PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Sample pretreatment”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Sample pretreatment method for the determination of polychlorinated biphenyls in bird livers using ultrasonic extraction followed by headspace solid-phase microextraction and gas chromatography-mass spectrometry.

A simple and reliable sample methodology based on simultaneous ultrasonic extraction, sulfuric acid clean-up and headspace solid-phase microextraction (SPME)-gas chromatography-mass spectrometry has been developed as an advantageous analytical tool for the determination of seven polychlorinated biphenyl congeners in bird livers at low levels. The influence of several parameters on the efficiency of the proposed method was systematically investigated. The clean-up efficiency of sulfuric acid treatment was tested and compared with those of column chromatography (Flosiril, silica gel and alumina) and solid-phase extraction (SPE) (Supelclean ENVI-Carb cartridge) procedures. The use of sulfuric acid in the clean-up step prior to headspace solid-phase microextraction analysis allows the removal of interfering matrix compounds present in the liver extracts that would otherwise cause severe ionization suppression of the polychlorinated biphenyls (PCBs) during the ionization process. The optimized method had good linearity (R2>0.99) over the range studied (5-500 ng/g wet weight) and showed satisfactory level of precision, with RSD values lower than 10.6%. The obtained relative recoveries ranged between 63 and 94%. The limits of detection (0.06-0.63 ng/g wet weight) were low enough to check for harmful levels of polychlorinated biphenyls in biological samples, and were well below most of the restrictive limits established by European Union regulations. The method was found to be reliable under the operational conditions proposed and was applied successfully to the analysis of individual polychlorinated biphenyls in liver tissues. The results obtained from five bird species from Greece revealed the presence of the target compounds in all samples analyzed, at levels ranging between 0.54 and 39.45 ng/g wet weight.

Animals↗

Effect of sample pretreatments on the storability of ground melon 'egusi'-Colocynthis citrillus L.

In the maintenance of shelf-stability, nutritional and organoleptic properties of ground melon 'egusi'-Colocynthis citrullus L., vacuum-packaged samples were found to be better than unpackaged samples and samples treated with 0.2% butylated hydroxyanisole (BHA) and 0.02% BHA + 0.045% sodium metabisulphite. After 56 days at 35 degrees C, stored samples showed significant differences (P < or = 0.01) in chemical composition peroxide value (PV), fungal counts and organoleptic attributes. Lipid oxidation and, to a lesser extent, fungal deterioration were responsible for the spoilage of stored ground melon kernel. The dominant fungal flora isolated from stored samples were of the genera Penicillium, Botryodiplodia, Rhizopus and Aspergillus.

Butylated Hydroxyanisole↗

Determination of levetiracetam in human plasma with minimal sample pretreatment.

We here present a method for the routine quantification of the novel antiepileptic drug levetiracetam in human serum by HPLC-UV. The procedure is very easy, quick, inexpensive and rugged. The sample preparation consists only in the precipitation of serum proteins by perchloric acid and extraction of unpolar components by cyclohexane. The aqueous phase containing the analyte levetiracetam is injected onto a porous graphitic carbon analytical HPLC-column and separated by gradient elution with diluted phosphoric acid/acetonitrile. Detection is carried out at a wavelength of 205 nm. The calibration function is linear in the range of 1-75 microg/ml. The detection limit is 0.1 microg/ml. Using four quality control sample concentrations, the inter-day relative standard deviations (R.S.D.) are lower than 3% and the accuracies are better than 6%. The respective inter-day values are: R.S.D. < 4% and accuracies better than 2%. Frequently co-administered antiepileptic drugs do not interfere with the assay. The method has been successfully applied to patient samples.

Anticonvulsants↗

HPLC assay of conjugated bile acids in human fluids using on-line sample pretreatment on a standard isocratic chromatograph.

A rapid and simple on-line purification procedure was developed for determining the conjugated bile acids in human fluids by high-performance liquid chromatography (HPLC). Biological samples were diluted and directly injected without further treatment onto a pre-column dry-packed with 40-microns octadecylsilica and installed at the injector loop position. After washing the pre-column with 40% methanol in acetate buffer and then with water, the retained compounds were back-flushed by the mobile phase onto the analytical column during the normal course of chromatography. The method was found to be accurate and reproducible. The levels of conjugated bile acids in serum, duodenal bile and gastric juice from patients with hepatobiliary and gastric diseases were determined by on-line pre-column clean-up and reversed-phase HPLC.

