PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

Rapid quantification of hexachlorobenzene in the color additives D&C Red Nos. 27 and 28 (phloxine B) using solid-phase microextraction and gas chromatography-mass spectrometry.

The present paper describes the development of a method for the quantification of hexachlorobenzene (HCB) in the color additives D&C Red Nos. 27 and 28 (phloxine B) using solid-phase microextraction followed by gas chromatography-mass spectrometry (GC-MS) analysis. The method is simple and fast (1 h for each analysis), generates little solvent waste, and does not involve a solid matrix, thus permitting a more efficient extraction than does a previously developed Soxhlet extraction-GC-MS method. Test portions from 30 batches of US-certified color additives D&C Red Nos. 27 and 28 were analyzed for HCB using the new method. Those batches represent domestic (five) and foreign (one) manufacturers that requested certification for the colors during the past four years. All the samples contained HCB, ranging from 0.2 ppm to 244.3 ppm. The analyses revealed significant differences in the levels of HCB across batches from the same manufacturer as well as among different manufacturers. The range of HCB levels found in the analyzed batches (0.2-244.3 ppm) suggest that the contamination with HCB may be decreased by avoiding use of starting material (tetrachlorophthalic anhydride) heavily contaminated with HCB.

Coloring Agents↗

Solid-phase microextraction: a powerful sample preparation tool prior to mass spectrometric analysis.

Sample preparation is an essential step in analysis, greatly influencing the reliability and accuracy of resulted the time and cost of analysis. Solid-Phase Microextraction (SPME) is a very simple and efficient, solventless sample preparation method, invented by Pawliszyn in 1989. SPME has been widely used in different fields of analytical chemistry since its first applications to environmental and food analysis and is ideally suited for coupling with mass spectrometry (MS). All steps of the conventional liquid-liquid extraction (LLE) such as extraction, concentration, (derivatization) and transfer to the chromatograph are integrated into one step and one device, considerably simplifying the sample preparation procedure. It uses a fused-silica fibre that is coated on the outside with an appropriate stationary phase. The analytes in the sample are directly extracted to the fibre coating. The SPME technique can be routinely used in combination with gas chromatography, high-performance liquid chromatography and capillary electrophoresis and places no restriction on MS. SPME reduces the time necessary for sample preparation, decreases purchase and disposal costs of solvents and can improve detection limits. The SPME technique is ideally suited for MS applications, combining a simple and efficient sample preparation with versatile and sensitive detection. This review summarizes analytical characteristics and variants of the SPME technique and its applications in combination with MS.

Animals↗

Solid-phase microextraction gas chromatography/mass spectrometry: a new method for species identification of truffles.

This study describes a rapid method to identify different truffle species by analysis of their volatile compound fraction using static headspace solid-phase microextraction gas chromatography/mass spectrometry. The volatile organic compounds (VOCs) were extracted using a new 2-cm 50/30 microm DVB/CAR/PDMS fiber placed for 10 min in the headspace of the truffle sample with the vial maintained at 20 degrees C (in a thermostatically controlled analysis room). The mass spectra of the VOC chromatograms were represented as 'fingerprints' of the analysed samples. Next, stepwise factorial discriminant analysis afforded a limited number of characteristic fragment ions that allowed a classification of the truffle species studied. This new method provides an effective approach to rapid quality control and identification of truffle species by analysis of their volatile fraction. Moreover, this method offers the advantage of minimizing thermal, mechanical, and chemical modifications of the truffles, thereby reducing the risk of analytical artifacts.

Fungi↗

Solid-phase microextraction for gas chromatographic/mass spectrometric analysis of dimethoate in human biological samples.

