PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “DENTAL RESTORATION, TEMPORARY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

Using transitional implants as fixation screws to stabilize a surgical template for accurate implant placement: a clinical report.

This article describes a method of using transitional implants as surgical fixation screws to orient a surgical template predictably during the placement of implants in the anterior mandible for an implant-supported bar-retained overdenture. Ridge reduction, transitional implant placement, implant placement, and removal of the transitional implants were completed in a single surgical appointment. Details of the template fabrication, incorporating transitional implants and surgical techniques, are described.

Bone Screws↗

Effects of different drinks on stainability of resin composite provisional restorative materials.

STATEMENT OF PROBLEM: The ability of tooth-colored restorative materials for provisional restorations to resist stains is important when interim prostheses are worn for a long period. Discoloration of provisional restorative materials may result in patient dissatisfaction and additional time and expense for replacement. However, the effect of different staining agents on the color difference of resin composite restorative materials has not been completely clarified. PURPOSE: The purpose of this study was to evaluate the stainability of auto- and light-polymerized composite provisional restorative materials, reinforced microfill, and microhybrid resin composite restorative materials upon exposure to different staining agents. MATERIAL AND METHODS: Forty-five cylindrical specimens (15 x 2 mm) were prepared for each of an autopolymerized bis-acryl composite provisional restorative material (Protemp II), a light-polymerized composite provisional restorative material (Revotek LC), a reinforced microfill (Micronew), and a microhybrid composite (Filtek Z250, Herculite XRV) restorative material, using a brass mold. The specimens were wet-ground with 1000-grit silicon carbide abrasive paper for 10 seconds. The 5 restorative material specimens were divided into 9 groups (n = 5) and stored for 24 hours at 37 degrees C in different types of solutions: water, coffee, coffee with sugar, tea, tea with sugar, coffee with artificial creamer and sugar, cola, red wine, or sour cherry juice. Color of all specimens was measured before and after exposure with a colorimeter using CIE L * a * b * relative, and color changes (DeltaE * ) were then calculated. The data were analyzed with a 2-way analysis of variance (ANOVA), and mean values were compared by the Tukey HSD test (alpha = .05). RESULTS: The interaction of provisional restorative materials and staining agents was statistically significant ( P = .0001). For the 5 restorative materials tested, the lowest DeltaE * values were observed in the water, cola, and sour cherry juice groups. The highest color difference for all restorative materials was observed in the red wine groups. For microhybrid composite materials and light-polymerized composite provisional material, when tea and coffee groups with and without sugar were compared, both groups with sugar demonstrated a higher color difference than without sugar. When comparing the 5 different restorative materials, the reinforced microfill material group (Micronew) demonstrated significantly less color change than the other materials tested. The highest color difference in this study was observed for specimens in the light-polymerized composite provisional material group (Revotek LC). CONCLUSION: The reinforced microfill restorative material tested was found significantly more color stable than the autopolymerized bis-acryl, light-polymerized composite provisional restorative materials, and microhybrid composites tested. The largest color difference was observed in the light-polymerized composite provisional material. The presence of sugar in coffee and tea increased the color difference compared to coffee or tea without sugar for light-polymerized composite provisional material and microhybrid composites.

Acrylic Resins↗

Technique for fabricating a cement-retained single-unit implant-supported provisional restoration in the esthetic zone.

The fabrication of provisional restorations is an important stage in implant treatment. In the esthetic zone, the potential for error without the use of provisional restorations in the selection of the abutments, framework design, appropriate vertical dimension of occlusion, occlusal profile, and the esthetic interpretation may be significant. Provisional restorations are indicated in esthetic zones, for the contouring of the gingiva, to achieve an acceptable emergence profile, to have custom-guided tissue healing, and to induce appropriate soft-tissue topography. This article describes the fabrication of a provisional restoration for a single-unit implant-supported crown.

Cementation↗

Long-term effects of storage and thermal cycling on the marginal adaptation of provisional resin crowns: a pilot study.

