PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “COMPRESSION”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

Effects of the mechanical energy of multi-tableting compression on the polymorphic transformations of chlorpropamide.

The effects of the mechanical energy of tableting compression on the polymorphic transformation of chlorpropamide have been examined. A single-punch eccentric tableting machine with a load cell and a non-contact displacement transducer were used to measure compression stress, distance and energy. An amount of 100 mg of the stable form A or the meta-stable form C of the drug was loaded into the press and the sample compressed with a compression stress of 196 MPa at room temperature (20 degrees C). The compression cycle was repeated from 1 to 30 times. The powder X-ray diffraction profiles of the deagglomerated compressed sample powder were measured to calculate the polymorphic content. The results on forms A and C suggested that both forms were transformed into each other in the solid state by mechanical energy during tableting. The contents of forms A and C reached equilibrium at a constant value above 100 J g-1 of compression energy after more than 10 cycles. After 30 tableting cycles of forms A and C, the contents of A, C and the non-crystalline solid were almost constant at about 45, 25 and 30%, respectively. The compression energies were estimated to be about 500-600 J g-1. From the results it seems that the transformation mechanism of forms A and C during tableting were as follows. The crystal form of A or C was converted to a non-crystalline solid by the mechanical energy, and the solid was then transformed into form A or C.

Chemical Phenomena↗

Effects of temperature and pressure during compression on polymorphic transformation and crushing strength of chlorpropamide tablets.

The effects of temperature on the polymorphic transformation of chlorpropamide during compression and on the physical properties of the tablet have been investigated. A heater and liquid nitrogen pool were mounted on the die of a single punch eccentric tableting machine, and the die temperature was controlled by a thermocontroller. A tableting machine with two load cells (upper and lower punches) and a non-contact displacement transducer were used to measure compression stress, distance and energy. The X-ray diffraction profiles of the deagglomerated compressed sample powder were measured to calculate the polymorphic content. The amount of form C transformed from form A at 45 degrees C was about twice that at 0 degree C with the same compression energy. The amount of form A transformed from form C by compression at 45 degrees C was almost the same as that at 0 degree C. This suggests that the mechanochemical effect of form A depended on the compression temperature, but that of form C was independent of temperature. The crushing strength of tablets of form A was about twice that of form C, even at the same porosity. The plots of log (crushing strength of tablet) against porosity of form A tablets compressed at 0 and 45 degrees C were linear with the same slope; the slope for form C tablets compressed at 45 degrees C was less than that at 0 degree C.

Chemistry, Pharmaceutical↗

Effects of varying patterns of external compression on lymph flow in the hindlimb of the anaesthetized sheep.

1. Lymphatics draining the region distal to the fetlock were cannulated in anaesthetized sheep. A pneumatic cuff was used to intermittently compress the drainage area. 2. Intermittent inflation of the cuff accelerated lymph flow. This effect increased dramatically as the frequency of inflation was increased. 3. With a constant inflation time, increasing the time between inflations increased the additional volume of lymph expelled per external compression threefold over the range of 0.5-8 s. Longer intervals produced little further change. 4. There was no significant difference between the effects on lymph volume per compression of intermittent cuff inflations lasting from 1 to 18 s with a constant time between inflations. 5. A cuff pressure of 20 mmHg produced a significant rise in lymph flow. Increasing the pressure applied during cuff inflation increased the effect up to the maximum pressure used (320 mmHg). 6. These studies demonstrate that the promotion of lymph formation by tissue compression is related to the number of compressions applied and the period of time between them. Increasing the pressure exaggerates the effect but increasing the length of each compression does not. This suggests that compression empties the terminal lymphatics centripetally. These vessels refill after compression is released and in our preparation this is complete in about 8 s.

Animals↗

Bioengineering studies of periodic external compression as prophylaxis against deep vein thrombosis-part II: experimental studies on a stimulated leg.

