PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Capture”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

The determination of liposome captured volume.

Manipulating the process by which lipids assemble to form bilayer membranes has produced a myriad of protocol-dependent liposome types. For each of these systems the arrangement of bilayers is characteristic and can be described by parameters such as aqueous entrapment per mole lipid or captured volume, vesicle size distribution, the average number of lamellae per vesicle and shape. For specific applications as model systems or drug delivery systems specific characteristics are desired. Consequently over the years many techniques have evolved to better quantitate these parameters. Here we focus on and detail several methods to quantitate liposome captured volume. We also briefly describe the available methods to measure the other aforementioned physical properties and discuss their interdependency with captured volume.

Freeze Fracturing↗

Absence of daily cycles in plasma sex steroids in male and female tuatara (Sphenodon punctatus), and the effects of acute capture stress on females.

The possible existence of daily cycles in plasma concentrations of sex steroids was examined in wild male and female tuatara (Sphenodon punctatus). Samples were collected from freshly captured animals at dusk, middle of the night, dawn, and middle of the day in January (summer) and July (winter). Males showed daily cycles in mean body temperature (Tb) in both seasons but no daily cycle in mean plasma testosterone concentration in either season. Vitellogenic female tuatara in January and females in mixed reproductive condition in July also showed significant daily variation in Tb. However, there were no daily cycles in mean plasma concentrations of estradiol, testosterone, or progesterone in either group of females. Vitellogenic female tuatara subjected to an acute capture stress (3-hr confinement) in January had mean plasma concentrations of estradiol and testosterone that did not differ from those of free-roaming females. However, progesterone and Tb were significantly higher in captives than in free-roaming females. The elevation in progesterone may result from physical confinement, the difference in Tb, or both. These data suggest that seasonal fluctuations in circulating concentrations of plasma sex steroids in tuatara can be determined using samples collected at different times of the 24-hr cycle. However, the effects of acute capture stress and/or changes in Tb on plasma progesterone concentrations need to be considered in future studies on this and possibly other female reptiles.

Animals↗

Measurement of monoclonal antibody concentrations in hybridoma cultures: comparison of competitive inhibition and antigen capture enzyme immunoassays.

Competitive inhibition and antigen capture enzyme immunoassays were compared for the measurement of mouse monoclonal IgGl antibody produced by a hybridoma culture. Both methods yielded standard curves that were linear over several orders of magnitude, and both were comparable in sensitivity (10 ng/ml). However, the slope of the antigen capture curve was flatter than the slope for competitive inhibition. This difference in slope, coupled with a larger average standard deviation for each point on the standard curve for antigen capture, resulted in a significantly larger range of variability in IgGl levels. It is concluded that the competitive inhibition enzyme immunoassay method is better suited to the precise quantification of mouse monoclonal antibodies in hybridoma culture supernatants.

Animals↗

Measurement of antigen-specific mouse IgE by a fluorometric reverse (IgE-capture) ELISA.

A reverse, or IgE-capture, enzyme-linked immunosorbent assay (ELISA) for measuring ovalbumin-specific IgE antibody in the serum of immunized mice has been developed. Microplate wells were first coated with a commercial anti-mouse IgE rat monoclonal antibody, and then incubated with two-fold serial dilutions of test sera with 10% normal mouse serum as diluent for the capturing of only IgE class molecules. Biotinylated ovalbumin and then beta-D-galactosidase-conjugated streptavidin were added and, finally, 4-methylumbelliferyl-beta-D-galactoside was used as the enzyme substrate. The fluorescence intensity of the reaction product (4-methylumbelliferone) was determined on a microplate fluorescence reader. The sensitivity of this assay was equal to that of passive cutaneous anaphylaxis (PCA). In contrast to indirect ELISAs this IgE-capture assay is free from competition by non-IgE antibodies. Furthermore, it requires much less antigen than the PCA assay.

Animals↗

A sensitive and specific ELISA using monoclonal capture antibodies for the detection of HLA antigens in blood stains.

A double antibody ELISA technique is described to detect HLA antigens in extracts of blood stains. The assay involves capture of free HLA determinants using an immobilized monoclonal antibody directed against monomorphic regions of HLA class I and HLA class II antigens. The captured antigens are then detected using alloantisera directed against the polymorphic regions of the captured HLA entities. The technique is able to detect specific HLA-A, B, and DR antigens in extracts prepared from blood smears as well as from dried and freshly thawed lymphocytes. The assay may be of potential use in forensic medicine, particularly in instances where extraction of nucleic acids for fingerprinting is not feasible.

