The ability of quantitative ultrasound to predict the mechanical properties of trabecular bone under different strain rates.

The ability of quantitative ultrasound to predict the mechanical properties of trabecular bone under different strain rates was investigated. Ultrasound velocity (UV) and broadband attenuation (BUA) were measured for 60 specimens of human trabecular bone. Samples were divided into two equal groups and loaded in compression at the strain rates of 0.0004 and 0.08 s-1. The ultimate strength, elastic modulus, and energy absorption capacity were determined for each specimen. Specimens tested at 0.08 s-1 had a mean value of strength 63% higher than the specimens tested at 0.0004 s-1. The elastic modulus and energy absorption capacity were 82% and 42% higher, respectively, for the higher strain rate. UV and BUA were significantly associated with most mechanical properties at both strain rates. All mechanical properties were also correlated strongly with a linear combination of UV and BUA for both the low and high loading rates. The use of ultrasound parameters may provide good clinical means for assessing the resistance of trabecular bone to both low and high energy trauma.

Aged↗

Tensile stress-strain characteristics of the human meniscal material.

The nonlinear stress-strain characteristics of the human menisci were determined by uniaxial elongation tests performed on circumferential and radial specimens prepared from different regions, layers, and locations. The properties of the collagen fibers and the matrix were calculated using the test results along with the values of the volume fractions of the meniscal components. Regression analysis showed that only three parameters, the elastic modulus, the maximum strain, and the strain intersect, are sufficient to define the nonlinear stress-strain relation up to failure. For radial specimens, the layer had a significant effect (p < 0.01) on the elastic modulus and the maximum strain, but had no effect on the strain intersect and the maximum stress. For the same specimens, the region had a significant effect (p < 0.01) only on the strain intersect and the maximum stress. For circumferential specimens, analysis indicated no significant effect of either the region, the layer, or the location of the specimens on the material parameters defining the stress-strain relation.

Adult↗

Biomechanical adaptation of porcine carotid vascular smooth muscle to hypo and hypertension in vitro.

Previous research in arterial remodeling in response to changes in blood pressure seldom included both hyper- and hypotension. To compare the effects of low and high pressure on arterial remodeling and vascular smooth muscle tone and performance, we have utilized an in vitro model. Porcine carotid arteries were cultured for 3 days at 30 and 170mmHg and compared to controls cultured at 100mmHg for 1 and 3 days. On the first and last day of culture, pressure-diameter and pressure-wall thickness curves were measured under normal smooth muscle tone using a high-resolution ultrasonic device. Last-day experiments included measurements where vascular smooth muscle was contracted or totally relaxed. From the data wall cross-sectional area, Hudetz elastic modulus and a contraction index related to the diameter reduction under normal smooth muscle tone were calculated. We found that although wall cross-sectional area (indicating wall mass) did not change much, Hudetz elastic modulus was significantly reduced in the 3-day hypotension group. Inspection of the wall contraction index suggests that this is due to a reduction in the vascular smooth muscle tone. Further, the peak of contraction index was found to be shifted to higher pressures in the 3-day 170mmHg group. We conclude that vascular smooth muscle performance adapts to both hypo- and hypertension at short time scales and can alter the biomechanics of the vascular wall in vitro.

Adaptation, Biological↗

The influence of collagen fiber orientation and other histocompositional characteristics on the mechanical properties of equine cortical bone.

