PubMed HealthSearch

SEARCH · PubMed Health

Results for “Materials Testing”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Analytic study of the Tadoma method: discrimination ability of untrained observers.

This study reports the ability of two observers with normal-hearing and sight to discriminate pairs of speech elements through the Tadoma method of speechreading. The observers were blindfolded and exposed to masking noise to eliminate visual and auditory cues. They placed their right hand over the speaker's face and neck so that the thumb rested lightly on the lips and the fingers fanned out over the cheek and neck. The discrimination tests were conducted using an ABX procedure. Average discrimination scores for the five types of test materials used in the ABX tests were 87% on W-22 words, 83% on Modified Rhyme Test words, 70% on vowels, 77% on CV and VC nonsense syllables, and 71% on consonant clusters. In all of the ABX tests, the inexperienced observers performed at least as well as the experienced Tadoma user studied by Norton, et al (1977). This finding indicates that the basic tactile sensitivity of inexperienced observers is comparable to that of an experienced deaf-blind Tadoma user.

Cues

Microimmunodiffusion test for diagnosis of ovine progressive pneumonia.

Two microimmunodiffusion tests (MIDT) for detection and measurement of ovine progressive pneumonia antibody are described. Substrates of various salt concentrations and pH were used to determine the optimal conditions for the tests. In comparisons between two MIDT and one macroimmunodiffusion test, sera from cull ewes were used. The MIDT require less reagents and were more responsive than the macroimmunodiffusion test. After extended incubation of the test materials, results in all three tests were comparable.

Animals

Enamel bonding plastic materials in modifying the form of abutment teeth for the better functioning of partial prostheses.

The potential uses of enamel bonding sealants and composite filling materials in increasing the retentive form of abutment teeth and covering the preparations for the occlusal supports of partial prostheses were studied in laboratory conditions. The materials tested were Nuva and Concise sealants and composite resins. Extracted permanent human molars, premolars and canines were inserted into acrylic blocks, two teeth in each block. An unretentive clasp framework was made on every test block. A retention prominence was built up separately of sealants and of composite materials occlusally to the tip of each clasp arm. The bond strength and wear resistance of the materials was tested in a device designed for this study. The bond of the prominences was very good, only two out of 114 prominences loosened. The retention gained with prominences was, on average, 18 N measured by the force needed for removal. The decrease in the total retention of the four clasp arms was measured by the force needed to remove the clasp framework. The total retention of the prominences made of Nuva and Concise sealants after 5000 removals was 53 and 50% of the original, when long, flexible clasp arms were used. The corresponding figures for composite resins were 56 and 59%. Short rigid clasp arms caused a distinctly faster abrasion. The prominences made of sealants, in particular, were abraded rapidly, one-fifth of retention being left after 3000 removals.

Composite Resins

[Technological studies on high pressure polymerization of dental plastic materials].

The author in his present paper reports a program of comparative materials testing of which the purpose was to assess the value of positive pressure polymerization of thermosets. This particular program required polymerization temperature measurements. K-value determinations, and cone indentation hardness tests to be made on samples of plastic material polymerized under positive liquid or steam pressure and in cuvets, respectively, the conditions of polymerization being those which are used in actual practice. The results obtained indicated a favorable influence of positive liquid pressure polymerization on the final hardness of the plastic material.

Dental Materials

[Mutual relations between plastic materials and bacteria (author's transl)].

