[A biomechanical study of the mechanical stress transmission of dental implants using finite element analysis. Part II. Experiments].

In the first part of this two-part study the possible uses of finite element analysis in studying the stress transmission of dental implants were reviewed. In the present second part our own experiments are presented. In the first series the effect of the geometric parameters and load types on mechanical stresses arising around cylindrical implants in bone were studied with 2D and 3D finite element analysis. In the second series the stress transmissions of various implant geometries were compared and an attempt was made to determine the optimal implant shape from the point of view of stress transmission.

Dental Implants↗

Application of finite element analysis in implant dentistry: a review of the literature.

Finite element analysis (FEA) has been used extensively to predict the biomechanical performance of various dental implant designs as well as the effect of clinical factors on implant success. By understanding the basic theory, method, application, and limitations of FEA in implant dentistry, the clinician will be better equipped to interpret results of FEA studies and extrapolate these results to clinical situations. This article reviews the current status of FEA applications in implant dentistry and discusses findings from FEA studies in relation to the bone-implant interface, the implant-prosthesis connection, and multiple-implant prostheses.

Biomechanical Phenomena↗

Local head roughening as a factor contributing to variability of total hip wear: a finite element analysis.

Large inter-patient variability in wear rate and wear direction have been a ubiquitous attribute of total hip arthroplasty (THA) cohorts. Since patients at the high end of the wear spectrum are of particular concern for osteolysis and loosening, it is important to understand why some individuals experience wear at a rate far in excess of their cohort average. An established computational model of polyethylene wear was used to test the hypothesis that, other factors being equal, clinically typical variability in regions of localized femoral head roughening could account for much of the variability observed clinically in both wear magnitude and wear direction. The model implemented the Archard abrasive/adhesive wear relationship, which incorporates contact stress, sliding distance, and (implicitly) bearing surface tribology. Systematic trials were conducted to explore the influences of head roughening severity, roughened area size, and roughened area location. The results showed that, given the postulated wear factor elevations, head roughening variability (conservatively) typical of retrieval specimens led to approximately a 30 degrees variation in wear direction, and approximately a 7-fold variation in volumetric wear rate. Since these data show that randomness in head scratching can account for otherwise-difficult-to-explain variations in wear direction and wear rate, third-body debris may be a key factor causing excessive wear in the most problematic subset of the THA population.

Acetabulum↗

Three-dimensional finite element analyses of four designs of a high-strength silicon nitride implant.

The effects of implant shape and size on the stress distribution around high-strength silicon nitride implants under vertical and oblique forces were determined using a three-dimensional finite element analysis. Finite element models were designed using as a basis the serial sections of the mandible. Using Auto-CAD software, the model simulated the placement of implants in the molar region of the left mandible. Results of the analyses demonstrated that mainly the implant root shape and the directions of bite forces influence the stress distributions in the supporting bone around each implant. Implant size is a lesser factor. The serrated implants presented a larger surface area to the bone than either the cylindrical or tapered implants, which resulted in lower compressive stress around the serrated implants. With increasing implant diameter and length, compressive stress decreased. The mean compressive stress distribution on the serrated implants was more flat (platykurtic) than on either the cylindrical or tapered implants. Results of studies on two load directions (vertical and oblique) showed that, in either case, the compressive stress in the cortical bone around the neck of the implant was higher than in the cancellous bone along the length of the implant. The most extreme principal compressive stress was found with oblique force. This study provides the first information on the relationship between shape of the silicon nitride implant and stress on the supporting bone.

Alveolar Process↗

MR validation of soft tissue mimicing phantom deformation as modeled by nonlinear finite element analysis.

A study of the applicability of nonlinear finite element analysis (FEA) to predict soft tissue deformation was validated with phase contrast magnetic resonance velocity imaging. A phantom of varying stiffness was placed in a special purpose, computer controlled MR compatible compression apparatus which provided precise, time varying compression with surface deformations on the order of 11%. The resulting motion was measured with MR velocity images acquired throughout the cycle of compression. The phantom geometry was modeled with a finite element mesh and the mechanical properties of the phantom material were measured and incorporated in the FEA model. The motion as calculated by the FEA model was compared to the motion measured with MRI and the results were found to vary with the material's Poisson's ratio and the coefficient of friction. A minimum difference was reached when the Poisson's ratio and coefficient of friction were set to 0.485 and 0.3, respectively. Under these conditions, the root mean square difference was found to be 14.4%.

Agar↗

Development of tissue level brain injury criteria by finite element analysis.

