PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Audiometry, Pure-Tone”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Ossicular abnormalities in Down's syndrome.

Down's syndrome has been associated with hearing loss and otitis media. Because of difficulty in examination, however, there have been few detailed otologic studies on this population. An understanding of the nature and frequency of ear disease in Down's syndrome is important, since it is common and occurs in more than one in every 600 live births. To define the aural manifestation of Down's syndrome, complete otologic and audiometric examination was performed on 107 consecutive patients. This included micropneumatic otoscopy, pure-tone and speech audiometry, impedance tympanometry, and, in some cases, electronystagmography. Deficient hearing was found in 64% of these patients, and of these hearing losses, 83% were conductive. Surprisingly, middle ear effusion or tympanic membrane perforation accounted for only 60% of the conductive hearing losses. This finding prompted us to examine five temporal bones of children with Down's syndrome. These histologic sections revealed middle ear abnormalities including fixation and superstructure deformity of the stapes and dehiscence of the fallopian canal. Operative findings in 16 procedures on patients with Down's syndrome and conductive hearing loss suport those findings.

Adolescent↗

Pure-tone and tympanometric screening: an ideal pair in identification audiometry.

A population of 140 fourth graders participated in a combined audiometric and tympanometric screening project. Pass/fail criteria were established for both subtests. The children were compared between the two tests with the following findings: (1) 52.2% passed both tasks and 5.0% failed both; (2) 36.4% passed the pure-tone task and failed the tympanometric procedure; and (3) 6.4% failed the pure-tone observation and passed the tympanometric study. Of the total population, 42.8% were inconsistent for the norms established for the two tasks. Since the ideal goal of a hearing screening task is to locate children with hearing losses and/or medically related hearing problems, the routine use of tympanometric screening as an integral part of a hearing conservation program is proposed.

Acoustic Impedance Tests↗

A comparison of two response-reinforcement methods in pure-tone testing of the retarded.

The purpose of this study was to determine whether a visual reward method or play audiometry is a better motivator in eliciting the lowest possible pure-tone thresholds from a group of Down's syndrome adults. Thresholds were obtained at 250, 500, 2000, 4000, and 6000 Hz for both procedures using a modified ascending method. The method of testing was constructed such that each of the two procedures served as a comparison for validity of the other. The level of significant difference between the play audiometry and the visual reward method was determined using the Sign Test. In each case, there appeared to be a significant difference between the two tests, but the difference was attributed to the order of administration of the tests and practice rather than by the tests themselves. The data obtained suggests that more accurate auditory thresholds may be determined by administering two pure-tone tests and accepting the second as most valid.

Adolescent↗

Measurement of speech thresholds of Spanish-speaking children by non-Spanish speaking clinicians.

This study investigated the feasibility of a prerecorded speech threshold procedure that was used in a picture-pointing format, and was administered to Spanish-speaking children by non-Spanish-speaking clinicians. The derived Spanish word list was compared for equivalency to English spondees on a group of bilingual adults. The test, administered to 16 children ages three to six years, resulted in good agreement between SRT and pure-tone average. The test was found to be feasible, rapid, and reliable.

Adult↗

Hearing threshold for a decaying oscillatory waveform.

Hearing thresholds for a damped wave signal are measured at 8 frequencies from .35 -- 4 kc/s, and compared with hearing thresholds for pure-tone signals of the same frequencies. Hearing threshold for a damped wave signal is expressed in peak db re 20 uPa. Differences range somewhat irregularly from 8.6 to 19.6 db in favor of pure-tone signals. The difference between both threshold levels is described by a simple model.

Adolescent↗

[The importance of the "contingent negative variation" (CNV) for audiometry (author's transl)].

Previous proofs of "central processes" in hearing were based on the determination of the late "auditory evoked potentials" (AEP's: 50--300 ms) in EEG. The appearance of AEP's in different sleep stages raises the question, if the AEP actually conscious hearing. Since the discovery of the "Contingent Negative Variation" (CNV), as a potential depending on conscious and cognitive factors, an appropriate "instrument" is available to solve this problem. Using the CNV-technique three proofs of central auditory perception are described and discussed: a) "The objective proof of the perception of pure-tones", useful for threshold determination, test in the case of simulation and central hearing disorders. b) "The objective proof of the perception of stimulus-changes", useful for exact determination of differential thresholds for frequencies or intensities. c) "The objective speech audiometry", proof of speech comprehension, useful in case of aphasia and simulation.

