PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “SLs”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Lung volumes during sustained microgravity on Spacelab SLS-1.

Gravity is known to influence the mechanical behavior of the lung and chest wall. However, the effect of sustained microgravity (mu G) on lung volumes has not been reported. Pulmonary function tests were performed by four subjects before, during, and after 9 days of mu G exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box-and-flowmeter system and a respiratory mass spectrometer. Measurements included functional residual capacity (FRC), expiratory reserve volume (ERV), residual volume (RV), inspiratory and expiratory vital capacities (IVC and EVC), and tidal volume (VT). Total lung capacity (TLC) was derived from the measured EVC and RV values. With preflight standing values as a comparison, FRC was significantly reduced by 15% (approximately 500 ml) in mu G and 32% in the supine posture. ERV was reduced by 10-20% in mu G and decreased by 64% in the supine posture. RV was significantly reduced by 18% (310 ml) in mu G but did not significantly change in the supine posture compared with standing. IVC and EVC were slightly reduced during the first 24 h of mu G but returned to 1-G standing values within 72 h of mu G exposure. IVC and EVC in the supine posture were significantly reduced by 12% compared with standing. During mu G, VT decreased by 15% (approximately 90 ml), but supine VT was unchanged compared with preflight standing values. TLC decreased by approximately 8% during mu G and in the supine posture compared with preflight standing. The reductions in FRC, ERV, and RV during mu G are probably due to the cranial shift of the diaphragm, an increase in intrathoracic blood volume, and more uniform alveolar expansion.

Adult↗

Ventilatory inhomogeneity determined from multiple-breath washouts during sustained microgravity on Spacelab SLS-1.

We used multiple-breath N2 washouts (MBNW) to study the inhomogeneity of ventilation in four normal humans (mean age 42.5 yr) before, during, and after 9 days of exposure to microgravity on Spacelab Life Sciences-1. Subjects performed 20-breath MBNW at tidal volumes of approximately 700 ml and 12-breath MBNW at tidal volumes of approximately 1,250 ml. Six indexes of ventilatory inhomogeneity were derived from data from 1) distribution of specific ventilation (SV) from mixed-expired and 2) end-tidal N2, 3) change of slope of N2 washout (semilog plot) with time, 4) change of slope of normalized phase III of successive breaths, 5) anatomic dead space, and 6) Bohr dead space. Significant ventilatory inhomogeneity was seen in the standing position at normal gravity (1 G). When we compared standing 1 G with microgravity, the distributions of SV became slightly narrower, but the difference was not significant. Also, there were no significant changes in the change of slope of the N2 washout, change of normalized phase III slopes, or the anatomic and Bohr dead spaces. By contrast, transition from the standing to supine position in 1 G resulted in significantly broader distributions of SV (P < 0.05) and significantly greater changes in the changes in slope of the N2 washouts (P < 0.001), indicating more ventilatory inhomogeneity in that posture. Thus these techniques can detect relatively small changes in ventilatory inhomogeneity. We conclude that the primary determinants of ventilatory inhomogeneity during tidal breathing in the upright posture are not gravitational in origin.

Adult↗

Effect of SLS-2 spaceflight on immunologic parameters of rats.

During the Spacelab Life Sciences-2 mission, rats were dissected in space and biosamples were returned to Earth for analysis. Immunologic studies addressed the kinetics of T lymphocyte proliferative responses, cytotoxic activity of natural killer cells, and cytokine production. Experiments were performed by using spleen and bone marrow of rats dissected before flight, during flight, immediately after landing of the space shuttle (R + 0), or 14 days after landing (R + 14), as well as those of respective control animals. Each group consisted of five male Sprague-Dawley rats. It was demonstrated that T lymphocyte activity of rats dissected in flight was significantly decreased compared with the controls. This was observed during 48-, 72-, and 96-h cultivation and stimulation with the following mitogenic stimuli: concanavalin A (Con A; 0.1, 1.0, and 10.0 mg/ml), phytohemagglutinin (PHA; 2.5 mg/ml), and interleukin-2 (IL-2; 1 U/ml). The cell proliferation rate in rats dissected immediately after landing did not decrease, whereas that in rats dissected at R + 14 increased. The activity of spleen natural killer cells was reduced in response to 51Cr-labeled target cells during flight (YAC-1 and K-562) and after flight (YAC-1). At R + 14, their activity returned to normal. Another technique employed to measure natural cytotoxicity, using [3H]uridine-labeled target cells and ribonuclease, did not reveal any differences between control and experimental groups. In bone marrow, the activity of natural killer cells did not vary significantly. The production of IL-1, IL-2, tumor necrosis factor (TNF)-alpha, and TNF-beta in spleen cell cultures of the flight rats was reduced. At R + 0, IL-1 and TNF-beta levels remained lowered, whereas TNF-alpha was increased. At R + 0, interferon-alpha and interferon-gamma levels were diminished. In summary, cell-mediated immunity in rats was significantly suppressed during flight. The time course variation of immune parameters after flight suggests that the changes may truly indicate a response of the immune system to spaceflight conditions that could increase over time.

