PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “AORTIC VALVE STENOSIS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Isolated aortic valve stenosis in the eighth decade.

Aortic valve stenosis was evaluated in 26 patients in the eighth decade of life, representing 20% of all patients referred for aortic valve stenosis. There were no clinical features which distinguished this older group from younger patients. Coronary artery disease was present in 46% of the older group, 30% in the younger. Angina pectoris or an infarction pattern on the electrocardiogram was not useful in predicting coronary artery disease in either group. A dominant left coronary circulation was more frequent (22%) in the younger than the older group. This was related to the higher incidence of congenitally deformed aortic valves (55%) found in the younger, compared in the advanced age group (5%). The surgical mortality in the younger and advanced age group was 8 and 20%, respectively. Mortality in both groups was related in more than half the patients to coronary artery disease.

Age Factors↗

Transverse aortic wall tears in infants after balloon angioplasty for aortic valve stenosis: relation of aortic wall damage to diameter of inflated angioplasty balloon and aortic lumen in seven necropsy cases.

Aortic wall tears resulting from rupture of dilating balloons in infants undergoing transluminal balloon angioplasty have not been previously recognized. A 2 day old infant had percutaneous transluminal balloon angioplasty to dilate a stenotic aortic valve, and after multiple balloon inflations the balloon burst. The infant died 2 days after undergoing transluminal balloon angioplasty and at necropsy a circumferential, transverse aortic wall tear was found. To test the hypothesis that rupture of appropriately sized balloons results in similar aortic wall tears, six unfixed, intact infant aortas were subjected to transluminal balloon angioplasty at necropsy: two infants had balloon rupture with inflated balloon diameter similar to that of the aorta, two had balloon rupture with an undersized balloon and two had dilation with an oversized balloon. Transverse wall tears occurred in aortas with similar aortic and balloon diameters; no aortic wall damage occurred with rupture of undersized balloons, and aortic rupture resulted from the use of oversized balloons. Thus, intimal-medial tears in the infant aorta may result from balloon bursting during angioplasty when aortic and inflated balloon diameters are similar.

Angioplasty, Balloon↗

Aortic valve stenosis. Management in children and adults.

Aortic valve stenosis may be congenital or acquired. Medical management includes advice to avoid heavy physical effort, prevention of infective endocarditis, use of digitalis and diuretics for cardiac failure, and preservation of atrial systole. When operation is necessary, open aortic valve commissurotomy is preferred in children and replacement of the valve is preferred in adults. Women of childbearing age should use conventional barrier contraceptives, and those with severe stenosis should have valve replacement before becoming pregnant. Aortic valvuloplasty, particularly in adults, is only of temporary benefit.

Adolescent↗

The safety of dipyridamole-thallium imaging in patients with critical aortic valve stenosis and angina.

Angina pectoris occurs in many patients with critical aortic valve stenosis, but in less than 50% of cases is it due to atherosclerotic coronary disease. Pre-operative coronary angiography is used to determine whether coronary revascularization is required in addition to aortic valve replacement. The aim of this study was to determine the safety and image quality of dipyridamole-thallium imaging (DPT) in excluding coronary artery disease requiring a coronary artery bypass graft in patients with aortic valve stenosis requiring aortic valve replacement. Dipyridamole-thallium imaging and coronary angiography were performed less than one month apart in patients with clinical and echo-Doppler evidence of aortic valve stenosis requiring aortic valve replacement. Coronary angiography and DPT were each interpreted by experienced observers blind to the other result. The safety of DPT was judged by symptoms, ECG changes, haemodynamic effects and the need for stress reversal. Image quality was determined from the myocardial-to-background thallium uptake ratio in a normal segment. Twelve patients with aortic valve stenosis (gradient 95 +/- 24 mmHg) were studied, all of whom had left ventricular hypertrophy. The dominant symptom was angina pectoris in eight patients, syncope in three and dyspnoea in one. None had previous myocardial infarction, but two were smokers, six were hyperlipidaemic and one was hypertensive. The patients tolerated DPT well and only one required stress reversal. The quality of the DPT images was good. The DPT image was entirely normal in eight (66%) patients, none of whom had coronary artery disease. Reversible defects were seen in four patients, all of whom had significant coronary artery disease. We conclude that DPT is safe in patients with aortic valve stenosis and angina pectoris. The image quality is good despite left ventricular hypertrophy. In patients with angina pectoris and aortic valve stenosis, coronary angiography can safely be restricted to those with abnormal myocardial perfusion results.

