PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Reconstruction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

Tilted plane Feldkamp type reconstruction algorithm for spiral cone beam CT.

An approximate image reconstruction method for spiral cone beam computed tomography (CT), called tilted plane Feldkamp type reconstruction algorithm (TPFR), is presented in this paper, which extends Feldkamp cone beam reconstruction algorithm to deal with its inaccuracy and artifact problems caused by large cone angle. This is done by tilting the reconstructing planes to minimize the cone angle and optimally fit the spiral segment of the source. The tilted plane image reconstruction requires reforming the three-dimensional projection data set for the tilted plane and application of Feldkamp algorithm to the reformed data set. Analytical and computational results can show that the image reconstruction performance of the proposed TPFR algorithm is superior to that of the Feldkamp reconstruction algorithm in the image quality, volume coverage speed, maximum achievable pitch value, and slice sensitivity profiles. Moreover, it provides more accurate image reconstruction than the existing two-dimensional reconstruction algorithms.

Algorithms↗

A statistically tailored neural network approach to tomographic image reconstruction.

In previous work it has been shown that a standard backpropagation neural network can be trained to reconstruct sections of single photon emission computed tomography (SPECT) images based on the planar image projections as inputs. In this study, it is demonstrated that an artificial neural network (ANN) trained on a series of simulated SPECT images or trained on a set of rudimentary geometric images can learn the planar data-to-tomographic image relationship for 64 x 64 tomograms. As a result, a properly trained ANN can produce accurate, novel image reconstructions but without the high computational cost inherent in some traditional reconstruction techniques. We also present a method of deriving activation functions for a backpropagation ANN that make it readily trainable for cardiac SPECT image reconstruction. The activation functions are derived from the estimated probability density functions (p.d.f.s) of the ANN training set data. The performance of the statistically tailored ANNs are compared with the performance of standard sigmoidal back-propagation ANNs, both in terms of their trainability and generalization ability. The results presented demonstrate that statistically tailored ANNs are significantly better than standard sigmoidal ANNs at reconstructing novel tomographic images based on a simulated SPECT image training set or a rudimentary geometric image training set. Neural network based image reconstruction has two potential advantages over conventional reconstruction methods. The first advantage is that ANNs can rapidly reconstruction tomograms. Secondly, the quality of the reconstructions produced are directly correlated to the quality of the images used to train the ANN.

Heart↗

Three-dimensional reconstruction of human coronary and peripheral arteries from images recorded during two-dimensional intravascular ultrasound examination.

BACKGROUND: Intravascular ultrasound provides high-resolution images of vascular lumen, plaque, and subjacent structures in the vessel wall; current instrumentation, however, limits the operator to viewing a single, tomographic, two-dimensional image at any one time. Comparative analysis of serial two-dimensional images requires repeated review of the video playback recorded during the two-dimensional examination, followed by a "mind's eye" type of imagined reconstruction. METHODS AND RESULTS: Computer-based, automated three-dimensional reconstruction was used to generate a tangible format with which to assess and compare a "stacked" series of two-dimensional images. Three-dimensional representations were prepared from sequential images obtained during intravascular ultrasound examination in 52 patients, 50 of whom were studied before and/or after percutaneous revascularization. Conventional two-dimensional ultrasound images were acquired by means of a systematic, timed pullback of the ultrasound catheter through the respective vascular segments. Images were then assembled in automated fashion to create a three-dimensional depiction of the vessel lumen and wall. Computer-enhanced three-dimensional reconstructions were generated in both sagittal and cylindrical formats. The sagittal format resulted in a longitudinal profile similar to that obtained during angiographic examination; in contrast to angiography, however, the sagittal reconstruction offered 360 degrees of limitless orthogonal views of the plaque and arterial wall as well as the vascular lumen. The cylindrical format yielded a composite view of a given vascular segment, and a hemisected version of the cylindrical reconstruction enabled en face inspection of the reconstructed luminal surface. Sagittal reconstructions facilitated analysis of dissections and plaque fractures resulting from percutaneous revascularization, and the hemisected cylindrical reconstructions enhanced analysis of endovascular prostheses. CONCLUSIONS: This preliminary experience demonstrates that computer-based three-dimensional reconstruction may further augment the use of intravascular ultrasound in assessing vascular pathology and guiding interventional therapy.

Aged↗

Biomechanical analysis of a double-bundle posterior cruciate ligament reconstruction.

