PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Isothermal amplification”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Development and evaluation of a loop-mediated isothermal amplification method for rapid diagnosis of Bordetella pertussis infection.

We developed a loop-mediated isothermal amplification (LAMP) method to detect Bordetella pertussis infection. This LAMP assay detected B. pertussis with high sensitivity, but not other Bordetella species. Among nasopharyngeal swab samples from subjects with suspected pertussis, LAMP results showed a high level of agreement with results of conventional PCR. This method is a rapid, sensitive, and specific method for diagnosis of B. pertussis infection even in clinical laboratories with no specific equipment.

Base Sequence↗

Real-time reverse transcription loop-mediated isothermal amplification for rapid detection of West Nile virus.

A one-step, single tube, real-time accelerated reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for detecting the envelope gene of West Nile (WN) virus. The RT-LAMP assay is a novel method of gene amplification that amplifies nucleic acid with high specificity, efficiency, and rapidity under isothermal conditions with a set of six specially designed primers that recognize eight distinct sequences of the target. The whole procedure is very simple and rapid, and amplification can be obtained in less than 1 h by incubating all of the reagents in a single tube with reverse transcriptase and Bst DNA polymerase at 63 degrees C. Detection of gene amplification could be accomplished by agarose gel electrophoresis, as well as by real-time monitoring in an inexpensive turbidimeter. When the sensitivity of the RT-LAMP assay was compared to that of conventional RT-PCR, it was found that the RT-LAMP assay demonstrated 10-fold higher sensitivity compared to RT-PCR, with a detection limit of 0.1 PFU of virus. By using real-time monitoring, 10(4) PFU of virus could be detected in as little as 17 min. The specificity of the RT-LAMP assay was validated by the absence of any cross-reaction with other, closely related, members of the Flavivirus group, followed by restriction digestion and nucleotide sequencing of the amplified product. These results indicate that the RT-LAMP assay is extremely rapid, cost-effective, highly sensitive, and specific and has potential usefulness for rapid, comprehensive WN virus surveillance along with virus isolation and/or serology.

Nucleic Acid Amplification Techniques↗

Development of immunocapture reverse transcription loop-mediated isothermal amplification for the detection of tomato spotted wilt virus from chrysanthemum.

An immunocapture reverse transcription loop-mediated isothermal amplification (IC/RT-LAMP) was developed for the detection of tomato spotted wilt virus (TSWV) from chrysanthemum. This method enabled sensitive, reproducible and specific detection of TSWV from chrysanthemum plants. In the RT-LAMP method, TSWV genomic RNA could be amplified under isothermal (65 degrees C) conditions within 1 h. The resulting amplicons were detected by the measurement or observation of the turbidity of the reaction mixture without gel electrophoresis. IC/RT-LAMP was 100 times more sensitive than IC/RT-PCR.

Base Sequence↗

Rapid detection and differentiation of dengue virus serotypes by a real-time reverse transcription-loop-mediated isothermal amplification assay.

The development and validation of a one-step, real-time, and quantitative dengue virus serotype-specific reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay targeting the 3' noncoding region for the rapid detection and differentiation of dengue virus serotypes are reported. The RT-LAMP assay is very simple and rapid, wherein the amplification can be obtained in 30 min under isothermal conditions at 63 degrees C by employing a set of four serotype-specific primer mixtures through real-time monitoring in an inexpensive turbidimeter. The evaluation of the RT-LAMP assay for use for clinical diagnosis with a limited number of patient serum samples, confirmed to be infected with each serotype, revealed a higher sensitivity by picking up 100% samples as positive, whereas 87% and 81% of the samples were positive by reverse transcription-PCR and virus isolation, respectively. The sensitivity and specificity of the RT-LAMP assay for the detection of viral RNA in patient serum samples with reference to virus isolation were 100% and 93%, respectively. The optimal assay conditions with zero background and no cross-reaction with other closely related members of the Flavivirus family (Japanese encephalitis, West Nile, and St. Louis encephalitis viruses) as well as within the four serotypes of dengue virus were established. None of the serum samples from healthy individuals screened in this study showed any cross-reaction with the four dengue virus serotype-specific RT-LAMP assay primers. These findings demonstrate that RT-LAMP assay has the potential clinical application for detection and differentiation of dengue virus serotypes, especially in developing countries.

