PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “MAGNETICS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Magnetic confinement of electron and photon radiotherapy dose: a Monte Carlo simulation with a nonuniform longitudinal magnetic field.

It recently has been shown experimentally that the focusing provided by a longitudinal nonuniform high magnetic field can significantly improve electron beam dose profiles. This could permit precise targeting of tumors near critical areas and minimize the radiation dose to surrounding healthy tissue. The experimental results together with Monte Carlo simulations suggest that the magnetic confinement of electron radiotherapy beams may provide an alternative to proton or heavy ion radiation therapy in some cases. In the present work, the external magnetic field capability of the Monte Carlo code PENELOPE was utilized by providing a subroutine that modeled the actual field produced by the solenoid magnet used in the experimental studies. The magnetic field in our simulation covered the region from the vacuum exit window to the phantom including surrounding air. In a longitudinal nonuniform magnetic field, it is observed that the electron dose can be focused in both the transverse and longitudinal directions. The measured dose profiles of the electron beam are generally reproduced in the Monte Carlo simulations to within a few percent in the region of interest provided that the geometry and the energy of the incident electron beam are accurately known. Comparisons for the photon beam dose profiles with and without the magnetic field are also made. The experimental results are qualitatively reproduced in the simulation. Our simulation shows that the excessive dose at the beam entrance is due to the magnetic field trapping and focusing scattered secondary electrons that were produced in the air by the incident photon beam. The simulations also show that the electron dose profile can be manipulated by the appropriate control of the beam energy together with the strength and displacement of the longitudinal magnetic field.

Algorithms↗

Cellular uptake of magnetic fluid particles and their effects on human adenocarcinoma cells exposed to AC magnetic fields in vitro.

Suspensions of coated superparamagnetic particles (magnetic fluids, MF) in AC magnetic fields have a pronounced specific absorption rate (SAR) per mass compared to multidomain particles. The aim of the present study was to investigate cellular uptake and the biological effects of AC magnetic field excited bio-compatible magnetic fluids on human carcinoma cells in vitro. One of the fluids tested was a dextran magnetite, which has a very low cyto-toxicity with survival fractions (SF) between 0.8 and 0.9 at concentrations of up to 5 mg ferrite per ml. Human carcinoma cells intracellularly accumulate up to 1 pg ferrite/cell which has been demonstrated by electron microscopy (TEM), X-ray spectroscopy and measurements of intracellular iron. It has been shown that the ferrite core is not altered intracellularly, but many of the dextran shells are degraded which yields particle chains and other aggregates observed in TEM. Semi-solid pellets of the tumour cells were treated with AC magnetic fields (520 kHz, 4-12.5 kA/m) or waterbath hyperthermia at 43 and 45 degrees C, in presence of extracellular and/or intracellular magnetic fluid particles. Although MF heating is produced from individual particles, the survival fractions of MF heated and water bath heated cells are equal. In fact, the extracellular MF particle distribution is homogeneous enough to obtain similar inactivation. In contrast to earlier reports intracellular dextran magnetite particles in AC magnetic fields did not induce cell inactivation. Since the amount of intracellular ferrite should be indeed large enough for cell inactivation, the loss of dextran shells is most probably the main cause of limited effectiveness of the intracellular magnetite particles. The present work has demonstrated that: (1) MFH is able to inactivate tumour cells in vitro to at least the same extent as water bath hyperthermia; and (2) that there is a sensitizer effect of ferrofluids at 43 degrees C probably caused by free ferric ions which induce oxidative stress; and (3) that there is no cytotoxic effect of intracellular dextran magnetite particles 30-180 min excited with AC magnetic fields used in this study. For the new method the term 'magnetic fluid hyperthermia (MFH)' is proposed.

Adenocarcinoma↗

[Use of permanent magnets and magnetic fluids in experimental oncology].

The use of permanent magnets and magnetic fields (magnetic fluids and magnetic suspensions) alone or in complex with the antitumour compounds for the treatment of malignancies of various localizations is considered. Methods and forms of the use of permanent magnets are discussed. It is concluded that permanent magnets (as magnetic suspensions and magnetic fluids) used alone, in complex with chemical substances or in combination with other affecting factors (the temperature rise) induce a considerable regression of the tumour. Besides, permanent magnets may promote an increase of the antitumour drug concentration in the tissue of the diseased organ.