This study examined relative influences of predominant collagen fiber orientation (CFO), mineralization (% ash), and other microstructural characteristics on the mechanical properties of equine cortical bone. Using strain-mode-specific (S-M-S) testing (compression testing of bone habitually loaded in compression; tension testing of bone habitually loaded in tension), the relative mechanical importance of CFO and other material characteristics were examined in equine third metacarpals (MC3s). This model was chosen since it had a consistent non-uniform strain distribution estimated by finite element analysis (FEA) near mid-diaphysis of a thoroughbred horse, net tension in the dorsal/lateral cortices and net compression in the palmar/medial cortices. Bone specimens from regions habitually loaded in tension or compression were: (1) tested to failure in both axial compression and tension in order to contrast S-M-S vs non-S-M-S behavior, and (2) analyzed for CFO, % ash, porosity, fractional area of secondary osteonal bone, osteon cross-sectional area, and population densities of secondary osteons and osteocyte lacunae. Multivariate multiple regression analyses revealed that in S-M-S compression testing, CFO most strongly influenced total energy (pre-yield elastic energy plus post-yield plastic energy); in S-M-S tension testing CFO most strongly influenced post-yield energy and total energy. CFO was less important in explaining S-M-S elastic modulus, and yield and ultimate stress. Therefore, in S-M-S loading CFO appears to be important in influencing energy absorption, whereas the other characteristics have a more dominant influence in elastic modulus, pre-yield behavior and strength. These data generally support the hypothesis that differentially affecting S-M-S energy absorption may be an important consequence of regional histocompositional heterogeneity in the equine MC3. Data inconsistent with the hypothesis, including the lack of highly longitudinal collagen in the dorsal-lateral ;tension' region, paradoxical histologic organization in some locations, and lack of significantly improved S-M-S properties in some locations, might reflect the absence of a similar habitual strain distribution in all bones. An alternative strain distribution based on in vivo strain measurements, without FEA, on non-Thoroughbreds showing net compression along the dorsal-palmar axis might be more characteristic of the habitual loading of some of the bones that we examined. In turn, some inconsistencies might also reflect the complex torsion/bending loading regime that the MC3 sustains when the animal undergoes a variety of gaits and activities, which may be representative of only a portion of our animals, again reflecting the possibility that not all of the bones examined had similar habitual loading histories.

Animals↗

Impaired carotid and femoral viscoelastic properties and elevated intima-media thickness in peripheral vascular disease.

BACKGROUND: We undertook a study to determine whether peripheral vascular disease of the lower extremity (PVD) per se affects the arterial viscoelastic properties and intima-media thickness (IMT) of the carotid and femoral arteries. METHODS: Thirty-five patients with PVD, 35 age- and gender-matched control subjects were examined with ultrasound scan wall tracking system, with the simultaneous measurement of blood pressure for carotid and femoral IMT and viscoelastic properties. RESULTS: Subjects with PVD have significantly impaired carotid elastic properties including compliance (mean (SD): 6.50 (2.39) vs 9.93 (4.07) %mmHg(-1)x10(-2), P<0.001), Petersen's elastic modulus (1.77 (0.69) vs 1.19 (0.63) mmHg x 10(3), P=0.001) and stiffness index (17.92 (7.21) vs 12.10 (6.17), P=0.001) when compared to non-PVD controls. They also have significantly altered femoral elastic properties including Petersen's elastic modulus (5.94 (4.98) vs 3.64 (3.27) mmHg x 10(3), P=0.025) and stiffness index (58.42 (47.76) vs 36.96 (33.43), P=0.033). The carotid (0.85 (0.35) vs 0.59 (0.23) mm, P<0.001) and femoral (1.05 (0.39) vs 0.69 (0.31) mm, P<0.001) IMTs are also significantly elevated in PVD patients. After adjustment for the presumed cardiovascular load assessed on the basis of a cumulative total vascular risk score, as well as age, systolic and diastolic pressure, the carotid viscoelastic indices and the carotid and femoral IMTs remained highly significant. However, the difference in femoral elastic variables was no longer evident. CONCLUSION: PVD per se affects the femoral and carotid wall mechanics and morphology similarly to other cardiovascular risk factors and events. These parameters may provide further information for cardiovascular risk assessment in addition to the classical risk factors and the Framingham equation. Indeed, some guidelines have suggested that additional factors such as the carotid scan may influence the clinician's decision to intervene with therapy.

Aged↗

[Hypertrophy of the arterial wall and arterial rigidity].

