PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Copying Processes”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Variable copy number DNA sequences in rice.

We have cloned two types of variable copy number DNA sequences from the rice embryo genome. One of these sequences, which was cloned in pRB301, was amplified about 50-fold during callus formation and diminished in copy number to the embryonic level during regeneration. The other clone, named pRB401, showed the reciprocal pattern. The copy numbers of both sequences were changed even in the early developmental stage and eliminated from nuclear DNA along with growth of the plant. Sequencing analysis of the pRB301 insert revealed some open reading frames and direct repeat structures, but corresponding sequences were not identified in the EMBL and LASL DNA databases. Sequencing of the nuclear genomic fragment cloned in pRB401 revealed the presence of the 3'rps12-rps7 region of rice chloroplast DNA. Our observations suggest that during callus formation (dedifferentiation), regeneration and the growth process the copy numbers of some DNA sequences are variable and that nuclear integrated chloroplast DNA acts as a variable copy number sequence in the rice genome. Based on data showing a common sequence in mitochondria and chloroplast DNA of maize (Stern and Lonsdale 1982) and that the rps12 gene of tobacco chloroplast DNA is a divided gene (Torazawa et al. 1986), it is suggested that the sequence on the inverted repeat structure of chloroplast DNA may have the character of a movable genetic element.

Base Sequence↗

An evaluation of line quality in photocopied signatures.

Qualified forensic document examiners from Canada, USA, Great Britain and Australia participated in this study. They were sent one photocopied signature, together with a set of original known standards to evaluate the line quality of the photocopied signature and compare these characteristics with the standards. They were asked to assess the photocopies for the presence of tremor, hesitation, pen lifts, patching, blunt initial or terminal strokes, and abrupt changes in direction. The authors compared the assessments with the corresponding original signatures. It was possible to determine which line quality characteristics were the most difficult to detect, which indicia of simulation were concealed and what anomalies were introduced by the photocopying process. Results indicated that line quality characteristics can be identified in average quality photocopies. Furthermore, accurate judgements can be made regarding similarities and differences in line quality when comparing a photocopied signature with original known standards. In a few instances, ink line morphology was problematic when striation patterns and ink gooping were misinterpreted as pen lifts, hesitation and patching on the photocopies.

Copying Processes↗

Manual and computer-aided space analysis: a comparative study.

Recently, computers have been used to measure key landmarks from photocopies of upper and lower study models to increase simplicity, accuracy, and informatics. This is a comparative study to evaluate the accuracy and reliability of computer-aided space analysis. Data were collected from a series of randomly selected study models. All subjects had Angle Class I molar relationships with minor malocclusions such as crowding, rotations, or diastemas. Two investigators independently measured teeth on models with a Vernier gauge that had sharpened caliper tips. Intraexaminer and interexaminer reliability was determined at 0.2 mm. All teeth, to and including the first molars, were measured. Two photocopies of each set of models were made on a photostat machine (Xerox, Japan) and were coded. A template with a ruler was used, to allow the investigator to compensate for any reduction or enlargement error during the photocopying process. The mesiodistal sizes were measured with a digitizer, and results were processed by using a dedicated computer program. Evaluations were done in a double-blind manner. The nonparametric Wilcoxon signed rank test for paired observations to compare median differences between measurements was used. Intraexaminer digitized measurements were almost identical and differed (p < 0.0001) for only one measurement. However, interexaminer manual and digitized measurements differed significantly (p < 0.001) for 20 of the 24 teeth. Nineteen of these digitized tooth measurements were smaller. The mean arch length measurements differed by 4.7 mm (p < 0.0001) in the maxilla and by 3.1 mm (p < 0.0001) in the mandible. The difference between the manual and digitized analyses may be due to the photocopying process. The inability to accurately measure a three-dimensional study cast that has been duplicated in two dimensions, convex structure of teeth, curve of Spee, tooth inclination, and tooth position may play a role. The computer-aided measuring system is reliable, but accurate mesiodistal measurements cannot be made from photocopies of dental models. Manual measurements that use a calibrated gauge produce the most accurate, reliable, and reproducible results.

Calibration↗

Maintaining confidentiality: health care's ongoing dilemma.

Confidentiality of patient information is an ethical obligation of health care professionals. The exercise of confidentiality is not a simple process; it is dynamic rather than static and must be upgraded with changes in technology. This article discusses some of the common issues that arise in maintaining confidentiality in the health care environment, including spoken and written breaches of confidentiality, use of the computer, confidentiality as an ethical rather than legal obligation, and the use of programs in health care institutions to maintain confidentiality.

Attitude of Health Personnel↗

Converting a large photographic negative collection to digital form.

Like many media production facilities in recent years, we at the University of Arkansas for Medical Sciences' Media Services have made the transition from silver and wet photographic processes to digital production methods. During that process we found that many of our products had to be transferred from traditional to digital form. One major asset we had was a portrait negative file that contained about 13,000 photographic negatives of nearly 6,000 individuals. These negatives were of individuals currently on staff or who had had their portrait taken while on staff in the past. The oldest of these negatives went back twenty years. About 65 percent of the collection consisted of 4 x 5 black and white negatives and the rest evenly distributed between 120 and 35 mm film formats. Less than 20 percent of the entire collection was color.

Arkansas↗

Investigation and control of occupational hazards associated with the use of spirit duplicators.