Bile↗

Determination of deramciclane and N-desmethylderamciclane in human plasma by liquid chromatography-tandem mass spectrometry using off-line robotic sample pretreatment.

A rapid and highly sensitive LC-MS-MS method using deuterium-labelled internal standards was developed and evaluated for the simultaneous determination of deramciclane and its pharmacologically active metabolite (N-desmethylderamciclane). The sample preparation based on liquid-liquid extraction was carried out with an off-line robotic system. Evaluation of this analytical method shows that samples can be assayed with acceptable accuracy and precision in the 0.1 to 50 ng/ml concentration range for both compounds. The method was applied for the quantitative determination of deramciclane and its metabolite in human plasma samples during a food interaction pharmacokinetic study.

Calibration↗

Determination of aflatoxin M1 using a dialysis-based immunoaffinity sample pretreatment system coupled on-line to liquid chromatography. Reusable immunoaffinity columns.

A liquid chromatographic column-switching system containing a dialysis unit and an anti-aflatoxin immunoaffinity precolumn (immuno precolumn) is described for the automated determination of aflatoxin M1 in milk samples. Both a flat membrane dialysis unit working according to the flowing donor-flowing acceptor principle and a laboratory made hollow-fibre dialysis unit working according to the stagnant donor-flowing acceptor principle were evaluated. The hollow-fibre unit is superior with respect to repeatability (3% relative standard deviation) and detection limit (10 ng/l for aflatoxin M1 in milk), in spite of the fact that the overall recovery is only 6%. Interfering compounds, which would destroy the activity of the immuno precolumn, are efficiently removed from the system by the dialysis step; a single immuno precolumn can then be used for over 70 milk analyses. No decrease in the performance of either the immuno precolumn or the hollow-fibre dialysis unit is observed.

Aflatoxin M1↗

Rapid direct determination of lead in evaporated milk by anodic stripping voltammetry without sample pretreatment.

The method presented describes the direct determination of lead in evaporated milk in which the milk ashing step prior to analysis is eliminated. Digital instrument readout units are microgram Pb/mL milk. Total analysis time after instrument calibration is less than 3 min per sample. Range of the method is 0.05-1.0 ppm lead in milk, and precision of the method expressed by relative standard deviation of duplicate pairs ranged from 30% at 0.1 micrograms/mL to 3% at 1.0 micrograms/mL of lead in milk. The method compares favorably with the AOAC official first action anodic stripping voltammetric method (25.074). In addition, the method appears to work equally well for skim evaporated milk, sweetened condensed milk, and nonfat powdered dry milk when the latter two are reconstituted with water according to product label instructions. Recovery and interference studies are presented.

Animals↗

[Fundamental study of in vitro colony forming unit-erythroid assay--reproducibility and sample pretreatment].

The in vitro assay of colony forming unit-erythroid (CFU-E) colony is a direct and most reliable method to evaluate a biological activity of erythropoietin (EPO). In general, two kinds of cells are employed in this assay system as an effector cell, e.g. bone marrow cell and fetal mouse liver cell, and the latter cell has more sensitivity for EPO. In this paper, a fundamental methodological process in vitro CFU-E colony formation using a fetal mouse liver cell was described in detail and sensitivity for EPO as well as reproducibility of formed colony count were checked up. In addition, an inhibitory effect was indicated in plasma, even though sampled from a healthy volunteer and it was confirmed to be eliminated sufficiently by simple pretreatment with acidification combined with boiling.

Animals↗

Simultaneous measurement of L-dopa, its metabolites and carbidopa in plasma of parkinsonian patients by improved sample pretreatment and high-performance liquid chromatographic determination.

A procedure is described for the determination of L-3,4-dihydroxyphenylalanine (L-DOPA), its metabolites and carbidopa (CD) in plasma of Parkinsonian patients by high-performance liquid chromatography with dual working-electrode coulometric electrochemical detection. An efficient sample preparation scheme is presented for the isolation of L-DOPA, its metabolites and the catecholamines from the same plasma aliquot. After a simple deproteinization with methanol containing 2% of 0.5 M perchloric acid and evaporation of the solvent, L-DOPA, its metabolites and CD were separated with a 5-micron Nucleosil C18 column. Catecholamines were extracted from the supernatant of the deproteinized plasma by ion exchange on small columns and adsorption on alumina. Recoveries were close to 100% for L-DOPA, its metabolites and CD and 70% for catecholamines. The use of the same mobile phase for the concurrent assay of L-DOPA, its metabolites and catecholamines considerably increased the throughput of samples in the chromatographic system. The dual-electrode coulometric detector afforded peak identification by comparing current ratios. Monitoring of data from patients under L-DOPA therapy is reported.

