PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ORTHODONTIC APPLIANCES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

[The evolution of orthodontic appliances, from Fauchard to Angle].

The present article, makes a summary of the development of orthodontics appliances, describing the several dispositives appeared through the years, and beginning our review with Fauchards band, considered to be the first important orthodontic appliance.

Dental Instruments↗

Learner-control vs. program-control instructional multimedia: a comparison of two interactions when teaching principles of orthodontic appliances.

BACKGROUND: Many studies have compared computer assisted learning (CAL) to more traditional learning formats and have shown CAL to be as effective as or superior to the alternative resources. However, there are only scarce attempts to show which style of CAL leads to the best learning outcomes in orthodontics. AIM: To compare the effectiveness of a learner-control (group A) vs. program-control (group B) multimedia learning environment courseware packages regarding knowledge, understanding and transfer of content when applied to teaching principles of orthodontic appliances to undergraduate students. METHODS: Pre- and post-test assessments of undergraduate dental students (n = 30) who either studied a learner-control multimedia learning environment courseware package (n = 15) or a program-control version (n = 15) on equivalent material of the orthodontic appliances curriculum. Both groups were evaluated by means of multiple-choice questions covering knowledge, understanding and application. A one-way ANOVA was carried out in order to check for statistical difference between the two groups. The P-value was set at 0.05. RESULTS: There was no difference in prior knowledge between both groups at baseline. Although, both groups significantly improved their scores after having studied the course, no significant difference was found between both groups in relation to answers to questions about knowledge, understanding and application. CONCLUSIONS: In this study, the learner-control instructional multimedia program was found to be as effective as the program-control version when teaching principles of the orthodontic appliances to undergraduate students. The focus needs to be on improving the value of CAL. Comparative evaluations of how different CAL approaches compare with or complement one another are certainly needed.

Comprehension↗

Effects of fixed-appliance orthodontic treatment on DMF indices.

An investigation was conducted to clarify the relationship between orthodontic treatment and caries incidence. DMF indices from 308 orthodontically treated and 305 untreated naval recruits were compared. Contrary to expectations, there was no evidence that orthodontic treatment increases caries experience. Orthodontically treated subjects had significantly fewer diseased surfaces--a difference averaging one less diseased surface per patient. Treatment status did not generally affect the number of filled surfaces. Treated subjects had more missing teeth if first premolars were considered, but untreated subjects had more missing teeth if first premolars were not considered. No significant correlation was found between caries incidence and duration of orthodontic treatment. The epidemiologic basis and significance of these findings are discussed.

Adolescent↗

Ion release from orthodontic appliances.

OBJECTIVE: The microbiological and enzymatic characteristics of the oral cavity would seem to provide a suitable environment for the corrosion of metals. We assayed the release of metal ions from one orthodontic appliance which included two 304 and 316 steel molar bands, ten 316 steel brackets, one nickel-titanium archwire and a brazing alloy to connect the elements of molar bands and brackets. METHODS: The orthodontic appliance was dipped in both inorganic (pH 3.5-6.5) and organic acid solutions (w/v 1% each of tartaric, citric and ascorbic acid at pH 2.2 or 1.5% each of lactic and acetic acid at pH 2.5). The release of nickel (Ni), chromium (Cr), copper (Cu), silver (Ag) and palladium (Pd) was determined using an atomic absorption spectrophotometer Varian AA 10. RESULTS: The release of Ni, Cr and Cu was markedly less at pH 6.5 than at pH 3.5 at all time points in acid solution. Daily release/single appliance after the first day decreased. Contrary to expectations, appliances immersed in organic acid solutions at pH 2.2 or 2.5 after 28 days generally released an amount of ions similar to that observed in inorganic acid solution at pH 3.5, with the exception of Cu. Release of silver and palladium, two metals present in the brazing alloy, proved to be very low (approximately 0.2 microgram after 28 days). CONCLUSIONS: The daily release of Ni, Cu and Cr by an orthodontic appliance in acid pH, particularly favourable to corrosion, was well below that ingested with a normal daily diet. It is therefore concluded that the quantities of metal ions released in our experimental conditions should not be cause for concern in utilising the appliance.

Chromium↗

Assessing treatment effectiveness of removable and fixed orthodontic appliances with the occlusal index.