Albumins↗

Comparison of dobutamine stress magnetic resonance, adenosine stress magnetic resonance, and adenosine stress magnetic resonance perfusion.

BACKGROUND: Dobutamine stress MR (DSMR) is highly accurate for the detection of inducible wall motion abnormalities (IWMAs). Adenosine has a more favorable safety profile and is well established for the assessment of myocardial perfusion. We evaluated the diagnostic value of IWMAs during dobutamine and adenosine stress MR and adenosine MR perfusion compared with invasive coronary angiography. METHODS AND RESULTS: Seventy-nine consecutive patients (suspected or known coronary disease, no history of prior myocardial infarction) scheduled for cardiac catheterization underwent cardiac MR (1.5 T). After 4 minutes of adenosine infusion (140 microg x kg(-1) x min(-1) for 6 minutes), wall motion was assessed (steady-state free precession), and subsequently perfusion scans (3-slice turbo field echo-echo planar imaging; 0.05 mmol/kg Gd-BOPTA) were performed. After a 15-minute break, rest perfusion was imaged, followed by standard DSMR/atropine stress MR. Wall motion was classified as pathological if > or =1 segment showed IWMAs. The transmural extent of inducible perfusion deficits (<25%, 25% to 50%, 51% to 75%, and >75%) was used to grade segmental perfusion. Quantitative coronary angiography was performed with significant stenosis defined as >50% diameter stenosis. Fifty-three patients (67%) had coronary artery stenoses >50%; sensitivity and specificity for detection by dobutamine and adenosine stress and adenosine perfusion were 89% and 80%, 40% and 96%, and 91% and 62%, respectively. Adenosine IWMAs were seen only in segments with >75% transmural perfusion deficit. CONCLUSIONS: DSMR is superior to adenosine stress for the induction of IWMAs in patients with significant coronary artery disease. Visual assessment of adenosine stress perfusion is sensitive with a low specificity, whereas adenosine stress MR wall motion is highly specific because it identifies only patients with high-grade perfusion deficits. Thus, DSMR is the method of choice for current state-of-the-art treatment regimens to detect ischemia in patients with suspected or known coronary artery disease but no history of prior myocardial infarction.

Adenosine↗

[Combined conventional magnetic resonance, magnetic resonance angiography, and magnetic resonance cholangiopancreatography in the diagnosis and staging of pancreatic carcinoma].

PURPOSE: This study was aimed to integrating MR CholangioPancreatography (MRCP) and MR Angiography (MRA) to conventional MR images in the diagnosis and resectability assessment of pancreatic adenocarcinoma. MATERIAL AND METHODS: Twenty-three consecutive patients with pancreatic adenocarcinoma (16 in the head and 7 in the body-tail region) were examined with MR. Conventional MR, 3D MRCP and venous and arterial MRA images were acquired to assess biliary and vascular involvement. Acquisition time never exceeded 40-45 minutes. The images were independently studied by two radiologists and the final reading was decided upon consensus among readers. Sixteen patients underwent surgery. RESULTS: The diagnosis was confirmed at surgery in 16 patients and at percutaneous biopsy in 7. Interreader agreement was considered high, with .83 interobserver variability. Pancreatic adenocarcinoma was found in all patients examined. Unresectability because of vascular involvement was correctly assessed in all patients but 1. Biliary obstruction was demonstrated in 13 patients, involving the biliary and pancreatic ducts in 9 and the biliary ducts only in 4. CONCLUSION: Technical advances now permit the extensive application of MRI to the study of abdominal conditions. The combination of MRI, MRCP and MRA can provide most of the information needed for the diagnosis and resectability assessment of pancreatic adenocarcinoma, which can otherwise be obtained only performing three different exams.

Adenocarcinoma↗

Magnetically aligned phospholipid bilayers in weak magnetic fields: optimization, mechanism, and advantages for X-band EPR studies.