The complex problems of microbiological degradation of synthetic plastics and a fairly wide variety of 62 testing materials, belonging to 14 major groups of plastics, are described. Adaequate and reliable testing techniques had to be devised. Drawing on the experiences of H. Braun, 1930, and of Bushnell and Haas, 1941, as to the metabolism of bacteria and the utilization of certain hydrocarbons by microorganisms, and previous research work by A. Schwartz in Berlin, 1959-60, on microbial corrosion of plastics, methods of laboratory testing were developed. The bacteriological technique was based on selection of aerobic microorganisms, which were, by starvation, adapted to use the plastic materials as their only carbon source; foreign carbon sources had to be strictly eliminated; emphasis was laid on proper, double control cultures. The test organisms involved included P. aeruginosa and fluorescens strains, also a certain species of Candida, and mixtures of soil, sewage and garbage organisms grown on exposed plastic surfaces. By means of series of passages the selective adaptation and conservation of these organisms was continued up to 4 1/2 years. An anaerobic adaptation method for Desulfovibrio desulfuricans was developed and used successfully. After preliminary experimentation (Soil burial, sewage and garbage exposure tests) in the laboratory as well as in the open, a large scale Field testing programme under realistic and to some extent extreme conditions was implemented: Nine different plastic materials comprising eight plain high polymer plastics and for comparison one synthetic Cellulose derivate, together with glass control samples, were exposed in twelve different sewage, garbage, and soil media over a period of 3 months to 2 years, and subsequently examined. On the basis of the bacteriological results obtained from the adaptation series the test materials were classified into three categories, corresponding to the stimulation of bacterial growth: Group one, which allowed strong proliferation, included certain types of plasticized P.V.C. and Cellulose esters, as expected, and, as a new result, Polyurethane rubber; the latter showed clear signs of surface corrosion. Group two, which induced a clear but moderate growth, comprised a nylon trade type of Polyamide. Gruop three, allowing weak but still recognisable growth, included Formaldehyde pressure resing (Bakelite). This was surprising as it was thought that the formaldehyde and phenol components would exert a bacteriocidic or at least bacteriostatic effect. The results of the long and time consuming adaptation series with Pseudomonas aeruginosa were confirmed by the manometric dissimilation method of O. Warburg by means of the Braun/Melsungen apparatus. With this subtle but elegant procedure results and graphical recordings were obtained within hours and days...

Candida

Sensitivity to isopropyl alcohol.

Positive patch test reactions to isopropyl alcohol in connection with proved allergy to ethyl alcohol have already been published. A case of allergy to isopropyl alcohol with positive reactions to isopropanol (unpurified test material) and negative reactions to ethanol and methanol has also been reported. We report a case of a occupationally acquired sensitivity to isopropyl alcohol in which, on testing with gas chromatographically purified material, positive patch test reactions were found to 1-propanol, 1-butanol, 2-propanol, 2-butanol and methanal (formaldehyde) but not to the primary alcohols methanol, ethanol and amyl alcohol; not to the aldehydes acetal (acetaldehyde) and butanal; nor to the ketones acetone, butanon and isobutyl ketone, nor to methanoic (formic)acid. A tentative explanation for this peculiar pattern of reactions is given.

1-Propanol

Contact angles and wetting of pharmaceutical powders.

Contact angles of pharmaceutical powders were determined by the h-epsilon method, which consists essentially of measuring the maximum height of a drop of liquid fomed on a presaturated compact of the material. Determinations with aspirin as the test material indicate that the measured value is independent of the particle size of the powder and the porosity of the cake. The method was extended to include determinations on mixed powder systems. The results show that the hydrophobic material dominates with large particle-size powders; with small particle sizes, a linear relationship between the cosine of the contact angle of the mixed system and the proportion of the components is obtained. Results are presented for a wide variety of materials of pharmaceutical interest.

Aspirin

Assessment of tissue conditioning materials for functional impressions.

The validity of two types of tissue conditioning materials was studied and compared with that of two commonly used impression materials. The effect of three important factors on the accuracy of the impressions was observed. These factors were thickness of the impression material, time of compression of the impression, and the time interval before pouring the impression. A chrome-cobalt master cast was specially designed and 500 impressions were made and poured, resulting in 900 casts. Conclusions reached from this investigation were that: 1. Visco-Gel and Coe-Comfort tissue conditioning materials can be used as impression materials. 2. The dimensional accuracy of Visco-Gel is better than that of the Coe-Comfort impressions. 3. There is no significant difference between using a tray with a space of 1.5 mm or 3.0 mm for the impression material. 4. The less bulky the impression, the less time is required for compression with fewer inaccuracies. 5. It is preferable to pour the cast in the impression immediately or within 2 hours. 6. Both kinds of materials tested can be used as duplicating materials under certain conditions.

Dental Impression Materials

Characterization of cross-linked two-phase acrylic polymers.

