PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “surface modification”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

Chemical modification of surface active poly(ethylene oxide)-poly (propylene oxide) triblock copolymers.

A general route has been developed to chemically modify a series of poly(ethylene oxide)-poly(propylene oxide) triblock copolymers with molecular weights from 6500 to 14600. It is initiated by the introduction of p-nitrophenyl groups; such nitrophenyl conjugated copolymers are stable in an organic milieu and in a dry state but are seen to react easily with amino-containing molecules including small peptides. Among them, introduction of 2-pyridyl disulfide groups after coupling with 2-(2-pyridyldithio)ethylamine enables the selective attachment of thiol-containing molecules. The released thiopyridone in such thiol-disulfide reactions can be used to quantify the content of 2-pyridyl disulfide groups. In addition, a new type of modified copolymers was developed for the radioisotope (125I) labeling purpose that consists of a reaction of nitrophenyl conjugated copolymers with hydrazine and a subsequent coupling with N-succinimidyl 3-(4-hydroxyphenyl)propionate (Bolton-Hunter reagent). Adsorption studies of 125I-labeled and 2-pyridyl disulfide conjugated copolymers on polystyrene particles are consistent with previous determinations of surface coverage using other technologies, in turn indicating that this new chemical modification does not alter their surfactant properties on hydrophobic solid phase. The coating of common hydrophobic surfaces with 2-pyridyl disulfide conjugated copolymers has been demonstrated as a general and robust immobilization method to generate a high-sensitivity bioactive surface with low nonspecific binding. The optimal space between immobilized ligands can also be controlled by incubating the solid phase with solutions containing mixtures with different ratios of unmodified and modified copolymers.

Chemical Phenomena↗

A packaging technique for polymer microfluidic platforms.

A new technique, resin-gas injection, has been developed for bonding and surface modification of polymer microfluidic devices. This method can easily bond biochips with complex flow patterns. A cascade micromixer and a multichannel DNA sequencing chip were demonstrated experimentally. By adding surface modification agents, the interfacial free energy of the substrate with water can be controlled. Local modification of the channel surface can also be achieved through sequential resin-gas injection in conjunction with a masking technique. For application, this technique is used to form a layer of dry monolithic stationary hydrogel on the walls of a microchannel, serving as a sieving material for electrophoresis separation of DNA fragments. The reagent loading and the electrophoresis separation efficiency of this technique were compared experimentally with the conventional linear polymer solution method used in the microchannel-based DNA sequencing process. It is found that our method has the advantages of more user-friendly operation, easier and faster sample loading, but slightly less separation efficiency.

DNA↗

Modification of surface marker expression on CD14 monocytes of allergic patients after lysis or Ficoll purification.

It has been observed that peripheral blood monocytes are often in a primed or activated state in inflammatory diseases such as asthma. However, the majority of these studies have been performed using cells which have been purified by density gradient centrifugation on Percoll or Ficoll-Hypaque. Using cytofluorimetry, we compared the expression of monocyte surface markers of monocytes from untreated blood with monocytes purified by erythrocyte lysis or density centrifugation using the Ficoll technique. Monocytes from two groups of subjects were analyzed: healthy subjects and allergic patients. When compared with untreated blood, the percentage of CD16-positive cells, and the sMFI was significantly greater after monocyte purification (lysis or Ficoll). The expression of CD62L (percentage and sMFI) was modified after monocyte purification. Such modification of these two surface markers was predominantly observed on monocytes from allergic patients, and not on monocytes from healthy subjects. This study suggests that surface marker analysis should be performed on unfractionated whole blood in order to avoid modification of monocyte antigens.

Cell Separation↗

Surface grafting of poly(ethylene glycol) onto poly(acrylamide-co-vinyl amine) cross-linked films under mild conditions.

Poly(ethylene glycol) (PEG) was grafted onto poly(acrylamide-co-vinyl amine) (poly(AM-co-VA)) film using tresylated PEG (TPEG) at 37 degrees C in aqueous buffers (pH 7.4) with a view to surface-modifying microencapsulated mammalian cells. Poly(AM-co-VA) film was synthesized by Hofmann degradation of a cross-linked poly(acrylamide) film. Conversion to vinyl amine on the surface of the film was approximately 50%, but bulk conversion was not observed; surface specificity was thought to be the result of cleavage of aminated polymer chains at the surface due to chain scission. Reaction between primary amine and TPEG gave a graft yield of 2 mol% (based on XPS) with respect to available surface amine groups, equivalent to 54 mol% ethylene oxide based on monomer units. Physical adsorption of non-activated polymer was done under identical conditions as a control and the difference in oxygen content was significant compared to TPEG. The type of buffer agent and buffer concentration did not influence graft yields. This graft reaction, which was completed in as little as 2 h was considered to be mild enough to be used for a surface modification of microcapsules containing cells without affecting their viability. Such a surface modification technique may prove to be a useful means of enhancing the biocompatibility of microcapsules (or any tissue engineering construct) even after cell encapsulation or seeding.