Our lab is developing a spin-labeled EPR spectroscopic technique complementary to solid-state NMR studies to study the structure, orientation, and dynamics of uniaxially aligned integral membrane proteins inserted into magnetically aligned discotic phospholipid bilayers, or bicelles. The focus of this study is to optimize and understand the mechanisms involved in the magnetic alignment process of bicelle disks in weak magnetic fields. Developing experimental conditions for optimized magnetic alignment of bicelles in low magnetic fields may prove useful to study the dynamics of membrane proteins and its interactions with lipids, drugs, steroids, signaling events, other proteins, etc. In weak magnetic fields, the magnetic alignment of Tm(3+)-doped bicelle disks was thermodynamically and kinetically very sensitive to experimental conditions. Tm(3+)-doped bicelles were magnetically aligned using the following optimized procedure: the temperature was slowly raised at a rate of 1.9K/min from an initial temperature being between 298 and 307K to a final temperature of 318K in the presence of a static magnetic field of 6300G. The spin probe 3beta-doxyl-5alpha-cholestane (cholestane) was inserted into the bicelle disks and utilized to monitor bicelle alignment by analyzing the anisotropic hyperfine splitting for the corresponding EPR spectra. The phases of the bicelles were determined using solid-state 2H NMR spectroscopy and compared with the corresponding EPR spectra. Macroscopic alignment commenced in the liquid crystalline nematic phase (307K), continued to increase upon slowly raising the temperature, and was well-aligned in the liquid crystalline lamellar smectic phase (318K).

Anisotropy↗

High-Nuclearity Magnetic Clusters: Generalized Spin Hamiltonian and Its Use for the Calculation of the Energy Levels, Bulk Magnetic Properties, and Inelastic Neutron Scattering Spectra.

A general solution of the exchange problem in the high-nuclearity spin clusters (HNSC) containing arbitrary number of exchange-coupled centers and topology is developed. All constituent magnetic centers are supposed to possess well-isolated orbitally non-degenerate ground states so that the isotropic Heisenberg-Dirac-Van Vleck (HDVV) term is the leading part of the exchange spin Hamiltonian. Along with the HDVV term, we consider higher-order isotropic exchange terms (biquadratic exchange), as well as the anisotropic terms (anisotropic and antisymmetric exchange interactions and local single-ion anisotropies). All these terms are expressed as irreducible tensor operators (ITO). This allows us to take full advantage of the spin symmetry of the system. At the same time, we have also benefitted by taking into account the point group symmetry of the cluster, which allows us to work with symmetrized spin functions. This results in an additional reduction of the matrices to diagonalize. The approach developed here is accompanied by an efficient computational procedure that allows us to calculate the bulk magnetic properties (magnetic susceptibility, magnetization, and magnetic specific heat) as well as the spectroscopic properties of HNSC. Special attention is paid to calculate the magnetic excitations observed by inelastic neutron scattering (INS), their intensities, and their Q and temperature dependencies. This spectroscopic technique provides direct access to the energies and wave functions of the different spin states of the cluster; thus, it can be applied to spin clusters in order to obtain deep and detailed information on the nature of the magnetic exchange phenomenon. The general expression for the INS cross-section of spin clusters interacting by all kinds of exchange interactions, including also the single-ion zero-field splitting term, is derived for the first time. A closed-form expression is also derived for the particular case in which only the isotropic exchange interactions are involved. Finally this approach has been used to model the magnetic properties as well as the INS spectra of the polyoxometalate anion [Ni(9)(OH)(3)(H(2)O)(6)(HPO(4))(2)(PW(9)O(34))(3)](16)(-), which contains a central magnetic cluster formed by nine exchange-coupled Ni(II) ions surrounded by diamagnetic phosphotungstate ligands (PW(9)O(34))(9)(-).

Journal Article↗

Hydrogen magnetic resonance spectroscopy follow-up after radiation therapy of human brain cancer. Unexpected inverse correlation between the changes in tumor choline level and post-gadolinium magnetic resonance imaging contrast.

