PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microscopy, Scanning Probe”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

[Scanning probe microscopy for the study of morphological parameters of neutrophilic granulocytes].

Morphological parameters of human blood neutrophilic granulocytes were studied by scanning probe microscopy. The basic morphological characteristics of the living (unfixed) and fixed cells were compared. It was found that using the method described, the dimensions of the cells changed substantially and significantly depending upon the mode of fixation applied. The methanol fixation allowed to demonstrate the internal structure of a cell, though it sharply deformed the object of study. After glutaraldehyde fixation cells possessed the morphological characteristics similar to those of the living cells, but the diameter and height of the fixed cells were again different from those of living cells. The resolution of a scanning probe microscope was higher when the fixed cells were studied, permitting the visualization of a detailed cell structure, including the nucleus and cytoplasmic granules (in particular, when methanol fixation was used). However, this method of study is unreliable for the determination of cell dimensions (diameter and height).

Cell Size↗

Erythrocytotoxicity of tiazofurin in vivo and in vitro detected by scanning probe microscopy.

Tiazofurin (TZF) is a cytostatic drug that leads to depletion of the GTP pool in tumor and normal cells via its active metabolite tiazofurin-adenine dinucleotide (TAD). TAD was detected in different cell lines, but not in erythrocytes, so the mechanism of erythrocytotoxicity of TZF remains unclear. The purpose of this study was to evaluate in vitro and in vivo action of tiazofurin on rat erythrocytes (RBC). After two decades of clinical trials the question of erythrocytotoxicity of TZF had remained unexplained making this study justified. Since we have previously demonstrated early erythrocytotoxic effects in male Wistar rats, we extend this finding on isolated RBC. Isolated erythrocytes from untreated animals were treated in buffered solution or plasma containing TZF. In addition, groups of 10 rats were treated with 200 and 1000 mg/kg of TZF and hematologic parameters were analyzed by flowcytometry and by the analysis of the peripheral blood smears. Early signs of hemolysis or aberrant structures were monitored by scanning probe microscopy (SPM). We suggest that correlation exists between early erythrocytotoxicity and irregularities in erythrocyte morphology and membrane integrity. We also found that TZF affects responsiveness to oxidative stress. This is in concordance with flowcytometric findings describing anisocytosis and anisochromosis of RBC.

Animals↗

Calibration and examination of piezoresistive Wheatstone bridge cantilevers for scanning probe microscopy.

This paper describes the method of determining the force constant and displacement sensitivity of piezoresistive Wheatstone bridge cantilevers applied in scanning probe microscopy (SPM). In the procedure presented here, the force constant for beams with various geometry is determined based on resonance frequency measurement. The displacement sensitivity is measured by the deflection of the cantilever with the calibrated piezoactuator stage. Preliminary results show that our method is capable of measuring the force constant of Wheatstone bridge cantilevers with an accuracy of better than 5% and this is used as feedback for improvement of sensor micromachining process.

Journal Article↗

Potentiostatic deposition of DNA for scanning probe microscopy.

We describe a procedure for reversible adsorption of DNA onto a gold electrode maintained under potential control. The adsorbate can be imaged by scanning probe microscopy in situ. Quantitative control of a molecular adsorbate for microscopy is now possible. We found a potential window (between 0 and 180 mV versus a silver wire quasi reference) over which a gold (111) surface under phosphate buffer is positively charged, but is not covered with a dense adsorbate. When DNA is present in these conditions, molecules adsorb onto the electrode and remain stable under repeated scanning with a scanning tunneling microscope (STM). They become removed when the surface is brought to a negative charge. When operated at tunnel currents below approximately 0.4 nA, the STM yields a resolution of approximately 1 nm, which is better than can be obtained with atomic force microscopy (AFM) at present. We illustrate this procedure by imaging a series of DNA molecules made by ligating a 21 base-pair oligonucleotide. We observed the expected series of fragment lengths but small fragments are adsorbed preferentially.