Orthodontists from different backgrounds may have different opinions about removable and fixed orthodontic appliances, but there have been few objective comparisons of their relative treatment effectiveness. It is the purpose of the present study to analyze objectively the effectiveness of these two types of appliances. Eighty cases involving patients who had been treated with removable appliances and 67 cases of patients treated with fixed appliances were studied with respect to the Occlusal Index (OI). Scores indicating severity of malocclusion were obtained from pretreatment and posttreatment study casts. The effectiveness of the fixed appliance (represented by average reduction in OI score) was much greater than that of the removable appliance. The result of treatment with the fixed appliance was also found to be much better than that of the treatment with the removable appliance (indicated by the much lower posttreatment OI score in the fixed-appliance cases). The Occlusal Index was designed to measure features of basic malocclusion and is not a very sensitive index for assessing symptoms of a developing malocclusion. The fact that both the treatment effectiveness and the treatment results of the removable appliance were found to be inferior to those of the fixed appliance may indicate that the removable appliance has been used largely to correct "symptoms" rather than basic malocclusion.

Adolescent↗

Later orthodontic appliance reactivation stimulates immediate appearance of osteoclasts and linear tooth movement.

BACKGROUND: Delays in the appearance of osteoclasts at compression sites occur after orthodontic appliance reactivation, when this is done during both the period of osteoclast recruitment and the peak expansion in the osteoclast population. This experiment examines osteoclasts and tooth movement in alveolar bone after appliance reactivation coinciding with alveolar bone formation and the time when reactivation osteoclasts first appear (ie, 10 days after initial appliance activation). METHODS: Bilateral orthodontic appliances were activated to mesially tip maxillary molars with 40 cN in 144 rats. After 10 days, all rats were randomized into two groups of 72. Group I had appliances reactivated in precisely the same manner as the first activation. Group II had appliances sham-reactivated. Nine to 12 rats were then sacrificed at 1, 3, 5, 7, 10, and 14 days in both groups (eg, day 1 represents an interval of 11 days after the first appliance activation and 1 day after either sham or real reactivation). Orthodontic movement was measured cephalometrically; changes in osteoclasts and root resorption were assessed at both compression and tension sites histomorphometrically. RESULTS: Teeth in the reactivated group (Group I) displayed linear tooth movement (62.6 micrometers/day), and 0.9 mm tooth movement by day 10. Significant increases in osteoclast numbers, osteoclast surface percentage, and surface per individual osteoclast were evident in these animals by 1 day postreactivation (P <.01). Significant treatment-related increases in root resorption were not evident at compression sites at any time. CONCLUSIONS: These findings indicate that, after appliance reactivation during the time when reactivation osteoclasts appear, a second cohort of osteoclasts can be recruited immediately, along with immediate and substantial tooth movement and no greater risk of root resorption.

Alveolar Process↗

Lingual orthodontic appliances: invisible braces.

Lingual orthodontics is a relatively new method of delivering orthodontic treatment. These appliances may be used on any patient, but they have a special application for that small group of adult patients who need orthodontic treatment but refuse to accept the appearance of conventional appliances. The technique is difficult to manage and should be used only by experienced orthodontists. Although the patients may experience difficulties, these are usually adequately compensated for by the improved aesthetics.

Equipment Design↗

Increase of the vertical occlusal dimension by means of a removable orthodontic appliance and its effect on craniocervical relationships and position of the cervical spine in children.

The aim of this study was to determine the effect of the increase in the occlusal vertical dimension by means of an orthodontic appliance on craniocervical relationships and position of the cervical spine. Thirty children presenting malocclusion were divided into two groups of 15 (a study and a control group). Those in the study group wore an orthodontic appliance to correct cross-bite. The children in the control group had no treatment during the experimental period. Two lateral craniocervical radiographs were taken for each child. The first one was taken in the intercuspal position in both groups. The second radiograph was taken of the study group after four months of wearing the appliance and also of the control group after four months. Cephalometric analysis in the study group showed a significant forward cervical spine position. There were no significant changes in the control group. The changes found in the study group suggest that when there are signs and symptoms of cervical dysfunction in children undergoing long-term orthodontic treatment, it is necessary to make an evaluation of the cervical column position after the insertion of any orthodontic appliance which increases the occlusal vertical dimension.

Case-Control Studies↗

Palatal finger springs in removable orthodontic appliances--an in vitro study.

