PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Tooth Apex”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

The effectiveness of increased apical enlargement in reducing intracanal bacteria.

It has been suggested that the apical portion of a root canal is not adequately disinfected by typical instrumentation regimens. The purpose of this study was to determine whether instrumentation to sizes larger than typically used would more effectively remove culturable bacteria from the canal. Forty patients with clinical and radiographic evidence of apical periodontitis were recruited from the endodontic clinic. Mandibular cuspids (n = 2), bicuspids (n = 11), and molars (mesial roots) (n = 27) were selected for the study. Bacterial sampling was performed upon access and after each of two consecutive instrumentations. The first instrumentation utilized 1% NaOCI and 0.04 taper ProFile rotary files. The cuspid and bicuspid canals were instrumented to a #8 size and the molar canals to a #7 size. The second instrumentation utilized LightSpeed files and 1% NaOCl irrigation for further enlargement of the apical third. Typically, molars were instrumented to size 60 and cuspid/bicuspid canals to size 80. Our findings show that 100% of the cuspid/bicuspid canals and 81.5% of the molar canals were rendered bacteria-free after the first instrumentation sizes. The molar results improved to 89% after the second instrumentation. Of the (59.3%) molar mesial canals without a clinically detectable communication, 93% were rendered bacteria-free with the first instrumentation. Using a Wilcoxon rank sum test, statistically significant differences (p < 0.0001) were found between the initial sample and the samples after the first and second instrumentations. The differences between the samples that followed the two instrumentation regimens were not significant (p = 0.0617). It is concluded that simple root canal systems (without multiple canal communications) may be rendered bacteria-free when preparation of this type is utilized.

Bacteria↗

The effect of irrigation with doxycycline or citric acid on leakage and osseous wound healing.

This study investigated the effect of doxycycline irrigation on wound healing and the apical seal of three filling materials. Part 1: 220 extracted teeth received root canal therapy followed by root resection (2 mm) and ultrasonic root end preparations (3 mm). Groups of 20 were irrigated with saline, citric acid, or doxycycline and filled with amalgam, Super EBA, or MTA. Leakage was measured (mm) after decalcification and clearing. Part 2: two defects were made on each side of the mandible of 10 New Zealand rabbits. On each side, one defect was irrigated with saline and one with either citric acid or doxycycline. The animals were killed in groups of five at 9 and 18 days. Sections of each defect were stained with hematoxylin and eosin for evaluation of healing and bone fill. Super EBA and MTA leaked significantly less than amalgam, regardless of irrigant. Leakage after irrigation with doxycycline compared to citric acid or saline was not significantly different for Super EBA or MTA but was lower for amalgam. There was no significant difference in healing or bone fill among irrigants at 9 or 18 days.

Aluminum Compounds↗

The effect of chlorhexidine gluconate as an endodontic irrigant on the apical seal: long-term results.

The purpose of this study was to determine whether chlorhexidine gluconate (0.12%), used as an endodontic irrigating solution, would affect the apical seal of three root canal cements. One hundred, extracted, human, single-canal teeth were divided into 9 experimental groups of 10 teeth each, in addition to a positive and negative control group of 5 teeth each. The teeth were decoronated at the level of the CEJ, accessed, instrumented to a Master apical file #50, irrigated with either sterile saline, 5.25% NaOCl, or 0.12% chlorhexidine gluconate, and dried using paper points. Obturation was accomplished using lateral condensation and one of three endodontic sealers: Roth's 811, AH 26, or Sealapex. Postobturation apical leakage was measured at 270- and 360-day observation periods using the fluid filtration method. Using the mixed-model repeated-measures ANOVA test with Tukey's honest significance difference multiple comparison procedure, the results showed the saline-Sealapex combination had significantly more leakage (p < 0.05) than either the Peridex-Sealapex or saline-Roth's combinations at 270 days. No other significant differences were noted between any sealer-irrigant combination at 270 days. The saline-Sealapex combination had significantly more leakage than the saline-Roth's combination at 360 days. No other significant differences were noted at 360 days. Under the conditions of this study, chlorhexidine gluconate irrigant did not adversely affect the apical seal of three root canal cements at 270 and 360 days.

Analysis of Variance↗

Shearing bond strength of endodontic sealers to gutta-percha.