The objective of this study was to experimentally evaluate a single-bundle versus a double-bundle posterior cruciate ligament reconstruction by comparing the resulting knee biomechanics with those of the intact knee. Ten human cadaveric knees were tested using a robotic/universal force-moment sensor testing system. The knees were subjected to a 134-N posterior tibial load at five flexion angles. Three knee conditions were tested: 1) intact knee, 2) single-bundle reconstruction, and 3) double-bundle reconstruction. Posterior tibial translation of the intact knee ranged from 4.9 +/- 2.7 mm at 90 degrees to 7.2 +/- 1.5 mm at full extension. After the single-bundle reconstruction, posterior tibial translation increased to 7.3 +/- 3.9 mm and 9.2 +/- 2.8 mm at 90 degrees and full extension, respectively, while the corresponding in situ forces in the graft were up to 44 +/- 19 N lower than those in the intact ligament. Conversely, with double-bundle reconstruction, the posterior tibial translation did not differ significantly from the intact knee at any flexion angle tested. This reconstruction also restored in situ forces more closely than did the single-bundle reconstruction. These data suggest that a double-bundle posterior cruciate ligament reconstruction can more closely restore the biomechanics of the intact knee than can the single-bundle reconstruction throughout the range of knee flexion.

Adult↗

Comparison of three techniques of anterior cruciate ligament reconstruction with bone-patellar tendon-bone graft. Differences in anterior tibial translation and tunnel enlargement with each technique.

BACKGROUND: Anatomic fixation of the graft in anterior cruciate ligament reconstruction has improved stability of the reconstructed knee joint in experimental studies. HYPOTHESIS: Anatomic fixation of the bone-patellar tendon-bone autograft will reduce tunnel enlargement and improve clinical results. STUDY DESIGN: Prospective cohort study. METHODS: Sixty patients were randomly divided into three groups: a nonanatomic fixation group (traditional single-incision reconstruction), an anatomic fixation group (reconstruction in which a bone plug was grafted into the tibial tunnel), and an anatomic fixation group with all-inside reconstruction. Stability of the knee joint was examined with a KT-1000 arthrometer at 2, 4, 6, 12, and 24 months after surgery. At 12 months, anteroposterior and lateral radiographs were made to assess tunnel enlargement. RESULTS: Although the magnitude of tibial displacement gradually increased after reconstruction in all three groups, the anatomic fixation group had significantly better stability than the groups undergoing nonanatomic fixation or all-inside anatomic fixation at 4 and 6 months after anterior cruciate ligament reconstruction. However, there was no significant difference between the three groups at 24 months. Regarding the tibial tunnel, residual rates and enlargement of tunnels were different between the reconstruction techniques. The nonanatomic reconstruction group had significantly greater tunnel enlargement. CONCLUSION: Anatomic fixation of the graft decreased the tunnel enlargement but had no effect on knee stability at 2-year follow-up.

Adolescent↗

Abnormal rotational knee motion during running after anterior cruciate ligament reconstruction.

BACKGROUND: The effectiveness of anterior cruciate ligament reconstruction for restoring normal knee kinematics is largely unknown, particularly during sports movements generating large, rapidly applied forces. HYPOTHESIS: Under dynamic in vivo loading, significant differences in 3-dimensional kinematics exist between anterior cruciate ligament-reconstructed knees and the contralateral, uninjured knees. STUDY DESIGN: Prospective, in vivo laboratory study. METHODS: Kinematics of anterior cruciate ligament-reconstructed and contralateral (uninjured) knees were evaluated for 6 subjects during downhill running 4 to 12 months after anterior cruciate ligament reconstruction, using a 250 frame/s stereoradiographic system. Anatomical reference axes were determined from computed tomography scans. Kinematic differences between the uninjured and reconstructed limbs were evaluated with a repeated-measures analysis of variance. RESULTS: Anterior tibial translation was similar for the reconstructed and uninjured limbs. However, reconstructed knees were more externally rotated on average by 3.8 +/- 2.3 degrees across all subjects and time points (P =.0011). Reconstructed knees were also more adducted, by an average of 2.8 +/- 1.6 degrees (P =.0091). Although differences were small, they were consistent in all subjects. CONCLUSIONS: Anterior cruciate ligament reconstruction failed to restore normal rotational knee kinematics during dynamic loading. CLINICAL RELEVANCE: Although further study is required, these abnormal motions may contribute to long-term joint degeneration associated with anterior cruciate ligament injury/reconstruction.

