Reverse phase HPLC for polar lipids. Simple and selective HPLC procedures for analysis of phospholipid-based derivatives of valproic acid and various non-steroidal anti-inflammatory drugs.

DP-VPA (SPD 421) is a new compound, where valproic acid is chemically bound to lecithin. It is a novel prodrug of valproic acid with targeted action for the treatment of epilepsy. RP-HPLC stability indicating method has been developed for this and relative compounds. Versatile detection techniques could be used with these LC procedures. The absence of non-volatile components in the mobile phase allows running the method with evaporative light scattering and MS-detectors. The method appeared to be sensitive, selective, reproducible, and stability indicating. It could be easily upgraded to bioanalytical procedures applying LC-MS technique. The method could be used as 'generic' for numerous compounds having similar design of the molecules, such as lecithin-based derivatives of diclofenac, naproxen, ibuprofen, and indometacin. The strategy of HPLC method development for polar lipids is discussed.

Anti-Inflammatory Agents, Non-Steroidal↗

Micro-HPLC and standard-size HPLC for the separation of peptide stereoisomers employing an ion-exchange principle.

Standard-size (4 mm ID) and micro-HPLC columns (0.5 mm ID) packed with a quinine-based ion-exchange type chiral stationary phase are comparatively evaluated for the separation of peptide enantiomers with up to six amino acid residues. The results show that downscaling the separation system in order to gain the advantages of miniaturized HPLC is possible without sacrificing separation power. Further, five different N-terminal protections (3,5-dinitrobenzoyl, 2,4-dinitrophenyl, 3,5-dinitrobenzyloxycarbonyl, carbazole-9-carbonyl, and 9-fluorenylmethoxycarbonyl) of the analytes are investigated regarding their effect on enantioselectivity. A comparison between a hydro-organic and a polar-organic mobile phase is also reported. The enantiomers of the peptides containing one to four amino acid residues were baseline resolved, while for the penta- and hexamers only partial separations were possible. In addition, all four stereoisomers of alanylalanine could be baseline separated.

Chromatography, High Pressure Liquid↗

Validation of a reversed-phase HPLC method for 1,10-phenanthroline-5,6-dione and analysis of its impurities by HPLC-MS.

A reversed-phase HPLC analytical method for the assay of 1,10-phenanthroline-5,6-dione (I) has been developed and validated. A C18 column (150 x 4.6 mm; 5 microm) was employed together with a mobile phase of methanol-water (50:50, v/v) containing 0.1% triethylamine. UV detection was performed at 254 nm. Dione (I) eluted as a spectrally pure peak resolved from its impurities allowing the method to be applied to the purity evaluation of samples obtained via two synthetic routes. In addition, 4,5-diazafluoren-9-one (V) was identified as the main impurity by employing the method in HPLC-MS mode with photodiode array UV detection.

Antineoplastic Agents↗

Retention of ionizable compounds on HPLC. 12. The properties of liquid chromatography buffers in acetonitrile-water mobile phases that influence HPLC retention.

The addition of acetonitrile to aqueous buffers to prepare RP HPLC mobile phases changes the buffer properties (pH and buffer capacity). This variation is studied for ace tate, phosphate, phthalate, citrate, and ammonia buffers in acetonitrile-water mixtures up to 60% in acetonitrile (v/v). Equations are proposed to relate pH and buffer capacity change of these buffers to the initial aqueous pH value and to the volume fraction of acetonitrile added. It is demonstrated that the pH change of the buffer depends not only on the initial aqueous pH of the buffer and on the percentage of acetonitrile added but also on the particular buffer used. The proposed equations allow an accurate prediction of this ionization for the studied buffers. Since the retention of acid/base compounds shows a strong dependence of their degree of ionization, the equations are used to predict the change in this ionization with addition of acetonitrile when the RP HPLC mobile phase is prepared. This prediction allows estimation of the retention of an acid/base compound in a particular acetonitrile-water buffered mobile phase.

Journal Article↗

Fast, comprehensive two-dimensional HPLC separation of tryptic peptides based on high-temperature HPLC.