Dengue↗

Use of reverse transcription loop-mediated isothermal amplification for the detection of Plum pox virus.

A one step, accelerated reverse transcription loop-mediated isothermal amplification (RT-LAMP) procedure was developed for the detection of Plum pox virus (PPV). The six primers required for accelerated RT-LAMP were designed using a conserved region in the C-terminus of the coat protein coding region of PPV. RT-LAMP was used to detect isolates of five strains of PPV including the strains D, M, EA, C, and W. The virus was detected reliably in both infected herbaceous and woody hosts. RT-LAMP was compared to real-time RT-PCR with SYBR Green I and melting curve analysis, using serial dilutions of total RNA extracts. Similar sensitivities were observed, except that real-time RT-PCR was more consistent at lower template concentrations. The purity of the FIP and BIP primers affected the efficiency of the reaction, and incubation time and template concentration affected the ladder-like pattern observed after agarose gel electrophoresis. Although PPV could be detected after 30min of incubation at 63 degrees C, a longer incubation time was required for lower concentrations of the target. RT-LAMP is a very sensitive, low cost diagnostic tool that should be of value in more accurate determination of the distribution of PPV. This should assist in preventing further spread of this devastating virus.

Base Sequence↗

Loop-mediated isothermal amplification method for rapid detection of the periodontopathic bacteria Porphyromonas gingivalis, Tannerella forsythia, and Treponema denticola.

Loop-mediated isothermal amplification (LAMP), a novel nucleic acid amplification method, was developed for the rapid detection of the major periodontal pathogens Porphyromonas gingivalis, Tannerella forsythia, and Treponema denticola. The LAMP method amplifies DNA with high specificity, efficiency, and rapidity under isothermal conditions using a set of four specially designed primers and a DNA polymerase with strand displacement activity. In this study, we initially designed the primers for LAMP assays to detect these bacteria and evaluated the specificity and sensitivity of these assays. The specificities of the primers for these bacteria were examined using various oral bacteria and various reaction times. The lower detection limits of the 60-min LAMP reaction without loop primers were 1 microg/tube for P. gingivalis, 10 fg/tube for T. forsythia, and 1 ng/tube for T. denticola. Addition of the loop primers for each bacterium improved the detection specificities and sensitivities by several magnitudes. Furthermore, LAMP assays were applied to the rapid detection of these periodontal pathogens in clinical specimens, and the results were compared with those of conventional PCR detection. The results of the LAMP assays corresponded to those of conventional PCR assays. These results indicate that the LAMP assay is an extremely rapid, highly sensitive, specific method. This method is very useful for the rapid detection of periodontopathic bacteria and the diagnosis of periodontal disease.

Bacteroidaceae↗

Detection of bacteria carrying the stx2 gene by in situ loop-mediated isothermal amplification.

A new in situ DNA amplification technique for microscopic detection of bacteria carrying a specific gene is described. Loop-mediated isothermal amplification (LAMP) was used to detect stxA(2) in Escherichia coli O157:H7 cells. The mild permeabilization conditions and low isothermal temperature used in the in situ LAMP method caused less cell damage than in situ PCR. It allowed use of fluorescent antibody labeling in the bacterial mixture after the DNA amplification for identification of E. coli O157:H7 cells with an stxA(2) gene. Higher-contrast images were obtained with this method than with in situ PCR.

Escherichia coli O157↗

Development and evaluation of reverse transcription-loop-mediated isothermal amplification assay for rapid and real-time detection of Japanese encephalitis virus.