Blood Stains↗

A silicon sensor-based filtration immunoassay using biotin-mediated capture.

A sensitive sandwich immunoassay for human chorionic gonadotropin (hCG) was developed with biotin-mediated filtration capture and silicon sensor detection. A high density of biotin on the membrane assured efficient capture of complexes containing streptavidin and analyte. Capture efficiency was not affected over a wide range of filtration flow rates or biotin concentrations. The assay utilized the pH sensing ability of the light addressable potentiometric sensor (LAPS) for the detection of urease-antibody conjugates. A LAPS reader was constructed which allowed the enzyme conjugate to be detected in approximately 1 microliter volumes. Effects from variations in detection volume were studied. 10 pg of hCG could be detected in an assay time of 20 min with four standard deviations separation from background. Comparison to a commercial RIA was made.

Antibodies, Monoclonal↗

Development of a novel substrate capture immunoassay for the detection of a neutral metalloproteinase capable of degrading basement membrane (type IV) collagen.

This paper describes the development of a modified substrate capture immunoassay useful in the detection of a neutral metalloproteinase enzyme, type IV collagenase. Capture and immobilization of this enzyme was achieved by coating the microtiter plate with gelatin, an alternative substrate for this enzyme. The captured enzyme could then be detected by affinity-purified rabbit anti-type IV collagenase antibodies prepared against synthetic peptides from the amino terminus of the enzyme. Soluble type IV collagenase was readily detected in samples known to contain this enzyme. Using purified enzyme this assay method was shown to detect less than 50 ng of latent type IV collagenase. Using EDTA, an inhibitor of this metalloproteinase, gelatin binding was shown to be independent of catalytic activity.

Amino Acid Sequence↗

Protein A antibody-capture ELISA (PACE): an ELISA format to avoid denaturation of surface-adsorbed antigens.

Adsorption to a polymeric surface may severely alter the antigenic structure of proteins through unfolding. A conventional capture ELISA in which a protein antigen is adsorbed to the microtiter plate may be unsuitable for testing the specificity of antibodies directed against native proteins (C. Schwab and H.R. Bosshard (1992) J. Immunol. Methods 147, 125). This problem can be overcome by PACE, a new ELISA procedure in which monoclonal or polyclonal antibodies are first allowed to equilibrate with biotinylated antigen in solution. Thereafter, the antigen-antibody complex (and free antibody) is bound to the microtiter plate through protein A. Captured antigen-antibody complex is detected by streptavidin-alkaline phosphatase and p-nitrophenylphosphate. A competition assay is accomplished by co-incubation of biotinylated and non-biotinylated antigens before capture to the protein A-coated plate. PACE combines the advantages of a solution-phase immunoassay (Farr assay) with the ease of a solid-phase ELISA. PACE has been used to test the conformational specificity of polyclonal and monoclonal antibodies against native and denatured cytochrome c, and of a polyclonal antiserum against a coiled coil leucine zipper peptide. Since a biotin group can be attached specifically to the N-terminal residue of synthetic peptides, PACE is also useful for assaying reactivity against peptide antigens which are difficult to adsorb to microtiter plates.

Amino Acid Sequence↗

Universal cloning and direct sequencing of rearranged antibody V genes using C region primers, biotin-captured cDNA and one-side PCR.

Polymerase chain reaction (PCR) cloning has greatly facilitated the cloning of heavy and light chain genes from B cells and hybridomas and has been critical for the generation of natural antibody gene libraries for expression in bacteria and on filamentous phages. There remain difficulties, however, in cloning VH and VL genes from a number of mouse and rat hybridoma lines and from B cells from several other species due to insufficient sequence information. Here we describe a rapid and 'universal' strategy for cloning rearranged antibody genes from any species for which the sequence of the C segment(s) are known. First strand synthesis is primed with a biotinylated C region primer and full length cDNA is captured on streptavidin-coated magnetic beads for tailing with dGTP and terminal deoxynucleotidyl transferase. After tailing, the cDNA is captured again, amplified using polyC primers and used for direct sequencing or cloning. The use of C region primers and cDNA capture ensures that this one-side PCR procedure is efficient and rapid as well as being entirely independent of the sequence of the V segment. We demonstrate its application to the direct sequencing or cloning of the H and L chain genes from six mouse and rat hybridomas and propose that the method described will find applications in three areas: (i) cloning rearranged antibody genes in all cases in which cloning with V-J primers is not possible; (ii) repertoire studies in which an unbiased cloning procedure is required for accurate estimate of gene usage; and (iii) generation of VH and VL gene libraries from immunised animals.