The purpose of this article is to review the relations between hypertension-induced hypertrophy and stiffness of the arterial wall. Arterial remodeling was assessed based on the geometrical (lumen and arterial wall thickness) and functional (distensibility and Young's elastic modulus) properties of large and medium-sized arteries in hypertensive and normotensive subjects. Several clinical and animal studies have shown that arterial wall hypertrophy, which normalizes circumferential wall stress, does not increase the elastic modulus of arterial wall material during chronic essential hypertension. The structural changes associated with hypertension and those associated with aging have opposite effects on arterial distensibility at a given transmural pressure (isobaric distensibility): arterial distensibility increases with hypertension and decreases with aging. Thus, hypertension cannot be considered equivalent to aging. The structural and functional changes in arterial wall material associated with hypertension-induced hypertrophy may explain why medium-sized arteries maintain their distensibility characteristics despite a distending pressure increase; these changes may not be associated with an intrinsic (isobaric) decrease in the distensibility of large arteries.

Animals↗

Immediate and long-term effects of angioplasty-balloon dilation on normal rabbit iliac artery.

The present study was performed to determine the immediate (hours) and long-term (28-day) effects of angioplasty-balloon dilatation on arterial wall diameter, histology, response to vasoconstrictors, and passive mechanics. Dilated left iliac arteries of New Zealand rabbits were compared to control, right iliac arteries. In the immediate studies, dilation increased arteriographic diameter by 32%, denuded the endothelium, stretched and may have lysed smooth muscle cells, decreased arterial wall thickness, and increased passive stress and incremental elastic modulus. The dilated arteries failed to contract to norepinephrine or potassium chloride. In contrast, 28 days after dilation, arteriographic diameter had returned to normal, an intimal thickening had formed, passive stress and the incremental elastic modulus had decreased to below normal, and the arteries contracted, but to only 53% to 67% of control. Angioplasty had no long-term effect on arterial sensitivity (EC50) to potassium chloride or serotonin but did produce a decreased sensitivity (6X) to norepinephrine. These studies demonstrate that the effects of dilatation of the normal artery are partially reversible, suggest that restenosis after angioplasty is more likely to be due to intimal proliferation than increased arterial stiffness, and suggest that vasospasm of arteries after long-term recovery from the dilation is more likely to be mediated by serotonin than by norepinephrine.

Angioplasty, Balloon↗

Manufacture of poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) hydrogel tubes for use as nerve guidance channels.

Hydrogel tubes of poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) (p(HEMA-co-MMA)) made by liquid-liquid centrifugal casting are being investigated as potential nerve guidance channels in the central nervous system. An important criterion for the nerve guidance channel is that its mechanical properties are similar to those of the spinal cord, where it will be implanted. The formulated p(HEMA-co-MMA) tubes are soft and flexible, consisting of a gel-like outer layer, and an interconnected macroporous, inner layer. The relative thickness of the gel phase to macroporous phase is controlled by the formulation chemistry, and specifically by the ratio of co-monomers, HEMA and MMA. By varying the surface chemistry of the mold within which the tubes are synthesized, tubes were prepared with either a "cracked" or a smooth outer morphology. Tubes with the cracked outer morphology had periodic channels that traversed the wall of the tube, which resulted in a lower modulus than smooth outer morphology tubes, yet likely greater diffusive permeability. For tubes (and not rods) to be formed, phase separation must precede gelation as is detailed in a formulation phase diagram for HEMA, MMA and water. The tensile elastic modulus of p(HEMA-co-MMA) tubes reflected the formulation chemistry, with greater moduli (up to 400 kPa) recorded for tubes having 10 wt% MMA. The p(HEMA-co-MMA) tubes therefore had similar mechanical properties to those of the spinal cord, which has a reported elastic modulus range between 200 and 600 kPa.

Biocompatible Materials↗

Effect of smooth muscle activity on the static and dynamic elastic properties of the rabbit carotid artery.