Adolescent↗

An analysis of an anatomical posterolateral knee reconstruction: an in vitro biomechanical study and development of a surgical technique.

BACKGROUND: To date, no surgical technique to treat posterolateral knee instability anatomically reconstructs the 3 major static stabilizing structures of the posterolateral knee: the fibular collateral ligament, the popliteus tendon, and the popliteofibular ligament. HYPOTHESIS: Static varus and external rotatory stability would be restored to the reconstructed knee with a posterolateral knee injury. METHODS: The anatomical locations of the original fibular collateral ligament, popliteus tendon, and popliteofibular ligament were reconstructed using a 2-graft technique. Ten cadaveric specimens were tested in 3 states: intact knee, knee with the 3 structures cut to simulate a grade III injury, and the reconstructed knee. RESULTS: For the varus loading tests, joint stability was significantly improved by the posterolateral reconstruction compared to the cut state at 0 degrees, 30 degrees, 60 degrees, and 90 degrees of flexion. There were no significant differences between the intact and reconstructed knees at 0 degrees, 60 degrees, and 90 degrees for varus translation. For the external rotation torque tests, external rotation was significantly higher for the cut state than for the intact or reconstructed posterolateral knee. There was no significant difference in external rotation between the intact and reconstructed posterolateral knees at any flexion angle. CONCLUSIONS: This 2-graft technique to reconstruct the primary static stabilizers of the posterolateral knee restored static stability, as measured by joint translation in response to varus loading and external rotation torque, to knees with grade III posterolateral injuries.

Aged↗

Revision arthroscopically assisted anterior cruciate ligament reconstruction with previously unharvested ipsilateral autografts.

BACKGROUND: Revision anterior cruciate ligament reconstruction requires flexibility and variability in treatment options. This study analyzed the functional outcomes and graft stability of 48 consecutive revision anterior cruciate ligament reconstructions using previously unharvested ipsilateral autografts. HYPOTHESIS: Using previously unharvested ipsilateral autografts will achieve similar outcomes to other graft choices in revising previously failed anterior cruciate ligament reconstructions. STUDY DESIGN: Prospective nonrandomized clinical trial. METHODS: Forty-eight patients (48 operations) were observed for 2 to 13 years (mean, 90 months). All agreed to have revision reconstruction with ipsilateral autografts. The details of the technique varied according to the original graft choice and the abnormality encountered. Concomitant procedures were necessary in 40 (84%) of 48 knees. Twenty-three patients (48%) had revision reconstruction with previously unharvested ipsilateral autogenous hamstring tendons. Ten (21%) were 2-stranded grafts, and 13 (27%) were 4-stranded (quadrupled) autografts. Twenty-five patients (52%) had revision reconstruction with previously unharvested ipsilateral patellar tendon autografts, 6 (12%) using the 2-incision rear-entry method and 19 (40%) using the single-incision technique. RESULTS: Results were evaluated with Lysholm and Gillquist scores and International Knee Documentation Committee ratings, including KT-2000 arthrometer examinations. Seventy-three percent of the patients had International Knee Documentation Committee normal (A) or nearly normal (B) knees (42% of the patients had A knees and 42% had B knees). Twelve percent of patients had C knees, and 4% had a D rating. Sixty-seven percent of the knees had a KT-2000 arthrometer side-to-side difference of 3 mm or less, and an additional 21% of the knees had a side-to-side difference of 3 to 5 mm; therefore, 94% of the grafts were functional or partially functional. Six percent of grafts had more than 5 mm of laxity and were considered failures. CONCLUSIONS: Previously unharvested ipsilateral autografts proved reliable in improving function and stability in revision anterior cruciate ligament reconstruction. However, outcomes were less favorable with revision reconstructions than with primary reconstructions.

Adolescent↗

Anatomical double-bundle anterior cruciate ligament reconstruction after valgus high tibial osteotomy: a biomechanical study.