Acrylic Resins↗

Surface charge modifications do not affect the hydrolytic activity of membrane-bound pyrophosphatase of Rhodospirillum rubrum.

The surface charge of the membrane of chromatophores of Rhodospirillum rubrum was modified by two methods: fusion of liposomes with the membrane of the chromatophore by changing the pH and by incubating chromatophores in the presence of cationic or anionic detergents. The hydrolytic activity of membrane-bound pyrophosphatase, on surface charge modified chromatophores, did not change the Km of the enzyme for its substrate (Mg-PPi2-) nor the activation effect of free Mg2+ on the hydrolytic activity. This membrane enzyme is not regulated by surface charge.

Bacterial Chromatophores↗

Cellular fate of a modular DNA delivery system mediated by silica nanoparticles.

Development of efficient molecular medicines, including gene therapeutics, RNA therapeutics, and DNA vaccines, depends on efficient means of transfer of DNA or RNA into the cell. Potential problems, including toxicity and immunogenicity, surrounding viral methods of DNA delivery have necessitated the use of nonviral, synthetic carriers. To better design synthetic carriers, or transfection reagents, the modular design of viruses has inspired a modular approach to DNA and RNA delivery. Each modular component can be designed to circumvent each of the many barriers. The modular approach will allow modification of individual components for a specific application. By utilizing a dense silica nanoparticle to form a ternary complex, transfection efficiency of a DNA-transfection reagent complex was increased by a factor of approximately 10 by concentrating the DNA at the surface of cells. Surface modification of the silica nanoparticles allowed determination of the cellular uptake mechanism with only minor alteration of transfection efficiency. Nanoparticles are internalized by an endosome-lysosomal route followed by perinuclear accumulation. The modification mechanism confirms that surface modification of the modular system can allow specific moieties to be incorporated into the modular system without significant alteration of the transfection efficiency. By showing that the modular system based upon concentration of DNA at the level of the cell can be used to increase transfection efficiency, we have shown that further modification of the system may better target DNA delivery and overcome other barriers of DNA expression.

Animals↗

Inhibition of platelet adhesion to glow discharge modified surfaces.

Plasma glow technique has created much interest in the field of surface modification of polymers due to its versatility of generating active polar groups on the surface without affecting the bulk properties. Here an attempt is made to inter-relate the surface properties and platelet adhesion on various polymeric substrates due to plasma treatments. Initially, a critical review of the process and development of thrombosis upon contact of an artificial surface with blood, has been provided, which has been extended with the need for surface modifications to improve their blood compatibility and the versatility of plasma treatments for such modifications have been emphasized. Phospholipids like phosphoryl choline, phosphatidyl choline and phosphoryl ethanolamine were attached to Angioflex surface by plasma glow. The role of such modified substrates to interact with platelets were investigated using Tyrode washed calf platelets. It seems, glow discharge modified phosphoryl choline bilayers dramatically inhibited the platelet-surface binding, which may be due to their biochemical resemblance with thromboresistant surfaces of human blood cells. Further, the behaviour of all phospholipids towards bloodpolymer interaction is not similar and may change depending on the nature of their functional groups, net charge of the phospholipid adsorbed surface and their interaction with platelets and its activation. It is possible to chemically immobilize lipid bilayers on standard polymers, using plasma glow, to improve their biological performance; by suitably selecting the phospholipid combinations.

Adhesiveness↗

Leukocyte adhesion on model surfaces under flow: effects of surface chemistry, protein adsorption, and shear rate.

