PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Atrial Appendage”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Thoracoscopic extracardiac obliteration of the left atrial appendage for stroke risk reduction in atrial fibrillation.

OBJECTIVES: We evaluated left atrial appendage obliteration in high-risk patients with atrial fibrillation (AF). BACKGROUND: Left atrial appendage thrombosis and embolization is the principal mechanism of stroke in AF. Anticoagulation is underutilized and often contraindicated. METHODS: Thoracoscopic Left Appendage, Total Obliteration, No cardiac Invasion (LAPTONI) was undertaken with a loop snare in eight patients and a stapler in seven patients, median age 71 years, with clinical risk factors for stroke and with an absolute contraindication to or failure of prior thrombosis prevention with warfarin. Eleven patients had a history of prior thromboembolism. One patient took sustained warfarin during follow-up. RESULTS: The LAPTONI procedure was completed in 14 of 15 patients, and 1 patient required urgent conversion to open thoracotomy because of bleeding. Patients have been followed up for 8 to 60 months, mean 42 +/- 14 months. One fatal stroke occurred 55 months after surgery, and one non-disabling stroke three months after surgery. Two other deaths occurred, one after coronary bypass surgery and the other from hepatic failure. The subgroup of 11 patients with prior thromboembolism had an annualized rate of stroke of 5.2% per year (95% confidence interval [CI] 1.3 to 21) after LAPTONI, which compares to a rate of 13% per year (95% CI 9.0 to 19) for similar aspirin-treated patients from the Stroke Prevention in Atrial Fibrillation trials (p = 0.15). CONCLUSIONS: The LAPTONI procedure appears technically feasible without immediate disabling neurologic morbidity or mortality, and it demonstrates low post-operative event rates and a statistical trend toward thromboembolic risk reduction in high-risk AF patients.

Adult↗

Potential applicability and utilization of left atrial appendage occlusion devices in patients with atrial fibrillation.

BACKGROUND: The WATCHMAN left atrial appendage occluder device (Atritech, Inc, Minneapolis, MN) is currently being tested in a Food and Drug Administration-approved clinical trial, the PROTECT AF trial, for patients who are diagnosed with paroxysmal, persistent, or permanent nonvalvular atrial fibrillation. However, rigorous screening and the study design have resulted in the exclusion of a large number of patients. Hence, the purpose of this study was to assess the potential utility of this device among those who were eligible but excluded for trial criteria and the reasons for exclusion. METHODS: Screening logs from the respective sites participating in the PROTECT AF trial were collected and analyzed for potential utilization outside of a research trial. Only 31 patients were enrolled into the research trail from the screening of 1798 total patients. RESULTS: Information from the excluded patients was examined and it was determined that 79% of these patients would be eligible for the device outside the research trial. Twenty-one percent of patients were not able to receive the device because of long-term warfarin need, contraindications to warfarin, unsuitable anatomy as determined by echocardiography, or the inability to take short-term aspirin and clopidogrel for protocol requirements. CONCLUSIONS: Should a device like the WATCHMAN left atrial appendage occluder be approved, approximately 79% of all patients with atrial fibrillation would be eligible for device placement.

Atrial Appendage↗

Left atrial appendage anatomy and function: short term response to sustained atrial fibrillation.

OBJECTIVE: To determine whether there is significant atrial or atrial appendage enlargement or functional remodelling as a result of one to two months of sustained atrial fibrillation, a duration similar to that experienced by patients undergoing warfarin anticoagulation before elective cardioversion. METHODS: To test the hypothesis that left atrial and left atrial appendage enlargement develop as a result of short term atrial fibrillation, serial anatomical and functional indices were measured using transoesophageal echocardiography (TOE) in 20 patients with recent onset atrial fibrillation (14 men, six women; mean (SEM) age 67 (2) years). Serial TOE was performed 2.5 months apart in patients with sustained atrial fibrillation. RESULTS: There was no significant change in left atrial area (23.7 cm(2) to 24.1 cm(2), p = 0.98); length (5.7 cm to 5.7 cm, p = 0.48); width (5.2 cm to 5.2 cm, p = 0. 65); volume (83 cm(3) to 87 cm(3), p = 0.51) or left atrial appendage area (7.9 cm(2) to 8.1 cm(2), p = 0.89); length (4.6 cm to 4.5 cm, p = 0.8); or width (2.5 to 2.4 cm, p = 0.87). Peak left atrial appendage velocity ejection (0.2 m/s to 0.2 m/s, p = 0.57), and presence of severe spontaneous echo contrast in the left atrial appendage (n = 15 (75%) to n = 13 (72%)) were also not significantly different. There was no correlation between changes in left atrial or left atrial appendage dimensions. CONCLUSIONS: In the setting of sustained atrial fibrillation, significant left atrial and left atrial appendage functional and anatomical remodelling do not occur with atrial fibrillation of a duration similar to that used for conservative anticoagulation in preparation for cardioversion.