BACKGROUND: Although anatomical double-bundle anterior cruciate ligament reconstruction can successfully restore normal knee biomechanics for knees with typical varus-valgus alignment, the efficacy of the same reconstruction method for knees after a valgus high tibial osteotomy is unclear. HYPOTHESIS: Anatomical double-bundle anterior cruciate ligament reconstruction for valgus knees after a high tibial osteotomy cannot restore normal knee kinematics and can result in abnormally high in situ forces in the ligament graft. STUDY DESIGN: Controlled laboratory study. METHODS: Ten cadaveric knees were subjected to valgus high tibial osteotomy followed by an anatomical double-bundle anterior cruciate ligament reconstruction. The valgus knees were tested using a robotic/universal force-moment sensor system before and after the ligament reconstruction. The knee kinematics in response to anterior tibial load and combined rotatory loads, as well as the corresponding in situ forces of the anterior cruciate ligament bundles and grafts, were compared between the ligament-intact and ligament-reconstructed valgus knees. RESULTS: After reconstruction, the anterior tibial translation and internal tibial rotation for the valgus knee decreased approximately 2 mm and 2 degrees , respectively, at low flexion angles compared with those of the anterior cruciate ligament-intact knee (P < .05). The in situ forces in the posterolateral graft became 56% to 200% higher than those in the posterolateral bundle of the intact anterior cruciate ligament (P < .05). CONCLUSION: Performing an anatomical double-bundle anterior cruciate ligament reconstruction on knees after valgus high tibial osteotomy may overconstrain the knee and result in high forces in the posterolateral graft, which could predispose it to failure. CLINICAL RELEVANCE: Modifications of anterior cruciate ligament reconstruction procedures to reduce posterolateral graft force may be needed for valgus knees after a high tibial osteotomy.

Adult↗

Biomechanical evaluation of two techniques for double-bundle anterior cruciate ligament reconstruction: one tibial tunnel versus two tibial tunnels.

BACKGROUND: This research was undertaken to determine whether there is a need for a second tibial tunnel in anatomic anterior cruciate ligament reconstruction. HYPOTHESIS: Anatomic two-bundle reconstruction with two tibial tunnels restores knee anterior tibial translation in response to 134 N and to 5-N.m internal tibial torque combined with 10-N.m valgus torque more closely to normal than does double-bundle reconstruction with one tibial tunnel. STUDY DESIGN: Controlled laboratory study. METHODS: Ten cadaveric knees were subjected to a 134-N anterior tibial load at 0 degrees, 30 degrees, 60 degrees, and 90 degrees and to 5-N.m internal tibial torque and 10-N.m valgus torque at 15 degrees and 30 degrees. Resulting knee kinematics and in situ force in the anterior cruciate ligament or replacement graft were determined by using a robotic/universal force-moment sensor testing system for (1) intact, (2) anterior cruciate ligament-deficient, (3) double-bundle/one tibial tunnel, and (4) double-bundle/two tibial tunnels. RESULTS: Anterior tibial translation for the reconstruction with two tibial tunnels was significantly closer to that of the intact knee than was the reconstruction with one tibial tunnel at 0 degrees and 30 degrees of flexion (0 degrees = 3.82 vs 6.0 mm, P < .05; 30 degrees = 7.99 vs 11 mm, P < .05). The in situ force normalized to the intact anterior cruciate ligament for the reconstruction with two tibial tunnels was significantly higher than the in situ force of the reconstruction with one tibial tunnel (30 degrees = 89 vs 82 N, P < .05). With a combined rotatory load, the anterior tibial translation of specimens with a tibial two-tunnel technique was significantly lower than that of specimens with one tunnel (0 degrees = 5.7 vs 8.4 mm, P < .05; 30 degrees = 7.5 vs 9.5 mm, P < .05). CONCLUSIONS: Anatomic reconstruction with two tibial tunnels may produce a better biomechanical outcome, especially close to extension. CLINICAL RELEVANCE: At the time of initial fixation, there appears to be a small biomechanical advantage to the second tibial tunnel in the setting of two-bundle anterior cruciate ligament reconstruction.

Aged↗

Graft tension in anterior cruciate ligament reconstruction. An in vivo study in dogs.