A cross-linked network was formed in the particulate disperse phase carried over from the soluble pearls only in one material tested (L). The preparation of this material involved a slow rate of polymerization that allowed sufficient time for imbibition of the cross-linking monomer by the particles. In two of the materials (CR and S), the particulate phase was extractable and the remaining cross-linked matrix could be characterized for equilibrium swelling by volumetric measurements. Equilibrium swelling values were used to estimate densities of elastically effective chains in the network.

Acrylic Resins

Performance of high frequency impaired listeners with conventional and extended high frequency amplification.

This study sought to determine if a high-pass hearing aid can provide increased improvement in word recognition and consonant discrimination over that of a conventional high frequency emphasis hearing aid in listeners with hearing loss limited to frequencies above 1 000 Hz. Word and consonant discrimination were assessed in quiet and in the presence of 12 talker speech babble for 10 subjects under three listening conditions: (1) unaided; (2) wearing a conventional high frequency emphasis hearing aid, and (3) wearing an experimental high-pass instrument. The speech testing materials included: (1) Northwestern University Auditory Test No. 6; (2) California Consonant Test, and (3) eight voiceless English consonants. Results suggested that both instruments provided similar benefit in quiet for improving word recognition and resolving consonant errors. For the noise condition, however, the experimental high-pass aid provided a considerable advantage in both word recognition and consonant identification and was particularly sensitive to reducing within- and between-manner voiceless consonant confusions. Furthermore, measurements of real-ear gain revealed that the high-pass aid afforded considerably greater acoustic gain above 4 000 Hz than that shown for the conventional high frequency emphasis hearing aid,20

Adult

[Microretention of plastic filling materials on acid etched enamel].

In order to study the strength of the physical bond between composite materials and acid etched enamel, various commonly used composites were applied to the conditioned surface of extracted young permanent bicuspids. The specimens were stored in saline at 37 degrees C for one week and nine weeks and then subjected to tensile strength test. The following composites were tested: Restodent, Nuva Seal/Nuva Fil, Cosmic, Smile, Adaptic and Concise Enamel Bond. The latter was used in 4 different ways. The results of the study indicate that all the tested materials have a fairly good retention on the conditioned enamel. However, when using Concise Enamel Bond, care must be taken not to let the pure, liquid resin polymerize on the enamel before applying the composite, because this will give a poor bonding between the enamel and the filling. In addition to the tensile strength test, the materials were submitted to scanning electron microscop, to examine their penetration ability into conditioned enamel. The results of this study seem to indicate that the resin part of viscous composites (Cosmic and Concise pastes) was able to penetrate into the crevices of the etched enamel as well as the more fluid types (Restodent, Nuva Seal and diluted Concise).

Acrylic Resins

Critical evaluation of prosthetic materials in repair of abdominal wall hernias: new criteria of tolerance and resistance.

Six different materials (3 mesh and 3 cloth) commonly used for the repair of abdominal wall hernias were evaluated in 180 rats after implantation through musculature and peritoneum. Serial macroscopic and bacteriologic investigations were done, and bursting strength of the wound was determined in all groups at intervals with an original device. Histologic criteria were used to characterize the resistance of the wound and the tolerance of the host to the foreign material. Statistical analysis of the results demonstrated: (1) after postoperative day 15, the resistance of the wound was similar for each material tested; (2) during this early period mesh materials exhibited more resistance to bursting pressures than cloth materials; (3) the incorporation of mesh material was constant, whereas encystment or extrusion was always observed after implantation of cloth material; (4) no infection occurred with mesh material, but significant bacteria were found in 18 per cent of cloth material implantations; (5) the extent of the cellular reaction, the enumeration of giant, inflammatory, and fibroblastic cells showed the superiority of mesh materials; and (6) the ratio of fibroblasts to inflammatory cells reflected closely the mechanical resistance and tolerance of the foreign material.

Abdominal Muscles

Material effects in shear-induced hemolysis.