The variation of radius with pressure was measured in vitro in the carotid artery of ten rabbits. Experiments were performed without prior conditioning of the vessel, over an inflation-deflation cycle at pressures in the range 0 to 24 kPa during treatment with, and in the absence of noradrenaline (referred to as active and passive conditions). The effect of a step change in pressure (2.7 kPa) on the radius of the vessel was investigated on a further three specimens. Under passive conditions, the variation of the static and the real part of the dynamic incremental elastic modulus with pressure and stress was similar during both inflation and deflation. Under active conditions a large degree of pressure-radius hysteresis was observed. At physiological pressures smooth muscle activity was associated with a decrease in elastic modulus when compared to passive values at the same pressure or stress. At a stress above 2 x 10(5) N.m-2 yield of the constricted vessels was observed and on further inflation and subsequent deflation the pressure radius curve was identical to that obtained under passive conditions. We suggest that conditioning a vessel, by means of repeated inflation to a high pressure and deflation to zero pressure, before measuring its elastic properties may give misleading results when applied to the vessels of living animals.

Animals↗

Measuring microelastic properties of stratum corneum.

We explore the compression moduli of a thin biological tissue through probe microscopy. The elastic modulus (E') of isolated stratum corneum is measured at varying depths through the use of an atomic force microscope (AFM) as well as a nano-indentor (Hysitron Triboscope). In addition, a nano-DMA is used to measure visco-elastic properties. Measurements on dry and hydrated stratum corneum show an order of magnitude difference in E' and the measured tandelta (E''/E') is seen to increase from approximately 0.1 to 0.25. In addition, extensive validation of the experiments is conducted with different indentation probes at different force ranges to reveal the effects of indentor geometry and indentation depth on the measured elastic modulus. The sensitivity of the measurements is tested with applying known treatments to stratum corneum and exploring their effects on biomechanical parameters.

Animals↗

Strain energy function of red blood cell membranes.

The several widely different values of the elastic modulus of the human red blood cell membrane which have been reported in the literature are incorporated into a single strain energy function consisting of two terms. One term gives the small stresses and low elastic modulus which is observed when the red cell membrane is deformed at constant area. The second term contributes a large isotropic stress dependent on the change of area. The strain energy function is applied to the process of sphering of red blood cells in a hypotonic solution. It is shown that a nearly perfect sphere can result even though the red blood cell membrane is homogeneous in all areas of the cell. Results pertinent to sieving and micropipette experiments are also explored.

Biomechanical Phenomena↗

Prediction of strength of cortical bone in vitro by microcomputed tomography.

OBJECTIVE: The aim of this study was to evaluate the predictive value of bone mineral density and intracortical porosity measured by microcomputed tomography for the strength of cortical bone biopsies. DESIGN: Experimental study comparing the predictive value of bone mineral density and of intracortical porosity determined in vitro by microcomputed tomography for the mechanical properties of cortical bone cylinders. BACKGROUND: The assessment of cortical bone strength might be relevant for the prediction of fracture risk or the choice of suitable therapy strategies in orthopaedic surgery. The predictive value of cortical density for the mechanical properties is discussed controversially. The relevance of intracortical porosity measured by histomorphometry has been established, but the predictive value of porosity determined by microcomputed tomography remains to be explored. METHODS: Femoral cortical bone specimens from the mid diaphysis of 24 patients were harvested during total hip replacement procedure at the location, where a diaphyseal hole (diameter 4.5 mm) was drilled in order to reduce the intramedullary pressure. In vitro intracortical porosity and bone mineral density measurements by microcomputed tomography were compared with strength and elastic modulus assessed by a compression test transverse to the Haversian systems of the same specimens. RESULTS: Significant negative correlations were found between porosity measured by microcomputed tomography scans and yield stress, stiffness and elastic modulus (P<0.001), however, the positive correlations between bone mineral density and mechanical parameters were stronger (P<0.0001). The mechanical parameter best predicted by mineral density as well as by porosity was yield stress (r=0.72,P<0.0001;r=-0.64,P<0.001). CONCLUSIONS: Bone mineral density determined by microcomputed tomography imaging in vitro may be a potent method to predict mechanical properties of cortical bone non-destructively. The application in vivo remains to be explored.

