Fast biosensor immunoassays for the detection of cows' milk in the milk of ewes and goats.

Two monoclonal antibodies (MAb) raised against bovine kappa-casein were developed and applied in an automated optical biosensor (Biacore 3000) to create easy and fast direct and inhibition biosensor immunoassays (BIA) for the detection of cows' milk in the milk of ewes and goats. With both assay formats, low limits of detection (<01%) and fast run times (around 5 min) were obtained. For sample preparation, milk was diluted in buffer (direct assay) or in an antibody-containing buffer (inhibition assay) only. For quantitative analysis, calibrants of cows' milk in ewes' or goats' milk were used. Advantages of the direct BIA are: the single reagent format (biosensor chip immobilized antibodies only); the use of small amounts of antibodies (2 microg for >350 tests); and the wide measurement range (0.1 to 10% cows' milk). Despite these advantages, the inhibition BIA (using kappa-casein immobilized on the chip) was preferred because of the possible application of non-purified Mab, the higher responses, the higher sensitivity at relevant low percentages of cows' milk and its robustness (>800 cycles per chip).

Animals↗

A biosensor for theophylline based on fluorescence detection of ligand-induced hammerhead ribozyme cleavage.

Recently, Breaker and coworkers engineered hammerhead ribozymes that rearrange from a catalytically inactive to an active conformation upon allosteric binding of a specific ligand. To monitor cleavage activity in real time, we have coupled a donor-acceptor fluorophore pair to the termini of the substrate RNA of such a hammerhead ribozyme, modified to cleave in trans in the presence of the bronchodilator theophylline. In the intact substrate, the fluorophores interact by fluorescence resonance energy transfer (FRET). The specific FRET signal breaks down as the effector ligand binds, the substrate is cleaved, and the products dissociate, with a rate constant dependent on the concentration of the ligand. Our biosensor cleaves substrate at 0.46 min(-1) in 1 mM theophylline and 0.04 min(-1) without effector, and discriminates against caffeine, a structural relative of theophylline. We have measured the theophylline-dependence profile of this biosensor, showing that concentrations as low as 1 microM can be distinguished from background. To probe the mechanism of allosteric regulation, a single nucleotide in the communication domain between the catalytic and ligand-binding domains was mutated to destabilize the inactive conformation of the ribozyme. As predicted, this mutant shows the same activity (0.3 min(-1)) in the presence and absence of theophylline. Additionally, time-resolved FRET measurements on the biosensor ribozyme in complex with a noncleavable substrate analog reveal no significant changes in fluorophore distance distribution upon binding of effector.

Base Pairing↗

Biosensors based on membrane-bound enzymes immobilized in a 5-(octyldithio)-2-nitrobenzoic acid layer on gold electrodes.

Gold electrodes were modified through chemisorption of 5-(octyldithio)-2-nitrobenzoic acid (ODTNB). ODTNB includes a long chain in a short-length thio acid, providing a heterogeneous-like alkanethiol layer after adsorption on gold electrodes. Membrane-bound enzymes, in particular D-fructose dehydrogenase (FDH), D-gluconate dehydrogenase (GADH), and L-lactic dehydrogenase (cytochrome b2) (Cyb2), were immobilized onto ODTNB-modified gold electrodes simply by adsorption. The short-length thio acid may provide electrostatic interactions with enzyme surface charges, while the alkanethiolate enables hydrophobic interaction with the largely lipophilic, membrane-bound enzymes. The immobilization of FDH, GADH, and Cyb2 onto ODTNB-modified gold surfaces has been studied with the quartz crystal microbalance (QCM). Spectrophotometric and electrochemical assays indicate that the immobilized enzyme retains its enzymatic activity after immobilization onto the ODTNB-modified gold surface. The amount of immobilized (and active) enzyme was estimated from QCM to be of the order of 2.5 x 10(-12)-5.3 x 10(-12) mol x cm(-2). A fructose biosensor was developed, making use of a gold surface modified with ODTNB and fructose dehydrogenase, employing hydroxymethylferrocene as a mediator in solution. Calibration curves exhibited a linear relation between the biosensor response and the substrate concentration up to 0.7 mM. Statistical analysis gave an excellent linear correlation (r = 0.9993) and a sensitivity of 6.1 mM(-1) fructose. The biosensor shows a significant stable catalytic current for at least 25 days.