Base Sequence↗

Piezoresistive sensors for scanning probe microscopy

In this article we summarize the efforts devoted to the realization of our ideas of the development of piezoresistive sensor family used in scanning probe microscopy. All the sensors described here are fabricated based on advanced silicon micromachining and standard CMOS processing. The fabrication scenario presented in this article allows for the production of different sensors with the same tip deflection piezoresistive detection scheme. In this way we designed and fabricated, as a basic sensor, piezoresistive cantilever for atomic force microscopy, which enables surface topography measurements with a resolution of 0.1 nm. Next, by introducing a conductive tip isolated from the beam we obtained a microprobe for scanning capacitance microscopy and scanning tunneling microscopy. With this microprobe we measured capacitance between the microtip and the surface in the range of 10(-22) F. Furthermore, a modification of the piezoresistors placement, based on the finite element method (FEM) simulation permits fabrication of the multipurpose sensor for lateral force microscopy, which enables measurements of friction forces with a resolution of 1 nN. Finally, using the same basic device idea and only slightly modified process sequence we manufactured femtocalorimeter for the detection of heat energy in the range of 50 pJ.

Journal Article↗

Surface-deformation characteristics of uniaxially oriented poly(ethylene terephthalate) film as evaluated from nanoscratch tests with scanning probe microscopy.

The surface-deformation characteristics of uniaxially drawn poly(ethylene terephthalate) (PET) film were successfully evaluated with multiline scratch tests using scanning probe microscopy (SPM) on a nanometer scale. The PET film was prepared by compression molding from the melt, followed by quenching in ice water. The obtained amorphous film was drawn uniaxially below its glass-transition temperature, and the resultant surface roughness could be reduced to within 5 nm. A multiline scratch with the Si(3)N(4) tip of an SPM on the oriented PET surface was made parallel and perpendicular to the drawing axis under applied loads of 5-30 nN. The perpendicular scratching generated a characteristic periodic pattern on the film surface, but the parallel scratching induced a tearing of the surface. These results suggest that surface-deformation mechanisms were dominated by molecular anisotropy. The surface-deformation properties, as evaluated from scratch-angle dependences on morphological changes on a nanometer scale, were similar to the mechanical properties of the bulk.

Journal Article↗

Single-nanoparticle-terminated tips for scanning probe microscopy.

We have developed a wet-chemistry procedure to attach a 10-40 nm colloidal gold nanoparticle to the top of a scanning probe microscopy (SPM) probe tip, making experiments of single nanoparticle interaction possible. This procedure of particle attachment is flexible and can be modified to attach nanoparticles of different kinds and sizes. The single-nanoparticle-terminated tips also have potential in various other applications, such as probes of enhanced sensitivity for optical and magnetic modes SPM.

Journal Article↗

Determination and correction of position detection nonlinearity in single particle tracking and three-dimensional scanning probe microscopy.

A general method is presented for determining and correcting nonlinear position detector responses in single particle tracking as used in three-dimensional scanning probe microscopy based on optical tweezers. The method uses locally calculated mean square displacements of a Brownian particle to detect spatial changes in the sensitivity of the detector. The method is applied to an optical tweezers setup, where the position fluctuations of a microsphere within the optical trap are measured by an interferometric detection scheme with nanometer precision and microsecond temporal resolution. Detector sensitivity profiles were measured at arbitrary positions in solution with a resolution of approximately 6 nm and 20 nm in the lateral and axial directions, respectively. Local detector sensitivities are used to reconstruct the real positions of the particle from the measured position signals.

Journal Article↗

Bioreactive self-assembled monolayers on hydrogen-passivated Si(111) as a new class of atomically flat substrates for biological scanning probe microscopy.

This is the first report of bioreactive self-assembled monolayers, covalently bound to atomically flat silicon surfaces and capable of binding biomolecules for investigation by scanning probe microscopy and other surface-related assays and sensing devices. These monolayers are stable under a wide range of conditions and allow tailor-made functionalization for many purposes. We describe the substrate preparation and present an STM and SFM characterization, partly performed with multiwalled carbon nanotubes as tapping-mode supertips. Furthermore, we present two strategies of introducing in situ reactive headgroup functionalities. One method entails a free radical chlorosulfonation process with subsequent sulfonamide formation. A second method employs singlet carbenemediated hydrogen-carbon insertion of a heterobifunctional, amino-reactive trifluoromethyl-diazirinyl crosslinker. We believe that this new substrate is advantageous to others, because it (i) is atomically flat over large areas and can be prepared in a few hours with standard equipment, (ii) is stable under most conditions, (iii) can be modified to adjust a certain degree of reactivity and hydrophobicity, which allows physical adsorption or covalent crosslinking of the biological specimen, (iv) builds the bridge between semiconductor microfabrication and organic/biological molecular systems, and (v) is accessible to nanopatterning and applications requiring conductive substrates.

