PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Labor Stage, First”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Effect of pethidine administered during the first stage of labor on the acid-base status at birth.

OBJECTIVE: To evaluate the association between the use of pethidine during the first stage of labor and the presence, type and timing of acidosis in the newborn at birth. STUDY DESIGN: Secondary data analysis of a randomized controlled trial, which included term singleton pregnancies diagnosed with dystocia and requiring active management of labor. Women were randomized to receive either 100 mg of pethidine or placebo. Statistical analyses were performed using chi(2) or Fisher's exact tests for proportions and multiple linear regression for continuous outcomes. RESULTS: Three hundred and eighty-three pregnant women with a valid arterial blood cord sample were included in the final analysis. Lower pH and bicarbonate levels, as well as higher pCO(2) levels were found in the pethidide group. A higher incidence of acidosis was found in the pethidine group (pH<7.12 OR: 8.59 95% C.I. 3.29, 22.46). The highest frequency of acidosis was encountered when pethidine-delivery interval was 5 h. CONCLUSION: Pethidine use during the first stage of labor was associated with an increased risk of acidosis at birth.

Acid-Base Equilibrium↗

Normal values of fetal ductus venosus blood flow waveforms during the first stage of labor.

OBJECTIVE: To present normal values of fetal ductus venosus blood flow waveforms during the first stage of labor during and between contractions. MATERIALS AND METHODS: Seventy-eight women between the 37th and 41st weeks of gestation were included in the study. At distinct stages of cervical dilation, blood flow velocity waveforms of the fetal ductus venosus during and between contractions were visualized in fetuses with a normal non-stress test. The pulsatility index for veins, peak velocity index for veins and fetal heart rate were calculated off-line. The means +/- standard deviations (SD) during and between contractions were compared using the Wilcoxon test. RESULTS: Ductus venosus blood flow velocity waveforms were visualized during 331 contractions and 375 episodes of uterine quiescence in 74 of 78 fetuses (95%) during normal labor. The mean +/- standard deviation values of pulsatility and peak velocity indices for veins during contractions were 1.66 +/- 0.85 (median: 1.56, range: 0.29-4.69) and 1.46 +/- 0.65 (median: 1.34, range: 0.26-3.13), respectively. Between contractions the values were 0.48 +/- 0.19 (median: 0.46, range: 0.14-1.00) for the pulsatility index and 0.44 +/- 0.18 (median: 0.42, range: 0.14-1.00) for the peak velocity index for veins. These differences during and between contractions were highly significant (P-value < 0.0001), whereas the fetal heart rate showed no significant differences. CONCLUSION: There are significant differences in fetal ductus venosus blood flow waveforms during and between labor contractions. Further studies should evaluate whether these normal values of the fetal ductus venosus are beneficial for risk evaluation in fetuses with an abnormal non-stress test and/or intrauterine growth restriction.

Adult↗

A comparative study of the safety of 0.25% levobupivacaine and 0.25% racemic bupivacaine for paracervical block in the first stage of labor.

BACKGROUND: The objective of the study was to evaluate and compare the safety of levobupivacaine and racemic bupivacaine for paracervical block (PCB) in the first stage of labor after uncomplicated pregnancy. METHODS: Forty women in an open pilot study and 397 women in a double-blind randomized study received PCB for pain relief in the first stage of labor, either with 25 mg of levobupivacaine or with 25 mg of racemic bupivacaine. The incidence of cardiotocographic pathology was compared between the groups using Fisher's exact test. The 95% confidence intervals for the between-group difference were calculated by Newcombe's method. RESULTS: In the randomized double-blind study, the incidence of any pathological result in cardiotocography (CTG) was 10.4% in the levobupivacaine group and 12.8% in the racemic bupivacaine group. The incidence of fetal bradycardia in the groups was 2.6 and 3.8%, respectively. All the cardiotocographic changes were transient, and no operative intervention was indicated because of CTG. No difference in the analgesic effect between the drugs was found. Most of the parturients in the levobupivacaine group (97%) and in the racemic bupivacaine group (96%) had spontaneous vaginal delivery. Neonatal outcome was good in both groups. CONCLUSIONS: No difference in cardiotocographic pathology was found between PCB with levobupivacaine compared with PCB with racemic bupivacaine. The incidence of bradycardia was low. PCB was found to be a safe pain-relief method for low-risk parturients.