A three-dimensional finite element model of the direct cortical impact experiment was built and a preliminary validation against mechanical response was completed. The motion of the impactor was enforced in the model by applying the same acceleration history as that of the experimental impactor. A nonlinear contact surface algorithm was used for impactor-brain interface with the ABAQUS general purpose finite element program. The resulting motion of the impactor and the contacting node in the brain model confirmed that the impactor moved realistically and contacted the brain surface. The pressure generated in the model compared favorably with that measured by a pressure transducer in the experiment. The pattern of high shear deformation generated at the impact site in the model was similar to the pattern of contusion hemorrhage seen in the experiment. The pressure generated at the impact site propagated to the skull-brain boundary, especially, at the posterior margin of the cerebellum. Analysis of experimental data using a biomechanically validated finite element model will enable determination of tissue-level injury criteria for application in human brain models to predict head injury potential in contact, noncontact, or side impact situations.

Brain Injuries↗

Finite-element analysis of temperature rise and lesion formation from catheter ultrasound ablation transducers.

A model using finite-element analysis (FEA) has been developed to calculate the temperature rise in tissue from intracardiac ultrasound ablation catheters and to predict if this temperature rise is adequate for producing a lesion in the tissue. In the model, acoustic fields are simulated with Field II, and heat transfer is modeled with an FEA program. To validate the model, we compare its results to experimental results from an integrated, real-time three-dimensional (3-D) ultrasound imaging and ultrasound ablation catheter. The ultrasound ablation transducer is a ring transmitting at 10 MHz capable of producing an acoustic intensity of 16 W/cm2. It was used to ablate four lesions in tissue, and temperature rise as a function of time was monitored by embedded thermocouples. The average absolute difference between final temperatures predicted by FEA and those measured is 1.95 +/- 0.72 degrees C. Additionally, model and experimental lesion size are in good agreement. The model then is used to design a new ultrasound catheter with a 7.5 MHz linear phased array for ablation. Eight designs are modeled, and acoustic intensity, temperature rise, and ablation ability are compared.

Animals↗

Biomechanical comparison of lumbar spine with or without spina bifida occulta. A finite element analysis.

STUDY DESIGN: Biomechanical study using finite element model (FEM) of lumbar spine. OBJECTIVES: Very high coincidence of spina bifida occulta (SBO) has been reported more than in 60% of lumbar spondylolysis. The altered biomechanics due to SBO is one considerable factor for this coincidence. Thus, in this study, the biomechanical changes in the lumbar spine due to the presence of SBO were evaluated. SETTING: United States of America (USA). METHODS: An experimentally validated three-dimensional nonlinear FEM of the intact ligamentous L3-S1 segment was used and modified to simulate two kinds of SBO at L5. One model had SBO with no change in the length of the spinous process and the other had a small dysplastic spinous process. Von Mises stresses at pars interarticularis were analyzed in the six degrees of lumbar motion with 400 N axial compression, which simulates the standing position. The range of motion at L4/5 and L5/S1 were also calculated. RESULTS: It was observed that the stresses in all the models were similar, and there was no change in the highest stress value when compared to the intact model. The range of motion was also similar in all the models. The lumbar kinematics of SBO was thus shown to be similar to the intact model. CONCLUSION: SBO does not alter lumbar biomechanics with respect to stress and range of motion. The high coincidence of spondylolysis in spines with SBO may not be due to the mechanical factors.

Biomechanical Phenomena↗

Effects of total contact insoles on the plantar stress redistribution: a finite element analysis.

OBJECTIVE: To investigate the effects of total contact insoles on the plantar stress redistribution using three-dimensional finite element analysis. DESIGN: The efficacies of stress reduction and redistribution of two total contact insoles with different material combinations were compared with those of a regular flat insole used as a baseline condition. BACKGROUND: Many specially designed total contact insoles are currently used to reduce the high plantar pressure in diabetic patients. However, the design of total contact insoles is mostly empirical and little scientific evidence is available to provide a guideline for persons who prescribe such insoles. METHODS: To use three-dimensional finite element models of the foot together with insoles to investigate the effects of total contact insoles on the foot plantar pressure redistributions. Nonlinear foam material properties for the different insole materials and the contact behavior in the foot-insole interface were considered in the finite element analysis. RESULTS: Results showed that the peak and the average normal stresses were reduced in most of the plantar regions except the midfoot and the hallux region when total contact insoles were worn compared with that of the flat insole condition. The reduction ratios of the peak normal stress ranged from 19.8% to 56.8%. CONCLUSIONS: Finite element analysis results showed that the two sets of total contact insoles used in the current study can both reduce high pressures at regions such as heel and metatarsal heads and can redistribute the pressure to the midfoot region when compared with the flat insole condition. RELEVANCE: It is possible to simulate foot deformities, change in material properties, different ambulatory loading conditions, and different orthotic conditions by altering the finite element model in a relatively easy manner and these may be of interests to the medical professionals who treat foot-related problems.

Adult↗

Mechanical response to functional loading around the threads of retromolar endosseous implants utilized for orthodontic anchorage: coordinated histomorphometric and finite element analysis.

