PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Neuronavigation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

Waterjet dissection versus ultrasonic aspiration in epilepsy surgery.

OBJECTIVE: Waterjet dissection is currently under close investigation in neurosurgery. Experimentally, precise brain parenchyma dissection with vessel preservation has been demonstrated. Clinically, the safety of the instrument has already been proved. However, precise data demonstrating that waterjet dissection indeed reduces surgical blood loss are still missing. METHODS: The authors applied the waterjet device in a prospective randomized study in comparison with the ultrasonic aspirator. Because there is little variability in the procedure, 30 patients with temporal lobe epilepsy receiving a tailored temporal lobe resection between December 1999 and October 2002 were selected for this study. Intraoperative vessel preservation, intraoperative blood loss, surgical complications, and epilepsy outcome were evaluated. All patients were followed at 3-month intervals. RESULTS: During surgery, both instruments were easy to handle. Only with the waterjet dissector, however, were even small intraparenchymal blood vessels preserved. Intraoperative blood loss was significantly reduced with the waterjet (mean, 70 +/- 46 ml) compared with the ultrasonic aspirator (mean, 121 +/- 48 ml). However, no difference in the necessity for blood transfusion occurred. No difference was observed with respect to operation time (238.6 +/- 37.0 min with the waterjet, 247.5 +/- 41.5 min with the ultrasonic aspirator), surgical complications, and outcome. CONCLUSION: The waterjet dissector enables a significant reduction of intraoperative blood loss in the investigated setting. However, further studies are needed to confirm these results with a larger number of patients. Studies also are needed to prove that the reduction of blood loss is of clinical relevance for the outcome of the patients.

Adolescent↗

Endoscopic aqueductal stenting via the fourth ventricle under navigating system guidance: technical note.

OBJECTIVE: We report three patients with symptomatic isolated fourth ventricle after ventriculoperitoneal shunt placement for hydrocephalus associated with ventricular hemorrhage. All three patients were treated successfully with our new method of endoscopic aqueductal stenting under navigating system guidance. METHODS: A therapeutic rigid endoscope was inserted through the thin cerebellar hemisphere, and endoscopic aqueductal stenting was performed via the enlarged fourth ventricle under navigating system guidance. RESULTS: All three patients underwent successful procedures with good outcomes. CONCLUSION: Our method of aqueductal stenting is a reasonable choice for initial treatment of patients with isolated fourth ventricle, and it entails less invasive neurosurgery.

Cerebral Aqueduct↗

Intuitive intraoperative ultrasound guidance using the Sonic Flashlight: a novel ultrasound display system.

OBJECTIVE: The Sonic Flashlight (SF) is a new handheld ultrasound (US) display device being developed at our institution. It replaces the standard monitor on a conventional ultrasound (CUS) system with a miniature monitor and half-silvered mirror to reflect real-time US images into the body. With the SF, the imaged body part appears translucent, with the US image appearing to float below the surface of the anatomy, exactly where it is being scanned. The SF merges the patient, US image, instrument, and operator's hands into the same field of view, allowing the user to operate directly on the US image using normal hand-eye coordination. In contrast, CUS procedures result in displaced hand-eye coordination when the operator looks away from the patient to view the CUS monitor. Intraoperatively, the SF may make localizing and accessing tumors, foreign bodies, hematomas, vascular malformations, and ventricles easier and more accurate, especially for those without extensive CUS training. METHODS: In this cadaver study, the SF was used to visualize the brain and guide a needle into an implanted simulated tumor. The needle was inserted both in the US plane and outside of the US plane. INSTRUMENTATION: Sonic Flashlight fifth generation research prototype. CONCLUSION: The needle was easily and intuitively visualized and guided into the lesion, both within and outside of the US plane. By having the US image appear directly beneath the brain surface, the surgeon can easily and quickly guide the needle or surgical instrument to the lesion. The operator's eyes never have to leave the surgical field, as they do with CUS technology. The impact of this device on neurosurgical procedures could be significant. The ease of use, intuitive function, and small instrument size allow the surgeon to quickly localize lesions, confirm surgical positioning, and assess postoperative results.

Brain Neoplasms↗

Microsurgical anatomy of the transcallosal anterior interforniceal approach to the third ventricle.