A Health Hazard Evaluation was conducted by the National Institute for Occupational Safety and Health (NIOSH) to determine if vapors from duplicating fluid (99% methyl alcohol) used in direct-process spirit duplicating machines were causing adverse health effects among teacher aides, or had been responsible for the deaths of three former teacher aides. Death certificates and autopsy data were obtained and evaluated. A self-administered symptom questionnaire was distributed to current teacher aides (exposed group) and to a comparison group of teachers. Fifteen-minute breathing zone air samples for methyl alcohol vapor were collected at operator stations using an infrared gas analyzer. No information supported the claim that the three deaths were related to methyl alcohol exposure. Teacher aides reported significantly more blurred vision, headache, dizziness, and nausea than the comparison group. Concentrations of airborne methyl alcohol ranged from 365-3080 ppm; 15 of 21 measurements exceeded the NIOSH-recommended 15-minute exposure limit of 800 ppm. A mean 96% reduction in vapor concentration was accomplished using inexpensive enclosures and existing room exhaust systems.

Adult↗

Development of a high quality film duplication system using a laser digitizer: comparison with computed radiography.

A high quality film-duplication system was developed in order to improve the image quality of duplicated radiographs and to recover improperly exposed films. The system consists of a laser film digitizer, a laser film printer, a workstation, and a magneto-optical disk. Radiographs are digitized by the laser digitizer, processed by the computer for image enhancement, and then printed on a film by the laser printer. A nonlinear density-correction technique is employed in recovering improperly exposed radiographs using the H&D curve of the screen-film system. Using the new duplication system in our department, the average recovery rate was over 80% for chest and abdominal films rejected due to over- or underexposed. The basic imaging properties of the duplication system were compared with those of a Computed Radiography (CR) system and a conventional screen-film system. For low spatial frequencies, the MTF of the CR system is superior to that of the digital duplication system; however, for high spatial frequencies, the MTF of the duplication system is superior. The noise in the duplication system is about half of that in the CR system.

Biophysical Phenomena↗

Double-exposure duplication of preoperative and postoperative 2 X 2 transparencies.

Before and after photographs in plastic surgery are an essential part of the patient's record. They also provide visual data to supplement both primary and continuing education lectures. When successive photographs are used in lectures, a sharp visual memory is required to compare effectively the preoperative and postoperative photograph. The method presented in this article uses a specially constructed frame used as an accessory for one of the common commercial slide copiers. This device makes it possible to copy, duplicate, and frame preoperative and postoperative 2 X 2 transparencies onto a single 2 X 2 transparency without any additional work on the original, such as framing, cutting, and remounting. This technique leaves the original preoperative and postoperative 2 X 2 transparency slides intact for possible use elsewhere in the same lecture or subsequent lectures on the same subject.

Audiovisual Aids↗

Acute-onset sarcoidosis presenting as workplace-related hyperreactive airway disease.

Bechtel et al [Am Rev Respir Dis 124:759-761, 1981] have reported a high prevalence of positive methacholine challenge tests in patients with sarcoidosis. We report a patient with sarcoidosis who was identified because of symptoms resulting from exposure to workplace irritants. The presence of hyperreactive airways was confirmed by a positive methacholine challenge.

Adult↗

ELF magnetic field exposures in an office environment.

Potential exposures to extremely low frequency (ELF) magnetic fields were investigated in response to worker concerns about an apparent increased spontaneous abortion risk in a payroll office environment. Concern in this office centered on the use of video display terminals (VDTs), which have been investigated as a potential cause of adverse reproductive outcomes among women. In this investigation, magnetic field sources were evaluated using a hand-held survey meter. Emdex datalogging dosimeters were also used to determine full shift personal exposures for 15 women working in the payroll area. On average, the exposures of workers to ELF magnetic fields in the payroll office area ranged from 1.0 to 6.5 mG with a mean of 3.2 +/- 1.5 mG. The results of this study indicate that many sources of ELF magnetic fields, including printers, photocopiers, and the electrical distribution system, can contribute to a worker's exposure in an office environment.

Computer Terminals↗

An evaluation of employee exposure to volatile organic compounds in three photocopy centers.

Personal and area samples from three copy centres were collected in thermal desorption tubes and analyzed using gas chromatography-mass spectrometry. Real-time personal total volatile organic compounds (TVOC) were measured using a data-logging photoionization detector. Fifty-four different VOCs were detected in the area samples. The maximum concentration measured was 1132.0 ppb (toluene, copy center 3, day 1). Thirty-eight VOCs were detected in the personal samples and concentrations ranged from 0.1 ppb (1,1-biphenyl, p-dichlorobenzene, propylbenzene, styrene, and tetrachloroethylene) to 689.6 ppb (toluene). Real-time TVOC measurements indicated daily fluctuations in exposure, ranging from <71 to 21,300 ppb. The time-weighted average exposures for the photocopier operators on days 1 and 2 were 235 and 266 ppb and 6155 and 3683 ppb, in copy centers 2 and 3, respectively. Personal exposure measurements of individual VOCs were below accepted occupational standards and guidelines. For example, the maximum concentration was 0.3% of the permissible exposure limits (toluene, copy center 3). Exposures were highest in copy center 3; this is likely due to the presence of offset printing presses. It is concluded that photocopiers contribute a wide variety of VOCs to the indoor air of photocopy centers; however, exposures are at least 100 times below established standards.

Air Pollution, Indoor↗

Demonstration of digital radiographs by means of ink jet-printed paper copies: pilot study.

Different digital medical images have been printed on paper with a continuous ink jet printer, and the quality has been evaluated. The emphasis has been on digital chest radiographs from a computed radiography system. The ink jet printing technique is described as well as the handling of the image data from image source to printer. Different versions of paper prints and viewing conditions were compared to find the optimum alternative. The evaluation has been performed to maximize the quality of the paper images to make them conform with the corresponding film prints and monitor images as much as possible. The continuous ink jet technique offers high-quality prints on paper at a considerably lower cost per copy compared with the cost of a film print. With a future switch-over from diagnosing of digital images on film to diagnosing them on monitors, hard copies for demonstration purposes will occasionally be needed. This need can be filled by ink jet-printed paper copies.

Copying Processes↗