In this companion paper to "Part I: Numerical Simulations, " we report in vitro experimental studies performed on a simple model leg consisting of a "vein" of thin-walled latex tubing surrounded by "tissue" of open-pore foam rubber. Three modes of periodic external compression, were investigated: i) uniform compression; (ii) graded compression, decreasing from ankle to knee; and (iii) sequential compression, progressing from ankle to knee. The modes are compared on the basis of three hemodynamic criteria: degree of vessel collapse, level of fluid velocity, and level of shear stress. In uniform compression these measures of merit are distributed very nonuniformly along the length of the leg: they are high near the proximal end of the cuff but low elsewhere, a result due to the formation proximally of a partially occlusive throat. The latter does not form in either graded or sequential compression, with the consequence that favorable values of the three measures of merit occur more uniformly along the length of the pressurized region. It is concluded that either the graded or sequential mode of compression, or perhaps a combination of the two, would be more effective than uniform compression as a prophylaxis against deep vein thrombosis.

Gravity Suits↗

A method for splitting digital value in radiological image compression.

A new decomposition method using image splitting and gray-level remapping has been proposed for image compression, particularly for images with high contrast resolution. The effects of this method are especially evident in this radiological image compression study. In these experiments, the impact of this decomposition method was tested on image compression by employing it with two coding techniques on a set of clinically used CT images and several laser film digitized chest radiographs. One of the compression techniques used as zonal full-frame bit-allocation in the discrete cosine transform (DCT) domain, which is an enhanced full-frame DCT technique that has been proven to be an effective technique for radiological image compression. The other compression technique used was vector quantization with pruned tree-structured encoding, which through recent research has also been found to produce a low mean-square error and a high compression ratio. The parameters used in this study were mean-square error and the bit rate required for the compressed file. In addition to these parameters, the differences between the original and reconstructed images were presented so that the specific artifacts generated by both techniques could be discerned through visual perception.

Brain↗

Contrast-detail analysis of image degradation due to lossy compression.

A contrast-detail (CD) experiment was performed to study the effect of lossy compression on computed radiographic (CR) images. Digital CR images of a phantom were compressed by quantizing the full-frame discrete cosine transform and Huffman encoding the result. Since low-contrast detectability is directly linked to an important radiological task, namely, the detection of noncalcified pulmonary nodules in adult chest radiographs, the goal of the study was to quantify any loss in low-contrast detectability due to compression. Compression ratios varied significantly among compressed images, despite the use of fixed compression parameters; detectability could be specified by a single parameter of a CD curve; there was no significant reduction in detectability for an average compression ratio of 11:1; and, there was a statistically significant degradation in detectability for an average compression ratio of 125:1.

Humans↗

Medical image compression based on a morphological representation of wavelet coefficients.

Image compression is fundamental to the efficient and cost-effective use of digital medical imaging technology and applications. Wavelet transform techniques currently provide the most promising approach to high-quality image compression which is essential for diagnostic medical applications. A novel approach to image compression based on the wavelet decomposition has been developed which utilizes the shape or morphology of wavelet transform coefficients in the wavelet domain to isolate and retain significant coefficients corresponding to image structure and features. The remaining coefficients are further compressed using a combination of run-length and Huffman coding. The technique has been implemented and applied to full 16 bit medical image data for a range of compression ratios. Objective peak signal-to-noise ratio performance of the compression technique was analyzed. Results indicate that good reconstructed image quality can be achieved at compression ratios of up to 15:1 for the image types studied. This technique represents an effective approach to the compression of diagnostic medical images and is worthy of further, more thorough, evaluation of diagnostic quality and accuracy in a clinical setting.

Algorithms↗

Intraocular pressure changes after peribulbar injections with and without ocular compression.

