Interactive computer graphics: a new technology to improve judgment in rhinoplasty.

A teaching system has been developed that employs interactive computer graphics to simulate the surgical experience of rhinoplasty, allowing the surgeon to experiment within a model of nasal behavior. The ability to experiment without risk and to safely learn the laws governing nasal behavior should augment the development of surgical judgment in rhinoplasty.

Computer Graphics↗

The expert teaching system: a new method for learning rhinoplasty using interactive computer graphics.

We have developed software that employs interactive computer graphics to simulate the surgical experience of rhinoplasty by allowing the surgeon to experiment within a model of nasal behavior. For any of three preoperative noses, the surgeon can choose and see the effects of dorsal resection, modification of nasal spine or caudal septum, alar cartilage resection, osteotomy, alar wedge resection, and a variety of nasal grafts. The available choices and views total nearly 3000 images, or approximately 200 different surgical solutions. The surgeon can get textual analysis at any time or see accelerated healing to the projected nasal appearance at 1 year. We believe that the ability to experiment without risk, to safely learn the biological laws governing nasal behavior, should augment the development of surgical judgement in rhinoplasty.

Computer Graphics↗

[Intramural hematoma of the ileum complicating anticoagulant therapy].

The development of abdominal pain in the patient receiving anticoagulant therapy is more likely to pose a diagnostic dilemma. A group of intra-abdominal bleeding syndromes, which are extremely rare in patients with normal haemostasis, have been described in patients on anticoagulant therapy. Theses syndromes are of particular interest to surgeons because they simulate acute surgical conditions of the abdomen. We herein report the preoperative diagnosis of a spontaneous intramural hematoma of the small bowel by computed tomography. The authors conclude that CT should be used early in the diagnostic evaluation of abdominal pain and of acute abdomen in patients receiving anticoagulant therapy. Indications for the operative management of these patients include active bleeding, pneumoperitoneum, failure to improve with conservative management within 72 hours, worsening of symptoms, and uncertain diagnosis.

Acenocoumarol↗

Adaptation and remodeling of the mandibular condyle following vertical ramus osteotomy in dogs.

This experiment investigated the effects of vertical ramus osteotomy (VRO) on normal mandibular condyles and those altered surgically to simulate trauma to the articular surface. Four dogs that received unilateral vertical ramus osteotomy to reposition the condyle downward and forward responded with progressive remodeling of the articular cartilage. A second group of four dogs that had grooves cut into the articular surfaces of both condyles showed more rapid healing on the side receiving VRO. In a third group (n = 4), vertical ramus osteotomy appeared to protect the articular cartilage from regressive remodeling after extraction of the molar teeth and prevent decreased vertical dimension of occlusion. The articular cartilage on the side with the vertical ramus osteotomy remained healthy, while the untreated side developed a narrower joint space and showed histologic evidence of thinning and degeneration of the fibrocartilage and increased density of the subchondral bone.

Adaptation, Physiological↗

[Effects of late suturing and of various locations of skin wounds on wound healing in young and old rats].

The healing of six-day-old cutaneous wounds under different conditions had been evaluated in rats. Wounds situated along the direction of cutaneous splitting displayed a slightly better healing than the other ones. In the wounds of young rats proliferation of fibroblast occurred earlier, but the more pronounced exsudative component persisted for a longer period. Regeneration of the epidermis preceded healing in the corium in all cases. All the differences mentioned disappeared when the wound was sutured two hours after the lesion had been produced, under conditions simulating the surgical procedure. The wound edges remained free of any substantial reaction. The regenerated epidermis became easily disrupted and the wound opened widely even when the histological processing was very careful. The lesioned connective tissue of the corium remained covered with fibrin.

Age Factors↗

The simulated operating theatre: comprehensive training for surgical teams.

Surgical excellence is traditionally defined in terms of technical performance, with little regard for the importance of interpersonal communication and leadership skills. Studies in the aviation industry have stressed the role of human factors in causing error and, in an attempt to reduce the occurrence of adverse events, led to the organisation of simulation based training scenarios. Similar strategies have recently been employed for the surgical team with the development of a simulated operating theatre project. This enables technical and non-technical performance of the surgeon and circulating staff to be assessed by experts situated in an adjacent control room, and provides an opportunity for constructive feedback. The scenarios have good face validity and junior surgeons can benefit from the process of learning new technical skills in a realistic environment. The effect of external influences such as distractions, new technology, or a crisis scenario can also be defined, with the ultimate aim of reducing the number of adverse events arising in the real operating room.