A new, simple and rapid procedure for the determination of dimethoate in urine and blood samples was developed using direct immersion solid-phase microextraction and gas chromatography/mass spectrometry. This technique required only 0.1 mL of sample, and ethion was used as internal standard. Two types of coated fibre were compared (100 microm polydimethylsiloxane, and 65 microm Carbowax/divinylbenzene). Other parameters, such as extraction temperature, adsorption and desorption time, salt addition, agitation and pH, were optimized to enhance the sensitivity of the method. Limits of detection (LODs) and quantitation (LOQs) were 50 and 100 ng/mL for urine and 200 and 500 ng/mL for blood, respectively. The method was found to be linear between the LOQ and 40 microg/mL for urine, and between the LOQ and 50 microg/mL for blood, with correlation coefficients ranging from 0.9923-0.9996. Precision (intra- and interday) and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The mean absolute recoveries of dimethoate were 1.24 and 0.50% for urine and blood, respectively. Because of its simplicity and the fact that small volumes of sample are used, the described method can be successfully used in the diagnosis of poisoning by this pesticide, namely in those situations where the sample volume is limited, as frequently occurs in forensic toxicology.

Dimethoate↗

Use of headspace solid-phase microextraction and headspace sorptive extraction for the detection of the volatile metabolites produced by toxigenic Fusarium species.

An efficient methodology was developed to determine the growth of toxigenic Fusarium spp., based on headspace solid-phase microextraction (SPME) and stir bar sorptive extraction of the fungal volatile metabolites produced. SPME and headspace sorptive extraction (HSSE) were used to monitor the de novo production of sesquiterpene hydrocarbons, such as trichodiene, a volatile marker and intermediate in the biosynthesis of trichothecenes. On growth media such as malt extract agar and potato dextrose agar, it was found that trichodiene was produced by toxigenic strains of Fusarium sambucinum and Fusarium sporotrichioides. It was the main volatile metabolite in the headspace extract of the cultures. On the other hand, deoxynivalenol producing Fusarium graminearum showed a completely different pattern of volatile sesquiterpenes and could easily be distinguished from a zearalenone producing strain of F. graminearum based on the headspace profile. Hence, it can be concluded that headspace analysis of volatile fungal metabolites by SPME and HSSE in combination with gas chromatography/mass spectrometry is a suitable monitoring technique to differentiate toxigenic strains of Fusarium.

Fusarium↗

Rapid screening of polychlorinated biphenyls in sediments using non-equilibrium solid-phase microextraction and fast gas chromatography with electron-capture detection.

A rapid method for the screening of polychlorinated biphenyls (PCBs) in sediment samples is described. Analytes are concentrated on a poly(dimethylsiloxane) (PDMS) solid-phase microextraction (SPME) fibre, separated using a narrow-bore gas chromatography column (10 m x 0.1mm I.D.) and determined with a micro-electron-capture detector (micro-ECD). The narrow-bore column showed a similar separation efficiency to a conventional capillary one (30 m x 0.32 mm I.D.) and allowed a 3 times reduction in the analysis time. Moreover, thermal desorption of SPME fibres in the narrow-bore column did not produce any degradation in the quality of separations when compared to the split injection mode. The use of an oxidative sample treatment was mandatory to remove sulphur interferences in the chromatograms and increase the yield of PCBs during SPME for short sampling times. Under optimised conditions, a fraction of sediment (0.1-0.5 g) was mixed with 5 ml of a 0.2M potassium permanganate solution and 0.5 ml of sulphuric acid 6M in a 22 ml closed vessel. Sample treatment and headspace SPME of PCBs were performed simultaneously for 10 min at 100 degrees C. Globally, the whole analytical procedure takes about 20 min and presents quantification limits between 0.5 and 1.3 ng/g. Accuracy was evaluated by analysing a reference sediment sample with certified concentrations of several PCBs.

Chromatography, Gas↗

Evaluation of solid-phase microextraction conditions for the determination of chlorophenols in honey samples using gas chromatography.