OBJECTIVE: We explored relevant regional microanatomy as it relates to the challenging anterior interforniceal (AIF) approach for removing hypothalamic hamartomas. METHODS: Five silicone-injected cadaveric heads were dissected by use of frameless stereotactic navigation to reveal microanatomy and extent of exposure through the transcallosal AIF approach. Distances between trajectories to the coronal suture and the genu of the corpus callosum (CC) and between the posterior border of the anterior commissure to the lower end of the rostrum of the CC and posterior border of the foramen of Monro were measured. RESULTS: The AIF approach provided adequate access to the anterior third ventricle and related structures (i.e., hypothalamus, infundibular recess, and mamillary bodies) through the corridor bounded by the anterior commissure anteriorly and the choroid plexus at the foramen of Monro posteriorly. The mean distances from the posterior trajectory to the coronal suture and the genu of the CC were 44.8 mm (range, 43.8-46.2 mm) and 14.88 mm (14.1-15.7 mm), respectively. The mean distance from the anterior trajectory posterior to the coronal suture was 4.66 mm (0-8.9 mm), and 32.6 mm (30.5-33.9 mm) to the genu of the CC. The mean length of callosotomy was 17.52 mm (16.2-19.1 mm). The mean distance between the posterior border of the anterior commissure and the lower end of the rostrum of the CC was 5.22 mm (4.6-5.6 mm), and 10.52 mm (9.7-11.5 mm) to the posterior border of the foramen of Monro. CONCLUSION: The technically safe AIF approach permitted limited interforniceal splitting, no major deep vein manipulation, and adequate visualization of the hypothalamus, infundibular recess, and mamillary bodies.

Cadaver↗

Operation of arteriovenous malformations assisted by stereoscopic navigation-controlled display of preoperative magnetic resonance angiography and intraoperative ultrasound angiography.

OBJECTIVE: To study the application of navigated stereoscopic display of preoperative three-dimensional (3-D) magnetic resonance angiography and intraoperative 3-D ultrasound angiography in a clinical setting. METHODS: Preoperative magnetic resonance angiography and intraoperative ultrasound angiography are presented as stereoscopic images on the monitor during the operation by a simple red/blue technique. Two projections are generated, one for each eye, according to a simple ray casting method. Because of integration with a navigation system, it is possible to identify vessels with a pointer. The system has been applied during operations on nine patients with arteriovenous malformations (AVMs). Seven of the patients had AVMs in an eloquent area. RESULTS: The technology makes it easier to understand the vascular architecture during the operation, and it offers a possibility to identify and clip AVM feeders both on the surface and deep in the tissue at the beginning of the operation. All 28 feeders identified on the preoperative angiograms were identified by intraoperative navigated stereoscopy. Twenty-five were clipped at the beginning of the operation. The other three were clipped at a later phase of the operation. 3-D ultrasound angiography was useful to map the size of the nidus, to detect the degree of brain shift, and to identify residual AVM. CONCLUSION: Stereoscopic visualization enhances the surgeon's perception of the vascular architecture, and integrated with navigation technology, this offers a reliable system for identification and clipping of AVM feeders in the initial phase of the operation.

Adult↗

Integration of [11C]methionine-positron emission tomographic and magnetic resonance imaging for image-guided surgical resection of infiltrative low-grade brain tumors in children.

OBJECTIVE: To evaluate the interest of integrating positron emission tomography (PET) images with the radiolabeled tracer [(11)C]methionine (Met) into the image-guided navigation planning of infiltrative low-grade brain tumors (LGBTs) in children. METHODS: Twenty-two children underwent combined Met-PET with magnetic resonance imaging (MRI) scans in the planning of a navigation procedure. These children presented an LGBT (astrocytomas, 10; oligodendrogliomas, 4; ependymomas, 4; gangliogliomas, 4) located close to functional areas. Tumor boundaries were ill-defined on MRI (including T2-weighted and fluid-attenuated inversion-recovery scans) and could not be clearly identified for allowing a complete, or at least a large, image-guided resection. The PET tracer Met was chosen because of its higher sensitivity and specificity than MRI to detect tumor tissue. The level and extension of MET uptake were analyzed to define the PET contour, subsequently projected onto MRI scans to define a final target contour for volumetric resection. The quality of tumor resection was assessed by an early postoperative MRI and Met-PET workup. RESULTS: In 20 of the 22 children with ill-defined LGBTs, PET improved tumor delineation and contributed to define a final target contour different from that obtained with MRI alone. Met-PET guidance allowed a total resection of Met uptake in 17 cases that were considered total tumor resections because the operative margin left in place contained nontumor tissue. CONCLUSION: These data suggested that Met-PET guidance could help to improve the number of total resections and the amount of tumor removed in infiltrative LGBTs in children.