Adult↗

Uterine activity and ductus venosus flow velocity patterns during the first stage of labor.

OBJECTIVE: To analyze the effects of uterine contractions on ductus venosus (DV) pulsatility during the first stage of labor. METHODS: Twenty healthy women were examined. Measurements were taken at three stages of cervical dilatation (<4 cm, 4-7 cm and >or=8 cm) during and between contractions. Peak velocity during ventricular systole (S) and atrial contraction (A), pulsatility index for veins (DV PIV), ductus venosus index (DVI) and the S/A ratio were measured. RESULTS: The DV was observed successfully in 16 cases. The mean S velocity did not change significantly (64 cm/s during and 65 cm/s between contractions). The mean A velocity decreased significantly from 35 cm/s measured between contractions to 29 cm/s during contractions (P<0.0001). The mean DV PIV and DVI were significantly higher during contractions (0.72 and 0.55) than between contractions (0.57 and 0.45) (P<0.0001). There were no significant differences in means between stages of cervical dilatation. CONCLUSION: Significant differences during and between uterine contractions can be observed in DV pulsatility during normal labor.

Adult↗

[Velocimetry of the ductus venosus in the first stage of labor].

OBJECTIVE: To assess feasibility and physiological variation of fetal ductus venosus Doppler velocimetry during the first stage of labor between uterine contractions. STUDY DESIGN: A prospective cross-sectional study including 23 healthy women with low-risk pregnancies. Maximum velocities during ventricular systole (S) and atrial contraction (A) were recorded in the ductus venosus between contractions. Pulsatility index for veins (DV PIV) and the ductus venosus index (DVI) were also calculated. SETTING: Department of Obstetrics and Gynecology, Jessenius Faculty of Medicine, Comenius University, Martin. RESULTS: Acceptable ductus venosus waveforms were acquired in 19 fetuses (83%). The mean +/- SD values of the ductus venosus index and the pulsatility index were 0.46 +/- 0.07 (95% CI: 0.42-0.49) and 0.57 +/- 0.12 (95% CI: 0.51-0.63), respectively. The mean +/- SD values of maximum velocities during ventricular systole (S) and atrial contraction (A) were 65 +/- 8 cm/s and 35 +/- 5 cm/s, respectively. CONCLUSION: Ductus venosus blood flow velocities can be assessed during labor. This calls for an extension of the detection possibilities of intrauterine fetal status and gives an idea to establish reference ranges for these circulation parameters during labor in the future.

Blood Flow Velocity↗

A reappraisal of the duration of labor.

The mean, median, and modal durations of labor have been established following a prospective study of 602 consecutive labors. The mean duration of labor for primiparae was 14.92 hours, while the median and modal durations were 13.20 and 9.66 hours, respectively. The corresponding figures for multiparae were 10.02, 9.28, and 7.80 hours, respectively. There was a statistically significant difference in the mean duration of labor in the 2 groups of patients (P less than 0.001). A significant positive correlation has been observed between the duration of the first stage of labor and the second stage of labor (P less than 0.001), and this might be of clinical importance. It has been suggested that the median and modal durations of labor may be more representative and informative than the mean or average.

Adult↗

Warm tub bath during labor. Effects on plasma catecholamine and beta-endorphin-like immunoreactivity concentrations in the infants at birth.