Clinical Competence↗

Biomechanical basis of optimal scoliosis surgical correction.

For an optimal approach to surgical correction of scoliosis, it was deemed desirable to biomechanically simulate the set of corrective forces applied by alternative internal fixation systems, so as to determine and apply the internal fixation system producing the best correction under safe levels of forces applied by the fixation systems to the spinal structures. To this end, we have developed, and presented here, (1) a spinal finite-element model relating the applied corrective forces to the corrected spinal configurations, (2) a method for determining the stiffness of the patient's spine prior to surgery, (3) computerized finite-element analysis simulation of alternative internal correction-fixation systems, so as to determine the most efficacious system, (4) instrumentations for surgically implementing the recommendations of the surgical simulation analysis and (5) comparisons of the model-simulated and surgically-obtained corrected spinal configurations. These procedures together constitute the biomechanical foundations of scoliosis surgical correction.

Biomechanical Phenomena↗

Surgical education and Internet-based simulation: The World Virtual University.

The new means and modalities of communication and information technologies have significantly revolutionized access to surgical education. The introduction of the Internet information highway into mainstream clinical practice as an information sharing medium offers a wide range of opportunities to healthcare professionals. High-speed Internet broadcasting allows the display of high-quality full-screen videos. Access to surgical procedures through the Internet already plays a major role in continuing medical education nowadays and will undoubtedly be gaining grounds in the future. WebSurg.com, the World Virtual University, a web-based surgical university, is dedicated to minimally invasive laparoscopic surgery. Using brand-new multimedia data, the electronic university provides thorough descriptions of over 150 procedures in minimal access surgery and 265 videos of surgical interventions. Such a teaching tool recreates all the prerequisites and requirements of a traditional School of Medicine, incorporating the manifold standpoints of world-renowned experts about specific topics and hands-on hints in various surgical specialities. Following the evolution of technologies, recent advances have made it possible to display items of Websurg.com on handheld devices (personal data/digital assistance also known as PDAs, Pocket PCs, and smart phones). Integrating all these elements into a unique World Virtual University, Websurg.com epitomizes the concept of a unified academic center providing teaching and tutorials administered by international experts. The Internet assuredly contributes to the worldwide diffusion of scientific information in an easy and user-friendly way.

Journal Article↗

Surgical dexterity after a 'night out on the town'.

BACKGROUND: This study examines the effect of alcohol intake on surgical dexterity immediately after and the morning after alcohol intake and minimal sleep deprivation by simulating a typical night out on the town. METHODS: Five surgeons (all men, aged 31-40 years) were trained on a laparoscopic surgical simulator (minimally invasive surgical trainer-virtual reality) to reach a desired standard of performance. Three experimental settings were used: (i) a control night with no alcohol and full night's sleep; (ii) a sham night out (sleep deprived) without alcohol; and (iii) a night out with alcohol ad libitum. The parameters recorded were the average time taken to carry out a task, error rate, average diathermy time and diathermy (damage) time to main object. Comparisons between baseline readings, those in the middle of the night and those of the following morning were made by applying ANOVA methods after logarithmic transformation of the data. RESULTS: The candidates consumed, on average, 10.33 units (range, 6-15 units) of alcohol and had 0.86% (range, 0.71-1.1%) of breath alcohol levels and an average of 3.75 h (range, 3-5 h) of sleep after a typical night out. The morning-after breath alcohol levels were 0%. There was significant deterioration in performance, as measured by all indicators, immediately after alcohol consumption. The adverse effects on time taken to complete the task and total diathermy time were still apparent the morning after. The sham night out appeared to affect only 'time parameters'. No significant changes in performance were seen in the control setting. CONCLUSION: Both alcohol consumption and sleep deprivation adversely affect the ability to carry out surgical procedures. Our simulation study suggests that the adverse effects of alcohol intake persist the following morning.

Alcohol Drinking↗

[A rapid prototype fabrication method of dental splint based on 3D simulation and technology].