Animals↗

Forced expirations and maximum expiratory flow-volume curves during sustained microgravity on SLS-1.

Gravity is known to influence the mechanical behavior of the lung and chest wall. However, the effect of sustained microgravity (microG) on forced expirations has not previously been reported. Tests were carried out by four subjects in both the standing and supine postures during each of seven preflight and four postflight data-collection sessions and four times during the 9 days of microG exposure on Spacelab Life Sciences-1. Compared with preflight standing values, peak expiratory flow rate (PEFR) was significantly reduced by 12.5% on flight day 2 (FD2), 11.6% on FD4, and 5.0% on FD5 but returned to standing values by FD9. The supine posture caused a 9% reduction in PEFR. Forced vital capacity and forced expired volume in 1 s were slightly reduced (approximately 3-4%) on FD2 but returned to preflight standing values on FD4 and FD5, and by FD9 both values were slightly but significantly greater than standing values. Forced vital capacity and forced expiratory volume in 1 s were both reduced in the supine posture (approximately 8-10%). Forced expiratory flows at 50% and between 25 and 75% of vital capacity did not change during microG but were reduced in the supine posture. Analysis of the maximum expiratory flow-volume curve showed that microG caused no consistent change in the curve configuration when individual in-flight days were compared with preflight standing curves, although two subjects did show a slight reduction in flows at low lung volumes from FD2 to FD9. The interpretation of the lack of change in curve configuration must be made cautiously because the lung volumes varied from day to day in flight. Therefore, the flows at absolute lung volumes in microG and preflight standing are not being compared. The supine curves showed a subtle but consistent reduction in flows at low lung volumes. The mechanism responsible for the reduction in PEFR is not clear. It could be due to a lack of physical stabilization when performing the maneuver in the absence of gravity or a transient reduction in respiratory muscle strength.

Adult↗

Tactile influences on astronaut visual spatial orientation: human neurovestibular studies on SLS-2.

Human spatial orientation in spaceflight is initially disturbed by the absence of usable graviceptor information from the otolithic organs. Experiments measuring astronaut visually induced motion (vection) strength on various flight days during the first 10 days of the Spacelab Life Sciences-2 mission demonstrated two new phenomena in addition to confirming the initial increased weighting of visual and localized tactile cues. The reliance on tactile and visual noninertial cues apparently declined after a week in space, as the crew became able to utilize their internal reference frame. Subjects also showed that even nondirectional tactile cues served as a direction anchor and inhibited visually induced roll sensation relative to a new loosely tethered test condition. Individual perceptual styles were again revealed among the four astronauts tested. The readaptation to 1 G similarly shows a period of reinterpretation of inertial and visual cues to spatial orientation. The results are discussed in terms of an internal-model representation of body orientation, with time-varying weights applied to extrinsic and intrinsic signals.

Adult↗

Effect of spaceflight on ability to sense and control roll tilt: human neurovestibular studies on SLS-2.

To measure adaptive changes in the ability to sense tilt after spaceflight, we measured the ability of four astronauts to control roll tilt in the presence of a pseudorandom motion disturbance before and after a 14-day Spacelab mission. The subjects were tested 1) in the dark, 2) with an independent sum-of-sines visual display, and 3) by using a control condition in which the visual cues confirmed the motion cues (counterrotating). The two subjects tested on the landing day exhibited significant decrements (P < 0.05) in their ability to control roll tilt in the dark, whereas no significant performance decrements were observed in the control condition. The absence of changes in the control condition suggests that changes in the neuromuscular component of the task and postflight fatigue were not major factors contributing to the observed performance decrement in the dark. These findings indicate an adaptive change in the way the nervous system interprets tilt cues. Readaptation of all responses appeared to be rapid, with a return to preflight values within 1-2 days after landing.