In this study 13 women bathed in a warm tub bath during the first stage labor after a strictly normal pregnancy. The control group consisted of 9 women who did not want warm tub bath. Apgar scores at 1 and 5 minutes were recorded and plasma adrenalin, noradrenalin were measured in umbilical arterial blood at birth, together with pH, pCO2 and base excess and beta-endorphin-like immunoreactivity in umbilical venous blood. No differences were found between the groups. No beneficial effect was found on infant condition of a warm tub bath during labor.

Baths↗

Pain in the first stage of labor: relationship with the patient's position.

This study was designed to evaluate the relationship between the parturient's position and her abdominal and lumbar (continuous and contraction) pain during the first stage of labor. A homogeneous group of 100 parturients was randomly assigned to alternately assume the horizontal or the vertical position for 15-min periods. Their pain was measured at 2-3, 4-5, 6-7, and 8-9 centimeters dilatation. To avoid "carry over" effect, these positions were preceded by a self-elected posture. Thus, the patient adopted (a) a self-elected position, (b) recumbent (or erect), (c) a self-elected position, (d) erect (or recumbent), and so on. Pain intensity was measured by the Argentine Pain Questionnaire's Present Pain Intensity and the Huskisson's visual analogue scale. Only the patients with at least one pain evaluation in both positions using both instruments were included in the study. The setting for the study was the obstetric department of a general hospital for people connected with public education (professors, teachers, or members of school administrative staffs). The analysis revealed that a majority of patients felt less abdominal and lumbar pain, either continuous or due to contractions, during recumbency. The effect was more remarkable when dilation exceeded 5 centimeters and less intense during the first half of the first stage of labor.

Adolescent↗

Analgesic and hemodynamic effects of intrathecal clonidine as the sole analgesic agent during first stage of labor: a dose-response study.

BACKGROUND: Intrathecal clonidine produces dose-dependent postoperative analgesia and enhances labor analgesia from intrathecal sufentanil. The authors evaluated the dose-response potency of intrathecally administered clonidine by itself during first stage of labor with respect to analgesia and maternal and fetal side effects. METHODS: Thirty-six parturients requesting labor analgesia were included in this prospective, randomized, double-blind study. Parturients with < 6 cm cervical dilatation received either 50, 100, or 200 microg intrathecal clonidine. The authors recorded visual analog pain score (VAPS), maternal blood pressure and heart rate, ephedrine requirements, and sedation at regular intervals and fetal heart rate tracings continuously. Duration of analgesia was defined as time from intrathecal clonidine administration until request for additional analgesia. RESULTS: Clonidine produced a reduction in VAPS with all three doses. The duration of analgesia was significantly longer in patients receiving 200 microg (median, 143; range, 75-210 min) and 100 microg (median, 118; range, 60-180 min) than 50 microg (median, 45; range, 25-150 min), and VAPS was lower in the 200-microg than in the 50-microg group. In the 200-microg group, hypotension required significantly more often treatment with ephedrine than in the other groups. No adverse events or fetal heart rate abnormalities occurred. CONCLUSIONS: Fifty to 200 microg intrathecal clonidine produces dose-dependent analgesia during first stage of labor. Although duration and quality of analgesia were more pronounced with 100 and 200 microg than with 50 microg, the high incidence of hypotension requires caution with the use of 200 microg for labor analgesia.

Adult↗

Meperidine for dystocia during the first stage of labor: A randomized controlled trial.

OBJECTIVE: This study was undertaken to evaluate whether the administration of meperidine decreases the length of labor in patients with a diagnosis of dystocia during the first stage of labor. STUDY DESIGN: Women with term singleton pregnancies who received a diagnosis of dystocia and required an active management of labor were randomly assigned to receive either 100 mg of meperidine or placebo. The primary outcome measure was length of labor. RESULTS: Four hundred seven pregnant women were included. There were no significant statistical differences between meperidine and placebo groups in length of labor and operative delivery rates such as forceps and cesarean section by intention-to-treat analysis. Low Apgar scores, umbilical artery acidosis, and admission to neonatal care units were increased in the meperidine group. CONCLUSION: Because of the absence of any benefits in patients with dystocia in labor and the presence of harmful effects on neonatal outcomes, meperidine should not be used during labor for this specific indication.

