PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38Linked to original sources

Analytical strategies for amperometric biosensors based on chemically modified electrodes.

Various strategies based on the use of chemically modified electrodes for the development of amperometric biosensors are described. Particular emphasis is placed on materials capable of catalyzing the oxidation of NADH and coupling these with enzymatic activities for biosensor construction. In terms of electrocatalysts, the discussion will centre on electrodeposited films of 3,4-dihydroxy benzaldehyde (3,4-DHB) and related analogs as well as on electrodeposited films of transition metal complexes of 1,10-phenanthroline-5,6-dione (phen-dione). Electrodeposited films of these materials have been coupled to the enzymatic activity of aldehyde dehydrogenase and alcohol dehydrogenase for the development of biosensors for aldehydes and ethanol, respectively.

Alcohol Dehydrogenase↗

Free cholesterol fiber-optic biosensor for serum samples with simplex optimization.

An optical fiber biosensor for free cholesterol monitoring in serum samples is described. Silicone-entrapped tris(4,7-diphenyl-1,10-phenanthroline) ruthenium(II) complex, the luminescence of which is sensitive to oxygen changes, is used as an optical transducer of the oxidation of cholesterol by cholesterol oxidase. The biocatalyst is entrapped in a graphite powder layer deposited onto the dyed silicone film. Optimization of some interdependent chemical variables which affect the performance of the biosensor has been achieved by application of a super-modified simplex method. The dynamic range of the biosensing membranes is found to be 0.15-3.0 mM of free cholesterol. Studies of the reproducibility, stability and interferences of the device, as well as the application of the sensor to measurements in serum samples, are reported. Simplex optimization has proven to be a very useful tool in the search for the optimal conditions for performing analyses with the optical fiber biosensor.

Biosensing Techniques↗

Electrochemical biosensors for DNA hybridization and DNA damage.

Recent trends in the development of DNA biosensors for nucleotide sequence-specific DNA hybridization and for the detection of the DNA damage are briefly reviewed. Changes in the redox signals of base residues in DNA immobilized at the surface of carbon or mercury electrodes can be used as a sign of the damage of DNA bases. Some compounds interacting with DNA can produce their own redox signals on binding to DNA. Covalently closed circular (usually supercoiled) DNA attached to the electrode surface can be used for a sensitive detection of a single break of the DNA sugar-phosphate backbone and for detection of agents cleaving the DNA backbone such as hydroxyl radicals, ionizing radiation, nucleases, etc. Using the peptide nucleic acid in the biosensor recognition layer greatly increased the specificity of the DNA hybridization biosensor making it possible to detect point mutations (single-base mismatches) in DNA.

Animals↗

Effects of high oxygen concentrations on microbial biosensor signals. Hyperoxygenation by means of perfluorodecalin.

Amperometric biosensors register oxygen depletion in response to analyte catabolism, and thus are limited by the availability of dissolved oxygen. Microbial sensors containing immobilized cells of Gluconobacter oxydans were hyperoxygenated to 400% of control levels and the effects on sensor responses to glucose were determined. Oxygenated perfluorodecalin (a completely fluorinated organic substance) was as effective in hyperoxygenation as direct sparging with O2, increasing sensor base medium oxygen concentrations from 9.3 to 37 mg/l. Hyperoxygenation enhanced maximal biosensor response amplitudes, particularly at high cell loading densities. Maximal response rates were also improved, although less dramatically. Results suggest that hyperoxygenation may be a new general approach for modulating biosensor responses.

Acetobacteraceae↗

An optical biosensor for real-time chromatography monitoring: breakthrough determination.