Biosensing Techniques↗

Amperometric quantification of polar organic solvents based on a tyrosinase biosensor.

A novel amperometric biosensor for quantification of the electrochemically inert polar organic solvents based on tyrosinase electrode was preliminarily reported. The biosensor was fabricated by simply syringing an aqueous solution of tyrosinase/PVAVP (PVAVP: copolymer of poly(vinyl alcohol) grafting with 4-vinylpyridine) onto glassy carbon electrode surface followed by drying the modified electrode at +4 degrees C in a refrigerator. The current generated from electrochemical reduction of quinone is a probe signal. The biosensor can be used for quantification of polar organic solvents, and its mechanism was characterized with in situ steady-state amperometry-quartz crystal microbalance experiments. The detection limit, sensitivity, and dynamic range for certain organic solvents are dependent on the kind and concentration of the substrate probe and the hydrophobicity of the immobilization matrix. The response time for all the tested organic solvents is less than 2 min.

Acetonitriles↗

Potentiometric biosensor employing catalytic antibodies as the molecular recognition element.

Catalytic antibodies are introduced as an important new class of biomolecules for molecular recognition in biosensors in which the binding sites are continually regenerated by the catalytic reaction of the substrate. Consequently, molecular recognition by catalytic antibodies can yield reversible immunoblosensors. In this example, a prototype potentiometric biosensor is described in which a micro-pH electrode is modified with a catalytic antibody that catalyzes the hydrolysis of phenyl acetate, producing hydrogen ions that can be monitored by the electrode. The reversible response is linear with the log of substrate concentration over a range of 20-500 microM with a detection limit of 5 microM under the conditions of this study. Alternative applications of catalytic antibodies in other biosensor configurations are discussed.

Antibodies, Monoclonal↗

Adaptation of a surface plasmon resonance biosensor with microfluidics for use with small sample volumes and long contact times.

The efficient delivery of sample to surface-immobilized sites is a key element in biosensing. For a surface plasmon resonance (SPR) biosensor, this has been addressed by constant flow through a microfluidic system with a sample injection loop (Sjölander, S.; Urbaniczky, C. Anal. Chem. 1991, 63, 2338-2345). The present study describes an alternative mode of sample delivery without constant unidirectional flow. It was implemented on a commercial Biacore X SPR biosensor equipped with a microfluidic cartridge, but with the fluidic handling performed by an externally computer-controlled syringe pump. We demonstrate that sample volumes as low as 2 microL can be reproducibly positioned to cover the sensor surfaces, manipulated in a serial fashion, efficiently mixed by applying an oscillatory flow pattern, and fully recovered. Compared to the traditional continuous unidirectional flow configuration, we found very similar kinetic responses at high analyte concentrations and slightly slower responses at low concentrations, most likely due to depletion of analyte from the small sample volumes due to surface binding. With the antibody-antigen systems tested, binding parameters were obtained that are generally within 10% of those from conventional experiments. In the new configuration, biosensor experiments can be conducted without the usual constraints in the surface contact time that are correlated with sample volume and mass transport rate. This can translate to improved detection limits for slow reactions and can facilitate kinetic and thermodynamic binding studies.

Biosensing Techniques↗

Fluidics cube for biosensor miniaturization.

To create a small, portable, fully automated biosensor, a compact means of fluid handling is required. We designed, manufactured, and tested a "fluidics cube" for such a purpose. This cube, made of thermoplastic, contains reservoirs and channels for liquid samples and reagents and operates without the use of any internal valves or meters; it is a passive fluid circuit that relies on pressure relief vents to control fluid movement. We demonstrate the ability of pressure relief vents to control fluid movement and show how to simply manufacture or modify the cube. Combined with the planar array biosensor developed at the Naval Research Laboratory, it brings us one step closer to realizing our goal of a handheld biosensor capable of analyzing multiple samples for multiple analytes.

Biosensing Techniques↗

A planar amperometric creatinine biosensor employing an insoluble oxidizing agent for removing redox-active interferences.