Palatal finger springs are often used in removable orthodontic appliances to tip teeth in a mesiodistal direction. There is general consensus that a force of 30-50 g is required to tip a single-rooted tooth, with an activation of about 3 mm for a spring with a load/deflection rate (LDR) of 15 g/mm. The purpose of this report is to establish the magnitude of forces for finger springs made from different types of wires (i.e. those from different manufacturers and of different diameters and lengths). The findings were that springs made from ordinary 18/8 stainless steel wire showed a lower LDR than previously reported. The 18/9 stainless steel springs gave yet a lower LDR. Definite specifications are given for forming springs. For example, a Unitek 0.51 x 17 mm spring can be used when the traditional activation of 2-4 mm is applied, but should increased activation be required (advocated in this report), the spring length would have to be increased to 20 mm to keep the force within the specified range.

Dental Stress Analysis↗

Biodegradation of orthodontic appliances. Part I. Biodegradation of nickel and chromium in vitro.

The purpose of this study is to compare in vitro the corrosion rate of a standard orthodontic appliance consisting of bands, brackets and either stainless steel or nickel-titanium arch wires. The corrosion products analyzed were nickel and chromium. Evaluation was conducted with the appliances immersed for 4 weeks in a prepared artificial saliva medium at 37 degrees C. Ten identical sets were used, each simulating a complete orthodontic appliance used on a maxillary arch with a full complement of teeth. Five sets were ligated to stainless steel arch wires, and the other five sets were ligated to nickel-titanium arch wires. Nickel and chromium release was quantified with the use of a flameless atomic absorption spectrophotometry. The analysis of variance was used to determine if differences existed between the nickel and chromium release according to arch wire type, as well as with time (days 1, 7, 14, 21, and 28). The results indicate that (1) orthodontic appliances release measurable amounts of nickel and chromium when placed in an artificial saliva medium. (2) The nickel release reaches a maximum after approximately 1 week, then the rate of release diminishes with time. On the other hand, chromium release increases during the first 2 weeks and levels off during the subsequent 2 weeks. (3) The release rates of nickel or chromium from stainless steel and nickel-titanium arch wires are not significantly different. (4) For both arch wire types, the release for nickel averaged 37 times greater than that for chromium. How much of these corrosive products are actually absorbed by patients still needs to be determined.

Alloys↗

[Clinical examination of the effect of the "Corega Junior" cleaning tablets for removable orthodontic appliances].

According to the authors' macroscopic and microbiological examinations Corega Junior prevents plaque formation on the orthodontic appliances and the establishment and multiplication of microorganisms and therefore has a favourable effect to the oral flora and last but not least to the general state of health of the patients. The usage of the Corega Junior cleaning tablets incites young people for the regular use of orthodontic appliances and indirectly for mouth care.

Adolescent↗

Clinical and microbiologic changes after removal of orthodontic appliances.

The goal of this study was to evaluate the clinical and microbiological factors associated with orthodontic appliances during an episode of gingival inflammation and the impact of appliance removal on periodontal health. This prospective study included 10 patients, aged 12 to 20 years, with clinical signs of gingival inflammation at the final phase of orthodontic treatment (appliance removal). Plaque index, gingival index, and probing depth were evaluated, and microbiological samples were collected from teeth 16, 11, and 26 at 2 times: during the gingival inflammation (baseline) and 30 days after the removal of the appliance and professional prophylaxis. Polymerase chain reaction analysis was used to detect Porphyromonas gingivalis, Bacteroides forsythus, Actinobacillus actinomycetemcomitans, Prevotella intermedia, and Prevotella nigrescens. A statistically significant improvement of the plaque and gingival indexes was seen, as well as a reduction in probing depth (P <.05). Periodontal pathogens were associated with gingival inflammation during orthodontic treatment. The improvement in periodontal health at 30 days was concomitant with a reduction of sites positive for A. actinomycetemcomitans and B. forsythus (P <.05). Periodontal pathogens associated with gingival inflammation during orthodontic treatment can be significantly reduced by orthodontic appliance removal and professional prophylaxis.

Adolescent↗

Orthodontic appliances in relation to nickel hypersensitivity. A review.

Nickel hypersensitivity is an increasing problem in adolescents, especially in girls, with a prevalence of up to 30%. The presence of nickel in orthodontic appliances and the possibility of causing nickel hypersensitivity has been discussed in case reports. A review of the literature concerning nickel hypersensitivity in relation to orthodontic appliances has shown that the risk is very low for patients who are not nickel hypersensitive at the start of the treatment. A patient who is already nickel hypersensitive at the start of orthodontic treatment may in rare cases show adverse reactions induced by the appliance. The slow long-term release of nickel from orthodontic appliances may induce tolerance to nickel in individuals who are not hypersensitive at the start of orthodontic treatment.

Adolescent↗