The use of an optical biosensor for immunorecognition of protein products during affinity chromatography is discussed to provide rapid data describing the loading and subsequent breakthrough, followed by elution and fraction collection. The optical biosensor works by following in real-time the interaction of soluble ligate with an appropriate ligand attached to the optically active surface. The initial rate of interaction between soluble ligate and immobilized ligand has been shown to correlate well with ligate concentration. This method of analysis has also been shown to agree well with ELISA, the traditionally employed technique for immunoassay of protein products lacking, for example, catalytic activity. Forward prediction, using models of the breakthrough fitted to the real-time data, has enabled the column saturation point to be determined before it has been reached, thus enabling appropriate action to ensure minimal loss of protein product while improving column utilization efficiency. The biosensor, operated within a flow injection analysis regime, has been demonstrated to provide concentration data within 10 s, with a total assay turnaround of 30 s.

Animals↗

A disposable biosensor for urea determination in blood based on an ammonium-sensitive transducer.

A potentiometric urea-sensitive biosensor using a NH4(+)-sensitive disposable electrode in double matrix membrane (DMM) technology as transducer is described. The ion-sensitive polymer matrix membrane was formed in the presence of an additional electrochemical inert filter paper matrix to improve the reproducibility in sensor production. The electrodes were prepared from one-side silver-coated filter paper, which is encapsulated for insulation by a heat-sealing film. A defined volume of the NH4(+)-sensitive polymer matrix membrane cocktail was deposited on this filter paper. To obtain the urea-biosensor a layer of urease was cast onto the ion-sensitive membrane. Poly (carbamoylsulfonate) hydrogel, produced from a hydrophilic polyurethane prepolymer blocked with bisulfite, served as immobilisation material. The disposable urea sensitive electrode was combined with a disposable Ag/AgCl reference electrode to obtain the disposable urea biosensor. The sensor responded rapidly and in a stable manner to changes in urea concentrations between 7.2 x 10(-5) and 2.1 x 10(-2)mol/l. The detection limit was 2 x 10(-5) mol/l urea and the slope in the linear range 52 mV/decade. By taking into consideration the influence of the interfering K(+)- and Na(+)-ions the sensor can be used for the determination of urea in human blood and serum samples (diluted or undiluted). A good correlation was found with the data obtained by the spectrophotometric routine method.

Biosensing Techniques↗

A single- and a dual-fractal analysis of antigen-antibody binding kinetics for different biosensor applications.

The diffusion-limited binding kinetics of antigen (or antibody) in solution to antibody (or antigen) immobilized on a biosensor surface is analyzed within a fractal framework. The data is adequately described by a single- or a dual-fractal analysis. Initially, the data was modelled by a single-fractal analysis. If an inadequate fit was obtained then a dual-fractal analysis was utilized. The regression analysis provided by Sigmaplot, 1993 (Scientific Graphing Software: User's Manual. Jandel Scientific, San Rafael, CA) was utilized to determine if a single-fractal analysis is sufficient, or a dual-fractal analysis is required. In general, it is of interest to note that the binding rate coefficient and the fractal dimension exhibit changes in the same direction (except for a single example) for the antigen-antibody systems analyzed. Binding rate coefficient expressions as a function of the fractal dimension developed for the antigen-antibody binding systems indicate a high sensitivity of the binding rate coefficient on the fractal dimension when both a single -as well as a dual-fractal analysis is used. For example, for a single-fractal analysis and for the binding of human endothelin-1 (ET-1) antibody in solution to ET-1(15-21) x BSA (bovine serum albumin) immobilised on a surface plasmon resonance surface, the order of dependence of the binding rate coefficient, k on the fractal dimension, Df is 7.0945. Similarly, for a dual-fractal analysis and for the binding of parasite L. donovani diluted pooled sera in solution to fluorescein isothiocyanate-labeled anti-human immunoglobulin IgG immobilized on an optical fibre, the order of dependence of k1 and k2 on Df1 and Df2 were 6.8018 and -4.393, respectively. Binding rate coefficient expressions are also developed as a function of the analyte (antigen or antibody) concentration in solution. The binding rate coefficient expressions developed as a function of the fractal dimension(s) are of particular value since they provide a means to better control biosensor performance by linking it to the heterogeneity on the surface, and emphasize in a quantitative sense the importance of the nature of the surface in biosensor performance.