AIM: Two prospective studies were carried out in order to investigate (1) the rise in intraocular pressure (IOP) following peribulbar anaesthesia with a fixed volume of anaesthetic agent administered by a single surgeon, and (2) the efficacy of ocular compression with the Honan balloon for lowering IOP. Glaucomatous eyes were excluded from both studies. METHODS: In study group 1, 36 eyes of 36 patients undergoing cataract and/or implant surgery each received peribulbar injections consisting of 5 ml of anaesthetic from an inferotemporal site through the conjunctiva and a further 5 ml from a medial injection through the caruncle. IOP values were measured immediately before and after the injections and then after a variable period of external ocular compression. In study group 2, 20 eyes of 20 patients undergoing cataract surgery received peribulbar injections of local anaesthetic as above. IOP values were measured immediately before and after the injections and after 20 minutes without ocular compression. After a further 20 minute period with ocular compression the IOP was again measured. RESULTS: In study group 1, the mean immediate rise in IOP induced by the injections was 11.44 (95% confidence interval 8.97-13.90) mm Hg. The mean change in IOP after ocular compression was an overall fall of 2.42 (0.49-4.34) mm Hg from the pre-injection value. In study group 2, the mean injection induced rise in IOP was 9.45 (6.90-12.00) mm Hg. The mean fall in IOP during the first 20 minutes without ocular compression was 2.85 (1.20-4.50) mm Hg. During the second 20 minutes with ocular compression the mean fall in intraocular pressure was 11.05 (8.14-14.96) mm Hg. CONCLUSIONS: There is a large and individually variable rise in IOP following peribulbar anaesthesia. Ocular compression with the Honan balloon is effective in reversing this rise even when the initial rise is large.

Anesthesia, Local↗

Effect of digital image compression on screening for diabetic retinopathy.

BACKGROUND/AIMS: Digital imaging is widely used for diabetic retinopathy screening. The storage and transmission of digital images can be facilitated by image compression. The authors aimed to assess the effect of image compression on the accuracy of grading diabetic retinopathy. METHODS: Forty nine 35 mm transparencies (17 with no retinopathy, eight with background, five with preproliferative, and 19 with proliferative retinopathy) were digitised and subjected to JPEG compression by 90%, 80%, 70%, and 0%. The 196 images were randomised and graded on a portable computer. Two masked graders assessed the images for grade of retinopathy and image quality (0-10). The sensitivity and specificity of retinopathy grading were calculated with a weighted kappa for grading agreement between levels of compression. RESULTS: The sensitivity of retinopathy grading was reduced by JPEG compression. At 90%, 80%, 70%, and 0% compression the sensitivities were 0.38, 0.50, 0.65, and 0.72, respectively; the specificity results were 1.00, 1.00, 0.83, and 0.84, respectively; and the weighted kappa scores were 0.60, 0.75, 0.77, and 0.84, respectively. The quality scores for 90%, 80%, 70%, 0% compression were 2.9 (SD 1.1, 95% CI; 2.7-3.2), 4.6 (SD 1.1, 95% CI; 3.0-5.6), 5.8 (SD1.5, 95% CI 5.0-6.6), 6.3 (SD1.4, 95% CI; 5.4-7.2) (p<0.01 for each intergroup comparison). CONCLUSION: The results demonstrate significant loss of sensitivity to the features of diabetic retinopathy with JPEG compression; this was compounded by the thin film transistor (TFT) screen. The authors found the quality of uncompressed images on TFT screens too poor to give grading sensitivities which reach current guidelines for diabetic retinopathy screening.

Computer Terminals↗

Free-response receiver operating characteristic evaluation of lossy JPEG2000 and object-based set partitioning in hierarchical trees compression of digitized mammograms.

PURPOSE: To assess the effects of two irreversible wavelet-based compression algorithms--Joint Photographic Experts Group (JPEG) 2000 and object-based set partitioning in hierarchical trees (SPIHT)--on the detection of clusters of microcalcifications and masses on digitized mammograms. MATERIALS AND METHODS: The use of the images in this retrospective image-collection study was approved by the institutional review board, and patient informed consent was not required. One hundred twelve mammographic images (28 with one or two clusters of microcalcifications, 19 with one mass, 17 with both abnormal findings, and 48 with normal findings) obtained in 60 women who ranged in age from 25 to 79 years were digitized and compressed at 40:1 and 80:1 by using the JPEG2000 and object-based SPIHT methods. Five experienced radiologists were asked to locate and rate clusters of microcalcifications and masses on the original and compressed images in a free-response receiver operating characteristic (FROC) data acquisition paradigm. Observer performance was evaluated with the jackknife FROC method. RESULTS: The mean FROC figures of merit for detecting clusters of microcalcifications, masses, and both radiographic findings on uncompressed images were 0.80, 0.81, and 0.72, respectively. With object-based SPIHT 80:1 compression, the corresponding values were larger than the values for uncompressed images by 0.005, 0.009, and -0.005, respectively. The 95% confidence interval for the differences in figures of merit between compressed and uncompressed images was -0.039, 0.033 for the microcalcification finding; -0.055, 0.034 for the mass finding; and -0.039, 0.030 for both findings. Because each of these confidence intervals includes zero, no significant difference in detection accuracy between uncompressed and object-based SPIHT 80:1 compression was observed at a P value of 5%. The F test of the null hypothesis that all of the modes (uncompressed and four compressed modes) were equivalent yielded the following results: F = 0.255, P = .903 for the microcalcification finding; F = 0.340, P = .848 for the mass finding; and F = 0.122, P = .975 for both findings. CONCLUSION: To within the accuracy of these measurements, lossy compression of digital mammographic data at 80:1 with JPEG2000 or the object-based SPIHT algorithm can be performed without decreasing the rate of detection of clusters of microcalcifications and masses.