A planar microchip-based creatinine biosensor employing an oxidizing layer (e.g., a PbO2 film), where interfering redox-active substances are broken (i.e., oxidized) to redox-inactive products, was developed to facilitate the microfabrication of the sensor and to provide improved, reliable determination of creatinine in physiological samples. The feasibility of using hydrophilic polyurethanes in permselective barrier membranes for creatinine biosensors and the effect of adding a silanizing agent (adhesion promoter) on the sensor performance (e.g., sensitivity, stability, and lifetime) are described. The proposed creatinine microsensor with a three-layer configuration, i.e., enzyme, protecting, and oxidizing layers, exhibits good electrochemical performance in terms of response time (t95% = 98 s at 100-->200 microM creatinine change), linearity (1-1000 microM, r = 0.9997), detection limit (0.8 microM), and lifetime (approximately 35 days). The creatinine biosensor devised in a differential sensing arrangement that compensates the erroneous results from creatine is considered to be suitable for assay of serum specimens.

Biosensing Techniques↗

Biosensor for asparagine using a thermostable recombinant asparaginase from Archaeoglobus fulgidus.

Asparaginase from the hyperthermophilic microorganism Archaeoglobus fulgidus was cloned and expressed in Escherichia coli as a fusion protein with a polyhistidine tail. After heat treatment to denature most of the native E. coli proteins, the enzyme was purified by an immobilized metal ion affinity chromatography method. The activity of the enzyme was determined by monitoring the change in ammonium concentration in solution. It was found that the enzyme is thermostable at temperatures as high as 85 degrees C. The KM for L-asparagine was 8 x 10(-5) and 5 x 10(-6) M at 37 and 70 degrees C, respectively. The catalytic activity for L-asparagine was 5-fold higher than for D-asparagine. The enzyme was immobilized in front of an ammonium-selective electrode and used to develop a biosensor for asparagine. The biosensor had a detection limit of 6 x 10(-5) M for L-asparagine. Unlike a sensor based on asparaginase from E. coli, the biosensor based on recombinant asparaginase from A. fulgidus demonstrated higher stability.

Archaeoglobus fulgidus↗

Picoamperometric detection of glucose at ultrasmall platinum-based biosensors: preparation and characterization.

A simple method is described for the construction of a glucose biosensor with good reproducibility. After electrochemical etching, the sensing tip of an etched platinum microelectrode was insulated using a synthetic rubber dip coating. The insulating layer was then heat-cured, leading to a small exposed area at the very end of the etched Pt tip, as confirmed by scanning electron microscopy. Phenol and 2-allylphenol were electropolymerized to form an extra insulating layer that effectively retained glucose oxidase (GOX) on the sensing tip of the electrode. On the basis of cyclic voltammetry measurements, the apparent radius of the biosensor tip was estimated to be between 10 and 500 nm, depending on GOX loading. With operational and storage stabilities over 3 weeks, the glucose biosensor prepared using optimal GOX concentration (10 mg/mL) exhibited a picoamperometric current response within approximately 2 s and a detection limit of 20 microM with excellent reproducibility.

Biosensing Techniques↗

Layered double hydroxides: an attractive material for electrochemical biosensor design.

Electrochemical biosensors for phenol determination were developed based on the immobilization of polyphenol oxidase (PPO) within two different clay matrixes, one anionic (layered double hydroxide, LDH) and the other cationic (Laponite). The biosensor based on the enzyme immobilized in [Zn-Al-Cl] LDH shows greater sensitivity (7807 mA M(-1) cm(-2)) and maximum current (492 microA cm(-2)). Biosensor characteristics, such as Michaelis-Menten constant, recycling constant, activation energy, and permeability highlight the advantages of LDH matrixes to immobilize PPO. It appears that LDH provides a favorable environment to PPO activity. The best PPO/[Zn-Al-Cl] configuration was used to determine five different phenol derivatives reaching extremely sensitive detection limits (< or = 1 nM).

Biosensing Techniques↗

Metabolite-sensitive holographic biosensors.