Aged↗

Prognostic value of carotid intima-media thickness in detection of coronary atherosclerosis in patients with calcified aortic valve stenosis.

OBJECTIVE: Aortic stenosis (AS) coexists with coronary artery disease (CAD) in at least 30% of patients. Patients with concomitant CAD may benefit from simultaneous coronary bypass grafting. This study aimed to evaluate the prognostic value of carotid intima-media thickness (IMT) in patients with AS in assessing concomitant CAD. METHODS: Group I consisted of 33 patients (mean age +/- SD, 61.0 +/- 8.2 years; 18 men and 15 women) with AS but without CAD on angiograms. Group II consisted of 34 patients (64.4 +/- 8.0 years; 25 men and 9 women) with AS and CAD confirmed angiographically. A control group included 36 patients (61.2 +/- 4.9 years; 18 men and 18 women) with normal coronary arteries and no AS. Maximal IMT was assessed in all patients at the common carotid artery, bulb, and internal carotid artery and expressed as a mean value. RESULTS: There were no differences among the respective groups with regard to age, sex, frequency of hypertension, diabetes, and smoking habit, although patients with CAD were more often hyperlipemic (P = .038). The IMT of the common carotid artery, bulb, and internal carotid artery was significantly higher in patients with AS and CAD compared with both the control group and patients with AS only. The multivariable regression model revealed that CAD (P < .001), AS (P = .006), male sex (P = .034), age (P < .001), and diabetes mellitus (P = .047) were independent risk factors for IMT thickening. A mean IMT value of greater than 1.2 mm was predictive (sensitivity, 73.5%; specificity, 72.7%) of concomitant CAD in patients with AS. CONCLUSIONS: Intima-media thickness increases in patients with AS. The greatest IMT values are observed in patients with both AS and CAD. Patients with AS might be suspected of having CAD when the IMT value exceeds 1.2 mm.

Aged↗

[Percutaneous balloon valvotomy in neonatal obstructive cardiopathy. II. Critical aortic valve stenosis].

Percutaneous balloon aortic valvotomy using one or more balloons in sequential approach was attempted in 11 non selected neonates with critical aortic valve stenosis. The procedure was complete in 9 (81%), and they represent the study group with a mean age of 19 days. Using a balloon/annulus ratio of 0.86, the transvalvar gradient decreased from 49 to 25 mmHg, and left ventricular systolic pressure fell from 112 mmHg to 96 mmHg (p < 0.01, respectively). Fifty-five percent (5/9) of the patients developed a new aortic regurgitation, only one with grade 3. The maximal instantaneous Doppler gradient recorded in 7 neonates before and after valvotomy dropped from 67 to 35 mmHg (p < 0.01); while the left ventricular shortening fraction increased from 15 to 31% (p < 0.01). The Doppler gradient was correlated with the left ventricular shortening fraction (r:0.72) and the aortic regurgitation with the balloon/annulus ratio (r:0.82). The balloon pulmonary valvotomy was unsuccessful in 2 neonates (22%), both with hypoplastic left ventricle, both of which died in the operating room. Echocardiographic features of reestenosis were not found in the follow-up period (14 +/- 10 months); only one patient may need a future surgical intervention because significant aortic insufficiency. The pulmonary balloon valvotomy is a safe and effective therapy that must be used as the first step in the management of neonates with critical aortic stenosis in absence of hypoplastic left ventricle.

Aortic Valve Stenosis↗

Rare association of tetralogy of Fallot and aortic valve stenosis. Autopsy findings after failed balloon aortic valvuloplasty.