Animals↗

Determination of organophosphate and carbamate pesticides in spiked samples of tap water and fruit juices by a biosensor with photothermal detection.

The determination of organophosphate (paraoxon, chlorpyrifos, diazinon) and carbamate (carbaryl, carbofuran) pesticides in spiked drinking water and fruit juices was carried out using a photothermal biosensor. The biosensor consists of a cartridge containing immobilised enzyme acetylcholinesterase (AChE) placed in a flow-injection analysis (FIA) manifold and a photothermal detector based on thermal lens spectrometry. With this approach, 0.2 ng/ml of paraoxon can be detected in less than 15 min. Limits of detection for other organophosphate (chlorpyrifos, diazinon) and carbamate (carbaryl, carbofuran) pesticides varied, depending on their antiacetylcholinesterase (AntiAChE) toxicity, from 1 ng/ml to 4 microg/ml. The biosensor was used for the direct detection of pesticides in spiked tap water and fruit juices without any pretreatment steps. In these cases, the LOD3sigma of 1.5, 2.8 and 4 ng/ml paraoxon in tap water, orange juice and apple juice were obtained, respectively.

Beverages↗

A glucose biosensor operating under non-isothermal conditions: the dynamic response.

The results obtained with a glucose biosensor operating under non-isothermal conditions are presented and discussed. Glucose oxidase, immobilized onto Nylon membranes, was used as biological element. An amperometric two electrodes system was employed to measure the anodic current produced by oxidation of hydrogen peroxide. Non-isothermal conditions were characterised in terms of the temperature difference, delta T = Tw - Tc, and of the average temperature of the system, Tav = (Tw + Tc)/2, Tw and Tc being the temperature in the warm and cold half-cells constituting the biosensor. Comparison between the functioning of the biosensor under isothermal and non-isothermal conditions was performed. It was found that, under non-isothermal conditions, the dynamic response and sensitivity increased, while the response times and the detection limit decreased, if comparison was done with the same parameters measured under isothermal conditions. The increase of the dynamic response was found to be proportional to the applied temperature gradient.

Biosensing Techniques↗

Sensitive amperometric biosensor for the determination of biogenic and synthetic amines using pea seedlings amine oxidase: a novel approach for enzyme immobilisation.

We prepared a new inorganic sorbent based on modified triazine (2-[4,6-bis (aminoethylamine)-1,3,5-triazine]-Silasorb; BAT-Silasorb) which binds pea seedlings amine oxidase (PSAO) very tightly without loss of its catalytic activity. This unique feature as well as the wide substrate specificity of PSAO was successfully utilised in the construction of an amperometric biosensor based on a carbon paste electrode for the fast and sensitive detection of various amines at a formal potential 0 mV versus Ag/AgCl reference electrode. The reaction layer of the biosensor is created by the direct immobilisation of PSAO at the electrode surface via affinity carrier BAT-Silasorb. Used arrangement facilitates a simple restoration of the inactive biosensor. An amperometric signal results from horseradish peroxidase catalysed reduction of H2O2, a secondary product of the oxidative deamination of amines, catalysed by PSAO. The sensor was used for the basic characterisation of 55 biogenic and synthetic amines, from numerous mono-, di- and polyamines to various hydroxy-, thio-, benzyl- and aromatic derivatives in order to establish its suitability as a postcolumn detector. Its high sensitivity to putrescine 20.0 +/- 0.64 mA l-1 per mol (636.9 +/- 2.03 mA l-1 per mol per cm2), a limit of detection of 10 nmol l-1 (determined with respect to a signal-to-noise ratio 3:1), a linear range of current response to 0.01-100 mumol l-1 concentration of substrate and good reproducibility all indicate that the sensor could be applied to future industrial and clinical analyses.