Adult↗

Is left atrial appendage occlusion useful for prevention of stroke or embolism in atrial fibrillation?

Since in atrial fibrillation more than 90% of the thrombi are located in the left atrial appendage, an "elimination" of the left atrial appendage, either by resection or occlusion, seems an attractive alternative to oral anticoagulation. Although frequently regarded as an useless appendage, data from animal and human investigations show that the left atrial appendage may play an important role in the maintenance and regulation of the cardiac function, especially in arterial hypertension, atrial fibrillation, coronary heart disease, valvular heart disease and heart failure. Elimination of the left atrial appendage may impede thirst in hypovolemia, deteriorate hemodynamic responses to volume or pressure overload, decrease cardiac output and promote heart failure. Instead of preventing stroke, the consequences of left atrial appendage elimination may create new risk factors for stroke and thus might induce more harm than benefit to patients with atrial fibrillation. As long as the physiologic and pathophysiologic role of the left atrial appendage is not fully understood, left atrial appendage elimination should not be an alternative to oral anticoagulation.

Animals↗

Electrocardiographic features of atrial depolarization during pacing of right atrial appendage.

Identification of atrial capture during pacing from right atrial appendage is frequently difficult. Electrocardiograms of forty five patients implanted with AAI/DDD pacemakers (thirty unipolar, fifteen bipolar) were analysed to characterize the specific morphology of paced P waves. Compared to sinus P waves, atrial pacing resulted in atrial depolarization of lower amplitude (0.16 +/- 0.05 mv vs 0.11 +/- 0.032 mv, P less than 0.005) but increased duration (0.07 +/- 0.009 sec vs 0.08 +/- 0.017 sec, P less than 0.005). P wave morphology was similar in unipolar and bipolar pacing units. It was positive in lead I (80%), II (71.11%), III (80%) and aVF (75.55%). In lead aVL, paced P waves were usually diphasic with an initial negative deflection (35.55%). Precordial leads showed paced atrial depolarization of small amplitude and did not help in identification of atrial capture. In unipolar pacing P waves were best seen in lead III because of small pacing spike in this lead. Lead II was suitable for identification of paced P waves in bipolar pacing. Thus careful examination of standard ECG leads for paced P waves of low amplitude, prolonged duration and specific morphology can help in confirming atrial capture following pacing stimulus from right atrial appendage.

Adult↗

A novel device for left atrial appendage exclusion.

OBJECTIVE: The left atrial appendage is a frequent source of thromboemboli in patients with atrial fibrillation. Exclusion or excision of the left atrial appendage may reduce the risk of stroke in patients with atrial fibrillation. We evaluated the ability of a novel device to exclude the left atrial appendage during early and intermediate follow-up periods in a canine model. METHODS: Eight mongrel dogs (mean weight 29.1 +/- 4.0 kg) were used in this study. The occlusion device, constructed from 2 stainless steel strips covered with a knit braided polyester fabric, was implanted at the base of the left atrial appendage through a left thoracotomy on a beating heart. Dogs were evaluated at 7 days (n = 2), 30 days (n = 2), and 90 days (n = 4) by epicardial echocardiography, left atrial angiography, histologic inspection, and gross pathology. RESULTS: Device implantation was performed without complications in all animals. Complete exclusion of the left atrial appendage from the circulation was confirmed acutely and chronically by echocardiographic and angiographic evaluations. There was no device migration or damage to adjacent structures. CONCLUSION: This novel device enables rapid, reliable, and safe exclusion of the left atrial appendage. The device provides a new therapeutic option for reducing the risk of stroke in patients with atrial fibrillation.

Animals↗

Improved surgical approach to left atrial appendage aneurysm.

Left atrial appendage aneurysm is a rare anomaly, which usually presents with arrhythmia or cerebral embolism. Diagnostic evaluation traditionally required cardiac catheterization, and surgical resection required cardiopulmonary bypass. Utilizing intraoperative transesophageal echocardiography and surgical stapling devices, we have streamlined our operative technique, allowing resection of a left atrial appendage aneurysm without cardiopulmonary bypass. This report of two cases treated over the past decade demonstrates the evolution of our surgical technique.

Adult↗

Predictors of left atrial appendage stunning after electrical cardioversion of non-valvular atrial fibrillation.