Adaptation, Physiological↗

Perceptual responses to linear acceleration after spaceflight: human neurovestibular studies on SLS-2.

Perceptual responses of four astronauts were measured before and after a 14-day Spacelab Life Sciences-2 mission during interaural (y-axis) and rostrocaudal (z-axis) linear acceleration to measure adaptive changes in perceptual responses to inertial cues. In one test, subjects used a joystick to null a pseudorandom velocity disturbance. Postflight, two of three subjects showed a significantly enhanced ability to null linear self-motion in the y-axis and z-axis orientations. In another test, the subjects used a joystick to indicate their direction of motion during a series of low-acceleration steps. The postflight responses of three of the four subjects showed a significant increase in the response latency for both y-axis and z-axis orientations. In a third test, subjects were asked to track a stationary but unseen target with their eyes while they translated linearly in the dark. No significant changes were observed in the postflight responses. The observed changes, when present, may be due to a reinterpretation of inertial cues that are functionally adaptive for the microgravity environment but are not optimal for responses on Earth.

Acceleration↗

Horizontal angular VOR changes in orbital and parabolic flight: human neurovestibular studies on SLS-2.

Further evidence was found for adaptive changes in the vestibular "velocity storage" (VS) component of the vestibuloocular reflex in four shuttle astronauts tested in parabolic flight and before, during, and after a 14-day mission. Nystagmus was recorded during and after 1 min of 120 degrees/s rotation. Gains and time constants were determined by computer analysis. Responses correlated with experience. Two subjects were making their first spaceflight. In parabolic flight, their time constants shortened to an average of 60% of 1 G values, presumably because unfamiliar otolith cues reduced VS. However, after 4-10 days in orbit, their time constants were similar or greater than those preflight, indicating VS recovery. The other two subjects had previously flown in space. Their time constants shortened in orbit to an average of 69% of 1 G values, indicating a persisting reduction of VS. This correlation with spaceflight experience has been seen in 9 of 11 subjects on 3 missions. Head pitch did not significantly "dump" nystagmus as it does on Earth.

Adult↗

Horizontal angular VOR, nystagmus dumping, and sensation duration in spacelab SLS-1 crewmembers.

In 1G, the apparent time constant (Td) of postrotatory SPV decay with the head tilted face down is 55% of that with head erect (Te). This phenomenon is called "nystagmus dumping" and has been attributed to G effects on VOR velocity storage. Similarly, postrotatory sensation duration with head tilted (Dd) is 32% of that when head erect (De). In parabolic flight, Te and De are 70% of 1-G values, but a pitch back dumping movement produces no further change. Te, Td, and Dd have not previously been measured in orbital flight. VOR and sensation duration was tested in 4 crewmembers in 4 preflight, 1 inflight (days 4 or 5) and 4 post flight sessions. Bitemporal EOG was recorded with eyes open in darkness. Instructions were to "gaze straight ahead," and indicate when "rotation sensation disappears or becomes ambiguous". Subjects were rotated CW and CCW head erect for 1 min at 120 degrees/s, stopped, and EOG was recorded for another 1 min. This procedure was then used to study dumping, except that immediately after chair stop, subjects pitched their head forward 90 degrees. SPV was calculated using order statistic filtering, and dropouts removed using an iterative model fitting method. Te and Td were determined by logarithmic linear regression of mean SPV for each subject. In orbit, 90 degrees pitch movement produced rapid subjective dumping, but not nystagmus dumping. Dd was noticeably shorter ("almost instantaneous") compared to preflight Dd. Te and Td in orbit were similar to preflight Te for 3/4 subjects (rather than to preflight Td as expected). No consistent VOR gain changes were seen in orbit. Although Te is known to decrease acutely in parabolic flight, a longer time constant was measured in 3/4 subjects after 4-5 days adaptation to weightlessness, suggesting a return of angular velocity storage.

Adult↗