Analgesics, Opioid↗

Are there ethnic differences in the length of labor?

OBJECTIVE: The purpose of this study was to examine the lengths of the first and second stages of labor among different racial/ethnic groups to determine whether different norms should be established. STUDY DESIGN: This was a retrospective cohort study of all laboring, term, singleton, vertex deliveries in a single academic institution. Median lengths of first and second stages of labor were compared among 4 racial/ethnic groups: black, Asian, white, and Latina. Kruskal-Wallis, Wilcoxon rank sum tests, and multivariate linear and logistic regression models were performed. RESULTS: In 27,521 births, the lengths of first stage of labor did not differ significantly among groups in the multivariate analysis. In the second stage of labor, black women had shorter labors, both overall and stratified by epidural use. In the multivariate analysis, when controlled for demographics, parity, epidural, chorioamnionitis, birthweight, delivery year, and labor management, black women had a shorter second stage than did white women (nulliparous women, 22 minutes; multiparous women, 7.5 minutes; P < .001) and lower rates of prolonged second stage (odds ratio, 0.6; P < .001). Nulliparous Asian women had a significantly longer second stage and higher rates of prolonged second stage, and nulliparous Latina women had a shorter second stage, compared with nulliparous white women. CONCLUSION: When data are controlled for confounding factors, black women had a shorter length of second stage of labor than did women in other ethnic groups. These differences appear to be clinically significant. This contributes to the support of a multifactorial redefinition of labor curves, which are used widely in the management of labor.

Black or African American↗

Prophylactic intrapartum amnioinfusion in patients with preterm premature rupture of membranes.

Patients with preterm premature rupture of the membranes are at increased risk to develop intrapartum variable decelerations and fetal distress. Short-term saline solution amnioinfusion may be of benefit in the treatment of variable or prolonged decelerations once they appear. In an effort to assess the benefit of prophylactic amnioinfusion, patients with preterm premature rupture of the membranes were studied during a 1-year period in a prospective randomized manner. Patients receiving prophylactic amnioinfusion had significantly decreased incidence and severity of variable decelerations in the first stage of labor (p less than 0.005). In the second stage of labor, the incidence of severe (p less than 0.005) and total (p less than 0.001) decelerations was also decreased in the treatment group. The umbilical arterial pH at delivery was significantly lower (p less than 0.001) as was the umbilical venous pH (p less than 0.005) in the newborn infants of control patients compared with those of patients receiving amnioinfusion. This suggests that prophylactic intrapartum amnioinfusion is of significant benefit in reducing the incidence of variable decelerations and improving the metabolic state in newborn infants born to women with preterm premature rupture of the membranes.

Adult↗

Parity and pain during parturition.

A descriptive study was undertaken to investigate the differences in pain reported by 17 primiparous and 33 multiparous parturients. Subjects responded to the McGill pain questionnaire during the early, active, and transitional phases of the first stage of labor, and immediately after delivery for the second stage of labor. Although no significant main effect for parity on pain was identified by repeated measures analyses of variance, significant interaction effects suggested that primiparas may experience greater pain during early labor and less pain during second stage than multiparas.

Adult↗

Warm tub bath during delivery.

In a prospective study, 88 women bathed in a warm tub bath for 1/2-2 hours during first stage labor after a strictly normal pregnancy, ending with spontaneous onset of labor at term. A control group consisted of 72 women fulfilling the same criteria of normality during pregnancy and labor, but who did not want to take a warm tub bath during labor. Apart from the bath, the two groups followed the usual obstetric procedures of the Department. The cervical dilatation in the "bath group" was 2 1/2 cm/h compared with 1 1/4 cm/h in the "control group". Mean pain score in the bath group was higher at the start of the study, before the bath, and they experienced a pain relief during bath which was not observed in the control group. This difference may be due to bias. The use of morfica and the need for stimulation of labor contractions were both twice as high in the control group, but this difference was not significant. No differences were observed with regard to operative delivery, vaginal or perineal laceration or in bleeding during labor or postpartum. The total duration of labor was the same in the two groups and no differences in neonatal condition were observed. The bacterial contamination of the bath water was insignificant and there were no significant febrile episodes post partum.