Adolescent↗

Evaluation of fractionated radiotherapy and gamma knife radiosurgery in cavernous sinus meningiomas: treatment strategy.

OBJECTIVE: To investigate the respective role of fractionated radiotherapy (FR) and gamma knife stereotactic (GKS) radiosurgery in cavernous sinus meningioma (CSM) treatment. METHODS: The authors report the long-term follow-up of two populations of patients harboring CSMs treated either by FR (Group I, 38 patients) or GKS radiosurgery (Group II, 36 patients). There were 31 females with a mean age of 53 years in Group I and 29 females with a mean age of 51.2 years in Group II. In 20 patients (Group I) and 13 patients (Group II), FR and GKS radiosurgery were performed as an adjuvant treatment. In 18 patients (Group I) and in 23 patients (Group II), FR and GKS radiosurgery were performed as first line treatment. In our early experience with GKS radiosurgery (1992, date of gamma knife availability in the department), patients with tumors greater than 3 cm, showing close relationship with the optic apparatus (<3 mm) or skull base dural spreading, were treated by FR. Secondarily, with the advent of new devices and our growing experience, these criteria have evolved. RESULTS: The median follow-up period was 88.6 months (range, 42-168 mo) for Group I and 63.6 months (range, 48-92 mo) for Group II. According to Sekhar's classification, 26 (68.4%) patients were Grade III to IV in Group I and 10 (27.8%) patients in Group II (P < 0.05); 23 (60.5%) patients had extensive lesions in Group I and 7 (19.4%) patients in Group II (P < 0.05). Mean tumor volume was 13.5 cm in Group I and 5.2 cm in Group II (P < 0.05). Actuarial progression-free survival was 94.7% and 94.4% in Group I and II, respectively. Clinically, improvement was seen for 24 (63.2%) patients in Group I and for 21 (53.8%) patients in Group II (P > 0.05). Radiologically, 11 (29%, Group I) patients and 19 (Group II, 52.7%) patients showed tumor shrinkage (P = 0.04). Transient morbidity was 10.5% in Group I and 2.8% in Group II. Permanent morbidity was 2.6% in Group I and 0% in Group II. CONCLUSION: FR and GKS radiosurgery are safe and efficient techniques in treatment of CSMs, affording comparable satisfactory long-term tumor control. However, GKS radiosurgery provides better radiological response, is far more convenient, and fits into most patients lives much better than FR. Therefore, in the authors' opinion, GKS radiosurgery should be advocated in first intention for patients with CSMs, whereas conventional radiotherapy should be reserved for cases that are not amenable to this technique, thus making these two therapeutic modalities not alternative but complementary tools in CS meningioma treatment strategy.

Adult↗

Endoscopic transsphenoidal pituitary surgery with intraoperative magnetic resonance imaging.

OBJECTIVE: The two most recent significant advances in pituitary surgery have been the endonasal endoscopic approach and intraoperative magnetic resonance imaging (IMRI). Each provides improved visualization of intra- and parasellar anatomy with the goal of attaining a complete resection. The combination of the two techniques has not been previously reported in the literature. METHODS: We performed endoscopic, endonasal resection of pituitary macroadenomas in 15 patients using the Polestar N-10 (0.12T) IMRI (Odin Medical Technologies, Inc., Newton, MA). Eleven patients had nonfunctioning tumors, three had acromegaly, and one had a medication-resistant prolactinoma. The effect of the magnetic field on the cathode ray tube screen and the image quality of the IMRI images were assessed. The presence of residual tumor on IMRI was noted and then re-examined with the endoscope. RESULTS: Although the Polestar N-10 is a low Tesla magnet, the IMRI caused significant distortion of the cathode ray tube screen regardless of the viewing angle. This was overcome with the use of a wall-mounted plasma screen. IMRI images were obtained in all cases and were of sufficiently high quality to demonstrate adequate decompression of the optic chiasm and the removal of all suprasellar tumor. In three cases, residual tumor was found with IMRI that was resected endoscopically before the completion of surgery. In four other cases, potential residual tumor was examined endoscopically and found to be normal postoperative change. In eight cases no residual intrasellar tumor was seen on the IMRI. Preresection visual deficits improved in all cases and the insulin-like growth factor levels normalized in two of three cases. There were no delayed cerebrospinal fluid leaks. CONCLUSION: Combining intraoperative endoscopy and IMRI is feasible and distortion of the cathode ray tube screen can be overcome with the use of either a plasma or liquid crystal display screen. Each technology provides complementary information, which can assist the surgeon in safely maximizing the extent of resection. In this small series using a low-field magnet, rates of residual tumor following endoscopic transsphenoidal surgery were less than have been reported following microscope-based transsphenoidal surgery.