RATIONALE AND OBJECTIVES: The anatomic and metabolic changes in human brain tumors treated by radiation therapy were compared using gadolinium-enhanced magnetic resonance imaging and hydrogen (1H) magnetic resonance spectroscopy. The study was intended to assess the potential of 1H magnetic resonance spectroscopy in monitoring response to therapy. METHODS: Thirteen cases of brain cancer treated by radiation therapy were examined by 1H magnetic resonance spectroscopy and gadolinium-enhanced T1-weighted magnetic resonance imaging and reexamined at 2-month intervals. RESULTS: Follow-up after radiation therapy showed changes in post-gadolinium magnetic resonance imaging contrast that are inversely correlated with the changes in choline level (r = -0.69, P < 0.00001) and in tumor volume (r = -0.35, P < 0.05). CONCLUSIONS: The choline loss in tumors gaining post-gadolinium magnetic resonance imaging contrast after therapy is unexpected in view of previously reported correlation between the two in untreated metastatic brain tumors. Indicated is the use of 1H magnetic resonance spectroscopy to discriminate enhancing brain tumors with a high content of vital tumor cells (high choline) from tumors, combining decreased cell density with increased interstitial space (low choline).

Aspartic Acid↗

Effects of magnetic resonance imaging on implantable permanent magnets.

Implantable permanent magnets are increasingly used in devices for otolaryngologic applications. It is likely that at least some of the patients with implanted magnets will be in need of magnetic resonance imaging (MRI). The effect of an MRI scan on the magnetic properties of implanted permanent magnets has not been previously demonstrated. Some of the basic concepts and descriptive terminology used in industry regarding permanent magnets are reviewed. Experiments presented show that the MRI scan is capable of demagnetizing permanent magnets. A case history is also presented that demonstrates demagnetizing of an implanted Audiant magnet by an MRI scan.

Hearing Aids↗

Effect of magnetic vs sham-magnetic insoles on plantar heel pain: a randomized controlled trial.

CONTEXT: Despite anecdotal reports, rigorous scientific evidence of the effectiveness of magnetic insoles for the pain of plantar fasciitis is lacking. OBJECTIVE: To determine whether magnetic insoles provide greater subjective improvement for treatment of plantar heel pain compared with identical nonmagnetized insoles. DESIGN, SETTING, AND PARTICIPANTS: Randomized, double-blind, placebo-controlled trial conducted from February 12, 2001, to November 9, 2001, of a volunteer sample of 101 adults with diagnoses of plantar heel pain for at least 30 days from a multispecialty group practice clinic in Rochester, Minn. Daily pain diaries were kept for 8 weeks. INTERVENTIONS: Cushioned insoles, with either active bipolar magnets or sham magnets, which were worn daily by the participants for 8 weeks. MAIN OUTCOME MEASURES: Reported average daily foot pain (by metered visual analog scale [VAS] and by categorical response of change from baseline) at 4 and 8 weeks, and impact of insoles on employment performance and enjoyment. RESULTS: No significant between-group differences were found on any outcome variables studied when comparing active vs sham magnets. Both the nonmagnetic and magnetic groups reported significant improvements in morning foot pain intensity, with mean (SD) VAS scores improving from 6.9 (2.3) and 6.7 (2.0), respectively, at baseline to 3.9 (2.6) for each group at 8 weeks (P =.94). At 8 weeks, 33% of the nonmagnetic group and 35% of the magnetic group reported being all or mostly better (P =.78). At baseline, foot pain interfered moderately with participants' employment enjoyment (mean VAS, 4.2) and improved in both groups by 8 weeks (1.3 and 1.5, respectively; P =.68). CONCLUSION: Static bipolar magnets embedded in cushioned shoe insoles do not provide additional benefit for subjective plantar heel pain reduction when compared with nonmagnetic insoles.

Adult↗

Effects of coil orientation and magnetic field shield on transcranial magnetic stimulation in cats.

To obtain suitable stimulus conditions for transcranial magnetic stimulation, the evoked compound muscle action potential (ECMAP), evoked spinal cord potential (ESCP), and magnetic and electric fields were analyzed in cats with and without the use of a magnetic field shield. Cats were stimulated using a figure 8 magnetic coil placed on the cranium above the motor cortex. The maximum ECMAP amplitude was recorded when the electric current in the coil was in the mediolateral direction, regardless of whether a magnetic shield with a 5 x 5 cm window was used. ECMAP and ESCP thresholds were reduced when magnetic shielding was in place. Due to the edge effect, the strengths of the magnetic and electric fields were highest in the brainstem area, which is an inhomogeneous volume conductor of the cat's cranium. A large induced electric field directed caudally elicited ECMAP and ESCP responses effectively when a magnetic shield with a 5 x 5 cm window was in place.