STATEMENT OF PROBLEM: Provisional resin crowns may be used for an extended period while complex treatments are completed. The crowns function intraorally; therefore, moisture absorption and thermal cycling may affect the physical properties of acrylic resin, causing a change in marginal gap size. PURPOSE: The purpose of this pilot study was to examine the effect of long-term water absorption and thermal cycling on marginal gap size of polymethyl methacrylate copolymer and bis-acrylic composite resin crowns. MATERIAL AND METHODS: Specimens (n = 10) were fabricated from 2 acrylic resins: a polymethyl methacrylate (Alike) and a bis-acrylic composite resin (Provitec). Specimens were first fabricated on a metal master die. Custom die stems were fabricated for each specimen from a low-fusing alloy (Cerroblend) to eliminate the factor of polymerization shrinkage. Specimens were then fitted to assure a standardized, pre-experimental marginal gap range of < or = 25 microm. Specimens were stored in a humidor at 37 degrees C and 97% relative humidity for 1 year and subsequently thermal cycled (5 degrees C to 60 degrees C, 6-second dwell time, for 8000 cycles). Measurements in micrometers of the marginal gap were recorded using a microscope equipped with a digital video camera and image analysis software before and after treatment. A 2-way analysis of variance with a split design was performed for factors of materials and treatment (alpha = .05). RESULTS: For the factor of material, there was no significant difference; however, there was a significant difference between treatments, with a significantly greater increase in marginal gap size after thermal cycling (P < .002). CONCLUSION: Provisional crowns made from either a bis-acrylic resin composite or a polymethyl methacrylate copolymer demonstrated loss of marginal adaptation during a simulated long-term period of service.

Acrylic Resins↗

Immediate placement and immediate provisional abutment modeling in anterior single-tooth implant restorations using a CAD/CAM application: a clinical report.

A patient underwent immediate implant placement and immediate provisional restoration with nonocclusal loading in the right central incisor area. A provisional custom abutment and a cemented provisional restoration were fabricated. At the impression appointment, an implant level impression was made and the provisional abutment was scanned for fabrication of the definitive custom abutment. This clinical report describes how CAD/CAM technology can facilitate the definitive restoration of immediately placed and loaded implants by allowing the fabrication of the definitive abutment as an exact duplicate of the provisional abutment.

Adult↗

Provisional anterior tooth replacement using nonimpregnated fiber and fiber-reinforced composite resin materials: a clinical report.

The loss of anterior teeth is often a serious esthetic concern. While conventional fixed partial dentures and implant-supported restorations may be the treatments of choice, nonimpregnated fibers (NFs) and fiber-reinforced composite (FRC) resins offer a conservative alternative for improving esthetics. This article describes 2 clinical situations in which NF glass ribbon and FRC were successfully used to provisionally restore anterior edentulous areas in an esthetic, functional, and timely manner.

Acrylic Resins↗

Marginal accuracy of interim restorations fabricated from four interim autopolymerizing resins.

STATEMENT OF PROBLEM: One of the most important requirements for interim restorations is good marginal adaptation. Polymerization shrinkage of interim restorative materials can jeopardize the marginal integrity of interim restorations. PURPOSE: The purpose of this study was to compare the marginal accuracy of interim restorations made with 4 interim materials. MATERIAL AND METHODS: A direct technique was used to fabricate 44 interim restorations with 4 materials: Protemp 3 Garant, Trim II, Tempron, and Acropars (n=11). The interim restorations were made on a prepared molar-shaped metal die with a vinyl polysiloxane impression as a matrix. Marginal discrepancy of interim restorations was measured at the midpoint of buccal, palatal, mesial, and distal surfaces of metal die finish line with a microscope at x100 magnification. Comparisons were made with 1-way analysis of variance and the Duncan multiple range test (alpha=.05). RESULTS: The mean marginal discrepancies of Protemp 3 Garant, Trim II, Tempron, and Acropars were 0.059, 0.063, 0.068, and 0.102 mm, respectively. Acropars exhibited the most marginal discrepancies and was significantly different from the other materials tested (P<.001). However, there were no statistical differences between the other 3 materials tested. CONCLUSIONS: Interim restorations made from the Bis-GMA and conventional acrylic resins tested produced comparable marginal fit. Acropars demonstrated significant increases in marginal gap size.

Acrylic Resins↗

The comparison of provisional luting agents and abutment surface roughness on the retention of provisional implant-supported crowns.