Auditory Perception↗

Comparison of pure-tone, warble-tone and narrow-band noise thresholds of young normal-hearing children.

Pure-tone, warble-tone, and narrow-band noise thresholds were compared in terms of sensitivity and clinical test-retest reliability. Eighty normal-hearing young children, equally divided in four discrete age levels (3 1/2, 4 1/2, 5 1/2, and 6 1/2 years) were examined. Thresholds were ranked from most to least sensitive as follows: warble-tone, pure-tone, and narrow-band noise. Test-retest reliability was equivalent for all three stimuli. Clinical implications are discussed.

Acoustic Stimulation↗

Backward and forward masking in listeners with severe sensorineural hearing loss.

Using synthetic stimuli, backward and forward masking by a first-formant stimulus were measured for two tasks: (1) discrimination of a second-formant transition and (2) pure-tone detection. 16 listeners with moderate to severe sensorineural hearing impairment were studied. Many of the listeners showed backward and forward discrimination masking, sometimes extending as far as 200 ms before or after the first-formant interval. There were large individual differences in degree and temporal extent of masking. The masking contribution of sensitivity shifts, as indicated by pure-tone detection levels, appeared to be limited to a range of only 50 ms before or after the first-formant masker.

Acoustic Stimulation↗

Pure tone delayed auditory feedback: effect of instructions.

This study compared the effect of instructions to the subject upon key tapping performance with pure-tone delayed auditory feedback. One set of instructions stressed the importance of maintaining tapping rate whereas a second set emphasized consistency of the pattern. A third set stressed rate and pattern equality. The results lead to the recommendation that instructions stress equally both rate and pattern consistency.

Acoustic Stimulation↗

Calibration force levels for bone conduction vibrators.

Two bone conduction vibrators (Radioear B71 and B72) and a headband (Radioear P-3333) have been developed to meet specifications of both the International Electrotechnical Commission and the American National Standard Institute. Pure-tone thresholds for air conduction and bone conduction were obtained from 24 normal-hearing young adults at audiometric frequencies between 250 and 4000 Hz. Results of this study are in good agreement with the standard air conduction threshold sound pressure levels (ANSI) and with bone conduction threshold force levels reported in the literature.

Adult↗

Evaluation of a clinical method for measuring comfortable loudness for speech.

The reliability of a clinical method for measuring most comfortable loudness for speech was evaluated on 100 subjects with sensorineural hearing loss. The method uses spondaic words as the test stimuli. The test-retest reliability was determined for an ascending and descending approach mode for all 100 subjects as well as for subgroups categorized on the basis of severity of hearing loss and pure-tone configuration. Results indicated that reliability was not affected by approach mode, hearing loss severity, or pure-tone configuration. Test-retest differences were not significant and test-retest correlations were high (r = 0.73 to 0.93) across all subgroup categories. Clinical reliability was demonstrated by the high percentages (85 to 92%) of subjects who had test-retest differences no greater +/-5 dB. The procedure is rapid, uses no special equipment, is easily performed, and is reliable. Thus, it is recommended as the preferred clinical procedure.

Adult↗

Age effect in hearing - a comparative analysis of published threshold data.

Numerical data from the literature on presbyacusis, in the form of pure-tone hearing threshold levels as a function of age, are subjected to critical evaluation and analysis. A formula is derived for predicting the age effect for otologically screened groups of males and females. Further, the complete distribution of hearing levels for each audiometric frequency in the range 0.125-12 kHz and at any age can be estimated with the aid of tabulated coefficients and some simple rules. The study was undertaken in connection with the work of ISO on standardization of normative audiometric data.

Adult↗

Two experiments on subtle mid-frequency hearing loss and its influence on word discrimination in noise-exposed listeners.

The present study consisted of two experiments. Experiment I was directed toward the detection of subtle mid-frequency cochlear dysfunction and the determination of word discrimination in noise for persons with noise-induced hearing loss. The presence of significantly elevated aural-overload thresholds, consistent with the presence of cochlear pathology in regions of normal pure-tone sensitivity, confirmed previous findings obtained with this subject population by other investigators. In addition, a marked reduction in word discrimination was observed in the presence of a background of competing noise. For experiment II, normal hearers listened to consonant-nucleus-consonant monosyllables filtered to match the mean audiometric configuration of the noise-exposed subjects in experiment I. Results showed significantly better performance with these filtered words by the normally hearing subjects than that by the noise-exposed group for unfiltered materials. The results of the second experiment were interpreted as providing further support for the presence of subtle auditory dysfunction in the mid-frequencies despite normal threshold sensitivity in this same frequency region.