Strength of the bond of root canal sealers to gutta-percha seems to be an important property for maintaining the integrity of the apical seal. In the few studies published, different models and assessment methods were used. The purpose of our study was to adapt an effective and easily reproducible model and to test it on nine contemporary commercially available endodontic sealers. Gutta-percha disks with a diameter of 10 mm and thickness of 2 mm were prepared by warming gutta-percha cones and then fixed with plaster in 1-inch phenolic rings. Five-millimeter long sections of polyethylene tubing, filled with freshly mixed sealer, were placed on the gutta-percha and tested for shearing bond strength after setting. A custom-made holder was attached to the rings and placed in an Instron machine, which was activated at a cross-arm speed of 0.5 mm per minute. The bond strength ranged from 0 MPa to 6.4 MPa. The sealers were ranked, and those that did not differ statistically in their bond strength were grouped together. This model provides a simple and reproducible means for measuring the in vitro bond strength of endodontic sealers.

Adhesiveness↗

Apical leakage of four endodontic sealers.

The purpose of this study was to evaluate the sealing properties of four root canal sealers. Forty-eight maxillary central incisors were instrumented with Profile rotary instruments. They were randomly divided into four groups (n = 12) and filled using lateral condensation with one of the four sealers: Sealapex, Pulp Canal Sealer, AH 26, and Ketac-Endo. The apical leakage was measured with a fluid filtration method and expressed as L s(-1) KPa(-1). The teeth filled with Sealapex displayed a higher apical leakage (8.42 +/- 4.2 10(-11) L s(-1) KPa(-1)) than those filled with AH 26 (2.10 +/- 1.39 10(-11) L s(-1) KPa(-1)), Pulp Canal Sealer (0.17 +/- 0.09 10(-11) L s(-1) KPa(-1)) or Ketac-Endo (0.32 +/- 0.24 10(-1) L s(-1) KPa(-1)) (p < 0.01). No statistically significant difference was found among AH 26, Pulp Canal Sealer, and Ketac-Endo. No correlation was found between the sealing efficiency of the four sealers and their adhesive properties recorded in a previous study.

Adhesiveness↗

The cemento-dentino-canal junction, the apical foramen, and the apical constriction: evaluation by optical microscopy.

The cemento-dentino-canal junction, the apical constriction, and the apical foramen are the principal reference points used to determine the apical limit for instrumentation and root canal filling. For a better understanding of these structures, the objective of this study was to evaluate histologically the localization of the cemento-dentino-canal junction and the diameters of the apical foramen and root canal at the cemento-dentino-canal junction. Eighteen anterior maxillary teeth (canines, central, and lateral incisors) were used, from which 269 histological sections were obtained and evaluated by optical microscopy. The results indicated that the longest extension of the cementum into the root canal was observed in the canines, this value decreasing in the lateral incisors, and even more so in the central incisors. The widest diameter of the apical foramen corresponded to the lateral incisors, followed by the canines and the central incisors. The diameter of the root canal at the cemento-dentino-canal junction was greatest in the canines and lowest in the central and lateral incisors. Great variability was observed in the measurements of the extension of the cementum into the root canal. AQ: 1.

Adult↗

Comparison of apical transportation in four Ni-Ti rotary instrumentation techniques.

A new radiographic technique was used to compare apical transportation in four Ni-Ti rotary instrumentation sequences. Mesiobuccal canals of 60 extracted mandibular molars were randomly divided into four groups. Groups 1 and 3 were instrumented by crown-down and groups 2 and 4 by step-back technique with 0.06 ProFiles series 29 to size 6. In groups 3 and 4 Greater Taper files were first used in a crown-down manner. The central axes of initial and final instruments were radiographically superimposed to measure loss of working length (WL) and transportation at 0, 0.5, 1, 3, and 5 mm from WL. ANOVA test showed no significant differences among groups regarding degree of transportation or loss of WL. Transportation was negatively correlated with radius of curvature at 0.5 and 5 mm from WL. The results indicate that the operational sequence of ProFiles or preinstrumentation with GT files has no effect on degree of transportation and loss of WL.

Analysis of Variance↗

Reliability of the dye penetration studies.

The purpose of this study was to compare the classical dye-penetration method to a dye-extraction method, with a fluid-filtration method as control. Forty teeth were prepared with a ProFile device and divided into four groups (n = 10 per group) according to the sealer used for the lateral condensation: Pulp Canal Sealer, Sealapex, AH Plus, and Ketac-Endo. The apical seal was evaluated on the same teeth with all three methods, successively: a fluid-filtration method, a dye-penetration method with 2% methylene blue, and a new method where the roots were dissolved in 65% nitric acid to extract the methylene blue before reading the absorbance of the solution. The classical dye penetration did not show any difference among the sealers and showed no correlation with the two other techniques. The fluid filtration (p < 0.01) and the dye extraction (p < 0.01) showed that Sealapex displayed the highest apical leakage. The correlation between the results obtained with these two methods was significant (p = 0.001 and r = 0.7). This study showed the limitation of the classical dye-penetration studies and that the dye-extraction, i.e. dissolution, method gave the same results as fluid filtration but saved much laboratory time.