OBJECTIVE: To identify predictors of left atrial appendage stunning after the use of electrical cardioversion to restore sinus rhythm in patients with non-valvular atrial fibrillation. METHODS: A total of 68 consecutive patients (45 men, 23 women, 60.5 +/- 8.7 years of age) with non-valvular atrial fibrillation undergoing electrical cardioversion were enlisted in this study. Clinical and echocardiographic variables were analyzed by univariate regression and multivariate logistic regression to investigate the relationship between occurrences of left atrial appendage stunning and these factors. RESULTS: Univariate analysis revealed that, in comparing patients without and with left atrial appendage stunning, there were significant differences in the duration of atrial fibrillation > 8 weeks (32.3% vs 75.5%, P < 0.001), left atrial diameter > 50 mm (29.0% vs 54.1%, P < 0.05), left atrial emptying fraction (31.5% +/- 7.8% vs 27.1% +/- 8.5%, P < 0.05), left ventricular ejection fraction < 50% (38.7% vs 67.6%, P < 0.05), maximum electrical energy (96.8 J +/- 65.8 J vs 156.8 J +/- 100.8 J, P < 0.01), cumulative electrical energy 146.8 J +/- 142.6 J vs 290.5 J +/- 242.1 J, P < 0.01) and number of electrical cardioversion shocks (1.7 +/- 0.9 vs 2.43 +/- 1.20, P < 0.05). However, backward stepwise multivariate logistic regression analysis identified as significant and independent predictors of left atrial appendage stunning only duration of atrial fibrillation > 8 weeks (OR = 7.249, 95% CI = 1.998 - 26.304, P < 0.01), left atrial diameter > 50 mm (OR = 3.896, 95% CI = 1.105 - 13.734, P < 0.05), left ventricular ejection fraction < 50% (OR = 4.465, 95% CI = 1.51713.140, P < 0.01) and cumulative energy of electrical cardioversion (OR = 1.004, 95% CI = 1.000 - 1.008, P < 0.05). CONCLUSIONS: Duration of atrial fibrillation > 8 weeks, left atrial diameter > 50 mm, left ventricular ejection fraction < 50%, and cumulative energy of electrical cardioversion are independent predictors of left atrial appendage stunning. Anticoagulation treatment should be individualized for patients undergoing electrical cardioversion to reduce the risk of both cardioversion-related thromboembolic events and hemorrhagic complications caused by warfarin treatment.

Aged↗

Left atrial appendage function in patients with atrial flutter.

OBJECTIVE: To determine whether echocardiographic markers thromboembolic risk differ between patients with pure atrial flutter and patients with atrial flutter and intermittent atrial fibrillation. DESIGN: Patients with atrial flutter were followed up prospectively for 12 months to identify intermittent atrial fibrillation. After the follow up period, transthoracic and multiplane transoesophageal echocardiography were performed to assess left atrial chamber and appendage size, peak emptying velocities, and emptying fraction of the left atrial appendage. The presence of spontaneous echo contrast was also determined. SETTING: Tertiary cardiac care centre. PATIENTS: 20 consecutive patients with atrial flutter; 11 healthy subjects in sinus rhythm served as controls. RESULTS: Intermittent atrial fibrillation was documented in 11 patients by Holter monitoring or surface ECG; atrial fibrillation was not found in the other nine patients. Compared with the patients with pure atrial flutter, patients with atrial flutter and intermittent atrial fibrillation had larger left atrial chamber (mean (SD) 4.5 (0.6) v 3.8 (0.5) cm; 95% confidence interval 0.2 to 1.2; P = 0.01) and appendage areas (6.7 (2.2) v 4.8 (4.9) cm; 95% CI 0.4 to 3.5; P = 0.02), lower left atrial appendage emptying fractions (33 (11)% v 52 (11)%; 95% CI 8 to 29; P = 0.008), and also lower left atrial appendage emptying velocities (0.44 (0.21) v 0.79 (0.27) m/s; 95% CI 0.13 to 0.56; P = 0.005). In addition, a higher incidence of spontaneous echo contrast (11% v 36%) was observed in patients with atrial flutter and intermittent atrial fibrillation. CONCLUSIONS: Left atrial appendage function is depressed and spontaneous echo contrast more frequent in patients with atrial flutter and intermittent atrial fibrillation, as opposed to patients with pure atrial flutter. These data support the concept that patients with atrial flutter and intermittent atrial fibrillation have an increased risk of thromboembolic events and should therefore receive adequate anticoagulant treatment.

Aged↗

Right atrial appendage function in patients with chronic nonvalvular atrial fibrillation.