Amino Acid Sequence↗

Capture errors and sequencing after frontal brain lesions.

This study addresses the effect of strong routine associations (capture errors) in hindering the control of on-line serial or sequencing tasks. Patients with focal frontal lobe lesions were significantly inferior to normal control subjects and patients with posterior brain lesions, when conditions that may lead to capture errors were present. The results suggest that the primary dysfunction exhibited by patients with frontal lobe lesions on capture error tasks may lie not in the disengagement from the invalid associations but in focusing attention to alternative strategies of response.

Adult↗

Moving two-dimensional patterns can capture the perceived directions of lower or higher spatial frequency gratings.

Coherent plaid motion is produced by superimposing two one-dimensional gratings of the same spatial frequency moving +/- 60 degrees from the intersection-of-constraints (IOC) resultant direction. These moving plaids were found to change the perceived direction of a third one-dimensional grating, either 6-fold lower or higher in spatial frequency, from traveling in one of the plaid's component direction to the IOC resultant direction. We describe this phenomenon as coherence capture. Coherence capture was found to be effective between plaids with 0.5, 1.0, and 1.5 c/deg components and gratings of 3.0, 6.0 and 9.0 c/deg respectively. It was also found to be effective between plaids with 3.0 c/deg components and gratings of 0.5 c/deg. However, coherence capture between higher spatial frequency plaids and lower spatial frequency gratings became less effective when the component spatial frequencies of the plaid increased.

Humans↗

The immunochemistry of sandwich ELISAs--I. The binding characteristics of immunoglobulins to monoclonal and polyclonal capture antibodies adsorbed on plastic and their detection by symmetrical and asymmetrical antibody-enzyme conjugates.

Radiolabelled bovine IgG1, IgG2, SIgA and IgM and heavy-chain specific polyclonal and monoclonal antibodies to these isotypes were employed as models to investigate immunochemical aspects of sandwich enzyme immunoassays (ELISAs). The titration plots obtained by measuring enzyme activity paralleled those obtained when the binding of radiolabelled immunoglobulins to solid-phase capture antibodies was quantitated. As predicted from the Mass Law, the percentage of labelled immunoglobulin which was bound remained constant over the range in which the sandwich ELISA titration was linear on a log-log plot. Also as predicted from the Mass Law, increasing the solid-phase concn of polyclonal antibodies by affinity purification increased the linear region of the log-log ELISA plot and the corresponding region over which a constant percentage of immunoglobulin binding was observed. When used as capture antibodies adsorbed on plastic at equal concns, the best monoclonal antibodies were 1/8- less than 1/16 as effective as their polyclonal counterparts in binding iodinated bovine immunoglobulins; these differences can be directly interpreted to result from an 8 and greater than 16-fold higher functional, relative affinity of the polyclonal reagents. Steric hindrance was shown to occur when symmetrical sandwich ELISAs, i.e. capture and detection antibody are both heavy-chain specific, are used to measure monomeric but not IgM immunoglobulins. The use of an asymmetrical configuration, i.e. anti-Fab antibody-enzyme conjugates, avoids this problem. Symmetrical conjugates based on the avidin-biotin system, horseradish peroxidase or alkaline phosphatase, were less effective than their asymmetrical (anti-Fab) counterparts. Evidence that the lower activity of symmetrical conjugates was due to steric hindrance was illustrated using horseradish peroxidase-antibody conjugates of different sizes. Sandwich assays using affinity-purified, polyclonal solid-phase antibodies and an asymmetrical conjugate were judged to be immunochemically and economically optimal. Using an asymmetrical configuration, the non-linear nature of sandwich ELISA titration plots is the predictable result of changing antibody to antigen ratios in an antibody-limiting system, and not the result of steric hindrance of the detection system.

Animals↗

The immunochemistry of sandwich ELISAs--III. The stoichiometry and efficacy of the protein-avidin-biotin capture (PABC) system.