A rapid and solvent-free method for the determination of nine chlorophenol (CP) compounds in honey samples using headspace solid-phase microextraction (HS-SPME) and gas chromatography with atomic emission detection (GC-AED) is developed. The different factors affecting the efficiency of the extraction and derivatization steps were carefully optimized. The polydimethylsiloxane-divinylbenzene (PDMS/DVB) fiber was the most suitable for preconcentrating the analytes from the headspace of an aqueous solution containing the dissolved honey samples where the chlorophenols had been submitted to acetylation. When the matrix effect was evaluated for different samples, it was concluded that standard addition calibration was required for quantification purposes. Detection limits roughly ranged from 0.1 to 2.4 ng g(-1), depending on the compound and the honey sample analyzed, with a fiber time exposure of only 15 min at 75 degrees C. The optimized method was successfully applied to different samples, some of the studied chlorophenols being detected in some of the analyzed honeys at concentration levels 0.6-9.4 ng g(-1).

Chlorophenols↗

Determination of menthol in plasma and urine of rats and humans by headspace solid phase microextraction and gas chromatography--mass spectrometry.

A method for the determination of menthol and menthol glucuronide (M-G) after enzymatic hydrolysis in plasma and urine of rats and humans was developed using headspace solid phase microextraction and gas chromatography-mass spectrometry in the selected ion monitoring mode (HS-SPME/GC-MS). The assay linearity for plasma ranged from 5 to 1000 ng/ml. The limit of quantification (LOQ) in plasma was 5 ng/ml. The intra- and inter-day precision for menthol and M-G were < or = 18.1% R.S.D. at the LOQ and < or = 4.0% at higher concentrations. Menthol and M-G were determined in rat and human plasma and urine after administration of menthol.

Animals↗

Quantification of volatile sulfur compounds in complex gaseous matrices by solid-phase microextraction.

Procedures were assessed for quantifying nine volatile sulfur compounds found in complex gaseous samples collected at a biogas-production plant and a sewage treatment plant. The target compounds were extracted by solid-phase microextraction (using the 75-microm Carboxen-polydimethylsiloxane fiber coating) at 22 degrees C for 20 min, and analyzed by GC-MS. Detection limits ranged between 1 pptv (v/v) for carbon disulfide and 470 pptv (v/v) for hydrogen sulfide. High amounts of organic compounds were found during full-scan analysis of the samples and standard additions to individual sub-samples revealed that the analysis was subject to matrix effects. However, the functions obtained by standard additions were still linear and quantification was possible for all the compounds tested except hydrogen sulfide. No detectable losses were observed during storage in the sampling containers, made of Tedlar film, over a storage period of 20 h. However, water permeated through the walls and the relative humidity in the bag increased during storage until it reached the ambient level. Finally, it was shown that the drying agent, CaCl2, caused no detectable losses of any of the compounds.

Gas Chromatography-Mass Spectrometry↗

Quantitation of amphetamine, methamphetamine, and their methylenedioxy derivatives in urine by solid-phase microextraction coupled with electrospray ionization-high-field asymmetric waveform ion mobility spectrometry-mass spectrometry.

Amphetamine, methamphetamine, and their methylenedioxy derivatives have been identified and measured in a human urine matrix using solid-phase microextraction (SPME) and high-field asymmetric waveform ion mobility spectrometry (FAIMS) in combination with electrospray ionization (ESI) and mass spectrometric detection (MS). Limits of detection in human urine between 200 pg/mL and 7.5 ng/mL have been achieved. The use of a simple extraction method, SPME, combined with the high sensitivity and selectivity of ESI-FAIMS-MS eliminates the need for chromatographic separation and allows for very rapid sample processing.

3,4-Methylenedioxyamphetamine↗

Sorption of pyrene to dissolved humic substances and related model polymers. 2. Solid-phase microextraction (SPME) and fluorescence quenching technique (FHT) as analytical methods.

Sorption coefficients for pyrene on dissolved humic substances and on poly(acrylic acid) esters as well-defined model polymers were determined using solid-phase microextraction (SPME) and the fluorescence quenching technique (FQT). The results of both analytical methods were compared and theoretically evaluated, which led to the conclusion that the sorption coefficients measured by SPME and FQT are inevitably different: SPME measures activity-based and FQT concentration-based sorption coefficients. The environmental relevance of the two types of sorption coefficients is discussed. FQT is inappropriate to measure sorption coefficients for pyrene with the synthetic sorbents. Inspection of the vibrational structure of the fluorescence spectra of those solutions indicates a highly hydrophobic microenvironment of pyrene. This can be explained by an intra- or intermolecular agglomeration of hydrophobic moieties forming a favorable host for hydrophobic solutes.