We report the case of a neonate with a rare association of tetralogy of Fallot and aortic valve stenosis, who died following percutaneous balloon valvuloplasty. Postmortem examination confirmed a tetralogy of Fallot morphology with a markedly hypoplastic pulmonary tree, hypertrophy of both ventricles, and a thickened and dysplastic aortic valve. Valvuloplasty was not effective despite the presence of a fissure in the cusp. The findings suggest that the left ventricular impairment and associated anomalies, with or without a dysplastic valve may contribute to the failure of balloon valvuloplasty in neonates with critical aortic valve stenosis.

Aortic Valve Stenosis↗

Preliminary experience in the use of ultrafast computed tomography to diagnose aortic valve stenosis.

Eight patients, mean age 72 years, with aortic valve stenosis were studied by ultrafast CT 1 day after cardiac catheterization. After injection of radiographic contrast material through a peripheral vein, two contiguous eight-level R wave-triggered cine mode scans in the short axis were acquired, starting above the aortic valve and continuing through the apex of the left ventricle. Seven of eight patients, all with calcified aortic valves, had a detectable central orifice. Catheterization-derived aortic valve areas were within 0.25 cm2 of the CT valve areas in six of seven. LV mass was measured by ultrafast CT in the eight patients with aortic valve stenosis (121.6 +/- 18.2 gm/m2) and was found to be significantly higher (p less than 0.0001) than that in a group of eight subjects with normal LV function, no history of hypertension, and normal ECGs (73.0 +/- 13.1 gm/m2). It is concluded that in selected cases ultrafast CT can contribute to the assessment of severity of calcific aortic stenosis by measurement of LV mass and valve area.

Aged↗

Comparison of age, gender, number of aortic valve cusps, concomitant coronary artery bypass grafting, and magnitude of left ventricular-systemic arterial peak systolic gradient in adults having aortic valve replacement for isolated aortic valve stenosis.

Correlation of the structure of the operatively excised aortic valve with various clinical variables has received relatively little attention. This report describes certain observations in 115 patients aged >30 years (mean age 70) who had aortic valve replacement for aortic valve stenosis unassociated with mitral valve dysfunction. The operatively excised aortic valve was congenitally unicuspid in 3 patients (3%), congenitally bicuspid in 54 patients (47%), tricuspid in 57 patients (50%), and of uncertain structure in 1. Of the 87 patients (76%) aged > or =65 years (Medicare population), 36 (41%) had congenitally malformed valves (bicuspid in each), and of the 28 patients (24%) aged <65 years, 21 (75%) had congenitally malformed valves. A higher percentage of patients with congenitally malformed valves had peak systolic pressure gradients across the valve >50 mm Hg than did patients with tricuspid valves (57% vs 43%). Concomitant coronary artery bypass grafting (CABG) was performed in 52 patients (45%) (34 men and 18 women), and they had average peak systolic pressure gradients across the valve significantly lower than patients without coronary bypass (46 vs 64 mm Hg): 39% of the 57 patients with congenitally malformed valves and 53% of the 57 patients with tricuspid valves had concomitant coronary bypass (insignificant difference). Thus, in a relatively older population of 115 patients having aortic valve replacement for isolated aortic valve stenosis, with or without associated aortic regurgitation, one half had congenitally malformed valves (either unicuspid or bicuspid valves) and one half had tricuspid valves. Patients having concomitant CABG had significantly smaller gradients across the stenotic valves than those who had no CABG.

Adult↗

Distinct down-regulation of cardiac beta 1- and beta 2-adrenoceptors in different human heart diseases.

Cardiac beta-adrenoceptor density and beta 1- and beta 2-subtype distribution were examined in human left ventricular myocardium from transplant donors serving as controls and from patients with mitral valve stenosis, aortic valve stenosis, idiopathic dilated cardiomyopathy, and ischaemic cardiomyopathy respectively. The total beta-adrenoceptor density was similar in transplant donors and patients with moderate heart failure (NYHA II-III) due to mitral valve stenosis, but was markedly reduced in all forms of severe heart failure (NYHA III-IV) studied. A reduction of both beta 1- and beta 2-adrenoceptors was found in patients with severe heart failure due to mitral valve stenosis or ischaemic cardiomyopathy. In contrast, a selective down-regulation of beta 1-adrenoceptors with unchanged beta 2-adrenoceptors and hence a relative increase in the latter was observed in idiopathic dilated cardiomyopathy and aortic valve stenosis. It is concluded that the extent of total beta-adrenoceptor down-regulation is related to the degree of heart failure. Selective loss of beta 1-adrenoceptors is not specific for idiopathic dilated cardiomyopathy but also occurs in aortic valve stenosis. Changes in beta 1- and beta 2-subtype distribution are rather related to the aetiology than to the clinical degree of heart failure.