Two-dimensional HPLC (2D-LC) has recently received considerable attention, and is being used as an alternative to 2D gel electrophoresis in proteomics research. The greatest impediment to the widespread use of 2D-LC is the long analysis time ranging up to days per analysis, making the technique impractical for many jobs. Here we focus on improving the speed of gradient separations since these are typically used as the second dimension in peptide separations by 2D-LC. Specifically we describe high-temperature, ultrafast HPLC conditions, along with the instrument modifications needed to reduce the analysis time of each complete second-dimension gradient separation to tens of seconds. Most importantly, this system is capable of generating a high peak capacity (1350) characteristic of comprehensive 2D-LC in a relatively shorter analysis time (20 min) with a sampling rate sufficient to minimize information loss with simpler instrumentation than currently used; this is equivalent to one unit of peak capacity per second.

Chromatography, High Pressure Liquid↗

Identification by HPLC-DAD and HPLC-MS analyses and quantification of constituents of fennel teas and decoctions.

Qualitative and quantitative differences among the constituents in various fennel (Foeniculum vulgare Mill., family Apiaceae) teas prepared by classical infusion, microwave decoction, and dissolution are reported. Different commercial starting materials, such as fruit (unbroken and crushed), four herbal teas, and two instant herbal teas were evaluated. Chlorogenic acid (1), quercetin-3-O-beta-D-glucuronide (2), p-anisaldehyde (3), and trans-anethole (4) were identified by HPLC-DAD and HPLC-MS as constituents of fennel teas. No coumarins, which are characteristic constituents of plants of Apiaceae family, were found. Trans-anethole (4), the main constituent of the essential oil, was present in all teas. In addition p-anisaldehyde (3), a degradation product of trans-anethole, was also identified in all teas with the exception of two samples. Chlorogenic acid (1) and quercetin-3-O-beta-D-glucuronide (2) were also present in all teas. In addition, minor unidentified flavonol constituents were found in two teas. Quality, activity, and safety of the content of the investigated preparations are also discussed.

Beverages↗

Determination of anthocyanins from camu-camu (Myrciaria dubia) by HPLC-PDA, HPLC-MS, and NMR.

Camu-camu [Myrciaria dubia (HBK) McVaugh] is a small fruit native to the Amazonian rain forest. Its anthocyanin profile has now been investigated for the first time. Fruits from two different regions of the São Paulo state, Brazil, were analyzed. The major anthocyanins were isolated by high-speed countercurrent chromatography. HPLC-PDA, HPLC-MS/MS, and 1H NMR were used to confirm the identity of the main anthocyanins of camu-camu. Cyanidin-3-glucoside was identified as the major pigment in the fruits from both regions, representing 89.5% in the fruits produced in Iguape and 88.0% in those from Mirandópolis, followed by the delphinidin-3-glucoside, ranging between 4.2 and 5.1%, respectively. Higher total anthocyanin contents were detected in the fruits from Iguape (54.0 +/- 25.9 mg/100 g) compared to those from Mirandópolis (30.3 +/- 6.8 mg/100 g), most likely because of the lower temperatures in the Iguape region.

Anthocyanins↗

High-performance liquid chromatographic (HPLC) and HPLC-mass spectrometric (MS) analysis of the degradation of the luteinizing hormone-releasing hormone (LH-RH) antagonist RS-26306 in aqueous solution.

The kinetics of the degradation of an LH-RH antagonist, RS-26306,1, in aqueous solution from pH 1 to pH 11 were studied by reverse-phase HPLC. The pH-rate profiles at 50, 60, and 80 degrees C were U-shaped with the rate law of kobs = kHaH + kw + kOHaOH. The predicted 25 degrees C shelf life at the pH of maximum stability, pH approximately 5, is greater than 10 years. The products from the degradation were analyzed by HPLC-MS using thermospray ionization. Below pH 3, the primary product, 2, forms from the acid-catalyzed deamidation of the C-terminal amide. Above pH 7, epimerization of the individual amino acids is the principal reaction. Between pH 4 and pH 6, intramolecular serine-catalyzed peptide hydrolysis becomes important, yielding a tripeptide, 3, and a heptapeptide, 4. At the pH of maximum stability all three pathways for degradation are observed.