Adsorption↗

Quantitative determination of short-chain free fatty acids in milk using solid-phase microextraction and gas chromatography.

The objective was to establish a rapid, precise, and accurate methodology for the quantification of short-chain free fatty acids (FFA) (C(4)-C(12)) in milk by solid-phase microextraction and gas chromatography. Sampling conditions such as fiber type, pH, salt addition, temperature, volume, and time were investigated. FFA extraction consisted of placing 40 mL of milk containing 28% NaCl at pH 1.5 in a sealed vial and equilibrating for 30 min at 70 degrees C. A polyacrylate fiber was exposed to the sample headspace for 60 min and desorbed for 5 min into the gas chromatograph. Calibration curves for FFA followed linear relationships with highly significant (p < 0.001) correlation coefficients (R(2) = 0.99). Coefficients of variation of less than 7.7% for FFA concentrations indicated that the technique was reproducible. The limits of quantification for C(4)-C(10) were in the low parts per million level, which were below the concentration range found in fresh pasteurized milk (0.48-2.52 ppm) or rancid milk (4.73-32.31 ppm).

Animals↗

The confirmation of volatiles by solid-phase microextraction and GC-MS in the investigation of two traffic fatalities.

A simple, sensitive, and reliable method was developed for the confirmation of nonroutine volatiles in the investigation of two traffic fatalities. Solid-phase microextraction (SPME) fibers were used to extract volatile compounds from the headspace of sample vials; components were subsequently analyzed by gas chromatography-mass spectrometry (GC-MS). In the first case, ethanol and methylene chloride were detected in a urine sample by headspace SPME and GC-MS. The second case involved the analysis of volatile petroleum products from submitted specimens by headspace SPME and GC-MS. In both cases, SPME and GC-MS analyses provided crucial evidence in the investigation of the traffic fatalities.

Accidents, Traffic↗

Simultaneous determination of volatile and semi-volatile aromatic hydrocarbons in virgin olive oil by headspace solid-phase microextraction coupled to gas chromatography/mass spectrometry.

A reliable, simple and relatively fast method for the simultaneous determination of volatile and semi-volatile aromatic hydrocarbons in virgin olive oil was developed, based on headspace solid-phase microextraction (HS-SPME). The investigation regarded eco-contaminants such as alkylated monoaromatic hydrocarbons from C1- to C4-benzenes and light polyaromatic hydrocarbons up to four aromatic rings. Sampling and chromatographic conditions were optimized by using standard solutions in deodorized olive oil and the analytical performances of the method were determined. The proposed method was then applied to real samples of virgin olive oil were the target hydrocarbons could be identified and quantified. Several of them had not been previously quantified in virgin olive oil. Moreover, by the analysis of olive oil samples an additional number of C4-benzenes could be tentatively identified.

Chemical Fractionation↗

Determination of phosphoric acid triesters in human plasma using solid-phase microextraction and gas chromatography coupled to inductively coupled plasma mass spectrometry.

A simple and sensitive method for determination of phosphoric acid triesters at trace levels in human plasma sample is described. In this work, solid-phase microextraction (SPME) is employed as a sample preparation procedure for extraction and pre-concentration of alkyl and aryl phosphates followed by gas chromatography coupled to inductively coupled plasma mass spectrometry (GC-ICP-MS) for phosphorus-specific and very sensitive determination of these compounds in human plasma. The detection limits from blood plasma were 50 ngL(-1) (tripropyl phosphate), 17 ngL(-1) (tributyl phosphate), 240 ngL(-1) (tris(2-chloroethyl) phosphate) and 24 ngL(-1) (triphenyl phosphate). Sample preparation involves plasma deproteinization followed by direct immersion SPME with 65 microm poly(dimethylsiloxane/divinylbenzene) fiber. Extraction was performed at 40 degrees C for 30 min and at pH 7.0 in 10 mM sodium carbonate buffer. The reported method, to our knowledge, describes the first application of SPME with element-specific detection for analysis of phosphoric acid esters. Application of the method to the plasma samples, previously stored in poly(vinyl chloride) plasma bags revealed the presence of triphenyl phosphate, which was further confirmed by SPME GC time-of-flight high-resolution mass spectrometry.