The effect of specific chemical functionalities on the adhesion of polymorphonuclear leukocytes (PMNs) under flow was investigated using a set of well-characterized, chemically functionalized surfaces prepared by self-assembly of alkanethiolate monolayers on gold surfaces. Terminal functionalities included CH(3), CH(2)OH, COOH, and (OCH(2)CH(2))(3)OH groups. A new surface modification was used to incorporate a phosphorylcholine moiety on the hydroxyl-terminated monolayer. Surface modification was verified using contact-angle measurements, ellipsometry, and X-ray photoelectron spectroscopy. Adhesion on the surfaces was studied in the presence and absence of pre-adsorbed fibrinogen. Fibrinogen adsorption on self-assembled monolayers (SAMs) was quantified using radioisotope detection. PMN adhesion was found to be dependent on the monolayer's terminal functionality. Adhesion was higher on the hydrophobic CH(3) surface and the polar COOH monolayer. Leukocyte adhesion was least on the phosphorylcholine-rich surface, followed by the ethylene-oxide-containing monolayer. Cell adhesion also was low on the hydrophilic OH monolayer. Attachment was decreased with increasing shear rate, exhibiting a three-fold decrease between 20 and 100 s(-1). Fibrinogen adsorption was higher on the CH(3) monolayer but comparable for the other four SAMs. Preincubation of the surfaces with fibrinogen decreased adhesion on all SAMs examined.

Biocompatible Materials↗

A method for UV-bonding in the fabrication of glass electrophoretic microchips.

This paper presents an approach for the development of methodologies amenable to simple and inexpensive microchip fabrication, potentially applicable to dissimilar materials bonding and chip integration. The method involves a UV-curable glue that can be used for glass microchip fabrication bonding at room temperature. This involves nothing more than fabrication of glue "guide channels" into the microchip architecture that upon exposure to the appropriate UV light source, bonds the etched plate and cover plate together. The microchip performance was verified by capillary zone electrophoresis (CZE) of small fluorescent molecules with no microchannel surface modification carried out, as well as with a DNA fragment separation following surface modification. The performance of these UV-bonded electrophoretic microchips indicates that this method may provide an alternative to high temperature bonding.

Adhesives↗

Enhanced adherence of human adult endothelial cells to plasma discharge modified polyethylene terephthalate.

Human adult aortic endothelial cell attachment to polyethyleneterephthalate (PET as mylar film) was examined in vitro. PET was examined in both the unmodified form (PET-) and in a modified form (PET+) that had undergone plasma discharge surface modification (PDSM). These surfaces were compared to unmodified tissue culture polystyrene (PS-). The kinetics of attachment and the force of attachment using the rotating disc were determined as a function of surface and substrate protein applied to the surface. Four proteins--fibronectin, collagen I/III, collagen IV/V, and laminin--were added and compared to saline pretreatment. The most significant variable affecting attachment was the time of incubation. When corrected for time, PET+ demonstrated significantly superior attachment kinetics when compared to PET- in most cases. These kinetics were similar to those seen on PS-. Fibronectin precoating of the surface greatly enhanced attachment kinetics on PET+ and PS- but to a much lesser degree on PET-. The fibronectin effect was synergistic with PDSM, suggesting that PDSM enhances protein adsorption on the surface. The force of attachment was generally independent of incubation time and surface/substrate combination except for laminin precoating. Taken together, these data indicate that human endothelial cell adherence to PET may be significantly enhanced by PDSM and surface precoating with fibronectin. Attachment occurs rapidly and, once attached, the cells demonstrate a very firm attachment force capable of resisting shear stresses up to 90 dynes/cm2.

Cell Adhesion↗

Doxorubicin-encapsulated thermosensitive liposomes modified with poly(N-isopropylacrylamide-co-acrylamide): drug release behavior and stability in the presence of serum.

In the field of the temperature sensitive drug delivery systems, we studied on the surface modification of liposomes by using poly(N-isopropylacrylamide-co-acrylamide) (PNIPAM-AAM) and polyethyleneglycol (PEG) to increase the release of doxorubicin (DOX) from liposomes and prolong the stability of liposomes in the presence of serum. The release of DOX from the PNIPAM-AAM/PEG modified liposomes is enhanced around the transition temperature of the polymer. In addition, the stability of the PNIPAM-AAM/PEG modified liposomes in serum shows a high level comparing with polymer unmodified liposomes. These results suggest that the modification on the surface of liposomes with both PNIPAM-AAM and PEG enhances the drug release from liposomes and reduces the protein adsorption in serum.

Acrylic Resins↗

Influence of the physicochemical properties of liposomes on the accelerated blood clearance phenomenon in rats.