Adenoma↗

Surgical management of posterior fossa arteriovenous malformations.

OBJECTIVE: Arteriovenous malformations (AVMs) involving the cerebellum and brainstem are relatively rare lesions that most often present clinically as a result of a hemorrhagic episode. Although these AVMs were once thought to have a more aggressive clinical course in comparison with supratentorial AVMs, recent autopsy data suggests that there may be little difference in hemorrhage rates between the two locations. Although current management of these lesions often involves preoperative embolization and stereotactic radiosurgery, surgical resection remains the treatment of choice, conferring immediate protection to the patient from the risk of future hemorrhage. METHODS: Most symptomatic AVMs that involve the cerebellum and the pial or ependymal surfaces of the brainstem are candidates for surgical resection. Preoperative angiography and magnetic resonance imaging studies are critical to determine suitability for resection and choice of operative exposure. In addition to considering the location of the nidus, arterial supply, and predominant venous drainage, the surgical approach must also be selected with consideration of the small confines of the posterior fossa and eloquence of the brainstem, cranial nerves, and deep cerebellar nuclei. RESULTS: Since the 1980s, progressive advances in preoperative embolization, frameless stereotaxy, and intraoperative electrophysiologic monitoring have significantly improved the number of posterior fossa AVMs amenable to microsurgical resection with minimal morbidity and mortality. CONCLUSION: Future improvements in endovascular technology and stereotactic radiosurgery will likely continue to increase the number of posterior fossa AVMs that can safely be removed and further improve the clinical outcomes associated with microsurgical resection.

Arteriovenous Fistula↗

Quantification and comparison of telovelar and transvermian approaches to the fourth ventricle.

OBJECTIVE: To quantify the exposure to the fourth ventricle obtained with the telovelar and transvermian approaches. METHODS: The telovelar, with and without C1 posterior arch removal, and transvermian approaches were performed on six cadaveric heads. The area of surgical exposure was calculated from triangles formed by defined anatomic points. A robotic microscope was used to determine the "angle of approach" for the same points. RESULTS: The maximal allowable vertical angle of attack to the obex of the fourth ventricle was significantly greater with the telovelar approach than with the transvermian approach (P < 0.002), but there was no difference at the rostral fourth ventricle. The maximal allowable horizontal angle of attack at the level of the obex, Luschka, and rostral fourth ventricle was significantly greater with the telovelar than with the transvermian approach (P < 0.001). Removal of the C1 posterior arch with the telovelar approach significantly increased the vertical angle of approach to the obex (P < 0.001) and rostral aspect of the fourth ventricle (P = 0.005) compared with the telovelar alone. The telovelar approach with C1 arch removal offered a larger working area than the transvermian approach (P < 0.001). CONCLUSION: Except for the vertical angle to the rostral aspect of the fourth ventricle, the telovelar approach provides greater angle of exposure in all planes than the transvermian approach. Removal of the C1 posterior arch obviates this sole advantage of the transvermian approach. The telovelar approach offers a corridor through noneloquent arachnoid planes and a safe and capacious working environment.

Cerebellum↗

Three-dimensional computed tomographic analysis of the relationship between the arcuate eminence and the superior semicircular canal.

OBJECTIVE: The location of the superior semicircular canal (SSC) is often determined intraoperatively based on its topographic association with the arcuate eminence (AE). This determination is not always possible because of the potential variability in the relationship between these two structures. The goal of this study was to describe the three-dimensional (3-D) relationship between the AE and SSC using 3-D computed tomography (CT) and to evaluate the utility of 3-D CT for preoperative planning for surgical approaches to the middle cranial fossa. METHODS: We studied 11 patients (22 sides) radiographically using 0.8- to 1-mm thick reconstructed CT images. A standard set of structural relationships was measured between the AE, SSC, and other regional landmarks. RESULTS: 3-D CT clearly demonstrated the relationships between traditional landmarks along the petrous ridge and middle cranial fossa. The relationship between the arcuate eminence and SSC was found to be highly variable. The average distance between the tips of the two structures was found to be 5.7 mm (range, 2.7-10.4 mm). CONCLUSIONS: There is significant variability in the relationship between the AE and the SSC. The AE is not a consistent or reliable landmark for identifying the precise position of the SSC. Detailed preoperative information regarding the relationship between the AE, SSC, and other bony landmarks can be easily and quickly assessed using 3-D CT.