Chemical Fractionation↗

Solid phase microextraction for analysis of alkanes and aromatic hydrocarbons in human breath.

In this work, solid phase microextraction-gas chromatograph (SPME-GC) was applied to analyze alkanes and aromatic hydrocarbons in human breath, providing a potential non-invasive method to screen lung cancer. This method has been optimized and evaluated. It provided quantification limits ranging from 0.04 to 4.2 ng/mL, linear correlations ranging from 0.9845 to 0.9966 and R.S.D. values less than 9.8%. Total 30 breath samples, from 15 lung cancer patients and 15 healthy persons, were analyzed, and the alkanes and aromatic hydrocarbons were detected in 73.3% lung cancer patients and in 13.3% healthy persons by this method. Above all, It was demonstrated that this SPME-GC method provided a sensitive and non-invasive measure means to analyze alkanes and aromatic hydrocarbons in human breath, and brought forward a potential application for screening lung cancer.

Aged↗

Fast detection of fluoroacetamide in body fluid using gas chromatography-mass spectrometry after solid-phase microextraction.

A novel method for fast determination of fluoroacetamide, a kind of organic fluorine pesticide, in blood and urine samples was developed with acetamide as an internal standard using gas chromatography/mass spectrometry (GC/MS) after solid-phase microextraction (SPME) technique. The SPME was performed by immersing a PDMS fiber of 100 microm coating thickness in a sample solution for 25 min at 70 degrees C with (CH(3)CH(2))(4)NBr to improve the extraction efficiency. After a GC sample injection, the extracted fluoroacetamide was desorbed from the fiber for 4 min to perform the GC/MS detection with a HP-PLOT Q capillary column. The analytical conditions were optimized by examining systematically, the effects of experimental parameters on the ratio of characteristic ion peak areas of fluoroacetamide to acetamide. Under optimal conditions, the ratio was proportional to the concentration of fluoroacetamide ranging from 5.0 to 90 microg/ml with a detection limit of 1.0 microg/ml. The average recovery of fluoroacetamide in blood sample was 92.2%. The established method could be used for the fast and convenient measurement of fluoroacetamide in poisoned sample.

Body Fluids↗

Biological sample analysis with immunoaffinity solid-phase microextraction.

A theophylline antiserum was covalently immobilized on the surface of a fused silica fiber, modified with 3-aminopropyltriethoxysilane (APTES) and glutaraldehyde, and used as a selective and sensitive extraction medium for the immunoaffinity solid-phase microextraction (SPME) determination of theophylline in serum samples. The specificity of the immunoaffinity SPME fiber was first investigated using a fixed concentration of [3H]theophylline together with various amounts of interference, possessing no cross-reactivity with the theophylline antibody. No significant non-specific binding was observed. The reproducibility of the fiber preparation and the immunoaffinity SPME analysis was also investigated, resulting in a relative standard deviation of 6.1% for five analyses of the same fiber. The antigen-antibody binding isotherm was obtained by analyzing theophylline standards of various concentrations (0.1-5 ng mL(-1)) until saturation values were reached. Initial binding of theophylline was linear with a r2 = 0.968. The cross-reactivity of the theophylline immunoaffinity SPME fiber for the structural analog caffeine was investigated by adding various amounts of caffeine in the presence of theophylline at a saturation concentration and produced a low cross-reactivity value of 0.1%. Finally. spiked serum samples (10 and 50 ng mL(-1)) were successfully analyzed with an excellent correlation with the standard binding isotherm, thus confirming the performance of the immunoaffinity SPME coating for improved bioanalysis.

Animals↗