To assess right atrial appendage (RAA) flow and its possible relationship to left atrial appendage (LAA) flow in chronic nonvalvular atrial fibrillation (AF), transesophageal echocardiography (TEE) was performed in 26 patients with chronic nonvalvular AF (group I). For the purpose of comparison, an additional group of 27 patients with chronic valvular AF due to mitral stenosis (group II) was analyzed. The clinically estimated duration of AF in group I was significantly longer than that of group II (8.7+/-3.4 versus 2.7+/-1.1 years). Although right atrial size and RAA maximal area were larger in group I than those in group II, left atrial size was larger in group II than that in group I. Group II had larger LAA maximal areas than group I, but this difference did not reach statistical significance. The two groups were not different with respect to the RAA or LAA emptying velocities. Significant correlations were observed between echocardiographic parameters of the two atria in patients with nonvalvular AF (r range, 0.4 to 0.7). In contrast, in patients with valvular AF, no correlation was observed between the echocardiographic parameters of the two atria (appendage emptying velocity, r = 0.38, p = 0.051; atrial size, r = -0.03, p = 0.89; maximal appendage area, r = 0.07, p = 0.75, respectively). There were no significant differences in the presence of right and left atrial spontaneous echo contrast and thrombus between the groups. All of the right and left atrial thrombi were confined to their respective appendages and were found in the atria with spontaneous echo contrast. Both RAA and LAA thrombi were present in one patient. In conclusion, our findings suggest that AF could affect both atria equally in nonvalvular AF, in contrast to valvular AF. Therefore, the assessment of RAA function as well as LAA may be important in patients with chronic nonvalvular AF.

Aged↗

Transesophageal echocardiography in the diagnosis of left atrial appendage aneurysm.

Intrapericardial left atrial appendage aneurysm is rare. We describe the transthoracic and transesophageal echocardiographic findings in a 42-year-old man with atrial arrhythmia and an abnormal left atrial appendage on chest roentgenogram. Presence of an intrapericardial left atrial appendage aneurysm was confirmed at surgery.

Adult↗

Pathophysiologic correlates of thromboembolism in nonvalvular atrial fibrillation: I. Reduced flow velocity in the left atrial appendage (The Stroke Prevention in Atrial Fibrillation [SPAF-III] study).

Stroke associated with atrial fibrillation (AF) is mainly due to embolism of thrombus formed during stasis of blood in the left atrial appendage (LAA). Pathophysiologic correlates of appendage flow velocity as assessed by transesophageal echocardiography (TEE) in patients with AF have not been defined. To evaluate the hypothesis that reduced velocity is associated with spontaneous echocardiographic contrast and thrombus in the LAA and with clinical embolic events, we measured LAA flow velocity by TEE in 721 patients with nonvalvular AF entering the Stroke Prevention in Atrial Fibrillation (SPAF-III) study. Patient features, TEE findings, and subsequent cardioembolic events were correlated with velocity by multivariate analysis. Patients in AF during TEE displayed lower peak antegrade (emptying) flow velocity (Anu(p)) than those with intermittent AF in sinus rhythm during TEE (33 cm/s vs 61 cm/s, respectively, P <.0001). Anu(p) < 20 cm/s was associated with dense spontaneous echocardiographic contrast (P <.001), appendage thrombus (P <.01), and subsequent cardioembolic events (P <.01). Independent predictors of Anu(p) < 20 cm/s included age (P =.009), systolic blood pressure (P <.001), sustained AF (P =.01), ischemic heart disease (P =.01), and left atrial area (P =.04). Multivariate analysis found both Anu(p) <20 cm/s (relative risk 2.6, P =.02) and clinical risk factors (relative risk 3.3, P =.002) independently associated with LAA thrombus. LAA Anu(p) is reduced in AF and associated with spontaneous echocardiographic contrast, appendage thrombus, and cardioembolic stroke. Systolic hypertension and aortic atherosclerosis, independent clinical predictors of stroke in patients with AF, also correlated with LAA Anu(p). Our results support the role of reduced LAA Anu(p) in the generation of stasis, thrombus formation, and embolism in patients with AF, although other mechanisms also contribute to stroke.

Aged↗

Contribution of the ventricles and the atrial appendages to the elevation of plasma atrial natriuretic factor (ANF) during pacing-induced heart failure in conscious dogs.