Alkanes↗

Characterization of Grafted Poly(ethylene glycol) on Si Wafers Using Scanning Probe Microscopy.

The uniformity and surface topography of grafted poly(ethylene glycol) (PEG) coatings were characterized at the microscale as a function of grafting temperature (grafting density) using scanning probe microscopy. Images of PEG-coated silicon wafers show isolated domains which decrease in size and increase in surface density with increasing grafting temperature. Domain sizes appeared to correlate with the polarity of the solvent used for imaging. Roughness measurements of the PEG layers were obtained. The results are relevant in relation to the biomedically significant ability of PEG coatings to mask surface features such as charge detected via zeta potential measurements. Copyright 1998 Academic Press.

Journal Article↗

High resolution imaging of native biological sample surfaces using scanning probe microscopy.

The possibility of acquiring high resolution topographs using scanning probe microscopes under physiological conditions allows the observation of biomolecules at work. Progress has recently been made in imaging protein-DNA complexes, individual oligomers and protein arrays. Scanning probe microscopes are now tools that complement X-ray crystallography and electron microscopy.

Bacterial Outer Membrane Proteins↗

The role of scanning probe microscopy in drug delivery research.

The success of a drug delivery system is often dependent on the surface properties of the device. These surface properties will determine the complex dynamic interfacial events that occur when the system is introduced into the aqueous environment of a patient. Development of the scanning probe microscopes has provided a number of very powerful new surface analytical techniques that are making a significant contribution to the characterization of drug delivery systems and the interfacial processes that occur when such systems are exposed to aqueous living environments. In this review, we describe the design and attributes of these instruments and discuss the impact of the techniques on a wide range of drug delivery research. The scanning probe microscopes are providing new insights into important problems concerning drug delivery, including the molecular structure of polymeric biomaterial surfaces, the conformation of target biomolecules, the influence of morphology on biodegradation, the adsorption of proteins to synthetic surfaces, and the structure and interactions of colloidal particles. As the whole field of scanning probe microscopy continues to advance, drug delivery research is set to benefit; in the final section of the review, the future potential derived from the ability to characterize new surface properties under aqueous conditions is discussed.

Drug Delivery Systems↗

Scanning probe microscopy with landmark referenced control for direct biological investigations.

We report the successful use of continuous wavelet transforms applied to atomic force microscope data sets for landmark recognition of biological features. The data sets were images of mixed red and white blood cells. Contrast enhancement followed by continuous wavelet transform of the data was used to successfully distinguish erythrocytes from neutrophil and monocyte leukocytes within the mixed cell images. All of the above are spherical objects between 6 and 8 microns in diameter, which demonstrates the ability to sort similar biological objects into distinct classes. The implications for development of on-line scanning probe recognition microscopy are discussed.

Algorithms↗

Temperature and pressure dependence of quercetin-3-O-palmitate interaction with a model phospholipid membrane: film balance and scanning probe microscopy study.

The molecular interaction of quercetin-3-O-palmitate (QP) with dimyristoylphosphatidylcholine (DMPC) has been studied. Film balance measurements of the average molecular area vs QP molar fraction in DMPC/QP mixed monolayers showed that relevant positive deviations from ideality, i.e., a less dense monolayer packing, occurred for a temperature of 10 degrees C, below the critical melting transition temperature of DMPC monolayers T c m approximately equal 20 degrees C), while ideal behavior was observed at 37 degrees C, above this phase transition temperature. The positive deviation observed at low temperatures in the average molecular area increased with the surface pressure. Scanning probe microscopy measurements performed on mixed monolayers transferred on mica showed that the deviations from ideality were connected to the formation of nanometric-scale QP-rich domains. However, the formation of aggregates was observed only for relatively high-QP molar fractions X QP > or = 0.25 at 10 degrees C, while it was not observed at 37 degrees C, i.e., when the ideal mixing was found at the air/water interface. The observed effects are explained in terms of a temperature- and surface pressure-dependent phase-separation process based on the predominance at low temperature and low molecular mobility of QP-QP and DMPC-DMPC aggregation forces, prompting the formation of QP-rich domains embedded in a DMPC-rich matrix. High temperature prompts the QP/DMPC ideal mixing.

Algorithms↗

Detecting H+ in ultrafine ambient aerosol using iron nano-film detectors and scanning probe microscopy.