Adolescent↗

Quantification of true in vivo (application) accuracy in cranial image-guided surgery: influence of mode of patient registration.

OBJECTIVE: Very few studies have attempted to quantify the true (application) accuracy of image-guidance systems during craniotomy. This is, in part, because of the lack of millimetric intraoperative targets to allow such measurements. Few in vivo studies have compared the influence of mode of patient registration on subsequent true accuracy. METHODS: Seven modes of patient registration (anatomic landmarks, 5 or 10 adhesive fiducials, bone-implanted fiducials [Stryker-Leibinger], surface matching using 45 or 100 points over scalp convexity or nose/auditory meatus contours) were compared. Thirty patients were involved in the study. Millimetric targets (bone drill holes or deep 1-mm titanium hemoclips) were placed then localized and saved at surgery. These targets were then identified on postoperative volumetric computed tomography fused with operative data sets. Localization errors of the targets were measured for each registration on an optical image-guidance system (StealthStation). RESULTS: Only implanted cranial fiducials had a statistically significant accuracy advantage (1.7 +/- 0.7 mm). All other registrations had similar accuracies (approximately 4.0 +/- 1.7 mm) except anatomic landmarks, which were worse (4.8 +/- 1.9 mm). Calculated accuracies (root mean squared) had no predictive value for true (application) accuracies. CONCLUSION: Not surprisingly, application accuracy of image-guidance is worse without implanted cranial markers. Unexpectedly, there was no major difference in localization of deep targets between the other registrations tested in this study. Care must be taken when using image-guidance tools to consider error introduced by registration. Cranium-implanted fiducials should be considered when high accuracy and reproducibility are needed.

Anthropometry↗

Robotic virtual endoscopy: development of a multidirectional rigid endoscope.

INTRODUCTION: The use of neuroendoscopy has increased in the past 20 years. Despite an increase in the number of indications for use, novel adjuncts and modifications to existing endoscopes remain all but nonexistent. We introduce a robotic virtual endoscope with applications for neurosurgery that could serve as a novel step in the evolution of future endoscopic technologies. METHODS: Over the past 8 years, we have worked on the construction of a prototype endoscope with three degrees of freedom that was designed to allow for enhanced safety while maximizing the benefits of virtual field rendition and robotic control. We have developed a prototype to examine a cerebral ventricular model in vitro that functions via either a direct video- or computer-based interface. RESULTS: Assessment of viewing angulation with robotic feedback has verified the accuracy of the prototype. Models support the ability of the endoscope to localize regions identified via a software interface. CONCLUSION: The endoscope is a rigid virtual robotic endoscope that provides complete visual coverage of a three-dimensional space by controlling an adjustable viewing direction with three degrees of freedom.

Endoscopes↗

Use of a volumetric target for image-guided surgery.

A VIRTUAL REALITY system has been devised to superimpose a computer-generated rendering of a volumetric target to be surgically approached or resected on a real-time video image of the surgical field. A stereotactic frame is used to register the image from the video camera with the image of the target volume for accurate localization. The volumetric target is obtained from preoperative imaging studies and can be modified to adjust the intended line of resection or to avoid eloquent vascular or neural tissue. The computer-generated image is updated throughout surgery to visualize only that part of the tumor under resection so the surgeon may guide the resection along the border of the mass or intended preplanned line of resection. To date, 74 intracranial tumor resections have been performed under video virtual reality guidance. Postoperative scanning corresponds in every case with preoperative planning. This system is also designed to be adapted to frameless guidance, which can be further enhanced by the incorporation of an audible tone to signal the relationship of the tip of the resection instrument to the line of resection.

Brain Neoplasms↗

Navigation as a quality management tool in cochlear implant surgery.

This cadaver study assessed the value of navigation in cochlear implant surgery. Cochlear implantation was simulated on a cadaver using a Stryker-Leibinger navigation system and a Nucleus 24 Contour implant. A conventional surgical strategy consisting of mastoidectomy, posterior tympanotomy, and cochleostomy was performed. The navigated surgical procedure was evaluated for accuracy, reliability, reproducibility, and practicability. The technology of computer-assisted surgery is applicable in cochlear implantation and beneficial in as much as the navigation-controlled implantation constitutes a non-invasive instrument of quality management. Nevertheless, in order to keep the point accuracy below one millimeter, a referencing method using concealed bordering anatomical structures may be further needed to perform the cochleostomy reliably under the guidance of a navigation system. More reproducible reference systems are needed if navigated lateral skull base surgery is to be fully relied upon.