The goal of our study was to determine whether the elevation in plasma ANF was produced by the atrial appendages or ventricular tissue during pacing-induced heart failure in chronically instrumented conscious dogs (sham) or dogs with bilateral atrial appendectomy. Acute volume expansion caused a significant elevation of plasma ANF from 80 +/- 8 to 149 +/- 26 pg/ml (p < 0.01) in sham dogs, but caused no significant change from 67 +/- 7 to 84 +/- 8 pg/ml in atrial appendectomized dogs. There were increases in left ventricular end-diastolic pressure (LVEDP) and left atrial pressure (LAP) in both groups of dogs. After rapid left ventricular pacing (210-240 beats/min) for 4 weeks to induce heart failure, dogs in both groups had tachycardia, elevated LVEDP and higher LAP. Plasma ANF was increased by 250% to 283 +/- 64 pg/ml (p < 0.01) in sham dogs, and only 40% to 94 +/- 15 pg/ml (p > 0.05) in atrial appendectomized dogs. In response to volume expansion, there were further increases in LVEDP and LAP in both groups of dogs, but plasma ANF was not elevated (288 +/- 39 pg/ml) in sham dogs and only slightly increased (132 +/- 7 pg/ml) in atrial appendectomized dogs. Our results suggest that, during pacing-induced heart failure, the atrial appendages are the major source of elevated plasma ANF, and the remaining atrial and ventricular tissue, even when maximally stretched, can only modestly increase plasma ANF.

Animals↗

Morphology of the left atrial appendage.

BACKGROUND: When examining the left atrial appendage by transesophageal echocardiography, differences in size and shape of the left atrial appendage are to be observed. The study was carried out with the aim of investigating the morphology of the left atrial appendage and to find associations with pathologic cardiac findings. METHODS AND RESULTS: In 220 cases (106 female, 114 male, mean age 72 +/- 13 years) a cast of the left atrial appendage was made after the post mortem examination by using synthetic resin. In 198 cases an ECG was available (sinus rhythm n = 143, atrial fibrillation n = 55). The casts were described in respect to course and ramifications of the principal axis. The casts were measured concerning orifice diameters, outline, and volume. Most frequently (42%) the course of the principal axis was angulated below 100 degrees. More than five ramifications of the principal axis were found in 56% of the casts. The volume ranged from 770-19,270 mm3 (mean 5,220 +/- 3,041). When comparing the clinical and autopsy-data of the patients with the morphology of the casts, associations could be found between the volume of the casts and atrial fibrillation (7,060 mm3 as compared to 4,645 mm3 in sinus rhythm, P < 0.01), left ventricular hypertrophy (5,740 mm3 as compared to 4,639 mm3 without hypertrophy, P < 0.01), myocardial scars (5,923 mm3 as compared to 4,891 mm3 without scars, P < 0.05), closed foramen ovale (5,515 mm3 as compared to 4,037 mm3 with patent foramen ovale, P < 0.01), and left atrial appendage thrombi (8,566 mm3 as compared to 5,027 mm3 without thrombi, P < 0.01). CONCLUSION: Left atrial appendages are formations greatly varying in volume and shape. This variability should be considered when interpreting images of the left atrial appendage, and in particular when diagnosing thrombi.

Adult↗

Blood flow in the left atrial appendage and embolic stroke in nonvalvular atrial fibrillation.

It is unclear if low flow velocity in the left atrial appendage (LAA) is a predisposing factor to stroke in patients with nonvalvular atrial fibrillation (NVAF). We investigated flow velocity in the LAA in NVAF patients in relation to a past history of stroke and other potential embolic sources. We measured and analyzed peak flow velocities into (FV-in) and out of (FV-out) the LAA in a middle portion of the LAA in 35 NVAF patients by transesophageal echocardiography (TEE). We divided the NVAF patients into 3 groups: the Eaf group had a history of embolic stroke without any other potential embolic sources; the Emulti group had other potential embolic sources, and the control group had no embolic history. FV-in and FV-out in the Eaf group (12.3 +/- 6.7 and 10.2 +/- 7.3 cm/s) were significantly lower than those in the control group (24.3 +/- 11.3 and 19.9 +/- 8.8 cm/s; multicomparison Scheffé's test, p = 0.0123 and 0.0395, respectively). The Emulti group varied in those values from less than 5 to above 35. Low flow velocity in the LAA seems to be a predisposing factor for stroke in NVAF patients without any other sources of emboli.

Aged↗

Complete correction of transposition of the great arteries with left juxtaposition of the atrial appendages.

Juxtaposition of the atrial appendages is an uncommon anomaly which is usually associated with transposition of the great arteries. Experience with five patients with transposition of the great arteries in combination with juxtaposition of the atrial appendages in whom Mustard's operation was performed is reviewed. Technically, the existence of juxtaposition of the atrial appendages in corrective surgery for transposition does not present any additional surgical problems. Emphasis is placed on the advantages of early complete correction, avoiding the need for palliative procedure.

Aorta↗