The purpose of this study was to examine the effect of initial tensioning on the outcome of reconstruction of the ACL. The ACLs of 15 adult mongrel dogs were excised and reconstructed. In the first five dogs, the ACLs of both knees were reconstructed using the medial one-third of the patellar tendon. The graft was fixed under a tension of 1 N (0.22 pounds) in one knee and 39 N (8.8 pounds) in the opposite knee. In the remainder of the dogs, the reconstructions were augmented with Dacron prostheses. Tensioning of both graft components in the augmented reconstructions was either with 1 N in one knee and 39 N in the contralateral knee or disproportionate tensions of 1 N and 39 N applied to the autogenous material and to the prosthesis. Sacrifice was 3 months postsurgery and results were examined with microangiography/history and mechanical testing. In the reconstructions with the patellar tendon alone, the biologic study showed poor vascularity and focal myxoid degeneration within the graft pretensioned with a load of 39 N. In the augmented reconstructions, the knees in which both graft materials were fixed with 1 N tension showed the strongest and stiffest reconstruction at 3 months. The study suggests that minimal tension should be applied to the graft materials during surgical reconstruction of the ACL.

Angiography↗

Reconstruction of the lateral ligaments: do the anatomical procedures restore physiologic ankle kinematics?

BACKGROUND: If conservative therapy fails, the standard treatment for chronic ankle instability is surgical reconstruction of the lateral ligaments. For the last seventy years, the tenodesis principles have been used for reconstruction. Recently however, surgical reconstructions--respecting the intact joint anatomy--have been developed, thus called "anatomical reconstruction principles". METHODS: This study focused on the investigation of the range of motion of the ankle and the subtalar joint following anatomical reconstruction surgery. Three different types of anatomical reconstruction procedures were compared: Direct ligament repair, tendon graft and carbon-fiber implant. RESULTS: All procedures restored the original range of motion of the subtalar joint, except for the plantarflexed/dorsiflexed positions. As for the talocrural joint, the tendon graft and the carbon fiber implant left a small laxity for movements of inversion/eversion and internal/external rotation. The direct repair procedure achieved a more accurate result and restored the physiologic kinematics almost completely. During each procedure the insertion points and the direction of the original ligaments were maintained. However, the different results for the procedure of direct ligament repair compared to the other two anatomical reconstruction procedures showed that this condition alone is not sufficient to perfectly restore the kinematics of the talocrural and subtalar joints. It is important to note that none of the procedures caused a restriction of the range of motion. CONCLUSIONS: The maintenance of the range of hindfoot motion decreases the risk of osteoarthritis as well as chronic pain or problems for the patient to walk on uneven surface. Therefore, we believe that standard therapy for chronic instability of the ankle should include direct surgical reconstruction of the ligaments. If this direct procedure cannot be performed because of poor quality of the ligaments an alternative anatomical reconstruction procedure should be considered.

Aged↗

Total hip arthroplasty: the relationship between posterolateral reconstruction, abductor muscle strength, and femoral offset.

PURPOSE: To evaluate the relationship between posterolateral reconstruction, abductor muscle strength, and femoral offset following total hip arthroplasty. METHODS: Of 28 patients (56 limbs) we assessed, 12 underwent posterolateral reconstruction (reconstruction group) and 16 did not (non-reconstruction group). Isometric abductor muscle strength was measured with a handheld dynamometer. Each patient's muscle strength was converted into a force to body weight ratio, and this ratio was used in the comparisons. RESULTS: The reconstruction group showed a higher value in abductor muscle strength than the non-reconstruction group (p<0.05). Significant correlation between abductor muscle strength and femoral offset was found in the reconstruction group (p=0.016; r=0.674). CONCLUSION: Posterolateral reconstruction and appropriate reconstruction of femoral offset following total hip arthroplasty are important to improve the abductor muscle strength.

Aged↗

Noise correlation in PET, CT, SPECT and PET/CT data evaluated using autocorrelation function: a phantom study on data, reconstructed using FBP and OSEM.