The conventional design and fabrication of the dental splint (in orthognathic surgery) is based on the preoperative planning and model surgery so this process is of low precision and efficiency. In order to solve the problems and be up to the trend of computer-assisted surgery, we have developed a novel method to design and fabricate the dental splint--computer-generated dental splint, which is based on three-dimensional model simulation and rapid prototype technology. After the surgical planning and simulation of 3D model, we can modify the model to be superior in chewing action (functional) and overall facial appearance (aesthetic). Then, through the Boolean operation of the dental splint blank and the maxillofacial bone model the model of dental splint is formed. At last, the dental splint model is fabricated through rapid prototype machine and applied in clinic. The result indicates that, with the use of this method, the surgical precision and efficiency are improved.

Computer-Aided Design↗

Dynamic simulation using a graphical programming language.

A power oscillator, suitable for energizing an ultrasonic surgical cutter was simulated using a graphical programming language. The simulation included a model of the amplitude control system as well as the ultrasonic actuator. In addition, those elements which existed in a practical oscillator and were typically obscure to the design requirements were identified, simulated and discussed.

Computer Simulation↗

A novel drill set for the enhancement and assessment of robotic surgical performance.

BACKGROUND: There currently exist several training modules to improve performance during video-assisted surgery. The unique characteristics of robotic surgery make these platforms an inadequate environment for the development and assessment of robotic surgical performance. METHODS: Expert surgeons (n=4) (>50 clinical robotic procedures and >2 years of clinical robotic experience) were compared to novice surgeons (n=17) (<5 clinical cases and limited laboratory experience) using the da Vinci Surgical System. Seven drills were designed to simulate clinical robotic surgical tasks. Performance score was calculated by the equation Time to Completion + (minor error) x 5 + (major error) x 10. The Robotic Learning Curve (RLC) was expressed as a trend line of the performance scores corresponding to each repeated drill. RESULTS: Performance scores for experts were better than novices in all 7 drills (p<0.05). The RLC for novices reflected an improvement in scores (p<0.05). In contrast, experts demonstrated a flat RLC for 6 drills and an improvement in one drill (p=0.027). CONCLUSION: This new drill set provides a framework for performance assessment during robotic surgery. The inclusion of particular drills and their role in training robotic surgeons of the future awaits larger validation studies.

Clinical Competence↗

Virtual simulator as a training tool for endonasal surgery.

BACKGROUND: Virtual simulation could be an important tool for medical and surgical training as well as education. The efficacy of a simulator for endoscopic nasal procedures in a training program was evaluated. METHODS: The simulator is a medical and scientific tool for visualizing and interacting with three-dimensional volumetric data. Twenty endonasal operations with chronic rhinosinusitis were simulated by two 3rd-year residents and proctored by the senior surgeon 1 day before the actual surgery was performed with an endoscope and computer-aided surgery. A questionnaire was established. RESULTS: The surgical simulator may provide a better understanding of the morphology of the paranasal sinuses with a minor impact on performance of endoscopy by junior residents. Disadvantages identified were time consumption, absence of force feedback, and subtle handling of the joysticks. CONCLUSION: The virtual simulator allows the nonendoscopically nasal trained surgeon to understand and practice endonasal surgery using real-patient data but failed to make an impact on operating room performance. Furthermore, the simulator's effectiveness was limited by the absence of force feedback, subtle handling of the joysticks, and considerable time consumption.

Clinical Competence↗

Virtual reality and women's health: a breast biopsy system.

Minimally invasive procedures are becoming much more common in surgical practice because of the many advantages for patient comfort and convenience, and improved surgical access. However some of the major problems leading to occasional surgical errors with this minimal access method are restricted vision, limited sense of touch, difficulties in identification in 3D space of the position of the instrument tips, and their handling during delicate, short-distance movements toward the surgical target area. These factors emphasize the need for computer simulated training in surgical manipulations and procedures in preparation for conducting them in patients. The key new feature of our proof-of-concept training simulator is a preventive mechanism that serves at least two functions. As the surgical target (or a critical structure) is approached, a haptically generated preventive force forewarns the surgeon, making it possible to abort those maneuvers that may lead to adverse results. By announcing a potential collision of a virtual instrument tip with a surgical target, the time used for searching for the target is shortened, and the haptic signal minimizes the potential of tissue damage. This real-time, interactive, virtual reality based, haptic breast biopsy-training simulation is a PC/NT based multitasking, multithreading system. It is based upon an advanced force feedback device. The system monitors and indirectly guides the surgeon's movements, while providing high fidelity visual and force feedback cues as the area of surgical interest is approached. Our first application is with human breast.

Algorithms↗