Recent epidemiological evidence strongly suggests that ambient-particle-associated acidity is more closely correlated with total mortality and hospital admissions for respiratory disease than indices of total particulate mass. In addition, evidence is accumulating to support the hypothesis that the number of ultrafine (d < or = 200 nm) acid particles, rather than ambient mass, is an important determining factor affecting lung injury. Both outdoor and indoor air environments are dominated by nanometer-sized particles. However, no data are currently available on the size distribution or number concentration of acidic ambient ultrafine particles largely because there are no suitable methods for measuring these important quantities. We have developed a method to accomplish these measurements based on the use of iron nano-films for detection of acid droplets. Detectors were prepared by vapor deposition of iron onto 12-mm-diameter glass cover slips. The detectors develop reaction sites when exposed to H2SO4 or NH4HSO4 particles. Exposures to non-acidic particle (NaCl and [(NH4)]2SO4) result in no detectable surface deformations. The nano-films are examined with scanning probe microscopy (SPM) for the enumeration of reaction sites. Until recently, direct visualization of individual objects smaller than 200 nm has been possible only with electron microscopy. The advancement of SPM provides the opportunity to examine the detector surface features with high quality three dimensional imaging.

Aerosols↗

Scanning probe microscopies for high-resolution characterization of electrochemical sensors. Plenary lecture.

A better understanding of tailored electrodes and electrochemical sensors requires a more detailed picture of their surfaces. New scanning probe techniques, such as scanning tunnelling or scanning bioelectrochemical microscopies, offer unique opportunities for high-resolution in situ characterization of tailored electrodebased sensors. Scanning tunnelling microscopy provides valuable information on the topography of pre-treated surfaces, the heterogeneity of composite electrodes, the morphology of electropolymerized films, the packing arrangement of adsorbed monolayers and the microdistribution of immobilized biological components. Scanning bioelectrochemical microscopy is shown to be extremely useful for the mapping of localized biological activity and the monitoring of dynamic biological events. Valuable insights are achieved by correlating the structural features with the preparation/modification conditions and the subsequent sensing performance. Such correlations can facilitate the predictive design of increasingly better sensors.

Biosensing Techniques↗

The scanning probe microscopy of metalloproteins and metalloenzymes.

In recent years, the concept of microscopy and the ability to study processes at a truly molecular level have been revolutionised by the development of a family of instruments based on acquiring data through the scanning of a proximal probe across a surface. Scanning Probe Microscopes (SPMs) enable surface-confined structures to be resolved at ångstrom-resolution, in real time, and under a variety of controllable conditions. Despite initial difficulties, much progress has been in the application of this technology to the high-resolution analysis of biological systems; these have varied from complex cellular systems to molecular biopolymers. Studying the interactions of protein with surfaces has been intrinsic to the development of our understanding of blood coagulation, fibrinolysis, thrombus formation and the synthesis of biocompatible materials. The specific interactions of metalloproteins and enzymes with electrode surfaces remains central to the understanding of the bioelectrochemical processes and to the development of biosensing devices. Though ellipsometry, Raman, microcalorimetry, surface plasmon resonance, and other spectroscopic methods, can provide much information on these interfaces, the acquired data are averaged over a large number of molecular species with a low spatial resolution. Proximal probe methods have much to offer in this regard and have revolutionized our ability to monitor such interactions.

Animals↗

Correction for piezoelectric creep in scanning probe microscopy images using polynomial mapping.

We describe a method for using polynomial mapping to correct scanning probe microscope images for distortion due to piezoelectric creep. Because such distortion varies from image to image, this method can be used when the actual locations of some features within an image are known absolutely, or in a series of images in which the actual locations of some features are known not to vary. While the general case of polynomial mapping of degree N requires the determination of 2(N+ 1)2 matrix elements by regression, we find that by understanding the mechanism by which piezoelectric creep distorts scanning probe microscope images, we can fix most of these coefficients at 0 or 1 a priori, leaving only 2(N+ 1) coefficients to be determined by regression. We describe our implementation of this strategy using the Interactive Data Language (IDL) programming language, and demonstrate our technique on a series of atomic force microscopy (AFM) images of diblock copolymer microdomains. Using our simplified scheme, we are able to reduce the effects of distortion in an AFM image from 5% of the scan width to a single pixel, using only five reference points.

Journal Article↗