The protein-avidin-biotin capture (PABC) system was developed to decrease the adsorption-induced loss of antigen capture capacity (AgCC) of capture antibodies (CAb) used in sandwich ELISAs. This system involves immobilization of biotinylated CAbs through linkage by streptavidin (SA) to biotinylated carrier proteins adsorbed on polystyrene. Studies reported here describe the stoichiometry of the system and the influence of biotinylation of different carrier proteins and CAbs on the reaction stoichiometry and the AgCC of CAbs. Because of the widespread use of sandwich ELISAs to measure the concn of multivalent protein antigens, the AgCCs of monoclonal and polyclonal CAbs to pig IgG in the PABC system were compared with the AgCCs of these Abs immobilized on the plastic by direct adsorption. Optimal assay conditions for the carrier were obtained when 1 microgram/ml of the biotinylated protein was added to the polystyrene solid phase. An increasing degree of biotin substitution in three carrier proteins was paralleled by an increasing AgCC until a constant maximum was reached. Under conditions of maximal AgCC, 120 ng of the carrier rabbit gamma globulin (RGG; i.e. RGG25biot) was bound to polystyrene, which in turn yielded the maximum amount (i.e. 100 ng) of bound streptavidin (SA; Bdngmax) when 20 micrograms/ml of SA was added. Under conditions giving the Bdngmax for SA, CAb12biot yielded a higher Bdngmax than did CAb25biot or CAb2biot. When the AgCC of equal amounts of differentially biotinylated CAbs were compared, the following order of AgCC was observed: CAb12biot greater than CAb12biot greater than CAb25biot. Hence, while the maximal amount of CAb is immobilized on SA when CAb12biot is used, optimal AgCC is achieved with CAb2biot. The carrier:SA:CAb2biot ratio was 1:2:1 while that for carrier:SA:CAb12biot was 1:2:2. The same ratio was obtained using IgG2biot from four different species. Monoclonal antibodies to swine IgG showed a 5-6-fold increase in Bd%max when immobilized as CAbs using the PABC system versus when adsorbed on polystyrene. Plots of these data suggest that the differences result from a loss of functional affinity. On the contrary, no significant differences in Bd%max and hence functional affinity were observed when a polyclonal antibody to pig IgG was compared using the two assay configurations. Furthermore, when the globulin fraction of the anti-pig polyclonal was adsorbed on plastic, it behaved nearly as well as its affinity-purified counterpart immobilized by the PABC system. The PABC system appears to offer significant advantages for sandwich ELISAs utilizing monoclonal antibodies as the CAb, and may offer some advantages in other s

Adsorption↗

Enzyme-linked immunosorbent assay for mumps IgM antibody: comparison of IgM capture and indirect IgM assay.

We have established two enzyme-linked immunosorbent assays (ELISAs) for detection of mumps IgM antibody, i.e., indirect IgM ELISA and IgM capture ELISA, for serodiagnosis of recent mumps infection. In the latter method, peroxidase-conjugated monoclonal antibody to mumps virus was employed. Both methods detected mumps antibody of IgM class only in serum fractions separated by centrifugation through a sucrose density gradient. Optical density values given by both ELISAs were correlated for most sera examined. Indirect IgM ELISA, however, gave a false positive reaction for sera containing both rheumatoid factor and mumps IgG antibody, while giving a false negative reaction for sera containing high titers of mumps IgG antibody. This technique was, therefore, less reliable than IgM capture ELISA. IgM antibody detectable by IgM capture ELISA was present in all patients with mumps by the fifth day of illness and persisted for up to 3 mth in most and up to 5 mth in same cases.

Antibodies, Monoclonal↗

A capture antibody ELISA for detection of antibodies against bovine enterovirus.

A capture antibody ELISA was developed for detecting antibodies against bovine enterovirus. Chicken IgG F(ab')2 fragments against strain J2129 captured virus effectively. The captured virus was used to detect specific antibodies against the virus in bovine sera. The specificity of the ELISA is high. The factors affecting the specificity are discussed. The assay is more sensitive and economic than traditional serum neutralisation.

Animals↗

Evaluation of end-point titration, single dilution and capture enzyme immunoassays for measurement of antirotaviral IgA and IgM in infantile secretions and serum.

