PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “OBSTETRICAL FORCEPS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

[Connexions between instrumental delivery and cerebral damage in the infant (author's transl)].

An interdepartmental investigation was carried out on the incidence of brain injury, especially so-called minimal brain injury, after instrumental delivery of infants by means of forceps or vacuum extractor. There is no statistically-significant difference in the incidence of brain injury in infants delivered by means of forceps as compared with the vacuum extractor; there is, however, a significant increase in incidence of brain injury in infants following instrument-aided delivery as opposed to spontaneous delivery. A thorough explanation of the methods is given and the results are discussed.

Attention Deficit Disorder with Hyperactivity↗

Forceps and vacuum extraction.

The proper use of forceps or vacuum extractor, or both, remains a safe and effective modality in achieving the universal goal of a healthy mother and baby. Their use requires continued experience, sharing of information, and possibly attention to subtleties of design. This review looks at the current situation with special emphasis on side effects and selection issues as found in the recent literature.

Birth Injuries↗

Soft cup vacuum extraction: a comparison of outlet delivery.

One hundred eighteen nulliparous patients delivered under conduction anesthesia who met the standard criteria for low forceps delivery were randomly assigned to one of three groups to be delivered by low Tucker-McLane forceps, Silastic vacuum extraction system, or Mityvac vacuum extractor. Significant maternal soft tissue trauma was identified in 48.9% of the forceps group, 36.1% of the Silastic group, and 21.6% of the Mityvac group. Superficial fetal scalp changes were found in 71% of the forceps group, 44% of the Silastic group, and 46% of the Mityvac group. Of these, cephalhematomatas were noted in 2.2% of the forceps group, 13.9% of the Silastic group, and 16.2% of the Mityvac group. All three instruments were considered effective outlet delivery instruments.

Adolescent↗

Neonatal acid-base balance in spontaneous and instrumental vaginal deliveries.

The acid-base balances of 63 neonates delivered either spontaneously or by the vacuum extractor or low forceps were compared. The outcome was similar in neonates delivered by vacuum extractor or forceps. However, significant differences were noted in the pH and base deficit of infants born by instrumental versus spontaneous delivery. These differences were no longer present when groups with similar duration in the second stage of labor were compared. We conclude that the use of instruments for outlet vaginal delivery carries no additional risk for the fetus.

Acid-Base Equilibrium↗

Clinical experience with the Silc Cup Vacuum Extractor.

The relative merits of vacuum extraction have been extensively studied and its advantages analysed. These include its ease of application, encouragement of "autorotation" of the malpositioned foetal head and its safety for both foetus and especially the mother. One hundred and eighty-six vacuum extraction assisted deliveries were performed at the Department of Gynaecological Oncology & Urology, Kandang Kerbau Hospital, from 1988 to 1990 using the 50 mm Silicone Silc Cup Vacuum Extractor (Menox AB). Anaesthetic requirements were minimal with 97% of cases accomplished with local perineal anaesthesia. Maternal complications were very few and only 1.6% of cases had third degree lacerations. There was no maternal or foetal mortality. The most frequent foetal morbidity was neonatal jaundice (28%) with only 7% requiring phototherapy. Cephalohaematoma was found in 8% and 2% had minor scalp abrasions. There were 3 infants with subaponeurotic haematoma who subsequently recovered uneventfully. Vacuum deliveries that were attempted but completed by forceps deliveries ("failed" vacuum extraction) accounted for 10% of total cases. The Silc cup vacuum extractor although not a replacement for all forceps manoeuvres offers a safe and efficient method of assisted delivery under the appropriate clinical circumstances.

Adult↗

Guidelines for operative vaginal birth. Number 148, May 2004.

OBJECTIVE: To provide guidelines for operative vaginal birth in the management of the second state of labour. OPTIONS: Nonoperative techniques, episiotomy, and Caesarean section are compared to operative vaginal birth. OUTCOME: Reduced fetal and maternal morbidity and mortality. EVIDENCE: MEDLINE and Cochrane databases were searched using the key words "vacuum" and "birth" as well as "forceps" and "birth" for literature published in English from january 1970 to June 2004. The level of evidence and quality of recommendations made are described using the Evaluation of Evidence from the Canadian Task Force on the Periodic Health Examination. RECOMMENDATIONS: (1) Nonoperative interventions such as one-to-one support, partogram use, oxytocin use, and delayed pushing in women using epidurals will decrease need for operative birth (I-A). (2) Manual rotation may be used alone or in conjunction with instrumental birth with little or no increased risk to the pregnant women or the fetus (III-B). (3) Routine episiotomy is not necessary for an assisted vaginal birth (II-1E). (4) When operative intervention in the second stage of labour is required, the options, risks, and benefits of vacuum, forceps, and Caesarean section much be considered. The choice of intervention needs to be individualized, as one is not clearly safer or more effective than the other (II-B). (5) Failure of the chosen method, vacuum and/or forceps, to achieve delivery of the fetus in a reasonable time should be considered an indication for abandonment of the method (III-C). (6) Adequate clinical experience and appropriate training of the operator are essential to the safe performance of operative deliveries. Hospital credentialing boards should grant privileges for performing these techniques only to an appropriately trained individual who demonstrates adequate skills (III-C). VALIDATION: The Clinical Practice Obstetrics Committee and Executive and Council of the Society of Obstetricians and Gynaecologists of Canada approved these guidelines.

Cesarean Section↗

Vasopressin concentration in cord blood: correlation with method of delivery and cord pH.

Cord plasma vasopressin concentration, determined by radioimmunoassay, was higher in arterial than in venous blood in 122 (84%) infants; the highest vasopressin values were recorded in 21 acidotic infants (mean cord pH, 7.13) delivered per vaginam and the lowest values in 50 infants delivered by cesarean section. Cord vasopressin levels were not elevated in infants delivered by cesarean section because of obstructed labor. There was a lack of correlation between vasopressin levels and the length of labor or cervical dilatation; a significant correlation was found between cord arterial vasopressin values and pH. Low vasopressin values were recorded in a group of 22 healthy infants (mean cord pH, 7.29) delivered by low forceps operation.

Abruptio Placentae↗

An audit of forceps delivery in Trinidad.

An audit of 247 consecutive forceps deliveries during a 6-year period was undertaken in order to establish trends in recourse to this instrument, maternal complications and fetal outcome. The chief indications were prolonged second stage of labour and poor maternal effort. Our overall forceps rate of 0.81% betrays a marked divergence from the practice in metropolitan countries. Although birth injuries were a major drawback, assistance with forceps still appears to be a safer alternative than caesarean section when a problem exists which impedes spontaneous delivery in the second stage. In choosing between obstetric options, we voluntarily take one course which we dislike because the alternative is more objectionable still; the unpleasantness of the choice does not destroy its reality.

Delivery, Obstetric↗