Adult↗

Perinatal effects of cervical vibration.

Possible perinatal effects of elective cervical vibration during first-stage labor were studied in 20 subjects. Assessment of fetal status was based on biophysical and biochemical methods, whereas at birth the infant was evaluated clinically and biochemically. With the reservation required by the small sample it is concluded that cervical vibration by itself is perinatally safe.

Acid-Base Equilibrium↗

Is abnormal labor associated with shoulder dystocia in nulliparous women?

OBJECTIVE: This study was undertaken to examine the relationship between labor abnormalities and shoulder dystocia in nulliparous women. STUDY DESIGN: Nulliparous women whose delivery was complicated by shoulder dystocia were studied and compared with a control group selected based on the best possible match for race, labor type (spontaneous or induced), and birth weight. The duration of first and second stage of labor, as well as the rates of labor progress, were calculated and compared between groups. RESULTS: During this 4-year study period, there were 8010 nulliparous singleton deliveries of which 65 (0.8%) were complicated by shoulder dystocia. Compared with controls, there was no difference in the rate of cervical dilation in the active phase of the first stage of labor. In the shoulder dystocia group, more patients had a second stage of labor greater than 2 hours (22% vs 3%; P <.05) and had operative vaginal deliveries (26% vs 1.5%; P <.001). In shoulder dystocia cases with birth weight greater than 4000 g, 33% had a second stage of labor greater than 2 hours. CONCLUSION: In our population, the combination of fetal macrosomia, second stage of labor longer than 2 hours and the use of operative vaginal delivery were associated with shoulder dystocia in nulliparous women.

Adult↗

[Epidural analgesia and the course of delivery in term primiparas].

OBJECTIVES: Epidural analgesia provides the most effective pain control during labor. Of great concern is its influence on the course of delivery and perinatal complications. DESIGN: The aim of the study was to assess the effect of epidural analgesia on the course of delivery and perinatal outcome. MATERIALS AND METHODS: 609 deliveries among 1334 (323 women with epidural analgesia (53%) and 548 without epidural analgesia (47%)) met the following criteria: primipara, singleton, live pregnancy, > =37 weeks' gestation, cephalic presentation of a fetus, lack of contraindication for vaginal delivery. The incidence of instrumental deliveries and fetal distress, duration of the first, second and third stage of labor, perinatal outcome, perinatal complications and perinatal blood loss and were analyzed. RESULTS: The incidence of fetal distress during second stage of labor was significantly higher in the epidural group (12.69 vs. 6.99%, P=0.02). The incidence of fetal distress during first stage of labor did not differ in both groups (10.53% vs. 8.74%, NS). Cesarean sections rate was similar in epidural and non-epidural group (17.7 vs. 18.2%, NS). Among vaginal deliveries duration of the first and second stage of labor was longer in epidural group (6.5+/-2.4 vs. 5.4+/-2.5 godz., P=0,000003 and 47.3+/-34.8 vs. 29.1+/-25.8 min., P=0.000003) and this was independent of period of time between onset of first stage of labor and epidural analgesia. Oxitocin use was significantly more frequent in the epidural group (20.6 vs. 10.3%, P<0.004). There were no statistically significant differences in the rates of instrumental vaginal deliveries, 1 and 5-minute Apgar scores, length of third stage of labor and perinatal blood loss in patients with and without epidural analgesia. Perinatal outcome did not depend on previous use of epidural analgesia or mode of analgesia for the operation in cesarean section subgroup. CONCLUSION: Epidural labor analgesia is associated with slower progress of labor but has no adverse effect on perinatal outcome and perinatal complications.

Adult↗