Adult↗

Evaluation of a quadtree-based compression algorithm with digitized urograms.

The effect of a quadtree-based data-compression algorithm on the diagnostic yield in digitized radiographs was studied for 100 urograms. Each image was digitized and reviewed at nine decreasing compression ratios ranging from 90:1 to 4.2:1, followed by a review of the uncompressed digital images. Four radiologists independently reviewed the digitized images and the original radiographs and agreed on a reference standard of 201 findings. Sensitivity, measured by the number of findings noted on the compressed digital images, decreased with increasing compression ratios at and above the 11:1 level. No loss of sensitivity was noted with a compression ratio of 4.2:1. Sensitivity decreased more precipitously for calcifications than for soft-tissue masses. Only a minimal loss of sensitivity for bilateral renal function was noted, even with high compression ratios. False-positive rates were unaffected by compression. The authors conclude that quadtree compression ratios of 11:1 and higher may result in loss of sensitivity in clinically relevant findings.

Algorithms↗

Impact of patient-controlled compression on the mammography experience.

The authors tested the hypothesis that giving women control over the compression portion of the mammography examination results in a less painful experience, greater overall patient satisfaction, and a radiographic image as good as that produced by means of technologist-controlled compression. One hundred nine women undergoing screening mammography at a hospital-based outpatient clinic were studied. Each underwent two-view, screen-film mammography performed in routine fashion except that, by random assignment, one breast was compressed by the technologist and the other breast, by the patient. Patient-controlled compression was significantly (P = .003) less painful than technologist-controlled compression. Overall patient satisfaction (96% [105 of 109]) and willingness to repeat the experience were extremely high. The majority of images (93.5% [202 of 216]) were rated as having good to excellent compression. With minimal patient education, self-compression resulted in an image at least as good as that produced with technologist-applied compression. Further study of this technique is warranted.

Adult↗

Focal hepatic lesions: effect of three-dimensional wavelet compression on detection at CT.

PURPOSE: To evaluate the effect of three-dimensional, wavelet-based compression on the detection of focal hepatic lesions at computed tomography (CT). MATERIALS AND METHODS: CT images obtained in 69 patients with focal hepatic lesions were studied (35 consecutive cases and 34 cases selected to be difficult on the basis of lesion size or contrast). Image data were compressed by means of a three-dimensional, wavelet-based algorIthm at ratios of 10:1, 15:1, and 20:1. Normal and abnormal sections (on original and compressed images) were reviewed by using an interactive workstation. Four readers rated the presence or absence of a lesion with a five-point scale. RESULTS: At receiver operating characteristic analysis, no statistically significant difference was detected for all cases considered together. Differences approached but did not reach statistical significance for the diagnostic performance of one reader with compressed images (15:1, P = .054; 20:1, P = .051). For the subset of difficult cases, a significant difference was observed with 20:1 compressed images for one reader (P = .026). Diagnostic performance of readers was less certain in normal than in abnormal cases with both original and compressed images (difference was significant for 15:1 [P = .035] and 20:1 [P < .0001] compressed images). CONCLUSION: Three-dimensional wavelet compression is satisfactory at ratios of at least 10:1. Additional studies with a larger sample would help confirm findings with higher ratios.