Chemical Phenomena↗

Metabolism of 4-fluoroaniline and 4-fluorobiphenyl in the earthworm Eisenia veneta characterized by high-resolution NMR spectroscopy with directly coupled HPLC-NMR and HPLC-MS.

1. Little is known about metabolism of xenobiotics by earthworms, despite their importance in soil ecotoxicity testing. Normal earthworms and earthworms treated with antibiotics to ensure inhibition of gut microflora were exposed to two model xenobiotic compounds, 4-fluoroaniline and 4-fluorobiphenyl, to determine which metabolites were produced, and whether the pattern of metabolism was affected by the presence of microbial transformation ability. 2. (19)F-NMR spectroscopy detected the number and relative proportions of metabolites and directly coupled HPLC-(1)H-NMR spectroscopy and HPLC-MS then identified the metabolites. 3. Despite uptake, no metabolism of 4-fluorobiphenyl was observed at any stage, which appears to be a consequence of the lack of oxidative Phase I metabolic activity of the earthworms towards this substrate. In contrast, 4-fluoroaniline exhibited dose-dependent metabolism. At high doses (leading to mortality within 24 h) one predominant metabolite was observed, which was identified as the N-beta-glucoside conjugate. At lower dose levels, the predominant metabolite was the gamma-glutamyl conjugate, although the glucoside and another as yet unidentified metabolite were also detected. 4. The inhibition of gut microflora did not have any influence on metabolism. The study represents the first evidence for glucoside and glutamyl conjugation as a pathway for xenobiotic metabolism in earthworms.

Aniline Compounds↗

Characterization and quantification of metabolites of racemic ketoprofen excreted in urine following oral administration to man by 1H-NMR spectroscopy, directly coupled HPLC-MS and HPLC-NMR, and circular dichroism.

The identity of the human metabolites of ketoprofen (2-(3-benzoylphenyl)-propanoic acid) excreted via urine was investigated after a single oral dose of the racemic drug. Drug metabolites were concentrated and partially purified from urine using solid-phase extraction chromatography before separation and identification by directly coupled HPLC-MS and HPLC-NMR. The metabolites identified were the ester glucuronides of the parent drug and its phase I metabolites, 2-[3-(3-hydroxybenzoyl)phenyl]-propanoic acid, 2-[3-(4-hydroxybenzoyl)phenyl]-propanoic acid and 2-[3-(hydroxy(phenyl)methyl)phenyl]-propanoic acid, the latter formed by reduction of the ketone group of ketoprofen. In addition, two novel minor metabolites were identified as the ether glucuronides of 2-[3-(3-hydroxybenzoyl)phenyl]-propanoic acid and 2-[3-(4-hydroxybenzoyl)phenyl]-propanoic acid. These conjugates were all observed as diastereoisomeric pairs of unequal proportions. Purification of these metabolites by preparative chromatography allowed stereochemistry assignments. Metabolites were quantified by 1H-NMR spectroscopy after spectral simplification achieved by hydrolysis of the conjugates.

Administration, Oral↗

Analysis and stability of the constituents of artichoke and St. John's wort tinctures by HPLC-DAD and HPLC-MS.

In continuing our investigations on tinctures, which represent both herbal drug preparations and herbal medicinal products, 40% and 60% v/v tinctures of artichoke and St. John's wort were investigated. Artichoke is largely used in hepatic disorders, while St. John's wort is an anti-inflammatory, antidepressant, and healing agent. Both herbal drugs contain various constituents, although the compounds responsible for the main effects have not yet been completely identified. However, caffeoylquinic acids and flavones seem to be of crucial importance for the activity of artichoke, as well as flavonoids, naphthodianthrones, and phloroglucinol derivatives for St. John's wort, and they are used as marker constituents. Thus, quantification of all these constituents was performed using high-performance liquid chromatography-diode array detection (HPLC-DAD) and HPLC--mass spectrometry (MS) analyses with rutin as external standard. In addition the stability of the constituents of these tinctures from accelerated and long-term testing was also evaluated. From the results it was evidenced that constituent content depends on the solvent used for the extraction. The stability was also shown to be very different and seems to be related to the water content of the tinctures.