STATEMENT OF PROBLEM: In immediate implant loading, it is important to keep provisional restorations in place during early-phase healing. Current luting agents for provisional restorations may provide inadequate retention, creating a clinical challenge. PURPOSE: This study compared the retention of provisional autopolymerizing acrylic resin implant-supported single restorations with combinations of different implant abutment surface conditions and provisional luting agents. MATERIAL AND METHODS: Thirty solid titanium implant abutments (ITI), 4 mm high, were divided into 3 groups. Ten abutments were unaltered, 10 were airborne-particle abraded with 50-microm aluminum oxide, and 10 were roughened with a medium-roughness diamond rotary cutting instrument. Thirty implant analogs (ITI) were mounted in autopolymerizing acrylic resin blocks. A solid titanium implant abutment was placed in each implant analog and torqued to 35 N.cm. After fabrication of 4 provisional acrylic resin crowns for each abutment, provisional luting agents TempBond, TempBond NE, Life, and Zone were used to secure the provisional crowns to the respective abutments. All specimens were luted with one of the provisional luting agents for a given test. After ultrasonic cleaning of the abutments, another provisional crown was luted with another luting agent. All specimens were stored in 100% humidity environment for 1 day at 37 degrees C prior to testing. Each provisional acrylic resin crown was pulled from the abutment with a 500-kg load cell in a universal testing machine at a crosshead speed of 0.5 cm/minute, and tensile strength was recorded (N). Data were analyzed using analysis of variance (ANOVA) and the Scheffe test (alpha=.05). RESULTS: Tensile strength was significantly higher for Life and TempBond NE than for TempBond and Zone, regardless of the surface conditions (P=.0001). The result of the 2-way ANOVA indicated that a significant interaction existed between the provisional luting agents and surface conditions (P=.0039). TempBond NE showed significantly higher tensile strength when combined with airborne-particle-abraded surfaces compared to other combinations (P=.011). However, no difference was found in tensile strength of Life and Zone between different combinations. The tensile strength of TempBond was lower when used with the unaltered surface compared to other combinations (P=.001). CONCLUSION: Surface modification of an implant abutment by airborne-particle abrasion or diamond rotary cutting instrument did not improve retention of a provisional acrylic crown when Life or Zone was used as the luting agent. Airborne-particle abrasion may be an effective method to increase retention of a provisional acrylic crown when TempBond NE is used.

Acrylic Resins↗

Restoration of immediately placed implants in 3 appointments: from surgical placement to definitive prostheses.

This article describes a comprehensive approach that enables the clinician to place dental implants, and fabricate a provisional prosthesis and a definitive metal-acrylic resin or metal-ceramic fixed complete denture in 3 appointments. This technique allows the practitioner to immediately load the implants with a provisional fixed complete denture at the time of implant placement, to record the relative positions of the implants and soft tissues, the occlusal vertical dimension, maxillomandibular relationship, and tooth position at the second appointment by using the information provided by the provisional fixed denture, and to insert the definitive prosthesis at the third appointment. This technique reduces chair time for both the patient and the clinician, and could ultimately reduce the cost of implant treatment and potentially increase treatment acceptance.

Acrylic Resins↗

Comparison of temperature increase in the pulp chamber during the polymerization of materials used for the direct fabrication of provisional restorations.

STATEMENT OF PROBLEM: Polymerization of resin materials used for the fabrication of provisional restorations is associated with an exothermic reaction. This temperature rise may present a serious biological problem, since it can cause iatrogenic thermal trauma to the pulp. PURPOSE: This in vitro study compared the temperature increase in the pulp chamber of a molar placed in contact with different resins used for the direct fabrication of provisional restorations. MATERIAL AND METHODS: Polymethyl methacrylate (Jet), polyethyl methacrylate (Snap), polyvinylethyl methacrylate (Trim), Bis-acrylic composite (Protemp II), and a VLP urethane dimethacrylate (Revotec LC) were compared with respect to their exothermic reaction properties during polymerization. A mandibular molar prepared for a complete coverage restoration was placed in an acrylic resin block. A thermal probe connected to a digital thermometer was placed into the pulp chamber. Specimens were submerged in a water bath to simulate intraoral conditions. The provisional resin materials tested were measured and mixed according to manufacturer's instructions. The resin mixture was placed into a vacuum-formed acetate template and was then positioned on the prepared molar tooth. The temperature was recorded during polymerization at 30-second intervals until it was evident that the peak temperature had been reached. Temperature increase was measured ( degrees C) for both the initial crown fabrication and the reline procedures. Data were analyzed with descriptive statistics, 1-way analysis of variance, and Tukey Honestly Significant Difference tests (alpha=.05). RESULTS: One-way ANOVA revealed significant differences (F=57.010, P<.0001) in temperature rise for different provisional resin materials. Mean temperature increase for the provisional crown fabrication ranged from 37.76 degrees C for the polyvinylethyl methacrylate to 39.40 degrees C for the polymethyl methacrylate. Mean temperature rise for the reline procedures ranged from 36.80 degrees C for the polyvinylethyl methacrylate to 37.69 degrees C for the polymethyl methacrylate. All of the tested materials produced an exothermic chemical reaction. CONCLUSIONS: Polymethyl methacrylate produced the higher exothermic reaction in both initial crown fabrication and reline procedures. Polyethyl methacrylate, polyvinylethyl methacrylate, and Bis-acrylic resins tested were not significantly different from each other.