Acoustic Stimulation↗

Cochlear initiation site of the frequency-following response: a study of patients with sensorineural hearing loss.

The cochlear initiation of the frequency-following response (FFR) was assessed by comparing the FFR thresholds to the pure-tone thresholds in four groups of patients suffering from different forms of sensorineural hearing loss. The groups consisted of patients suffering from (1) pure high-frequency hearing losses; (2) high-frequency hearing losses mixed with moderate low-frequency losses; (3) flat hearing losses, and (4)low-frequency hearing losses. Across groups, the pattern of thresholds of the FFR evoked by 500-Hz tome bursts paralleled the pattern of pure-tone thresholds only for the low frequencies- not the high frequencies. In order to clarify the interpretation of this result, a high-pass masking experiment was performed on patients with low-frequency hearing losses. High-pass masking noise did not affect the FFR thresholds to 500-Hz tone burst, but it produced a phase shift of the FFR at stronger intensity levels. The data are interpreted as strongly supporting the view that the FFR at low levels is initiated primarily by activity in the apical portion of the cochlea.

Acoustic Stimulation↗

Auditory nerve and brain stem volume-conducted potentials evoked by pure-tone pips in the CBA/J laboratory mouse.

The short latency (less then 10 ms) auditory nerve and brain stem evoked potentials of Jewett were examined in the inbred CBA/J laboratory mouse. Tone pips, at nine frequencies from 4 to 64 kHz, were used to determine auditory nerve evoked potential (P1) thresholds. Maximum sensitivity occurred at 32 kHz, and a second sensitive area was seen at 56 kHz. With the exception of 32 kHz, as stimulus frequencies were increased in octave intervals, the 90 dB P1 amplitude also increased. P1 latency decreased as the stimulus frequency was increased up to 32 kHz, but this trend reversed with further increases of frequency. However, the P1 amplitude-latency function produced a better agreement of latency and frequency with the travelling wave theory for amplitudes less than 1 micro V, while amplitudes from 2 to 8 micro V were independent of frequency. Latency and amplitude input-output functions for responses from the four auditory brain stem loci suggest that auditory information is differentially processed as a function of frequency at each level, This is especially true for the inferior colliculus, which is most sensitive to 8-KHz stimuli.

Acoustic Stimulation↗

Changes in auditory perception in the menstrual cycle.

In a attempt to specify the critical functional components involved in the menstrual fluctuation of the upper frequency limit of the binaural beat we have obtained evidence of better performance in a variety of tasks at period and mid-cycle than at other times. These tasks include detection of physical beating, low-frequency octave matching, and lateralisation of clicks having interaural time delays in the 100 musec region. Continuous pure-tone frequency discrimination did not show a significant cyclical pattern overall but there was a tendency for low-frequency discrimination to show the described pattern. An attempt is made to reconcile some of these results with those of Wynn (1973) on absolute pitch, in terms of possible physiological and biochemical correlates. Three conclusions can be drawn: (1) The representations both of low-frequency tones and of the interaural time differences involved in some localisation tasks are particularly susceptible to alteration by the biochemical changes of the menstrual cycle: (2) The changes underlying perceptual variations are multiple, and inevitably confounded in any single task. (3) The distinction between the sensitivity and bias parameters of performance appears to be valuable in specifying menstrual effects. Several further lines of enquiry are suggested, but methodological difficulties in cycle research make it likely that more progress will come from better understanding of the physiological bases of psychoacoustic tasks using other methods, rather than from investigating natural menstrual effects.

Adult↗

The influence of audiometric configuration on pure-tone, warble-tone and narrow-band noise thresholds of adults with sensorineural hearing losses.

Thresholds measurements for pure tones, warble tones, and narrow-band noise were compared for adult sensorineural hearing-impaired subjects with gradual and sharp audiometric configurations. Results demonstrated that audiometric configuration does not significantly affect the relationship between pure tones and warble tones but does affect the relationship between pure tones and narrow-band noise. Differences were most apparent at the higher frequencies. Clinical implications are discussed.

Acoustic Stimulation↗