Aged↗

Water plasticization of extruded material made from meat and bone meal and sodium caseinate.

Meat and bone meal (MBM) is a high protein agricultural commodity that currently has few applications other than as an animal feed. Unmodified MBM has poor functional properties, due to its low solubility. Our results from pilot plant trials demonstrate that MBM can be extrusion-processed along with sodium caseinate to produce a useful plastic material. We developed this material for use as a dog chew toy. For this application, elastic modulus (stiffness) is a key characteristic. Our results detail the relationship between ambient relative humidity and equilibrium moisture content (MC) in the material. The influence of MC on the glass transition temperature and elastic modulus reflects the plasticization of this material by water. On the basis of a comparison to a commercially available dog chew, the range of stiffness achievable with our material, 0.25-2.50 GPa, encompasses the values appropriate for a dog chew. Our results show that a particular desired stiffness can be maintained by applying an edible moisture barrier to the surface of the material.

Animal Feed↗

Adsorption control of synovia constituents on artificial joint materials by means of an electric field: evaluation of tribological characteristics.

The supplemental lubrication mechanism by means of an electric field was proposed to reduce friction and wear for the advanced joint prosthesis with the low elastic modulus bearing surface. The possibility of application of this mechanism to the prosthesis was investigated by the fundamental and experimental procedures in simplified sliding conditions. Conductive silicon rubber was used as the low elastic modulus surface. The counterfaces were a titanium alloy and a stainless steel. Protein (gamma-globulin) in lubricant appeared to cause the tribological characteristic to deteriorate in the mixed lubrication regime. High friction seemed to be brought about by the obstruction against the entraining of the fluid flow and the high shear stress due to the microbonding between the asperities of bearing surfaces, which were derived from the adsorbed protein on the hydrophobic surfaces. The repulsive force between the adsorbed film and the bearing materials by means of the d.c. electric field, and the continuous change in polarity on the surface by means of the a.c. electric field appeared to affect the adsorbed film adjacent to the bearing material, so that friction and wear were varied.

Adsorption↗

Magnetic resonance imaging provides evidence for remodeling of the right ventricle after single-lung transplantation for pulmonary hypertension.

BACKGROUND: In end-stage pulmonary hypertension (PH), the degree of right ventricular (RV) dysfunction has been considered so severe as to require combined heart-lung transplantation. Nevertheless, left ventricular (LV) and RV hemodynamics return to relatively normal levels after single-lung transplantation (SLT) alone. Accordingly, to test the hypothesis that LV and RV systolic function improves after SLT and that the dilated, thick-walled RV reverts to more normal geometry, we used cine MRI and finite-element (FE) analysis to study patients with end-stage PH. METHODS AND RESULTS: Seven patients with end-stage PH underwent cine MRI before and after SLT, and eight normal volunteers were also imaged with cine MRI. Short-axis images at the midventricular level were analyzed with customized image-processing software. The LV and RV ejection fractions, velocity of fiber shortening, RV end-diastolic (ED) and end-systolic (ES) chamber areas, and RV ES and ED wall thicknesses were calculated directly from the MRI images. Two-dimensional FE models of the heart were constructed from the MRI images at early diastole. LV and RV pressures were measured in the patients with a cardiac catheterization before and after SLT. Models were solved to yield diastolic LV, RV, and septal wall stresses. By use of a nonlinear optimization algorithm, LV and RV diastolic maternal properties were determined by minimization of the leastsquares difference between FE model-predicted and MRI-measured LV, RV, and epicardial chamber areas and circumferences. The results demonstrated a substantial reduction in RV wall stress after SLT (1.8 x 10(5) dynes/cm2 pre-SLT to 2 x 10(4) dynes/cm2 post-SLT; P < .001). The average RV diastolic elastic modulus was reduced significantly after SLT (1.5 x 10(6) dynes/cm2 pre-SLT to 1 x 10(5) dynes/cm2 post-SLT; P = .01), but there was no change in the LV elastic modulus. RV velocity of fractional shortening increased significantly after SLT (0.23 pre-SLT to 0.58 post-SLT, P = .02), and RV ED and ES wall thicknesses were reduced significantly (ED, 0.86 cm pre-SLT to 0.65 cm post-SLT, P = .03 and ES, 1.06 cm pre-SLT to 0.72 cm post-SLT, P = .005). CONCLUSIONS: These results provide evidence supporting the contention that LV and RV systolic function improved after SLT for end-stage PH and that the RV underwent significant remodeling within 3 to 6 months after lung transplantation.