The standardization and validation of a one-step, single-tube accelerated quantitative reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay is reported for rapid and real-time detection of Japanese encephalitis virus (JEV). The RT-LAMP assay reported in this study is very simple and rapid; the amplification can be obtained in 30 min under isothermal conditions at 63 degrees C by employing a set of six primers targeting the E gene of JEV. The RT-LAMP assay demonstrated exceptionally higher sensitivity compared to that of RT-PCR, with a detection limit of 0.1 PFU. The specificities of the selected primer sets were established by cross-reactivity studies with other closely related members of the JEV serocomplex as well as by evaluation of healthy human volunteers. The comparative evaluation of the RT-LAMP assay for clinical diagnosis with a limited number of patient cerebrospinal fluid samples revealed 85% concordance with conventional RT-PCR, with a sensitivity and a specificity of 100% and 86%, respectively. The concentration of virus in most of the clinical samples was 10(2) to 10(5) PFU/ml, as determined from the standard curve based on the time of positivity in the samples. In addition, the monitoring of gene amplification can also be visualized with the naked eye by using SYBR green I fluorescent dye. Thus, due to easy operation without a requirement of sophisticated equipment and skilled personnel, the RT-LAMP assay reported here is a valuable tool for the rapid and real-time detection of JEV not only by well-equipped laboratories but also by peripheral diagnostic laboratories with limited financial resources in developing countries.

Antibodies, Viral↗

Development and evaluation of a novel loop-mediated isothermal amplification method for rapid detection of severe acute respiratory syndrome coronavirus.

The development and evaluation of a one-step single-tube accelerated real-time quantitative reverse transcription (RT) loop-mediated isothermal amplification (LAMP) assay is reported for rapid detection of the severe acute respiratory syndrome coronavirus (SARS-CoV) replicase gene. A total of 49 samples (15 throat washes, 13 throat swabs, and 21 combined throat and nasal swabs) collected from patients admitted to the Hanoi-French and Ninhbinh hospitals in Vietnam during the SARS epidemic were evaluated and compared to conventional RT-PCR. The RT-LAMP assay demonstrated 100-fold-greater sensitivity, with a detection limit of 0.01 PFU. The sensitivity and specificity of RT-LAMP assay for detecting viral RNA in clinical specimens with regard to RT-PCR were 100 and 87%, respectively. The specificity of the RT-LAMP assay was further validated by restriction analysis as well as nucleotide sequencing of the amplified product. The concentration of virus in most of the clinical samples was 0.1 PFU (0.1 to 10(2) PFU), as determined from the standard curve of SARS RT-LAMP and based on the time of positivity. The assay procedure is quite simple, wherein the amplification is carried out in a single tube under isothermal conditions at 63 degrees C, and the result can be obtained in less than 1 h (as early as 11 min). Thus, the RT-LAMP assay reported here has the advantages of rapid amplification, simple operation, and easy detection and will be useful for rapid and reliable clinical diagnosis of SARS-CoV in developing countries.

Base Sequence↗

Development of a new method for diagnosis of rubella virus infection by reverse transcription-loop-mediated isothermal amplification.

We developed a useful method for the detection of rubella virus genome RNA by reverse transcription loop-mediated isothermal amplification (RT-LAMP) and compared the sensitivity of RT-LAMP with that of other virological tests: reverse transcription-PCR (RT-PCR) and virus isolation. The rubella virus genome was amplified by RT-LAMP from clinical isolates obtained between 1987 and 2004 with similar sensitivities to the Takahashi vaccine strain. The detection limit of RT-LAMP was compared with that of RT-PCR using the Takahashi vaccine strain. We detected rubella virus genome material corresponding to 30 PFU/ml in a culture fluid sample by RT-LAMP within 60 min after the extraction of RNA with equal sensitivity to RT-nested PCR. The positive result rates of RT-LAMP, RT-PCR, and virus isolation were also compared using throat swabs obtained from patients who were clinically diagnosed with acute rubella virus infection in 2004 in Tochigi, Japan. Among nine patients with clinical rubella, the positive result rates were three/nine (33.3%) for virus isolation, six/nine (66.7%) for RT-PCR, and seven/nine (77.8%) for RT-LAMP. Consequently, RT-LAMP for rubella virus would be expected to be a reliable rapid diagnostic tool in the clinical setting.

Genome, Viral↗

Loop-mediated isothermal amplification for rapid detection of Newcastle disease virus.