Chromatography, High Pressure Liquid↗

Lead speciation by HPLC-ICP-AES and HPLC-ICP-MS.

Speciation of inorganic lead (Pb2+) and several trialkyllead species (trimethyllead chloride [TML], triethyllead chloride [TEL], and triphenyllead chloride [TPhL]) is investigated using high-performance liquid chromatography (HPLC) with detection by both inductively coupled plasma emission spectroscopy (ICP-AES), and inductively coupled plasma mass spectrometry (ICP-MS). Reversed-phase, ion-pairing, and ion-exchange HPLC modes are studied. Optimal chromatographic conditions for ICP-AES detection include a reversed-phase separation utilizing a step gradient from 10 to 70% methanol. However, the gradient has been found to destabilize the plasma when using ICP-MS detection. An isocratic separation with a 30% methanol mobile phase has been found to be the best compromise between plasma stability and chromatographic resolution. Detection limits using ICP-MS detection are 3 orders of magnitude improved over ICP-AES detection.

Chromatography, High Pressure Liquid↗

Determination of bromethalin in commercial rodenticides found in consumer product samples by HPLC-UV-vis spectrophotometry and HPLC-negative-ion APCI-MS.

A small amount of green particulate material is encountered in a consumer complaint sample. The green particulates in the sample are identified as a bromethalin-containing rodenticide using high-performance liquid chromatographic (HPLC)-UV-vis spectrophotometric and HPLC-negative-ion atmospheric pressure chemical ionization (APCI)-mass spectrometric (MS) approaches, which are commonly used for the detection and confirmation of bromethalin in grain-based rodenticides. The selective and sensitive nature of the MS detector makes it possible to determine bromethalin without extensive sample cleanup and preconcentration. The estimated detection limit with the UV-vis detector is 500 pg of bromethalin injected into the column. The extensive fragmentation of the bromethalin molecule under APCI conditions provides sufficient structural information for positive identification.

Aniline Compounds↗

Separation and identification of the phthalic anhydride derivatives of Liqusticum Chuanxiong Hort by GC-MS, TLC, HPLC-DAD, and HPLC-MS.

A simple, sensitive, and rapid method using gas chromatography (GC)-mass spectrometry (MS) is developed for the simultaneous separation and identification of the active ingredients of Liqusticum Chuanxiong Hort (Chuanxiong). Ten phthalic anhydride derivatives (PADs) are identified in Chuanxiong as 3-butylphthalide, 3-butylidenephthalide, 3-butylidene-4-hydroxyphthalide, senkyunolide A, neocnidilide, Z-ligustilide, E-ligustilide, senkyunolide F, senkyunolide-H, and senkyunolide-I. The existence of ferulic acid and vanillin in Chuanxiong extract is also demonstrated. Further identification of these compounds is performed by thin-layer chromatography, high-performance liquid chromatography (HPLC), and HPLC-MS analysis. This is the first report of the separation and determination of the PADs in Chuanxiong by GC-MS.

Chromatography, High Pressure Liquid↗

HPLC and HPLC-MS analysis of urinary N(epsilon)-monomethyl-lysine.

Administration of (14)C-labelled L-deprenyl to rats results in the urinary elimination of a 14C-labelled compound. The 9-fluorenylmethoxycarbonyl chloride-reacted urine sample is fractionated by high-performance liquid chromatography (HPLC) on an octadecyl silica stationary phase. N(epsilon)-Monomethyl-lysine is identified in the fraction containing the majority of the radioactivity. Structural elucidation is carried out using HPLC-mass spectrometry in atmospheric pressure chemical ionization mode. Identification of the 14C-labelled fragment in Ne-monomethyl-lysine is an experimental proof that an N-methylated amino acid is generated by transmethylation from a well-known drug. This type of transmethylation may have basic importance in the positive side effects of certain drugs.