Analysis of Variance↗

Patient safety during endodontic therapy using current technology: a case report.

It is an accepted safety practice to take precautions during endodontic treatment to prevent aspiration or swallowing of instruments (1). The placement of a rubber dam is considered the standard of care (2, 3). With the advent of new endodontic devices, new safety challenges have arisen and must be considered in addition to the placement of a rubber dam. A case report is presented that emphasizes the importance of patient safety and suggests precautions to prevent any safety-related mishaps during treatment.

Dental Instruments↗

Anesthetic efficacy of the supplemental X-tip intraosseous injection in patients with irreversible pulpitis.

The purpose of this study was to determine the anesthetic efficacy of the supplemental intraosseous injection, using the X-tip system in an apical location, in mandibular posterior teeth diagnosed with irreversible pulpitis when the conventional inferior alveolar nerve block failed. Thirty-three emergency patients, diagnosed with irreversible pulpitis of a mandibular posterior tooth, received an inferior alveolar nerve block and had moderate-to-severe pain on endodontic access. The X-tip system was used to administer 1.8 ml of 2% lidocaine with 1:100,000 epinephrine. The X-tip injection site was 3- to 7-mm apical to the mucogingival junction of the affected tooth. Success of the X-tip intraosseous injection was defined as none or mild pain on endodontic access or initial instrumentation. The results of this study demonstrated that 6 of 33 (18%) X-tip injections resulted in backflow of anesthetic solution into the oral cavity; none were successful in obtaining anesthesia. Twenty-seven of the remaining 33 X-tip injections (82%) were successful. We conclude that when the inferior alveolar nerve block fails to provide profound pulpal anesthesia, the X-tip system, when used in an apical location and when there was no backflow of the anesthetic solution into the oral cavity, was successful in achieving pulpal anesthesia in mandibular posterior teeth of patients presenting with irreversible pulpitis.

Adult↗

Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: an experimental study.

The use of nickel-titanium rotary instruments in endodontic practice is increasing. One frequently mentioned problem is fracture of an instrument within the root canal. To date, there is no consistently safe and successful technique for removing these fractured instruments. This study evaluates the use of an ultrasonic technique to remove fractured rotary nickel-titanium instruments from narrow, curved canals in both simulated (resin blocks) and mesiolingual canals of extracted mandibular first molars. A technique using ultrasonic tips, combined with the creation of a "staging platform" and the use of the dental operating microscope, was consistently successful and safe at removing fractured rotary nickel-titanium instruments from curved root canals, when some part of the fractured instrument segment was located in the straight portion of the canal. When the fractured instrument segment was located entirely around the curve, the success rate was significantly decreased and major canal damage often occurred.

Analysis of Variance↗

Comparison instrumentation reamers and files versus a flat-sided design of conventional noninterrupted, flat-sided design.

The in vitro study measured the time required to instrument and shape canals by conventional reamers and files compared with a newly introduced reamer and file system. This experiment was divided into four groups with 10 block samples for each group. The results of instrumentation time demonstrate that the noninterrupted flat-sided design (EZ-Fill SafeSider reamers) produced the fastest times for comparably shaped canals because of reduced engagement of the instrument with the walls of the canal compared with conventional instruments. The conventional designs for both reamers and files result in increased instrumentation time compared with their EZ-Fill SafeSider counterparts.

Acrylic Resins↗

MTA for obturation of mandibular central incisors with open apices: case report.

The case reported demonstrates dramatic healing of the periapical region of retreated root canals with open apices by the successful use of mineral trioxide aggregate (MTA). Unsuccessful conventional root canal therapy for the mandibular central incisors had been followed by surgical treatment. The severely damaged root canals were obturated using MTA in anticipation of the formation of artificial apical plugs. The treated teeth were asymptomatic, and radiographic examination demonstrated apparent regeneration of periradicular tissue 2 years after the obturation. MTA can be considered a very effective material to promote regeneration of apical tissue, even in teeth with large open apices.

Aluminum Compounds↗

Apical extrusion of thermoplasticized obturating material in canals instrumented with Profile 0.06 or Profile GT.