Adult↗

Comparison of valve structure, valve weight, and severity of the valve obstruction in 1849 patients having isolated aortic valve replacement for aortic valve stenosis (with or without associated aortic regurgitation) studied at 3 different medical centers in 2 different time periods.

BACKGROUND: Aortic valve replacement (AVR) for patients with aortic stenosis (AS) has now been available for 45 years. During this period, indications for the procedure have changed. METHODS AND RESULTS: Operatively excised stenotic aortic valves (with or without associated aortic regurgitation and without associated mitral valve disease) from 3 different medical centers (National Institutes of Health, Georgetown University Medical Center, and Baylor University Medical Center) were examined during 2 different time periods by the same physician to compare aortic valve structure, valve weight, age at operation, preoperative transvalvular peak pressure gradient, calculated aortic valve area, and whether simultaneous coronary artery bypass grafting (CABG) was performed. Compared with the first 3 decades (1961-1990) of AVR, patients having this operation during the fourth and fifth decades (1991-2004) had a lower frequency of congenitally malformed aortic valves, a higher frequency of tricuspid aortic valves, an older age, valves of lighter weight and lower transvalvular peak pressure gradients, and more often simultaneous CABG. CONCLUSIONS: Although patients having isolated AVR for AS in the present and last decade were older than in the first 3 decades of valve replacement surgery, congenitally malformed aortic valves continue to be more common than tricuspid aortic valves, but the degree of AS and therefore, valve weight was significantly lower than in the earlier decades.

Adult↗

Successful pregnancy achieved by assisted reproductive techniques in a woman with severe congenital bicuspid aortic valve stenosis.

OBJECTIVES: To report a twin pregnancy achieved by assisted reproductive techniques in a woman with severe congenital bicuspid aortic valve stenosis. METHODS: Intracytoplasmic sperm injection and embryo transfer was performed in a 38-year-old woman with a complaint of infertility for 8 years due to male factor and who previously had the diagnosis of severe congenital bicuspid aortic stenosis. Clinical and echocardiography follow-up during pregnancy was done. RESULTS: The woman had severe congenital aortic stenosis with a valve area of 0.4 cm(2) and a peak gradient of 57 mmHg. In the first trial, twin pregnancy was achieved. She had an uneventful course of pregnancy in terms of cardiac functions. She underwent caesarean section at 36 weeks of gestation and had a healthy female and a male newborns. CONCLUSIONS: A woman with a severe congenital bicuspid aortic valve may get pregnant and deliver healthy newborns with intensive prenatal care and follow-up. The severe congenital bicuspid aortic valve stenosis may not be considered an absolute contraindication for assisted reproductive techniques and pregnancy.

Adult↗

Calculation of left ventricular outflow tract area using three-dimensional echocardiography. Influence on quantification of aortic valve stenosis.

In 23 patients with aortic valve stenosis (14 male, 9 female, mean age 66 +/- 21.5 years) left ventricular outflow tract cross-sectional area was determined in planimetric fashion using three-dimensional echocardiography. The 3-D data-set for each patient had been acquired in the course of a multiplane transesophageal examination. Aortic valve area was determined using the continuity equation. Results obtained were compared to those calculated by continuity equation using to the conventionally determined LVOT area (a = pi [d/2]2). As reference method the results were compared to invasive measurements. 3-D planimetric determination of LVOT cross-sectional area was possible in 20 of 23 patients. In three patients, this method failed due to artefacts. The mean difference to the conventionally calculated LVOT area amounted to 0.18 cm2 (SD = 0.46). The comparison of AVA determined by continuity equation and by invasive measurement showed a mean difference of -0.074 cm2 (SD = 0.21) for the conventionally calculated LVOT area; for the planimetrically determined LVOT area the mean difference of AVA amounted to -0.03 cm2 (SD = 0.14) (p < 0.05). Planimetric determination of LVOT area using 3-D echocardiography improves the agreement of the continuity equation with invasive measurement.