A new type of biosensor that combines the inexpensiveness and mass-produceability of reflection holograms with the selectivity and specificity of enzymes is described. pH-sensitive holographic sensors were fabricated from ionizable monomers incorporated into thin, polymeric, hydrogel films which were transformed into volume holograms using a diffusion method coupled with holographic recording, using a frequency-doubled Nd:YAG laser (532 nm). These holograms were used as transducer systems to monitor the pH changes associated with specific enzymatic reactions to construct prototype urea- and penicillin-sensitive biosensors. The diffraction wavelength (color) of the holographic biosensors was used to characterize their shrinkage and swelling behavior as a function of analyte concentration. The potential of these sensors for the measurement of the clinically and industrially important metabolites urea and penicillin G is demonstrated.

Biosensing Techniques↗

Composite carbon paste biosensor for phenolic derivatives based on in situ electrogenerated polypyrrole binder.

Amperometric biosensors based on new composite carbon paste (CPE) electrodes have been designed for the determination of phenolic compounds. The composite CPEs were prepared by in situ generation of polypyrrole (PPy) within a paste containing the enzyme polyphenol oxidase (PPO). The best paste composition (enzyme/pyrrole monomer/carbon particles/Nujol) was determined for a model enzyme, glucose oxidase, according to the enzymatic activity of the resulting electrodes and to the enzyme leakage from the paste during storage in phosphate buffer. The in situ electrogenerated PPy enables improvement in enzyme immobilization within the paste since practically no enzyme was lost in solution after 72 h of immersion. Moreover, the enzyme activity remains particularly stable under storage since the biocomposite structure maintains 80% of its activity after 1-month storage. Following the optimization of the paste composition, PPO-based carbon paste biosensors were prepared and presented excellent analytical properties toward catechol detection with a sensitivity of 4.7 A M(-1) cm(-2) and a response time lower than 20 s. The resulting biosensors were finally applied to the determination of epicatechin and ferulic acid as flavonol and polyphenol model, respectively.

Journal Article↗

Adenosine-dependent assembly of aptazyme-functionalized gold nanoparticles and its application as a colorimetric biosensor.

Previous work has shown that DNAzyme-directed assembly of gold nanoparticles can be utilized to make effective colorimetric biosensors. However, the method is restricted to analytes that are directly involved in phosphodiester cleavage. To expand the methodology to a broader range of analytes, a colorimetric adenosine biosensor based on the aptazyme-directed assembly of gold nanoparticles is reported here. The aptazyme is based on the 8-17 DNAzyme with an adenosine aptamer motif that can modulate the DNAzyme activity through allosteric interactions depending on the presence of adenosine. In the absence of adenosine, the aptazyme is inactive and the substrate strands can serve as linkers to assemble DNA-functionalized 13-nm-diameter gold nanoparticles, resulting in a blue color. However, the presence of adenosine activates the aptazyme, which cleaves the substrate strand, disrupting the formation of nanoparticle aggregates. A red color of separated gold nanoparticles is observed. Concentrations of adenosine of up to 1 mM can be measured semiquantitatively by the degree of blue to red color changes or quantitatively by the extinction ratio at 520 and 700 nm. Under the same conditions, 5 mM guanosine, cytidine, or uridine resulted in a blue color only, indicating good selectivity of the sensor. The color difference can be clearly observed by the naked eye by spotting the resulting sensor solution onto an alumina TLC plate. Since aptamers that can target many classes of important analytes have already been selected, they can be adapted into aptazyme systems through rational design or further selection. Thus, colorimetric biosensors for many analytes of interest can be designed using the method presented here, regardless of whether the analytes are directly involved in the cleavage reaction or not.

Adenosine↗

Development of an autofluorescent translocation biosensor system to investigate protein-protein interactions in living cells.

Protein-protein interactions are crucial for all cellular events. To analyze protein-protein interactions in live mammalian cells, we developed novel protein translocation biosensors composed of glutathione S-transferase, mutants of GFP, and a rational combination of nuclear import and export signals. Nuclear accumulation of the cytoplasmic biosensors served as the reliable indicator, which was induced by the formation of protein complexes and could easily be detected by fluorescence microscopy. The efficacy of the system was systematically investigated by mapping the p53/mdm2 protein interaction interface. Specificity and general applicability of the biosensors were confirmed by studying additional classes of protein interaction domains (IDs), e.g., the leucine zipper IDs of Jun/Fos and the coiled-coil ID of Bcr-Abl in different cell lines. Importantly, we found that, in comparison to protein complementation assays, our system proved highly efficient and reversible and thus suited for the identification of molecular decoys to prevent specific protein-protein interactions in living cells. Reversibility was demonstrated in competition experiments by overexpressing the specific IDs or by the application of a p53/mdm2 protein interaction inhibitor. Thus, besides the convenient mapping of protein IDs in living cells, the modular translocation system has great potential to be employed in numerous cell-based assays for the identification of small-molecule protein interaction inhibitors as potential novel therapeutics.