BACKGROUND: Positron Emission Tomography (PET), Computed Tomography (CT), PET/CT and Single Photon Emission Tomography (SPECT) are non-invasive imaging tools used for creating two dimensional (2D) cross section images of three dimensional (3D) objects. PET and SPECT have the potential of providing functional or biochemical information by measuring distribution and kinetics of radiolabelled molecules, whereas CT visualizes X-ray density in tissues in the body. PET/CT provides fused images representing both functional and anatomical information with better precision in localization than PET alone. Images generated by these types of techniques are generally noisy, thereby impairing the imaging potential and affecting the precision in quantitative values derived from the images. It is crucial to explore and understand the properties of noise in these imaging techniques. Here we used autocorrelation function (ACF) specifically to describe noise correlation and its non-isotropic behaviour in experimentally generated images of PET, CT, PET/CT and SPECT. METHODS: Experiments were performed using phantoms with different shapes. In PET and PET/CT studies, data were acquired in 2D acquisition mode and reconstructed by both analytical filter back projection (FBP) and iterative, ordered subsets expectation maximisation (OSEM) methods. In the PET/CT studies, different magnitudes of X-ray dose in the transmission were employed by using different mA settings for the X-ray tube. In the CT studies, data were acquired using different slice thickness with and without applied dose reduction function and the images were reconstructed by FBP. SPECT studies were performed in 2D, reconstructed using FBP and OSEM, using post 3D filtering. ACF images were generated from the primary images, and profiles across the ACF images were used to describe the noise correlation in different directions. The variance of noise across the images was visualised as images and with profiles across these images. RESULTS: The most important finding was that the pattern of noise correlation is rotation symmetric or isotropic, independent of object shape in PET and PET/CT images reconstructed using the iterative method. This is, however, not the case in FBP images when the shape of phantom is not circular. Also CT images reconstructed using FBP show the same non-isotropic pattern independent of slice thickness and utilization of care dose function. SPECT images show an isotropic correlation of the noise independent of object shape or applied reconstruction algorithm. Noise in PET/CT images was identical independent of the applied X-ray dose in the transmission part (CT), indicating that the noise from transmission with the applied doses does not propagate into the PET images showing that the noise from the emission part is dominant. The results indicate that in human studies it is possible to utilize a low dose in transmission part while maintaining the noise behaviour and the quality of the images. CONCLUSION: The combined effect of noise correlation for asymmetric objects and a varying noise variance across the image field significantly complicates the interpretation of the images when statistical methods are used, such as with statistical estimates of precision in average values, use of statistical parametric mapping methods and principal component analysis. Hence it is recommended that iterative reconstruction methods are used for such applications. However, it is possible to calculate the noise analytically in images reconstructed by FBP, while it is not possible to do the same calculation in images reconstructed by iterative methods. Therefore for performing statistical methods of analysis which depend on knowing the noise, FBP would be preferred.

Journal Article↗

Immediate reconstruction after neoadjuvant chemotherapy: effect on adjuvant treatment starting and survival.

BACKGROUND: For patients treated with initial surgery, the safety of immediate breast reconstruction after mastectomy has been demonstrated. Some concerns exist after neoadjuvant chemotherapy because this sequence is proposed for patients with large tumors and for whom adjuvant therapies are considered cornerstones of treatment. In this study, we sought to determine whether reconstruction after neoadjuvant chemotherapy and mastectomy for large operable breast cancer affects the interval between surgery and adjuvant treatment and affects survival. METHODS: A single-institution retrospective analysis was performed by using the database of the Institut Gustave-Roussy. RESULTS: Forty-eight patients who had undergone mastectomy and immediate reconstruction (implant, 60%) followed by adjuvant chemotherapy were identified. They were compared with 181 patients who underwent mastectomy without reconstruction and with 32 patients who underwent mastectomy followed by delayed reconstruction (implant, 19%). No difference was found concerning the interval between surgery and adjuvant chemotherapy: 26 vs. 23 days for patients with immediate breast reconstruction and for patients treated with modified radical mastectomy followed or not by delayed reconstruction, respectively (P = .11). No difference was found concerning the onset of radiotherapy: 87 vs. 81 days (P = .22). Survival was not different in patients treated with immediate reconstruction compared with those with mastectomy alone. CONCLUSIONS: Immediate breast reconstruction does not delay the starting of adjuvant therapy and has no significant effect on local relapse-free or distant disease-free survival. Additional data are needed concerning the use of flap for this indication.

Adult↗

The influence of filtered back-projection and iterative reconstruction on partial volume correction in PET.