We have recently reported that PEGylated liposomes (PL) are cleared rapidly from the blood circulation when they are administered twice in the same rat at certain intervals, even if the liposomes are sterically stabilized by a surface modification with PEG (referred to as the accelerated blood clearance (ABC) phenomenon, J. Control. Release, 88, 35-42 (2003)). Now we report on the influence of physicochemical properties (PEG-modification, size and surface charge) of either the first or the second dose of liposomes on the ABC phenomenon. When, for the first dose, conventional liposomes (CL; without a PEG coating) of 110-nm diameter were injected, only a very slight ABC phenomenon was observed, irrespective of the liposomal surface charge: both clearance rate and hepatic accumulation of the second injected PL were only slightly enhanced compared to those of a single dose of PL. Interestingly, when for the first injection small-size liposomes (60 nm) were used, either charged or PEG-modified, but not neutral, the ABC phenomenon was clearly manifest. Apparently, the induction of the ABC phenomenon is not only determined by the PEG coating but also by the size and surface charge of the first dose of liposomes. Also when for the second dose small-size PEGylated liposomes were used, the ABC phenomenon was observed after induction by a first injection of PL, whereas plasma kinetics and organ uptake of a second dose of negatively charged CL (NCL, 110 nm) or small-sized NCL (SNCL, 60 nm) were not altered. Apparently, the PEG coating on the second dose is essential for the liposomes to be susceptible to the ABC phenomenon. The results reported here suggest that the physicochemical properties of both the first and second dose of liposomes are important either for the induction of the phenomenon or for its expression. Our observations may have a considerable impact on the clinical application and engineering of liposomal formulations for use in multiple drug therapy.

Animals↗

Large-area patterning of coinage-metal thin films using decal transfer lithography.

We describe two new procedures that appear to hold significant promise as means for patterning thin-film microstructures of the coinage metals (Cu, Ag, Au). A feature central to both is the modification of their surfaces to promote the adhesive transfer of PDMS thin-film microstructures, a material suitable for use as resist layers in large-area patterning, using Decal Transfer Lithography (DTL). The present work provides a significant extension of the capabilities of DTL patterning, providing general protocols that can be used to transfer decal resists to essentially any substrate surface. The first method involves the functionalization of a surface, specifically those of gold and silver films with a thiol-terminated silane coupling agent, (mercaptopropyl)trimethoxysilane. This self-assembled monolayer, when hydrolyzed to its silanol form, provides a robust adhesion-promoting layer suitable for use in DTL patterning. The second method exploits the surface chemistry provided by the deposition of a nanoscale silicon dioxide thin-film capping layer using e-beam evaporation. This procedure provides an exceptional method for patterning large-area, thin-film microstructures of Cu-one compatible with micrometer-scale design rules-that are essentially defect free. Both surface modification strategies enable high-quality poly(dimethylsiloxane) decal transfers, and as the current work shows, these structures are suitable for large-area micrometer-sized patterning of gold, silver, and copper thin films via both wet-etching and lift-off procedures.

Journal Article↗

Biomaterials and biomedical devices.

This review discusses the factors important in the incorporation or integration of biomaterials and devices by tissue. Methods for surface modification and surface-sensitive techniques for analysis are cited. In vitro methods to evaluate the biocompatibility or efficacy of certain biomaterials and devices are presented. Present and future directions in neural prostheses, cardiovascular materials, blood or bone substitutes, controlled drug delivery, orthopedic prostheses, dental materials, artificial organs, plasma- and cytapheresis, and dialysis are discussed.

Artificial Organs↗

Effects of combined clomiphene citrate and exogenous oestrogen or progesterone on the vaginal epithelium of ovariectomised rats.

The interactive effects of clomiphene citrate (CC) and exogenous oestrogen (E2) or progesterone (P4), on the vaginal epithelium of ovariectomised rats were examined using scanning electron microscopy and light microscopy. Results were compared with P4E2 treatment. Statistical analysis showed no significant difference between the two combination CC treatments. All treatment groups had the ability to stimulate a dormant epithelium and cause surface modifications in the form of individually elongated microvilli and rosette formations. The results of this study indicate that while P4 enhances the oestrogenicity of CC, there is no cumulative oestrogenic effect when E2 and CC are combined, but there is modification of cell surface organisation and evidence of anti-oestrogenic activity.

Animals↗

Nanotoxicology: an emerging discipline evolving from studies of ultrafine particles.