Cysts↗

Vertebral compression fractures in multiple myeloma. Part I. Distribution and appearance at MR imaging.

PURPOSE: To study the appearance and distribution of vertebral compression fractures on magnetic resonance (MR) images in patients with multiple myeloma. MATERIALS AND METHODS: Two hundred twenty-four vertebral compression fractures were studied on 216 sagittal T1-weighted spin-echo and T2*-weighted gradient-echo MR images of the thoracolumbar spine obtained before and during treatment in 37 patients with multiple myeloma. Vertebral compression fractures observed at diagnosis and during follow-up were determined as being benign- or malignant-appearing at MR imaging according to literature criteria, and their distribution along the spine was recorded. RESULTS: One hundred forty-nine (67%) of the 224 vertebral compression fractures appeared benign; 75 (33%) appeared malignant. Of the 37 patients, 14 (38%) had only benign-appearing vertebral compression fractures at diagnosis. One hundred five fractures (87%) were observed between T-6 and L-4, and 112 (50%) occurred between T-11 and L-3. Eight (4%) vertebral compression fractures involved the upper three thoracic vertebrae. CONCLUSION: Most vertebral compression fractures in patients with multiple myeloma appear benign at MR imaging, and their distribution is similar to that observed in osteoporotic fractures. The possibility of multiple myeloma should not be excluded in patients with benign-appearing vertebral compression fractures at MR imaging.

Adult↗

Compression induced by RV pressure overload decreases regional coronary blood flow in anesthetized dogs.

Pulmonary artery constriction (PAC), a model of right ventricular (RV) pressure overload, flattens or inverts the septum and may flatten the left ventricular (LV) free wall. Finite element (FE) analysis predicts that such deformations may cause substantial compression. This study tests the hypothesis that deformation-induced myocardial compressive stress impedes coronary blood flow (CBF). Colored microspheres ( approximately 2 x 10(6)) were injected into the left atrium of 13 open-chest, anesthetized dogs under control conditions and during PAC, which decreased the end-diastolic transseptal pressure gradient (LV - RV) from 1.6 +/- 1.3 to -3.4 +/- 1.7 mmHg. Septal and LV deformation was assessed with the use of two-dimensional echocardiography, and by FE analysis, the hydrostatic component of stress was assessed. Postmortem, a 2.5-cm wide, LV equatorial ring was divided into 16 endocardial and epicardial samples. PAC decreased CBF in the FE-predicted compression zones, areas with the greatest compression having the greatest reductions in CBF. During PAC, compression reached a maximum of 25.3 +/- 1.8 mmHg on the (LV) endocardial sides of the RV insertion points, areas that saw CBF decrease from 1.05 +/- 0.08 to 0.68 +/- 0.05 ml.min(-1).g(-1) (P < 0.001), more than 30%. CBF decreased (from 1.08 +/- 0.07 to 0.81 +/- 0.07 ml.min(-1).g(-1); P < 0.001) on the RV side of the midseptum, an area with as much as 16.0 +/- 1.0 mmHg of compression. Overall, average compressions of 10 mmHg decreased CBF by approximately 30%. We conclude that acute RV pressure overload deforms the septum and LV and induces compressive stresses that reduce CBF substantially. This may help explain why some patients with pulmonary hypertension and no critical coronary disease have chest discomfort indistinguishable from angina pectoris.

Anesthesia↗

Cariporide enables hemodynamically more effective chest compression by leftward shift of its flow-depth relationship.