A 3-dimensional bone-implant finite element model was created. The objective was to further investigate the mechanical environment of cortical bone adjacent to the threads of a retromolar endosseous implant used for orthodontic anchorage to mesially translate mandibular molars in response to normal functional loading. This study emphasizes the stress invariants around and between the threads of the implant for future comparison to histomorphometric data from an ongoing clinical study. A strong stress pattern change was found immediately around the implant, which was reflected by a moderate change of stresses between the threads and a significant increase in stress at the tips of the threads.

Compressive Strength↗

Nonlinear finite-element analysis and biomechanical evaluation of the lumbar spine.

A finite-element analysis (FEA) model of an intact lumbar disc-body unit was generated. The vertebral body of the FEA model consisted of a solid tetrahedral core of trabecular bone surrounded by a cortical shell. The disc consisted of an incompressible nucleus surrounded by nonlinear annulus fibers embedded in a solid ground substance. The purpose was to create a FEA model suitable for clinical purposes as fracture assessment, instrumentation with pedicle screws, and bone remodeling. Testing of the FEA model was performed nonlinear for a number of loading conditions, and the results were compared with experimental data from the literature. The results showed good agreement. The formulation of the FEA model can be justified for the tested loading conditions.

Compressive Strength↗

Finite element analysis of fiber-reinforced fixed partial dentures.

Two-dimensional finite element models were created for a three-unit posterior fixed partial denture. An experimental resin-impregnated glass fiber was used as the fiber-reinforced composite (FRC) for the framework. The FRC was evaluated using varying combinations of position and thickness, alongside with two types of veneering composite. A load of 50 N simulating bite force was applied at the pontic in a vertical direction. Tensile stress was examined using a finite element analysis program. Model without FRC showed tensile stress concentrations within the veneering composite on the cervical side of the pontic--from the connector area to the bottom of the pontic. Model with FRC at the top of the pontic had almost the same stress distribution as the model without FRC. Models with 0.4-0.8 mm thick FRC positioned at the bottom of the pontic showed maximum tensile stresses reduced by 4-19% within the veneering composite.

Bite Force↗

Theory of force transducer design optimization for die wall stress measurement during tablet compaction: optimization and validation of split-web die using finite element analysis.

PURPOSE: 1) To illustrate how computer aided engineering stress analysis can be used to improve the transducer design process for tablet press instrumentation; 2) to use these optimal design procedures for the geometric optimization of a cylindrical, segmented, and a novel split-web die design. Discussion includes the selection of optimal die wall thickness, segment cutting angle, strain gage placement, Wheatstone bridge configuration, and the influence of tablet height and position within the die on signal output. METHODS: Stress analysis was done with a finite element analysis (FEA) software package running on a personal computer. RESULTS: For the segmented die, the admissible range of die wall thicknesses depends upon cutting angle; the signal output is non-linear because the stress distribution in the die wall is influenced by tablet height and position within the die. For the split-web die, the optimal configuration consists of a 1/8 in. sensing web with a strain gage located at the peak of the sensing-web arch. This prototype had a linear calibration curve (r2 = 0.999) with no hysteresis. Radial versus axial stress transmission curves for: starch and sodium chloride were consistent with literature data. CONCLUSIONS: Finite element analysis (FEA) is a useful numerical tool for the systematic optimization of tablet press instrumentation. By enclosing the sensing web of a three layered die design in a cylinder, the split-web design can be directly mounted without modification of the die table.

Drug Design↗

Finite-element analysis of balloon angioplasty.

Finite-element modelling is used to simulate the response of atherosclerotic arteries to a balloon angioplasty procedure. Material properties for the normal wall are derived from experimental data, and the properties of the plaque are varied over a wide range. Comparison with experimental data shows that the normal arterial wall can be appropriately modelled using a hyperelastic material definition. Large strain, non-linear analysis was used to simulate the dilatation of three typical plaque configurations by an angioplasty balloon. Stress contour plots are presented for each configuration. Results show good agreement with previous histologic studies.

Angioplasty, Balloon, Coronary↗

In vivo determination of contact areas and pressure of the femorotibial joint using non-linear finite element analysis.

OBJECTIVES: A three dimensional finite element model of the femorotibial joint was developed from MR images in order to quantify in vivo the articular contact. BACKGROUND: Most of femorotibial joint models were elaborated from in vitro experiments. The stereophotogrammetric technique was used to model the geometry and mechanical testing had been performed to quantify the material properties. METHOD: MR images were performed on a normal adult knee joint, in extension position. An image processing software developed in our laboratory allowed our model geometry to be constructed, and a pre-and post-processing software allowed us to develop a three-dimensional finite element model. Experimental contact area values were obtained using a method developed in our laboratory. Theoretical contact values, areas and hydrostatic pressure were obtained with a non-linear finite element computation using a non-linear software solver. RESULTS: The results show a good agreement between theoretical and experimental contact area values. Hydrostatic pressure was found to be higher at the medial contact than at the lateral contact. CONCLUSION: This study validated the use of contact elements to quantify the contact areas. The model permitted the body weight simulation to understand the role of the menisci. RELEVANCE: The clinical application of the study was to develop a method evaluating the influence of rotational abnormalities of the lower limbs on the knee joint at short- and long-term. This consisted of quantifying the contact area and pressure values and their migration.