Animals↗

Development and validation of a HPLC method for 4,7-phenanthroline-5,6-dione I and identification of its major impurity by HPLC-MS-APCI.

In this study, the development and validation of an analytical method for the assay of 4,7-phenanthroline-5,6-dione I (dione I) using high-performance liquid chromatography (HPLC) and the determination of its synthetic impurities by employing the method in HPLC-mass spectrometry with atmospheric-pressure chemical ionization and photodiode-array UV detection is reported. The results show that dione I is eluted as a spectrally pure peak resolved from its impurities. 5-Bromo,4-7-phenanthroline is identified as the main impurity. This is supported by elemental analysis of the dione I, which demonstrated the presence of bromine. Validation parameters such as specificity and selectivity, linearity, accuracy, precision, limit of detection (LOD), limit of quantitation (LOQ), ruggedness, stability, and system suitability, which are evaluated for this method. The LOD and LOQ are 2.0 microg/mL and 50 microg/mL with a 0.50% relative standard deviation (%RSD), respectively. The calibration curves showed good linearity over the concentration range of 0.05-1.50 mg/mL. The correlation coefficient is > 0.9991 in each case. The %RSD values for intra- and interday precision studies are < 0.40%.

Chromatography, High Pressure Liquid↗

HPLC-DAD and HPLC-MS findings in fatality involving (Z)-cis-clopenthixol (zuclopenthixol).

A fatality that was due to massive ingestion of the thioxanthene neuroleptic (Z)-cis-clopenthixol (zuclopenthixol, Z-CPT) is described. The total toxicological screening and the quantitation of both the ingested drugs and its inactive isomer (E)-trans-clopenthixol (E-CPT, produced by in vivo isomerization) in postmortem fluids and viscerae were produced by high-performance liquid chromatography (HPLC)-diode array detection. Drug confirmation was carried out by HPLC-mass spectrometry with an ionspray interface. Although death occurred 40 h after the drug intake, postmortem blood concentrations were 391 and 275 mg/mL for Z-CPT and E-CPT, respectively (50 to 100 times the usual therapeutic values). The cause of death was suicide, and the manner was acute neuroleptic overdosage.

Adolescent↗

A rapid cost-effective high-performance liquid chromatographic (HPLC) assay of serum lamotrigine after liquid-liquid extraction and using HPLC conditions routinely used for analysis of barbiturates.

Lamotrigine (lamictal) is a new anticonvulsant drug approved by the FDA for clinical use. Therapeutic monitoring of lamotrigine is useful for patient management and avoidance of toxicity. The suggested therapeutic range is 1 to 4 micrograms/ml. The authors describe a simple high-performance liquid chromatographic (HPLC) method for analysis of lamotrigine from serum. Serum (0.5 ml) was alkalinized with borate buffer (pH 9.8). Lamotrigine and the internal standard thiopental were extracted with 10 ml of chloroform. After evaporation of the extract, the residue was reconstituted in the mobile phase (prepared by mixing 750 ml of potassium dihydrogen phosphate, 550 ml of deionized water, 430 ml of methanol, and 100 microliters of triethylamine as an ion pairing reagent) and injected into an LC-18 column (15 cm x 4.6 mm). The authors use this HPLC system routinely in their laboratory for the analysis of barbiturates. They demonstrated that the same system can be used for the analysis of lamotrigine. The within-run and between-run precisions of the lamotrigine assay were 1.63% (mean = 3.05, SD = 0.05 microgram/ml, n = 6) and 3.7% (mean = 2.97 micrograms/ml, SD = 0.11, n = 8). The assay was linear for serum lamotrigine concentrations of 0.5 microgram/ml to 20 micrograms/ml with a detection limit of 0.5 microgram/ml. The authors observed excellent correlation between serum lamotrigine concentrations measured by their assay and a reference laboratory in six patients receiving lamotrigine. Their assay is free from interferences from common tricyclic antidepressants, benzodiazepines, other common anticonvulsants, salicylate, and acetaminophen.

Anticonvulsants↗