Action Potentials↗

Growth of human cultured cells exposed to a non-homogeneous static magnetic field generated by Sm-Co magnets.

A static magnetic field, with a strong spatial gradient, was established on the surface of cell culture dishes by use of a gilded iron needle set vertically above an Sm-Co magnet. The calculated magnetic flux density was more than 1.5 T at the center of the needle tip, and the products of the flux density and its gradient were about 200 and 60 T2/m at distances of 0.1 and 0.3 mm, respectively, from the center. The DNA content, DNA synthesis and labeling index of cultured cells located within 0.1 mm from the center of the needle, and the growth rate of cells located within 0.3 mm from the center, were measured. HeLa cells grew at a normal rate for 96 h in the magnetic field and showed no significant change in shape, detectable by scanning electron microscopy. The growth of HeLa cells was not influenced by exposure to the magnetic field. Similarly, exposure for 48 h to the magnetic field had no effect on growth of normal human gingival fibroblasts (Gin-1). The DNA content, assayed by microfluorometry of the nuclei of both types of cells stained by the Feulgen reaction, was not significantly different from that of controls. Moreover, exposure to the magnetic field had no effect on DNA synthesis or the labeling index of HeLa cells assayed by autoradiography of incorporated [3H]thymidine. It is concluded that a non-homogeneous magnetic field of the intensity and the gradient used in this study does not significantly influence the growth of HeLa cells or Gin-1 cells.

Cells, Cultured↗

Magnetic Marker Monitoring: An application of biomagnetic measurement instrumentation and principles for the determination of the gastrointestinal behavior of magnetically marked solid dosage forms.

Magnetic Marker Monitoring offers an alternative to investigate the behavior of solid dosage forms in the organs of the gastrointestinal tract without the need to apply radiation. For Magnetic Marker Monitoring, the dosage form is marked as a permanent magnetic dipole by the incorporation of small amounts of ferromagnetic material, as for example the colorant black iron oxide, and subsequent magnetization. Thereby, the dosage form is labeled as the source of a well defined magnetic field, which can be measured using a measurement technique that is established for biomagnetic investigations. Using the established concepts for magnetic source localization, the three dimensional localization and orientation as well as the strength of the magnetic source can be reconstructed from these magnetic measurement data as a function of time. Furthermore, it is possible to gain quantitative information on the disintegration of dosage forms in vivo. Examples are given for results obtained concerning the esophageal transit, the gastric and the intestinal behavior of capsules and tablets.

Capsules↗

Novel detection system for biomolecules using nano-sized bacterial magnetic particles and magnetic force microscopy.

A system for streptavidin detection using biotin conjugated to nano-sized bacterial magnetic particles (BMPs) has been developed. BMPs, isolated from magnetic bacteria, were used as magnetic markers for magnetic force microscopy (MFM) imaging. The magnetic signal was obtained from a single particle using MFM without application of an external magnetic field. The number of biotin conjugated BMPs (biotin-BMPs) bound to streptavidin immobilized on the glass slides increased with streptavidin concentrations up to 100 pg/ml. The minimum streptavidin detection limit using this technique is 1 pg/ml, which is 100 times more sensitive than a conventional fluorescent detection system. This is the first report using single domain nano-sized magnetic particles as magnetic markers for biosensing. This assay system can be used for immunoassay and DNA detection with high sensitivities.

Bacterial Proteins↗

Magnetic split-flow thin fractionation of magnetically susceptible particles.

We recently built a magnetic separation system to extend the applications of split-flow thin (SPLITT) fractionation to magnetically susceptible particles. Here, we characterize the magnetic SPLITT system using magnetically susceptible particles and ion-labeled particles. The flow axis of separation channel was orientated parallel and perpendicular to gravitational forces to exclude and include, respectively, gravitational effects on separation. Both operating modes were used to test the theory experimentally, with emphasis on the parallel mode. The magnetic susceptibilities of carrier and ion-labeled particles were varied, and various ion-labeled and unlabeled particles were studied experimentally, resulting in successful separation of labeled particles, yeasts, and cells from unlabeled ones. The minimal difference in magnetic susceptibility (delta(chi)) required for complete particle separation was about 1.75 x 10(-5) [cgs], corresponding to about 10(9) labeling ions per particle in this study. The throughput was around 7.2 x 10(8) particles/h using the present setup. Magnetic SPLITT fractionation shows good potential for use in obtaining particles magnetic susceptibilities from a simple theoretical treatment.