We have evaluated a diagnostic system based on the loop-mediated isothermal amplification (LAMP) assay for the rapid, simple, and sensitive detection of Newcastle disease virus (NDV) directly from culture isolates as well as clinical samples. By using one set of specific primers targeting the fusion protein gene, the LAMP assay rapidly amplified the target gene within 2 h, requiring only a regular laboratory water bath or heat block for reaction. The results obtained from testing the genomes of 38 NDV strains, other different viruses, and clinical samples of experimentally infected chickens showed that LAMP was as sensitive and specific as nested PCR. All LAMP-positive samples were positive by nested PCR. The LAMP assay is faster than nested PCR, cost-effective, and easy to perform. Our results clearly demonstrate that the LAMP-based assay is a useful tool for the rapid and sensitive diagnosis of NDV infection.

Animals↗

Use of loop-mediated isothermal amplification of the IS900 sequence for rapid detection of cultured Mycobacterium avium subsp. paratuberculosis.

We evaluated the usefulness of loop-mediated isothermal amplification (LAMP) in detecting specific gene sequences of Mycobacterium avium subsp. paratuberculosis (MAP). A total of 102 primer sets for LAMP was designed to amplify the IS900, HspX, and F57 gene sequences of MAP. Using each of two primer sets (P-1 and P-2) derived from the IS900 fragment, it was possible to detect MAP in a manner similar to that used with nested PCR. The sensitivity of LAMP with P-1 was 0.5 pg/tube, which was more sensitive than nested PCR. When P-2 was used, 5 pg/tube could be detected, which was the same level of sensitivity as that for nested PCR. LAMP with P-1 was specific. Although only 2 Mycobacterium scrofulaceum strains out of 43 non-MAP mycobacterial strains were amplified, the amplification reaction for these strains was less efficient than for MAP strains, and their products could be distinguished from MAP products by restriction digestion. LAMP with P-2 resulted in very specific amplification only from MAP, the same result obtained with nested PCR. Our LAMP method was highly specific, and the white turbidity of magnesium pyrophosphate, a by-product of the LAMP reaction, allowed simple visual detection. Our method is rapid, taking only 2 h, compared with 4 h for nested PCR. In addition, the LAMP method is performed under isothermal conditions and no special apparatus is needed, which makes it more economical and practical than nested PCR or real-time PCR. These results indicate that LAMP can provide a rapid yet simple test for the detection of MAP.

DNA Transposable Elements↗

Reverse transcription loop-mediated isothermal amplification (RT-LAMP) for rapid detection of viral hemorrhagic septicaemia virus (VHS).

A one step reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for detection of viral hemorrhagic septicaemia virus (VHS). A set of six primers were designed, based on the G-protein sequence of the VHS virus serotypes (He, F1, 23.75, Klapmolle and Rindsholm). The assay was optimised to amplify VHS RNA by incubation at 63 degrees C for only 1h, and required only a simple water bath or heating block to provide a constant temperature of 63 degrees C. RT-LAMP amplification products were detected by visual inspection using SYBR Green I stain and had a ladder-like appearance when electrophoresed on an agarose gel. The detection limit of the RT-LAMP assay was found to be similar to the commonly used RT-PCR method: both methods detected VHS RNA at a dilution of 10(6). The assay was evaluated using clinical samples and the results indicated the suitability and simplicity of the test as a rapid, field diagnostic tool for VHS virus.

Animals↗

Rapid detection of norovirus from fecal specimens by real-time reverse transcription-loop-mediated isothermal amplification assay.

In this study, we developed a one-step, single-tube genogroup-specific reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay for the detection of norovirus (NoV) genomes targeting from the C terminus of the RNA-dependent RNA polymerase gene to the capsid N-terminal/shell domain region. This is the first report on the development of an RT-LAMP assay for the detection of NoV genomes. Because of the diversity of NoV genotypes, we used 9 and 13 specially designed primers containing mixed bases for genogroup I (GI) and II (GII), respectively. The RT-LAMP assay had the advantages of rapidity, simplicity, specificity, and selectively and could obtain results within 90 min, generally even within 60 min, under isothermal conditions at 62 degrees C. The detection limits for NoV genomes were between 10(2) and 10(3) copies/tube for GI and GII with differentiation by genotype, and no cross-reactions among NoV GI and GII and other gastroenteritis viruses, such as sapovirus, human astrovirus, adenovirus type 40 and 41, and group A and C rotavirus, were found. In the evaluation tests with fecal specimens obtained from gastroenteritis outbreaks, the sensitivity and specificity of the RT-LAMP assay with regard to RT-PCR were 100 and 94% for GI and 100 and 100% for GII, respectively. These findings establish that the RT-LAMP assay is potentially useful for the rapid detection of NoV genomes from fecal specimens in outbreaks of food-borne and person-to-person-transmitted gastroenteritis.