Aged↗

Apolipoproteins AI, B, and E polymorphisms in severe aortic valve stenosis.

Hypercholesterolemia has been related to aortic valve stenosis (AS). Polymorphisms of apolipoproteins (apo) AI, B, and E are associated with variable levels of plasma lipids, but the association between these polymorphisms and AS is unknown. In a case-control study of groups matched by age, sex, comparable body mass index, hypertension, triglycerides, high-density lipoprotein (HDL) cholesterol, and low-density lipoprotein (LDL) cholesterol, we analyzed the distribution of apo AI A/G mutation, apo B signal peptide insertion/deletion, apo B XbaI restriction fragment length. and apo E polymorphisms in 62 non-diabetic patients with severe aortic valve stenosis and 62 control subjects. All patients underwent echocardiographic analysis. Univariate analysis showed a higher prevalence of the XbaI X + /X + genotype (p = 0.007) of apo B and the apo E2 allele (p = 0.034) in patients with severe AS. Apo polymorphisms were not associated with lipid levels, left ventricular mass, or the aortic gradient.

Aortic Valve Stenosis↗

Reduced left ventricular size and endocardial fibroelastosis as correlates of mortality in newborns and young infants with severe aortic valve stenosis.

30 patients with severe aortic valve stenosis presented in severe congestive heart failure within the first 2 months of life. In 25 of them, left ventricular volume and contractility were assessed; five of them had a left ventricle of normal size, in 11 left ventricular size was diminished, and in nine patients it was enlarged. Eleven of the infants had extensive endocardial fibroelastosis (EFE) evidenced angiographically by myocardial sinusoids in ten of them and established at autopsy in six. The presence of EFE correlated with the size of the left ventricle; eight of 11 with a small left ventricle, two of five with a normal-sized left ventricle, and one of nine with an enlarged left ventricle displayed EFE. The severe depression of left ventricular function associated with EFE was documented by left ventricular volume determinations on exclusion of the myocardial sinusoids. Of 30 patients, 12 (including eight of 26 who underwent surgery) did not survive. Mortality, severity, and early onset of symptoms were associated mainly with small size of the left ventricle and with the severe left ventricular dysfunction associated with EFE.

Aortic Valve Stenosis↗

[Preoperative magnetic resonance imaging evaluation of the aortic annular diameter in aortic valve stenosis].

Accurate preoperative knowledge of the aortic annular diameter is a great value in determining the appropriate procedure for aortic valve stenosis. We have successfully used magnetic resonance imaging (MRI) to evaluate the size of the aortic annular diameter preoperatively. Between October 1997 and October 1998, 5 aortic valve replacements were performed in patients with aortic valve stenosis. MRI was performed preoperatively in all cases. All images were gated to the R-wave of the electrocardiogram. Images representing 5 mm slices were acquired in the plane which is parallel to the line through the center points of the aortic root and left ventricle outflow tract. The maximum diameter of the aortic annulus (D) was measured at the point just below the attachment of the aortic valve leaflets. This diameter was compared to the maximum diameter of the prosthetic valve sizer (D 1) which could be easily inserted into the aortic annulus intraoperatively, and to the diameter of the prosthetic valve (D 2) that ultimately was implanted. Twenty-five minutes were required to scan each patient. There were no complications related to scanning. Mean values were D = 23.4 mm, D 1 = 22.3 mm and D 2 = 21.4 mm. There was a significant correlation between D and D 1, and D 2 was approximately 2 mm smaller than D. MRI evaluation is an accurate, noninvasive method for determining the aortic annular diameter preoperatively. We highly recommend this method for measuring the aortic annular diameter in case of aortic valve stenosis as part of the preoperative evaluation.

Aorta↗