Acrylic Resins↗

Monotonic flexure and fatigue strength of composites for provisional and definitive restorations.

STATEMENT OF PROBLEM: Ordinarily, the mechanical strength of composites is characterized by their flexural strength. Information as to the material's fatigue strength is seldom provided. PURPOSE: The purpose of this study was to compare the flexural strength and the resistance to fatigue loading of composites and an acrylic resin for provisional and definitive restorations. MATERIAL AND METHODS: Artglass, Colombus, and Targis (composites) and Jet, Protemp II, Protemp Garant, and Provipont DC (provisional restorations) were subjected to mechanical tests. Fatigue tests (MPa) (n = 30 specimens/group) were conducted with the rotating-bending cantilever design. Monotonic flexural strength (MPa) (n = 10) was determined in 3-point bending tests. Fatigue resistance was analyzed via the staircase procedure, and flexural strength was examined by use of the 2-parameter Weibull distribution (confidence intervals at 95%). RESULTS: The mean fatigue resistances (S(50)) in MPa +/- SD were: Targis, 62.1 +/- 7.0; Artglass, 58.5 +/- 3.7; Colombus, 54.6 +/- 6.2; Provipont DC, 29.5 +/- 3.2; Protemp II, 23.1 +/- 5.3; Jet, 22.8 +/- 8.3; Protemp Garant, 19.6 +/- 4.6. The flexure strengths (Weibull's S(0)) in MPa and their shape parameters (m) were: Colombus, 145.2 (13.1); Targis, 110.3 (7.8); Artglass, 5.9 (5.4); Jet, 150.9 (17.3); Provipont DC, 97.3 (23.8); Protemp II, 57.9 (6.4); Protemp Garant, 54.2 (12.8). The S(50) of Targis was significantly higher than that of Colombus but not different from Artglass. In flexion, the S(0) of Colombus was significantly higher than that of Artglass and Targis. The S(50) ranged between 40% and 60% of the S(0) for the composites and between 15% and 30% for the provisional restorative materials. CONCLUSIONS: Correlations between monotonic flexure strength and resistance to fatigue loading were weak. Because fatigue tests are considered more pertinent than monotonic tests as to their predictive value, it is concluded that flexure strength data alone may not provide relevant information for long-term clinical performance. The material's resistance to fatigue loading should also be determined.

Acrylic Resins↗

Effects of relining on long-term marginal stability of provisional crowns.

Provisional resins crowns are commonly placed to protect prepared teeth, but the marginal adaptation of interim crowns has always been a problem. These experiments examined the effects of thermocycling and occlusal loading on relined and unrelined polymethyl methacrylate resin transitional crowns. Three groups of interim crowns were made on a cast metal die tooth preparation; unrelined, relined correction, and paint-on correction. After thermocycling and occlusal loading of the specimens, the change in mean marginal gap was significantly greater for the unrelined group. Axial changes were greatest for relined group and least for the unrelined group. These results suggested that relining of polymethyl methacrylate interim crowns can be useful to prevent increases in marginal gap width during extended intraoral periods.

Analysis of Variance↗

Effect of provisional luting agents on polyvinyl siloxane impression material.

Eugenol-containing cements have been traditionally selected for seating provisional restorations, but incomplete polymerization of polyvinyl siloxane impression materials has been attributed to these cements. This study clinically evaluated the inhibitory effect on polymerization of a specific polyvinyl siloxane impression material with five luting agents used for provisional restorations. Three of these luting agents contained eugenol, whereas two interim cements did not contain eugenol. A total of 60 human posterior teeth were prepared for complete crowns, fitted for provisional crowns, and cemented with interim luting agents. After 2.5 weeks the provisional crowns were removed, the cement on tooth preparations was removed with an explorer, and impressions were made. The results revealed that none of the luting agents in this investigation had an inhibitory effect on polymerization of polyvinyl siloxane impression materials.

Calcium Hydroxide↗