In order to facilitate measurement of antirotaviral IgA in large collections of faeces and secretions, adaptations of enzyme immunoassay methods for estimating antirotaviral IgA and IgM in duodenal fluid, saliva, faeces and serum were studied. To quantitate specific IgA, a single dilution of each sample was assayed. Results were expressed as antirotaviral IgA units derived from a standard curve. Units were calculated by log-logit analysis on computer. There was strong correlation between antirotaviral IgA units and end-point titres in 257 faecal samples (correlation coefficient r = 0.92) and in 182 duodenal fluids and salivary samples (correlation coefficient r = 0.74). The assay was validated using acute and convalescent faeces from children with or without rotavirus infection. Immune conversions in IgA were detected in 33 (75%) of the children by units and 34 (77%) by titres. None of nine children with gastroenteritis due to other infectious agents showed immune conversions to rotavirus. A monoclonal capture IgM assay showed similar end-point titres and numbers of immune conversions when compared with a direct assay for antirotaviral IgM in serum and secretions. Use of the capture method eliminated false-positive reactions with the cell control. The assay for antirotaviral IgA units in secretions is simple, rapid, reproducible and reliable, and has proven of value in longitudinal epidemiological studies of rotavirus coproIgA profiles. Both the capture IgM technique and the single dilution IgA method permit analysis of large numbers of specimens and are appropriate for examination of immune responses to natural rotavirus infection or during vaccine trials.

Antibodies, Viral↗

Antigen-capture ELISA for viral haemorrhagic septicaemia virus serotype I.

An antigen-capture ELISA for viral haemorrhagic septicaemia virus serotype I (VHSV I) was developed. The assay employs two monoclonal antibodies (mAb) directed against distinct epitopes of the viral envelope glycoprotein (Gp). The antigen bound by the capture mAb (A17) was detected by addition of a second mAb (L7) conjugated to horseradish peroxidase, followed by addition of the enzyme substrate. The technique is highly sensitive, enabling detection of the virus at a protein concentration as low as 1 ng/ml of total proteins (1.5 fmol of envelope Gp per ml) in purified preparations. VHSV I was also detected in culture supernatants (5 x 10(5) PFU/ml) and in extracts of kidney and spleen of rainbow trout infected experimentally (5 x 10(5) PFU/ml). The assay was highly specific: infectious haematopoietic necrosis virus, infectious pancreatic necrosis virus, spring viraemia of carp virus, pike fry rhabdovirus, eel rhabdovirus and perch rhabdovirus could not be detected by the antigen-capture ELISA for VHSV I.

Antibodies, Monoclonal↗

Development and evaluation of a capture ELISA for IgM antibody to the human cytomegalovirus major DNA binding protein.

A new capture ELISA (ELAb) for determination of the IgM antibody response to the human cytomegalovirus major DNA binding protein (p52) was developed by using a p52-specific monoclonal antibody. As a reference test, a capture ELISA using in parallel viral- and cell-control labeled antigens (ELA) was employed. General specificity, which was determined on 180 unselected IgM-negative sera from an adult population was 100%; stringent specificity, which was evaluated on 108 potentially interfering sera from patients with Epstein-Barr virus infectious mononucleosis, autoimmune diseases, rheumatoid factor or treated with radioimmunotherapy, was 96.3%; finally, clinical specificity, determined on 79 IgM-negative sera drawn prior to onset of primary HCMV infection, was 100%. Thus, the overall specificity was 98.9% (363/367 IgM negative tested sera). Sensitivity assayed on 277 IgM-positive sera was 100%. The study of the kinetics of the IgM antibody response in sequential blood samples from 9 immunocompetent and 9 heart transplanted patients showed that, while in the immunocompetent p52-specific IgM titer fell sharply 2-3 months after onset and was virtually undetectable 12 months after onset, in the immunocompromised the IgM response persisted for longer than a year. Recurrent HCMV infections were associated with a high titer IgM response in 6 (30%), and with a low IgM response in another 6 (30%) heart transplanted patients within a group of 20 patients sequentially examined. Finally, IgM antibodies were detected in all 4 infants with congenital infection and in 5 of 6 infants with neonatal infection. The results show that the HCMV p52-specific IgM antibody response parallels that obtained by ELA, thus representing a major component of it. ELAb is highly sensitive, specific and reproducible. It represents a major advance among capture ELISA techniques, allowing detection of IgM antibody reactive to a specific viral protein.

Antibodies, Monoclonal↗