Adolescent↗

The effect of elastic stockings on the elasticity of varicose veins.

The aim of this study was to establish the long-term effect of graduated elastic compression on venous elasticity in patients with superficial or deep venous disease and to determine the possible relationship between elasticity and the duration of the disease. The elastic modulus of 29 patients, 19 with superficial vein incompetence and 10 with deep vein incompetence was assessed by the simultaneous measurement of calf volume (determined using strain gauge) and venous pressure (obtained via a dorsal foot vein) during venous occlusion. The measurements were obtained before and after 4 weeks of elastic compression stockings. The elastic modulus K, was defined as stress/strain when the veins were full and was calculated from the pressure/volume relationship. The results show a clear difference in elasticity before and after elastic stockings. Two groups of patients were identified: group 1 with increased elasticity and group 2 with decreased elasticity. There was a negative linear relationship (r = 0.88) between increase in elasticity after treatment and duration of venous disease.

Bandages↗

Effect of intraluminal thrombus on abdominal aortic aneurysm wall stress.

PURPOSE: Abdominal aortic aneurysms (AAAs) rupture when the wall stress exceeds the strength of the vascular tissue. Intraluminal thrombus may absorb tension and reduce AAA wall stress. This study was performed to test the hypothesis that intraluminal thrombus can significantly reduce AAA wall stress. METHODS: AAA wall stresses were determined by axisymmetric finite element analysis. Model AAAs had external diameters ranging from 2.0 to 4.0 cm. Model parameters included: AAA length, 6 cm; wall thickness, 1.5 mm; Poisson's ratio, 0.49; Young's modulus, 1.0 MPa; and luminal pressure, 1.6 x 10(5) dyne/cm2. Stresses were calculated for each model without thrombus, and then were recalculated with thrombus filling 10% of the AAA cavity. Calculations were repeated as thrombus size was increased in 10% increments and as thrombus elastic modulus increased from 0.01 MPa to 1.0 MPa. Maximum wall stresses were compared between models that had intraluminal thrombus and the unmodified models. Stress reduction greater than 25% was considered significant. RESULTS: The maximum stress reduction of 51% occurred when thrombus with elastic modulus of 1.0 MPa filled the entire AAA cavity. Stresses were reduced by only 25% as modulus decreased to 0.2 MPa. Similarly, decreasing thrombus size by 70% resulted in stress reduction of only 28%. Large AAAs experienced greater stress reduction than small AAAs (48% vs 11%). CONCLUSION: Intraluminal thrombus can significantly reduce AAA wall stress.

Aorta, Abdominal↗

The influence of the bone-implant interface stiffness on stress profiles surrounding Al2O3 and carbon dental implants.

Dental implants have been used and studied for the replacement of missing teeth for many years. Finite element stress analysis (FESA) has previously been used in their evaluation to study the effect of various design parameters on induced stresses. A two-dimensional FESA was used to evaluate the effect that the implant-bone interface elastic modulus has on the stress distribution around LTI carbon and aluminum oxide dental implants. The results of this investigation indicate that a soft tissue interface between implants and bone negates the effect of implant elastic modulus and results in stress profiles that were almost identical for the LTI carbon and aluminum oxide implants.

Aluminum↗