Animals↗

Peptide nanotube-modified electrodes for enzyme-biosensor applications.

The fabrication and notably improved performance of composite electrodes based on modified self-assembled diphenylalanine peptide nanotubes is described. Peptide nanotubes were attached to gold electrodes, and we studied the resulting electrochemical behavior using cyclic voltammetry and chronoamperometry. The peptide nanotube-based electrodes demonstrated a direct and unmediated response to hydrogen peroxide and NADH at a potential of +0.4 V (vs SCE). This biosensor enables a sensitive determination of glucose by monitoring the hydrogen peroxide produced by an enzymatic reaction between the glucose oxidase attached to the peptide nanotubes and glucose. In addition, the marked electrocatalytic activity toward NADH enabled a sensitive detection of ethanol using ethanol dehydrogenase and NAD+. The peptide nanotube-based amperometric biosensor provides a potential new tool for sensitive biosensors and biomolecular diagnostics.

Biosensing Techniques↗

Charge transfer through DNA: A selective electrochemical DNA biosensor.

The charge-transfer properties of DNA duplexes are exploited to produce a fast, simple, sensitive, and selective DNA biosensor by exposing the DNA recognition interface to a sample containing target DNA and the redox-active intercalator, anthraquinonemonosulfonic acid (AQMS). Electrochemistry from electron transfer through the DNA to AQMS intercalated into DNA duplexes can be differentiated from electrochemistry due to direct access of the AQMS to the electrode surface due to the difference in the environment of the AQMS giving a shift in the potential at which the molecule is reduced. The ability to distinguish between the two electrochemical signals enables DNA hybridization to be monitored in real time. This in situ detection scheme has good selectivity, being able to differentiate between a complementary target DNA sequence and one containing either C-A or G-A single-base mismatches. The concentration detection limit of the biosensor is 0.5 nM (1 pmol) with an assay time of 1 h. The fact that the end user is only required to simultaneously add the sample containing the target DNA and AQMS gives a DNA biosensor that is highly compatible with PCR on chip technologies.

Anthraquinones↗

Biosensor recognition of thyroid-disrupting chemicals using transport proteins.

Novel surface plasmon resonance-based biosensor assays for the bioeffect-related screening of chemicals with thyroid-disrupting activity are described. Two thyroid transport proteins (TPs), thyroxine binding globulin (TBG) and recombinant transthyretin (rTTR), were applied in an inhibition assay format in a Biacore 3000 using CM5 biosensor chips coated with l-thyroxine (T4), the main hormone of the thyroid system. Assay conditions were optimized for the natural thyroid hormones, and known thyroid disruptors and structurally related compounds were selected as model compounds to be tested in both assays for their relative potency (RP) compared to T4. The chosen compounds were halogenated phenols, halogenated bisphenols, bisphenol A, 3,5-dichlorobiphenyl, and its hydroxylated metabolite 4-hydroxy-3,5-dichlorobiphenyl (4-OH PCB 14). The TBG-based assay was highly specific for T4, and the rTTR-based assay was sensitive toward several compounds, the highest sensitivity (RP = 4.4) being obtained with 4-OH PCB 14, followed by tetrabromobisphenol A (RP = 1.5) and tetrachlorobisphenol A (RP = 0.75). For the bioeffect-related screening of known and identification of possible new thyroid disruptors, the TPs-based biosensor assays were more sensitive (IC(50) of 13.7 +/- 1.3 and 8.6 +/- 0.7 nM for the rTTR and the TBG-based assay, respectively), easier to perform, and faster alternatives (10 min/sample) than the currently used methods such as radioligand binding assays and immunoprecipitation-HPLC.

Biosensing Techniques↗