A rotating-disk apparatus for shearing blood was employed to compare 22 materials for their tendency to cause hemolysis during standardized low-stress (130 dynes/cm2 maximum) laminar flow conditions. Rigid plastics, hydrogels, and carbons were among the materials tested. Time-independent ranking of the materials was possible for 75% of the data; these rankings correlated linearly (for polymers) with the critical surface tension gammac over the range 20--46 dyne/cm, with low gammac being associated with low hemolysis. Surface morphology was also found to influence hemolysis. Roughness in the 1--15 micron range had a distinct effect on hemolysis kinetics for polyethylene surfaces. This suggest that failure to find time-independence in 25% of the material rankings can be attributed to inadequate control of the roughness variable. It also emphasizes the importance of surface morphology, as well as surface chemistry, as a biocompatibility parameter.

Acrylamides

Potentially thrombogenic materials in factor IX concentrates.

Factor XI concentrates manufactured from human plasma and intended for therapeutic infsuion in man have been suspected for some time of being potentially thrombogenic. In the current studies, assays were carried out in vitro and in vivo for potentially thrombognic materials. It was possible to rank the various materials tested according to the amount of thromboninic material detected. For concentrates not containing heparin, there was substantial agreement between the in vivo and in vitro assays, with a coefficient of correlation of 0.77. There was no correlation between the assays for thrombogenicity and the antithrombin III content. We conclude that many presently availabel concentrates of Factor IX contain substantial amounts of potentially thrombogenic enzymes, and that this fact must be considered in arriving at the decision whether or not to use them therapeutically.

Animals

[Resistance and biological tolerance of six "inert" parietal protheses. Experimental and critical study (author's transl)].

Six different materials (3 mesh and 3 cloth) commonly used for the repair of abdominal wall hernias were evaluated in rats. 490 animals, distributed among four experimental groups, were implanted with one of the different prostheses through musculature and peritoneum. Serial macroscopic and bacteriological investigations were done. Using an original device, bursting strength of the wound was determined in all groups at intervals. Histological criteria were used to characterize the resistance of the wound and the tolerance of the host to foreign material. Statistical analysis of the results demonstrated that: 1) after the 15th post-operative day, the resistance of the wound was similar for each material tested; 2) during this early period mesh materials exhibited more resistance to bursting pressures than cloth materials; 3) the incorporation of mesh material was constant whereas encystment or extrusion was always observed after implantation of cloth material; 4) no infection occurred with mesh material but significant bacteria were found in 18 p. 100 of cloth material implantations; 5) the extent of the cellular reaction, the enumeration of giant, inflammatory cells and fibroblasts showed superiority of mesh material; 6) the ratio of fibroblasts/inflammatory cells reflected closely the mechanical resistance and tolerance of the foreign material.

Animals

Effects of polyvinyl chloride ingestion by dogs.

Polyvinyl chloride (PVC) acrylic thermoplastic sheeting was fed to 6 dogs to determine whether ingestion during periods of normal transit of military working dogs would be toxic and thus affect the safety of this material for construction of shipping containers. The test dogs were fed PVC acrylic (0.125 g/kg of body weight; by gelatin capsule) twice each day for 5 days: for 2 dogs, the test material was in a shredded form; for 2 dogs, the material was diced; and for 2 dogs, it was powdered. Two other dogs were used as controls. Dogs were observed for clinical signs, and feed consumption and body weights were recorded. Blood and urine samples were examined. All animals were necropsied approximately 10 days after the feeding was stopped. Clinical or pathologic indication of a toxic effect of PVC was not seen within the time limits of the study.

Animals

[Composites versus amalgam: comparative measurements of abrasion resistance in vivo: 1-year results].

A method for the in-vivo measurement of wear resistance of restorative materials is described. A profilometer is used to record the reduction in vertical dimension of the test material's occlusal surface. This loss of substance is calculated as the wear resistance index. The technique was used in a 13 month clinical evaluation of 3 different restorative materials, Adaptic, Amalgam (Dispersalloy) and Estic microfill. The procedure is simple in execution and very accurate. Statistical analysis has shown significant differences in wear resistance of the examined materials independent of patient variation. Attrition and abrasion were definitely greater with a standard composite material (Adaptic) than with amalgam and a test composite (Estic microfill). The newly developed composite material utilizing extremely fine filler particles of pyrogenic SiO2 (Estic microfill) was shown to be comparable to amalgam in wear resistance during the 13-month test period.

Adult