Amine Oxidase (Copper-Containing)↗

The development of immunoassays to four biological threat agents in a bidiffractive grating biosensor.

A critical need exists for a field deployable biosensor to detect environmental infectious agents in collected air samples rapidly, with sensitivity and specificity approaching that of standard laboratory procedures. The ideal sensor would analyze unknown samples in minutes, have programmable operation for unattended sample analysis, and be capable of multiple agent analysis for a number of agents. The goal of this project was to further the development of the bidiffractive grating biosensor (BDG) created through collaboration between Battelle Memorial Institute (BMI), Hoffman LaRoche (HLR), and the Naval Medical Research Command (NMRC). This manuscript details the development, optimization, and evaluation of this device as a potential field deployable biosensor. Well-characterized immunochemical reagents developed by the Biological Defense Research Department (BDRD) at NMRI were employed to develop assays in the BDG. These results were compared to those obtained with antigen capture enzyme linked immunosorbent assays (ELISAs). Four separate antigens were evaluated: Staphylococcus aureus enterotoxin B (SEB), ricin (RIC), Francisella tularensis (FT), and Clostridium botulinum toxin (BOT).

Biological Warfare↗

Estrogen receptor binding assay of chemicals with a surface plasmon resonance biosensor.

We have developed a simple assay method for the evaluation of estrogen receptor (ER) binding capacity of chemicals without the use of radio- or fluorescence-labeled compounds. We used the solution competition assay by the BIACORE biosensor, a surface plasmon resonance biosensor, with estradiol as a ligand, human recombinant ER(alpha) (hrER(alpha)) as a high molecular weight (hmw) interactant and test chemicals as analytes. For the ligand, aminated estradiol with a spacer molecule (E2-17PeNH) was synthesized and immobilized on a carboxymethyl dextran-coated sensor chip by the amine coupling method. The injection of the hmw interactant hrER(alpha) to the biosensor raised the sensorgram, indicating its binding to the ligand E2-17PeNH. The binding of test chemicals to hrERalpha was determined as a reduction in the hrER(alpha) binding to E2-17PeNH. The dissociation constant for the binding to hrER(alpha) was calculated for estrone (4.29 x 10(-9)M), estradiol (4.04 x 10(-10)M), estriol (8.35 x 10(-10)M), tamoxifen (2.16 x 10(-8)M), diethylstilbestrol (1.46 x 10(-10)M), bisphenol A (1.35 x 10(-6)M) and 4-nonylphenol (7.49 x 10(-6)M), by plotting the data according to an equation based on mass action law. This method can also be used as a high throughput screening method.

Biosensing Techniques↗

Biosensor development.

Current biosensor developments can be summarised by different trends. For traditional enzymatic biosensors such as glucose sensors, steady improvements of well known basic principles have been made in order to achieve better sensor stability. On the other hand, new affinity sensors such as nucleic acid sensors, transmembrane sensors, and sensors utilising whole cells or even cell networks have become of increasing interest. New ways to miniaturise biosensors and to control their interfaces down to the molecular level have been introduced (the bioelectronics approach). High-throughput screening based on various signal transduction principles has become of increasing importance.

Antigen-Antibody Reactions↗

Amperometric enzyme biosensors based on optimised electron-transfer pathways and non-manual immobilisation procedures.

Development of reagentless biosensors implies the tight and functional immobilisation of biological recognition elements on transducer surfaces. Specifically, in the case of amperometric enzyme electrodes, electron-transfer pathways between the immobilised redox protein and the electrode surface have to be established allowing a fast electron transfer concomitantly avoiding free-diffusing redox species. Based on the specific nature of different redox proteins and non-manual immobilisation procedures possible biosensor designs are discussed, namely biosensors based on (i) direct electron transfer between redox proteins and electrodes modified with self-assembled monolayers; (ii) anisotropic orientation of redox proteins at monolayer-modified electrodes; (iii) electron-transfer cascades via redox hydrogels; and (iv) electron-transfer via conducting polymers.