AIM: We assess the influence of the reconstruction algorithms [OS-EM for the iterative one vs. a filtered back-projection in Fourier space (DiFT)] on partial volume correction in PET employing a fully 3D 3-compartment MR based PV-correction algorithm. The gray matter voxels in the PET image -- after removal of the white matter and cerebrospinal fluid contribution -- are corrected voxel-by-voxel using the image resolution. MATERIAL, METHODS: Phantom measurements and one healthy human brain FDG study were carried out. For the OSEM reconstruction, a combination of iteration steps and subset numbers (It/Sub) was used, whereby in case of no-convergence the image resolution had to be fitted. The RESULTS from the DiFT reconstruction were equivalent to those obtained from the OSEM reconstruction with 10/32 combination for objects with widespread activity concentration. For the sphere phantom, the mean recovery based on the actual values achieved 99.2% +/- 1.8 for all spheres and all reconstruction modes and It/sub combinations (except for 2/8). In case of the Hoffman 3D brain phantom the mean recovery of the cortical regions was 101% +/- 1.2 (the increase based on the uncorrected values: 35.5% +/- 1.5), while the subcortical regions reached a mean recovery of 80% with an increase of 43.9% +/- 2.5. For the human data, an increase of the metabolized values of several cortical regions ranged between 42% and 48% independent from the reconstruction mode. CONCLUSIONS: Our data show that the 3-compartment fully 3-D MR based PV-correction is sensitive to the choice of reconstruction algorithms and to the parameter choice. They indicate that despite improved spatial resolution, the use of the iterative reconstruction algorithm for PV-correction results in similar recovery factors when compared to a correction using DiFT reconstruction, insofar the image resolution values are fitted at the It/Sub combinations.

Algorithms↗

Fuzzy-rule-based image reconstruction for positron emission tomography.

Positron emission tomography (PET) and single-photon emission computed tomography have revolutionized the field of medicine and biology. Penalized iterative algorithms based on maximum a posteriori (MAP) estimation eliminate noisy artifacts by utilizing available prior information in the reconstruction process but often result in a blurring effect. MAP-based algorithms fail to determine the density class in the reconstructed image and hence penalize the pixels irrespective of the density class. Reconstruction with better edge information is often difficult because prior knowledge is not taken into account. The recently introduced median-root-prior (MRP)-based algorithm preserves the edges, but a steplike streaking effect is observed in the reconstructed image, which is undesirable. A fuzzy approach is proposed for modeling the nature of interpixel interaction in order to build an artifact-free edge-preserving reconstruction. The proposed algorithm consists of two elementary steps: (1) edge detection, in which fuzzy-rule-based derivatives are used for the detection of edges in the nearest neighborhood window (which is equivalent to recognizing nearby density classes), and (2) fuzzy smoothing, in which penalization is performed only for those pixels for which no edge is detected in the nearest neighborhood. Both of these operations are carried out iteratively until the image converges. Analysis shows that the proposed fuzzy-rule-based reconstruction algorithm is capable of producing qualitatively better reconstructed images than those reconstructed by MAP and MR P algorithms. The reconstructed images a resharper, with small features being better resolved owing to the nature of the fuzzy potential function.

Algorithms↗

Reconstruction of the flexor pulley. The effect of the tension and source of the graft in an in vitro dog model.

Flexor pulleys in the hindpaw digits of twenty-eight adult mixed-breed dogs were reconstructed in order to investigate the influence, on the reconstruction, of the source of the autogenous tissue (intrasynovial compared with extrasynovial tendon) and the tension applied during the repair. The ipsilateral peroneus longus tendon was used to reconstruct the A2 pulley with an around-the-bone technique in twenty-one digits; the graft was sutured at a tension of 0.49, 0.98, and 1.96 newtons in seven digits each. The flexor digitorum profundus tendon of an adjacent digit was used to reconstruct the A2 pulley, at a tension of 0.98 newton, in seven additional digits. The contralateral digits were used as controls for all twenty-eight treated digits. The digits were tested in a custom apparatus designed to measure the frictional force generated between the reconstructed pulley and the tendon beneath it. The frictional force did not differ significantly (p > 0.5) among the three groups repaired with peroneus longus tendon; however, the average value was more than five times that produced in the contralateral, control digits. The average frictional forces created by the flexor digitorum profundus grafts were similar to those in the contralateral, control digits. Reconstruction with the flexor digitorum profundus at a tension of 0.98 newton produced significantly less frictional force (p < 0.05) than that produced by the peroneus longus graft at the same tension. This in vitro model of reconstruction of the A2 pulley demonstrated that tendon from an intrasynovial source (the flexor digitorum profundus) produced less frictional resistance to gliding of the tendon than did tendon from an extrasynovial source (the peroneus longus). This result is consistent with previously published findings that intrasynovial tendons may make better grafts than extrasynovial tendons for the reconstruction of gliding flexor tendons because of decreased friction and better healing qualities. Intrasynovial tendons may also make better grafts for the reconstruction of flexor pulleys.

Animals↗