive to where ice is produced, what the transport pathways of ice are, and where ice is finally melted-all strong candidates for change during the coming century. The changes that have already occurred in the Arctic and those that are projected to occur have an effect on contaminant time series including direct measurements (air, water, biota) or proxies (sediment cores, ice cores, archive material). Although these 'system' changes can alter the flux and concentrations at given sites in a number of obvious ways, they have been all but ignored in the interpretation of such time series. To understand properly what trends mean, especially in complex 'recorders' such as seals, walrus and polar bears, demands a more thorough approach to time series by collecting data in a number of media coherently. Presently, a major reservoir for contaminants and the one most directly connected to biological uptake in species at greatest risk-the ocean-practically lacks such time series.

Air Movements↗

Self-organized pacemakers in a coupled reaction-diffusion-mechanics system.

Using a computational model of a coupled reaction-diffusion-mechanics system, we find that mechanical deformation can induce automatic pacemaking activity. Pacemaking is shown to occur after a single electrical or mechanical stimulus in an otherwise nonoscillatory medium. We study the mechanisms underpinning this effect and conditions for its existence. We show that self-organized pacemakers drift throughout the medium to approach attractors with locations that depend on the size of the medium, and on the location of the initial stimulus.

Action Potentials↗

Numerical Solution of the Extended Nernst-Planck Model.

The main features of a numerical model aiming at predicting the drift of ions in an electrolytic solution upon a chemical potential gradient are presented. The mechanisms of ionic diffusion are described by solving the extended Nernst-Planck system of equations. The electrical coupling between the various ionic fluxes is accounted for by the Poisson equation. Furthermore, chemical activity effects are considered in the model. The whole system of nonlinear equations is solved using the finite-element method. Results yielded by the model for simple test cases are compared to those obtained using an analytical solution. Applications of the model to more complex problems are also presented and discussed. Copyright 1999 Academic Press.

Journal Article↗

Training for and maintaining interviewer consistency with the ASI.

A short quiz of Addiction Severity Index (ASI) coding conventions was developed to identify coding inconsistencies within a large group of trained interviewers, as one step in an overall program of quality assurance monitoring. Problem items, in which less than 75% of the quiz respondents answered correctly, existed in almost every ASI section. The ASI quiz has proven helpful in identifying "drift" from the ASI standard procedures. Individually reviewing the results of the quiz with the respondents helped to reinforce the recognized coding rules. The authors discuss a system-wide quality assurance program for maintaining interviewer consistency. It is believed that coding convention measures of this type could be useful in the maintenance of standards in other research interviews and procedures.

Curriculum↗

RESP-24: a computer program for the investigation of 24-h breathing abnormalities in heart failure patients.

In this paper, we describe a computer program (RESP-24) specifically devised to assess the prevalence and characteristics of breathing disorders in ambulant chronic heart failure patients during the overall 24 h period. The system works on a single channel respiratory signal (RS) recorded through a Holter-like portable device. In the pre-processing stage RESP-24 removes noise, baseline drift and motion artefacts from the RS using a non-linear filter, enhances respiratory frequency components through high-pass filtering and derives an instantaneous tidal volume (ITV) signal. The core processing is devoted to the identification and classification of the breathing pattern into periodic breathing (PB), normal breathing or non-classifiable breathing using a 60 s segmentation, and to the identification and estimation of apnea and hypopnea events. Sustained episodes of PB are detected by cross analysis of both the spectral content and time behavior of the ITV signal. User-friendly interactive facilities allow all the results of the automatic analysis procedure to be edited. The final report provides a set of standard and non-standard parameters quantifying breathing abnormalities during the 24 h period, the night-time and the day-time, including the apnea/hypopnea index, the apnea index, the total time spent in apnea or in hypopnea and the prevalence of non-apneic and apneic PB. The accuracy of these measurements was appraised on a data set of 14 recordings, by comparing them with those provided by a trained analyst. The mean and standard deviation of the error of the automatic procedure were below respectively 6 and 8% of the reference value for all parameters considered and the mean total classification accuracy was 92%. In most cases, the individual error was <12%. We conclude that measurements provided automatically by the RESP-24 software are suitable for screening purposes and clinical trials, although a preventive check of signal quality should be recommended.

Apnea↗

Adaptive coordination and alignment of eye and hand.

Under spatial misalignment of eye and hand induced by laterally displacing prisms (11.4 degrees in the rightward direction), subjects pointed 60 times (once every 3 s) at a visually implicit target (straight ahead of nose, Experiment 1) or a visually explicit target (an objectively straight-ahead target, Experiment 2). For different groups in each experiment, the hand became visible early in the sagittal pointing movement (early visual feedback). Adaptation to the optical misalignment during exposure (direct effects) was rapid, especially with early feedback; complete compensation for the misalignment was achieved within about 30 trials, and overcompensation occurred in later trials, especially with an explicit target. In contrast, adaptation measured with the misalignment removed and without visual feedback after blocks of 10 pointing trials (aftereffects) was slow to develop, especially with delayed feedback and an implicit target; at most, about 40% compensation for the misalignment occurred after 60 trials. This difference between direct effects and aftereffects is discussed in terms of separable adaptive mechanisms that are activated by different error signals. Adaptive coordination is activated by error feedback and involves centrally located, strategically flexible, short-latency processes to correct for sudden changes in operational precision that normally occur with short-term changes in coordination tasks. Adaptive alignment is activated automatically by spatial discordance between misaligned systems and involves distributed, long-latency processes to correct for slowly developing shifts in alignment among perceptual-motor components that normally occur with long-term drift. The sudden onset of misalignment in experimental situations activates both mechanisms in a complex and not always cooperative manner, which may produce overcompensatory behavior during exposure (i.e., direct effects) and which may limit long-term alignment (i.e., aftereffects).

Journal Article↗

Ulnar deviation of the fingers as a clinical sign in the elderly.

A significant percentage of elderly women has been found to have ulnar deviation. As measured at the middle finger, the mean deviation of 73 degrees is small, but nearly 25% of subjects showed a clinically visible deviation of between 11 degrees and 25 degrees. Ulnar deviation has been noted in subjects who are not suffering from the diseases and states commonly regarded as being important to its aetiology. In those it may represent the end-point of the progressive drift considered by some to be a normal ageing process. Whether the aetiology lies here or in one of the other diseases of the locomotor or central nervous systems is uncertain, but caution should be used when interpreting the clinical sign in the elderly.

Adult↗