Cadaver↗

Navigation as a tool to visualize bone-covered hidden structures in transfrontal approaches.

A retrospective analysis of 10 patients was performed to evaluate navigation systems in extranasal frontal skull base surgery. When performing a craniotomy following a bicoronal skin incision, the surgeon has to calculate the extent of the frontal sinus to avoid unnecessary damage to the dura or mucoceles later. Due to surgical morbidity including compression of the frontal lobe, many skull base surgeons have refused to use such an approach. Malformation or bone-destruction complicates the identification of the borders and increases the risk of side-effects. Navigation systems can be an alternative for calculating the frontal sinus outlines during surgery. In the authors' surgical procedure two different navigation systems were used. Conventional surgery using the transfrontal, transbasal or subcranial approach consisting of trepanation and craniotomy were performed, while the navigated surgical procedure was evaluated. The analysis showed that computer-assisted surgery (CAS) is applicable to extranasal frontal skull base surgery. In comparison to X-ray beam-controlled craniotomy, CAS is beneficial as it constitutes a noninvasive instrument of quality management. Furthermore, the analysis indicated that under the guidance of a navigation system a precise pre-surgical simulation is available in order to perform an optimal craniotomy and reconstruction of the frontal skull base.

Adult↗

Frameless stereotactic aspiration and thrombolysis of deep intracerebral hemorrhage is associated with reduction of hemorrhage volume and neurological improvement.

INTRODUCTION: This is a phase-2 safety trial to demonstrate the ability of frameless stereotactic aspiration and thrombolysis of ICH to safely remove blood. METHODS: Patients with ICH in the deep basal ganglia and internal capsule of > 5 cc volume were consented to undergo computed tomographic imaging for frameless stereotactic guidance registration. Using the frameless stereotactic (CT) guidance, a 4-mm diameter catheter was inserted into the body of the hematoma using a frontal burr hole approach. The catheter was aspirated and then flushed with saline and aspirated to remove unclotted blood. After a confirmatory CT scan to localize the catheter, 1 mg of recombinant tissue plasminogen activator (t-PA) was infused into the clot, permitted to bathe the clot for 30 minutes, and then drained into a closed circuit collection system. t-PA was infused every 8 hours for 48 hours. A follow up CT scan was obtained at 48 hours. RESULTS: 28 patients with ICH (mean age 67.1) were admitted and underwent the procedure. Mean initial ICH volume was 54.6 cc +/-6 37.8. Mean time from onset to aspiration was 44 hours (range 7-180). Mean initial NIH Stroke scale (NIHSS) score was 24 (range 15-33). Compared with initial CT scan, there was a mean reduction of ICH volume by 77 +/-6 13% on final CT scan (p < 0.0002). Compared with initial NIHSS, the discharge mean NIHSS (16 +/- 6) was significantly improved (p < 0.001). There were no infectious, hemodynamic or neurologic complications. There were no episodes of symptomatic hemorrhagic enlargement and one case of asymptomatic bleeding along the catheter tract. CONCLUSION: Frameless stereotactic aspiration and thrombolysis (FAST) of deep spontaneous intracerebral hemorrhage is a safe therapy that is associated with reduction in ICH volume, early improvement in NIHSS and potentially could be used to improve outcome.

Adult↗

The cerefy brain atlases: continuous enhancement of the electronic talairach-tournoux brain atlas.

The Talairach-Tournoux (TT) atlas is probably the most often used brain atlas. We overview briefly the activities in developments of electronic versions of the TT atlas and focus on our more than 10-yr efforts in its continuous enhancement resulting in three main versions: TT-1997, TT-2000, and TT-2004. The recent TT-2004 version is substantially improved over the digitized print original with a higher structure parcellation, better quality and resolution of individual structures, and improved three-dimensional (3D) spatial consistency. It is also much more suitable for developing atlas-based applications owing to pure color-coding (for automatic structure labeling), contour representation (to avoid scan blocking by the overlaid atlas), and color cross-atlas consistency (for the simultaneous use of multiple atlases). We also provide a procedure for 3D spatial consistency improvement and illustrate its use. Finally, we present some of our latest atlas-assisted applications for fast and automatic interpretation of morphological, stroke, and molecular images, and discuss the future steps in TT atlas enhancement.

Algorithms↗