Although humans have been exposed to airborne nanosized particles (NSPs; < 100 nm) throughout their evolutionary stages, such exposure has increased dramatically over the last century due to anthropogenic sources. The rapidly developing field of nanotechnology is likely to become yet another source through inhalation, ingestion, skin uptake, and injection of engineered nanomaterials. Information about safety and potential hazards is urgently needed. Results of older biokinetic studies with NSPs and newer epidemiologic and toxicologic studies with airborne ultrafine particles can be viewed as the basis for the expanding field of nanotoxicology, which can be defined as safety evaluation of engineered nanostructures and nanodevices. Collectively, some emerging concepts of nanotoxicology can be identified from the results of these studies. When inhaled, specific sizes of NSPs are efficiently deposited by diffusional mechanisms in all regions of the respiratory tract. The small size facilitates uptake into cells and transcytosis across epithelial and endothelial cells into the blood and lymph circulation to reach potentially sensitive target sites such as bone marrow, lymph nodes, spleen, and heart. Access to the central nervous system and ganglia via translocation along axons and dendrites of neurons has also been observed. NSPs penetrating the skin distribute via uptake into lymphatic channels. Endocytosis and biokinetics are largely dependent on NSP surface chemistry (coating) and in vivo surface modifications. The greater surface area per mass compared with larger-sized particles of the same chemistry renders NSPs more active biologically. This activity includes a potential for inflammatory and pro-oxidant, but also antioxidant, activity, which can explain early findings showing mixed results in terms of toxicity of NSPs to environmentally relevant species. Evidence of mitochondrial distribution and oxidative stress response after NSP endocytosis points to a need for basic research on their interactions with subcellular structures. Additional considerations for assessing safety of engineered NSPs include careful selections of appropriate and relevant doses/concentrations, the likelihood of increased effects in a compromised organism, and also the benefits of possible desirable effects. An interdisciplinary team approach (e.g., toxicology, materials science, medicine, molecular biology, and bioinformatics, to name a few) is mandatory for nanotoxicology research to arrive at an appropriate risk assessment.

Aerosols↗

The behavior of platelets at foreign surfaces.

Many conditions affect the interaction of platelets with foreign surfaces, including the type of surface, modifications of the surface, conditions of blood flow, the adsorbed layer of plasma proteins, changes in this protein layer with time, and the animal species in which experiments are done. Platelets probably never adhere directly to a foreign surface in vivo, because upon exposure of the surface to blood, plasma proteins, principally fibrinogen, are adsorbed almost immediately. When platelets adhere to such a surface and spread on it, they are activated in much the same way as when they are exposed to a strong aggregating and release-inducing agent, but in contrast to aggregation caused by some agonists, adhesion is not dependent on the formation of TXA2 or the release of ADP. It does appear to depend on external Ca2+. Much less is known about the initial adhesion reaction than about platelet aggregation (thrombus formation) on the adherent platelets, although the morphological changes resulting from adhesion have been described. It is surmised that the metabolic and cytoskeletal changes upon adhesion are similar to those that are involved in the response of platelets to other activating agents. The consequences of adhesion include the formation of thrombi and thromboemboli, thrombocytopenia, reduced platelet survival, reduced platelet function in response to hemostatic stimuli, and the appearance in the circulation of products released or formed by activated platelets. Many efforts are being made to develop surfaces and to set up conditions that will minimize platelet adhesion, but it has not yet been possible to find a foreign surface that has and can maintain the nonthrombogenic characteristics of the normal endothelium.

Animals↗

Surface analysis and effects on interfacial bone microhardness of collagen-coated titanium implants: a rabbit model.

PURPOSE: The aim of this study was to evaluate the surface chemistry and the microhardness at the implant-bone interface using a recently developed collagen-coated titanium implant in a short-term rabbit model. MATERIALS AND METHODS: Surface chemistry was evaluated by x-ray photoelectron spectroscopy (XPS), while in vivo studies involved 4-week implants mid-diaphysis in the lateral femurs of adult male rabbits. After conventional embedding and evaluation of histologic sections, the resinembedded blocks containing the implanted screws were used to measure bone hardness by means of an indentation test. RESULTS: Decomposition of the C1s peak obtained by XPS analysis confirmed that surface-immobilized collagen retained all the molecular features of the control, nonimmobilized reference. As to microhardness measurement, newly formed bone at the collagen-coated-implant/bone interface was significantly harder than bone at the interface of the uncoated control implant and bone. DISCUSSION: These results suggested that collagen coating significantly improves bone maturation and mineralization at the interface in comparison with uncoated commercially pure titanium. Surface modification of titanium implants by collagen coating has recently been discussed as a promising approach to the biochemical modification of implant surfaces. The present results support previous histologic findings and demonstrated that the biomolecular layer linked over the titanium implant can increase the bone healing rate, at least in this animal model. CONCLUSIONS: The present microhardness measurement at the bone-implant interface showed that collagen coating can significantly improve bone maturation and mineralization at the interface in comparison with uncoated commercially pure titanium, confirming and substantiating previous findings by histomorphometric measurements from the same model.

Animals↗