Ions↗

Acyclovir serum concentrations following peroral administration of magnetic depot tablets and the influence of extracorporal magnets to control gastrointestinal transit.

In the present investigations peroral acyclovir depot tablets with internal magnets were developed. An extracorporal magnet was used to prolong the gastric residence times of the dosage forms and to influence the duration of absorption of acyclovir. The magnetic depot tablets contained 200 mg acyclovir. In a three-way cross-over in vivo study with five healthy male subjects, the plasma concentration-time profiles of acyclovir were determined. The acyclovir plasma concentrations following peroral administration of magnetic depot tablets in the presence and absence of an extracorporal magnet were determined. A commercially available immediate release preparation was used as a reference preparation. In the presence of an extracorporal magnet which was placed in the stomach region, the plasma concentrations of acyclovir were significantly higher after 7, 8, 10 and 12 h (P<0.05, U-test, Wilcoxon, Mann-Whitney). The mean area under the plasma concentration-time-curve (AUC0-24h), in the presence of the extracorporal magnet was 2802.7 ngh/ml. Without the extracorporal magnet a mean AUC0-24h of 1598.8 ngh/ml was achieved. Computer simulations were carried out to show the influence of the gastric residence time of acyclovir depot preparations on the plasma concentration-time profiles of acyclovir.

Acyclovir↗

Safety of the magnetic field generated by a neuronal magnetic stimulator: evaluation of possible mutagenic effects.

OBJECTIVE: The possible mutagenicity of a magnetic stimulus was checked using the Ames test with Salmonella typhimurium TA98 and TA100 as tester strains. METHODS: Samples of these bacteria were exposed to a pulsed magnetic field, on the order of 1 T. The magnetic pulses were generated by a neuronal magnetic stimulator with a flat coil. The magnetic stimulus was a continuous sequence of slightly damped half sinusoids at a rate of 5 pulses/s. Exposure times were 2-5 and 15 min. Exposure position was such as to maximise the magnetic field and minimise the induced electric field. Room temperature was maintained at 28.5 +/- 0.5 degrees C and the temperature was measured inside the samples. RESULTS: None of the exposure conditions showed any increase in mutation in either of the two bacterial strains. CONCLUSIONS: These results are discussed in comparison with effects found in the literature. The magnetic stimulation used under the conditions of this study does not appear to have mutagenic effects. This does not apply to cases where both strong electric and magnetic fields are present.

Electric Stimulation↗

Magnetic properties of magnetically soft nanocomposite Co-SiO2 prepared via mechanical milling.

Nanocomposite of Co-SiO2, a soft magnetic material, with Co weight fraction x = 0.3 and 0.7 was prepared via mechanical milling. The magnetic properties of these samples, both zero-field-cooled (ZFC) and field-cooled (FC), have been measured as a function of x, milling time, and temperature. The structural assessment of the composite indicates a presence of only ferromagnetic (FM) hcp-Co phase in the composite. However, reported magnetic properties of these composites appear to be dependent on the presence of antiferromagnetic (AFM) phases of cobalt oxide as well. The observed enhancement in ZFC coercivity and a reduction in saturation magnetization with the milling time are due to an increase in defect density upon milling. The ZFC coercivity for the x = 0.3 samples has been found to be much higher than the x = 0.7 samples for all milling times. The coercivity above 50 K depends on temperature according to the law corresponding to isotropic uniaxial superparamagnetic particles. Below 50 K the presence of an AFM phase Co3O4 (TN approximately 33 K) and increased interparticle interactions bring in a departure from that law. The saturation magnetization is found to be temperature dependent for the x = 0.3 samples and temperature independent for the x = 0.7 samples, which further provides evidence of the presence of higher AFM phase fraction in the composite with a low metal volume fraction. The FC magnetic measurements show a presence of an exchange bias field and an enhanced coercivity which are higher than the ZFC measurements. All magnetic measurements indicate that the overall magnetic properties of the composite are dictated by the presence of a trace amount of cobalt oxides.

Cobalt↗