The purpose of this in vitro study was to compare the extrusion of thermoplacticized gutta-percha in teeth instrumented with Profile 0.06 or Profile GT, and obturated with Thermafil Plus and Thermafil GT, respectively. A total of 120, extracted, human maxillary central incisors were divided into four equal groups. Group 1 was instrumented with Profile 0.06 and obturated with Thermafil Plus. Group 2 was instrumented with Profile 0.06 and obturated using warm vertical condensation (negative control). Group 3 was instrumented with Profile GT and obturated with Thermafil GT. Group 4 was instrumented with Profile GT and obturated like Group 2 (negative control). Extrusion was graded as present or absent. Results found 9 of 30 extruded for group 1, 1 of 30 for group 2, 15 of 30 for group 3, and 2 of 30 for group 4. The results suggest that, in vitro, Thermafil GT may be more prone to extruding gutta-percha past the apical foramen than Thermafil Plus.

Chi-Square Distribution↗

Evaluation of apical filling after warm vertical gutta-percha compaction using different procedures.

The aim of the present study was to evaluate the quality of endodontic sealing in the apical 4 mm of narrow and curved canals using different filling techniques. Human teeth were selected and assigned to four different techniques: group A, Schilder's warm vertical condensation; group B, Schilder's technique modified by using an electric heater; group C, Schilder's technique modified by compaction of the apical tract at body temperature; and group D, a modified vertical compaction with apical back-filling. A dye penetration test was performed, and specimens of group D showed increased apical sealing and reduced extension of voids. The use of the vertical compaction with apical back-filling technique allowed the creation of an effective apical plug and an excellent adaptation of back-filling to apical gutta-percha and to root canal walls.

Analysis of Variance↗

Effect of 2% chlorhexidine gel as an intracanal medication on the apical seal of the root-canal system.

The purpose of this study was to determine what effect intracanal medications might have on the apical seal of the root-canal system. Forty-two teeth were cleaned and shaped in a crown-down manner to a size #50 K-file. The teeth were divided into three groups: (A) immediate obturation; (B) intracanal placement of calcium hydroxide placed for 14 days; and (C) 2% chlorhexidine gel placed for 14 days. After 14 days, these materials were removed using copious irrigation and obturation was completed on groups B and C. Obturation was performed using the continuous wave of condensation technique using AH Plus sealer in all groups. Leakage was evaluated 60 days after obturation by using a fluid-filtration device. Using the one-way ANOVA test, there was no statistically significant difference in leakage between the three groups. Under the conditions of this study, 2% chlorhexidine gel and calcium hydroxide paste did not adversely affect the apical seal of the root-canal system.

Analysis of Variance↗

Identification of resected root-end dentinal cracks: a comparative study of transillumination and dyes.

The dilemma of diagnosing and possibly treating dentinal cracks continues to present a challenge in endodontics. The purpose of this in vitro study was to compare the effectiveness of transillumination and dyes in identifying root-end dentinal cracks. Fifty maxillary central incisors were decoronated, and the canals were instrumented to an ISO size 50 at the working length. The apical 3 mm of the roots was resected, and cracks were artificially created in the apical dentin. Four independent examiners evaluated the root ends at x8 magnification with a surgical operating microscope using transillumination (group 1), sodium fluorescein dye (group 2), caries detect dye (group 3), methylene blue dye (group 4), and methylene blue plus transillumination (group 5). The examiners' ability to identify root ends correctly with and without cracks was analyzed by comparing the data with the predetermined standard (cracked and noncracked) using logistic regression analysis. All techniques used were shown to be more effective than random chance at diagnosing cracks. The areas under the curve of the different techniques were as follows: transillumination, 0.81 (95% confidence interval [CI], 0.69-0.93); sodium fluorescein, 0.72 (95% CI, 0.58-0.86); caries detector, 0.76 (95% CI, 0.63-0.89); methylene blue, 0.70 (95% CI, 0.55-0.84); and methylene blue plus transillumination, 0.82 (95% CI, 0.70-0.94). Thus, the crack assessment techniques that gave the best discrimination between cracked and noncracked specimens, regardless of rater, was methylene blue plus transillumination. This study emphasizes the usefulness of transillumination along with magnification in detecting dentinal cracks.

Area Under Curve↗

Apical diffusion of calcium hydroxide in an in vitro model.

An in vitro agar model was developed to study the effect of intracanal medicaments on periapical tissues and was used to study the diffusion of three calcium hydroxide (Ca(OH)2) medicaments of varying viscosity through simulated root canals with various sizes of apical foramina. Experimental medicaments were added to pipette tips used to represent tooth roots, which were fixed in syringes containing brain heart infusion agar and calcium-reactive dye. OH and Ca concentrations were measured in the agar at 30 minutes and 24 hours. Ca concentration and pH increased with larger aperture sizes, and higher pH and Ca diffusion was produced by a 10% Ca(OH)2 solution than was produced by Pulpdent or a Ca(OH)2 paste. The results suggest that the properties of the Ca(OH)2-containing vehicle could affect the action of the medicament in the periapical tissues.

Analysis of Variance↗