Biosensing Techniques↗

Impedimetric biosensors.

Electrochemical impedance spectroscopy (EIS) is a sensitive indicator of a wide variety of chemical and physical properties. An increasing trend towards the development of impedimetric biosensors is being currently observed. Impedimetric techniques have been performed to characterize the fabrication of the biosensors and to monitor the catalyzed reactions of enzymes or the biomolecular recognition events of specific binding proteins, lectins, receptors, nucleic acids, whole cells, antibodies or antibody-related substances. However, little attention has been paid to reviewing this interesting research area. Herein, impedimetric biosensors are reviewed and many novel designs are discussed.

Journal Article↗

Implementing surface plasmon resonance biosensors in drug discovery.

Recent improvements in instrument hardware, experimental design and data processing have made it possible to use surface plasmon resonance (SPR) biosensor technology in the discovery and development of small-molecule drugs. The key features of SPR biosensors (i.e. real-time binding analysis and lack of labeling requirements) make this technology suitable for a wide range of applications. Current instruments have a throughput of approximately 100-400 assays per day, providing a complement to secondary screening. The ability to collect kinetic data on compounds binding to therapeutic targets yields new information for lead optimization. Small-molecule analysis and emerging applications in the areas of ADME (adsorption, distribution, metabolism and excretion) and proteomics have SPR biosensors poised to play a significant role in the pharmaceutical industry.

Journal Article↗

A novel enzyme biosensor for steroidal glycoalkaloids detection based on pH-sensitive field effect transistors.

For the design of a biosensor sensitive to steroidal glycoalkaloids, pH-Sensitive Field Effect Transistors as transducers and immobilised butyrylcholinesterase as a biorecognition element have been used. The total potato glycoalcaloids can be measured by this biosensor in the concentration range 0.5-100 microM with detection limits of 0.5 microM for alpha-chaconine and of 2.0 microM for alpha-solanine and solanidine, respectively. The responses of the developed biosensors were reproducible with a relative standard deviation of about 1.5% and 5% for intra- and inter-sensor responses (both cases, n=10, for an alkaloid concentration of 5 microM), respectively. Moreover, due to the reversibility of the enzyme inhibition, the same sensor chip with immobilised butyrylcholinesterase can be used several times (for at least 100 measurements) after a simple washing by a buffer solution and can be stored at 4 degrees C for at least 3 months without any significant loss of the enzymatic activity.

Alkaloids↗

Evaluation of redox mediators for amperometric biosensors: Ru-complex modified carbon-paste/enzyme electrodes.

The properties of reagentless amperometric biosensors are mainly governed by the interaction of the used redox enzyme and the redox mediators used to facilitate the electron-transfer reaction. Both the used redox mediators and the redox enzymes differ concerning their hydrophilicity and their properties within the matrix of a carbon-paste electrode. Since there is no general procedure which is applicable for any enzyme in combination with any redox mediator, optimisation is necessary for each possible combination. Three approaches for the development of biosensors were investigated using carbon-paste electrodes enriched with redox mediator as a base in all sensor architectures. A class of redox mediators with the common formula Ru(LL)(2)(X)(2) (where LL are 1,10-phenantroline or 2,2'-bipyridine type ligands, and X is an acido ligand) was investigated. In the first approach, enzymes were integrated into the carbon paste; in the second, the enzymes were adsorbed on the surface of the mediator-containing carbon-paste electrode and held in place by a Nafion film; and in the third approach, enzymes were entrapped in polymer films, which were electrochemically deposited onto the electrode's surface. The properties of the obtained biosensors strongly depend on the sensor architecture and the specific features of the used enzyme. Thus, our investigation using three different sensor architectures can provide valuable information about the possible interaction between a specific enzyme and a redox mediators with specific properties.

Alcohol Dehydrogenase↗