Journal Article↗

Finite-element analysis of capacitive micromachined ultrasonic transducers.

In this paper, we present the results of finite-element analysis performed to investigate capacitive micromachined ultrasonic transducers (CMUTs). Both three-dimensional (3-D) and 2-D models were developed using a commercially available finite-element modeling (FEM) software. Depending on the dimensionality of the model, the membranes were constructed using plane or shell elements. The electrostatic gap was modeled using many parallel plate transducers. An axisymmetric model for a single membrane was built; the electrical input impedance of the device then was calculated in vacuum to investigate series and parallel resonant frequencies, where the input impedance has a minimum and a maximum, respectively. A method for decomposing the membrane capacitance into parasitic and active parts was demonstrated, and it was shown that the parallel resonant frequency shifted down with increased biased voltage. Calculations then were performed for immersion transducers. Acoustic wave propagation was simulated in the immersion medium, using appropriate elements in a 3-D model. Absorbing boundaries were implemented to avoid the reflections at the end of the medium mesh. One row of an array element, modeled with appropriate boundary conditions, was used to calculate the output pressure. The results were compared with a simpler model: a single membrane in immersion, with symmetry boundary conditions on the sidewalls that cause the calculations to reflect the properties of an infinitely large array. A 2-D model then was developed to demonstrate the effect of membrane dimensions on the output pressure and bandwidth. Our calculations revealed that the small signal transmit pressure was inversely proportional to the square root of gap height. We also compared FEM results with analytical and experimental results.

Computer Simulation↗

Selection of fixation devices in proximal femur rotational osteotomy: clinical complications and finite element analysis.

OBJECTIVE: To compare the postoperative stability between large cancellous screws fixation and dynamic hip screws fixation in transtrochanteric rotational osteotomy. DESIGN: Finite element analysis was designed to validate the clinical outcomes of fixation failure in transtrochanteric rotational osteotomy. BACKGROUND: From 1997 to 2000, transtrochanteric rotational osteotomy had been done in 20 osteonecrotic hips. Fixation with large cancellous screws as suggested by Sugioka had been used in the first five hips. Unfortunately, fixation failures were encountered in all of the five cases. The fixation mode was then shifted to a combination of plate and screws, no fixation failure had been observed postoperatively. A finite element analysis was designed to investigate the causes of fixation failure. METHODS: Finite element models for four dynamic hip screw instrumented femora and four large screws instrumented femora simulating four different levels of bone cut were created. The von Mises stress distributions of each model were analyzed and compared for a loading condition simulating single-legged stance. RESULTS: Analysis results confirmed our clinical observation that fixation with screws had higher stress concentration on the proximal femur. Improper bone cut, especially those that are too distal from the intertrochanteric line, had higher risks of fixation failure. CONCLUSIONS: Transtrochanteric rotational osteotomy is a technically demanding procedure such that surgical principles should be abided carefully to avoid catastrophic complications. RELEVANCE: Finite element analysis results demonstrated that dynamic hip screw fixation provides better stability and prevents fixation failure that corresponds with the clinical observation.

Adult↗

Computed tomography-based finite element analysis predicts failure loads and fracture patterns for vertebral sections.

Computed tomography-based finite element analysis represents a powerful research tool for investigating the mechanics of skeletal fractures. To provide evidence that this technique can be used to predict failure loads and fracture patterns for bone structures, we compared the observed and predicted failure behaviors of 18 midsagittal sections, 10 mm thick, cut from human vertebral bodies. The specimens were scanned by computed tomography, and finite element models were generated with use of empirically determined density-property relations to assign element-specific material properties. The specimens were loaded to failure in uniaxial compression, and the models were analyzed under matching conditions. The models provided predictions of yield load that were strongly correlated with experimentally measured values (r2 > 0.86) and were typically within 25% of measured values. Predicted stiffness values were moderately correlated with measured values, but large absolute differences existed between them. Comparisons between regions of observed fracture and of high predicted strain indicated that strain was an accurate indicator of the pattern of local fracture in more than two-thirds of the bone specimens. In addition, strain contour plots provided better indicators of local fracture than did stress plots in these heterogeneous bone structures. We conclude that computed tomography-based finite element analysis can be used successfully to predict both global and local failure behavior of simplified skeletal structures.

Adult↗