When given during closed-chest resuscitation, cariporide (4-isopropyl-methylsulfonylbenzoyl-guanidine methanesulfonate; a selective inhibitor of the Na(+)/H(+) exchanger isoform-1) enables generation of viable perfusion pressures with less depth of compression. We hypothesized that this effect results from greater blood flows generated for a given depth of compression. Two series of 14 rats each underwent 10 min of untreated ventricular fibrillation followed by 8 min of chest compression before defibrillation was attempted. Compression depth was adjusted to maintain an aortic diastolic pressure (ADP) between 26 and 28 mmHg in the first series and between 36 and 38 mmHg in the second series. Within each series, rats were randomized to receive cariporide (3 mg/kg) or NaCl (0.9%; control) before chest compression was started. Blood flow was measured using 15-mum fluorescent microspheres. Less depth of compression was required to maintain the target ADP when cariporide was present in both series 1 (13.6 +/- 1.2 vs. 16.6 +/- 1.2 mm; P < 0.001) and series 2 (15.3 +/- 1.0 vs. 18.9 +/- 1.5 mm; P < 0.001). Despite less compression depth, the cardiac index in cariporide-treated rats was comparable to control rats in series 1 (11.1 +/- 0.7 vs. 11.3 +/- 1.4 ml.min(-1).kg(-1); P = not significant) but higher in series 2 (15.5 +/- 2.3 vs. 9.9 +/- 1.4 ml.min(-1).kg(-1); P < 0.05). Increases in compression depth (from series 1 to series 2) increased myocardial, cerebral, and adrenal blood flow in cariporide-treated rats. We conclude that cariporide enhances the efficacy of closed-chest resuscitation by leftward shift of the flow-depth relationship.

Animals↗

Dynamics of cardiovascular responses to repeated partial umbilical cord compression in late-gestation sheep fetus.

We characterized the detailed hemodynamics of fetal blood pressure, heart rate, common umbilical blood flow, and femoral blood flow responses to partial compression of the umbilical cord and tested the hypothesis that repeated cord compression modulates fetal cardiovascular responses in 10 chronically instrumented fetal sheep at approximately 130 days of gestation. In five fetuses (group I), partial compression of the umbilical cord was induced 12 times, each for 5 min at 15-min intervals. Each cord compression reduced common umbilical blood flow by 50% and produced modest falls in fetal pH (7.33 +/- 0 to 7.29 +/- 0) and arterial PO2 (21.1 +/- 0.2 to 16.8 +/- 0.2 mmHg) and a mild increase in arterial PCO2 (49.9 +/- 0.5 to 54.9 +/- 0.4 mmHg). Sham experiments were performed in five other fetuses (group II). Second-by-second analysis of group I fetal cardiovascular data revealed a clear biphasic response to partial cord compression. Phase I (1st min of cord compression) was characterized by a rapid bradycardia and a rapid femoral vasoconstriction (primary response); phase II (minutes 2-5 of cord compression) was characterized by a delayed bradycardia and a return of femoral vascular resistance toward baseline (secondary response). Repeated cord compression abolished the primary, but not the secondary, cardiovascular responses. These results demonstrate that fetal cardiovascular responses to stress may be modified by preexposure to repeated intrauterine challenges.

Animals↗

Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest.

BACKGROUND: Despite improving arterial oxygen saturation and pH, bystander cardiopulmonary resuscitation (CPR) with chest compressions plus rescue breathing (CC+RB) has not improved survival from ventricular fibrillation (VF) compared with chest compressions alone (CC) in numerous animal models and 2 clinical investigations. METHODS AND RESULTS: After 3 minutes of untreated VF, 14 swine (32+/-1 kg) were randomly assigned to receive CC+RB or CC for 12 minutes, followed by advanced cardiac life support. All 14 animals survived 24 hours, 13 with good neurological outcome. For the CC+RB group, the aortic relaxation pressures routinely decreased during the 2 rescue breaths. Therefore, the mean coronary perfusion pressure of the first 2 compressions in each compression cycle was lower than those of the final 2 compressions (14+/-1 versus 21+/-2 mm Hg, P<0.001). During each minute of CPR, the number of chest compressions was also lower in the CC+RB group (62+/-1 versus 92+/-1 compressions, P<0.001). Consequently, the integrated coronary perfusion pressure was lower with CC+RB during each minute of CPR (P<0.05 for the first 8 minutes). Moreover, at 2 to 5 minutes of CPR, the median left ventricular blood flow by fluorescent microsphere technique was 60 mL. 100 g(-1). min(-1) with CC+RB versus 96 mL. 100 g(-1). min(-1) with CC, P<0.05. Because the arterial oxygen saturation was higher with CC+RB, the left ventricular myocardial oxygen delivery did not differ. CONCLUSIONS: Interrupting chest compressions for rescue breathing can adversely affect hemodynamics during CPR for VF.

Animals↗