Caliciviridae Infections↗

A loop mediated isothermal amplification (LAMP) method for detection of infectious hematopoietic necrosis virus (IHNV) in rainbow trout (Oncorhynchus mykiss).

A reverse transcription loop-mediated isothermal amplification (RT-LAMP) protocol was developed for detection of infectious hematopoietic necrosis virus (IHNV) RNA in rainbow trout (Oncorhynchus mykiss). A set of four primers, two outer and two inner primers for the RT-LAMP and the LAMP assay, were designed based on the sequence of G-protein of IHNV. Time and temperature conditions were optimized for 60 min at 63 degrees C for both RT-LAMP and LAMP protocols. The detection limit was found to be similar for both RT-LAMP and LAMP. When the sensitivity of RT-LAMP and LAMP were compared with conventional nested PCR, a10-fold higher sensitivity was seen for the LAMP protocols.

Animals↗

Rapid and real-time detection of Chikungunya virus by reverse transcription loop-mediated isothermal amplification assay.

The standardization and validation of a one-step, single-tube, accelerated, quantitative reverse transcription (RT) loop-mediated isothermal amplification (RT-LAMP) assay targeting the E1 gene for the rapid and real-time detection of Chikungunya virus (CHIKV) are reported. A linear relationship between the amount of template and time of positivity value over a range of 2 x 10(8) to 2 x 10(2) copies was obtained. The feasibility of CHIKV RT-LAMP for clinical diagnosis was validated with patient serum samples from an ongoing epidemic in Southern India. Optimal assay conditions with zero background were established for the detection of low levels of CHIKV in acute-phase patient serum samples. The comparative evaluation of the RT-LAMP assay with acute-phase patient serum samples demonstrated exceptionally higher sensitivity by correctly identifying 21 additional positive borderline cases that were missed by conventional RT-PCR (P < 0.0001) with a detection limit of 20 copies. The quantification of virus load in patient serum samples was also determined from the standard curve based on their time of positivity and was found to be in the range of 2 x 10(8) to 2 x 10(1) copies. In addition, the field applicability of the RT-LAMP assay was also demonstrated by standardizing SYBR Green I-based RT-LAMP wherein the amplification was carried out in a water bath at 63 degrees C for 60 min, which was followed by monitoring gene amplification with the naked eye through color changes. These findings demonstrated that the RT-LAMP assay is a valuable tool for rapid, real-time detection as well as quantification of CHIKV in acute-phase serum samples without requiring any sophisticated equipment and has potential usefulness for clinical diagnosis and surveillance of CHIKV in developing countries.

Acute Disease↗

Diagnosis of human respiratory syncytial virus infection using reverse transcription loop-mediated isothermal amplification.

Human respiratory syncytial virus (RSV) is a major causative agent of lower respiratory tract infections in children and the elderly. A reverse transcription-loop-mediated isothermal amplification (RT-LAMP) was developed assay to amplify the genome of RSV subgroups A and B, in order to improve current diagnostic methods for RSV infection. The primer sets for RT-LAMP were designed using highly conserved nucleotide sequences in the matrix protein region of subgroups A and B, and were specific for each subgroup. The RT-LAMP efficiency was compared to virus isolation and a commercially available enzyme immunoassay (EIA) for RSV detection (BD Directigen EZ RSV test), using nasopharyngeal aspirates from 59 children with respiratory tract infections. The RT-LAMP was specific for RSV and could not detect other respiratory pathogens. 61% (36/59) of children were positive by RT-LAMP, 34% (20/59) by viral isolation, and 56% (26/46) by EZ RSV. Of 16 specimens that were negative by both antigen detection and virus isolation, 12.5% (2/16) were RT-LAMP positive. These results suggest that the RT-LAMP is more sensitive than other methods used to detect RSV. The RT-LAMP assay developed in this study may be useful for diagnostic and epidemiological studies of RSV infection.

Base Sequence↗