Carbidopa↗

Combination of supported liquid membrane and solid-phase extraction for sample pretreatment of triazine herbicides in juice prior to capillary electrophoresis determination.

A possibility of a combination of supported liquid membrane (SLM) and solid-phase extraction (SPE) for the determination of atrazine at microgram level in different type of fruit juices is presented. In comparison to SPE extraction from juice samples, the application of SLM-SPE enrichment provides much cleaner extracts and the possibility of lowering the limit of detection as low as 30 microg/l. However, it was also shown that by appropriate manipulation of SLM extraction conditions mainly flow-rate of donor phase and volume ratio between donor and acceptor phase, the level of detection can be further decreased to 10 microg/l. The results suggest that the application of SLM extraction prior to SPE is an alternative method for atrazine enrichment from complicated liquid matrices and could be used as routine method for the clean-up of such samples.

Atrazine↗

Automated determination of levodopa and carbidopa in plasma by high-performance liquid chromatography-electrochemical detection using an on-line flow injection analysis sample pretreatment unit.

An automated analytical procedure is described for the parallel determination of L-3,4-dihydroxyphenylalanine (levodopa, L-dopa, LD) and the analogous hydrazine compound carbidopa (CD) in dog plasma by ion-pair high-performance liquid chromatography with electrochemical detection (HPLC-ED). After deproteinization of the plasma samples with perchloric acid the catecholamines were extracted from the supernatant by adsorption on a small column filled with alumina. The extraction and redissolution were automatically performed in a flow injection analysis unit (FIA) coupled to the HPLC system. The performance of the whole system was tested on dog plasma samples including specimens taken after oral administration of the anti-Parkinsonism drug Duellin, which is a combination tablet of levodopa and carbidopa.

Animals↗

On the perspectives of capillary electrophoresis modes for the determination of morphine in human plasma without sample pretreatment.

Screening and confirmation of drugs of abuse in body fluids are important for the medicinal treatment and form the legal basis of court judgments. A fast and precise identification of toxic substances is necessary. Morphine was determined in human plasma by capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MECC) using sample stacking mode. The electrophoretic separation was performed in an uncoated fused-silica capillary, 70 cm long to the detector, with an additional 10 cm to the cathode (75 microm i.d. and 360 microm o.d.). The UV absorbance detection was set at 190 nm. The electrophoretic buffers were prepared from 60 to 300 mm disodium tetraborate decahydrate, pH 10.5. Sodium dodecyl sulfate was added to the final solution in a concentration of 60 mm for MECC. All electrophoretic separations were carried out at 10 kV and the capillary temperature was ambient (25 degrees C). A linear calibration graph was obtained in the concentration range studied (50-5000 ng/mL). Several samples of drug-free plasma were checked for potential endogenous interference and the results showed no interference from the endogenous components, which co-migrated with morphine. As little as 50 ng/mL of morphine could be successfully analyzed by MECC in the concentration mode with acceptable precision. It is possible to determine morphine directly in plasma at therapeutic concentrations.

Calibration↗

Iminodiacetic acid derivatized porous silicon as a matrix support for sample pretreatment and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry analysis.

Iminodiacetic acid (IDA)-1,2-epoxy-9-decene has been synthesized and covalently linked to the surface of porous silicon wafer through a photochemical reaction. The negatively charged carboxylic acid groups on the porous silicon wafer are capable of binding oppositely charged species from sample solutions through electrostatic interactions. This allows the removal of contaminants prior to matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) by simply washing the porous silicon surface. The carboxylic acid end groups on porous silicon can be used to selectively bind and concentrate target species in sample solutions. Furthermore, Fe(3+)-IDA-derivatized porous silicon was prepared to specifically and effectively concentrate phosphopeptides from the tryptic digests of phosphoproteins, followed by MALDI-MS analysis.

Caseins↗

On-probe sample pretreatment for the detection of proteins above 15 KDa from whole cell bacteria by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

A rapid methodology is described for the enhancement of the signal-to-base-line (S/B) ratio of high molecular weight protein signals from whole cell bacteria analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). The procedure involves depositing growing bacteria colonies from culture dishes directly onto the MALDI probe followed by treatment of the sample spot with a 2 microL aliquot of 40% ethanol prior to the addition of a ferulic acid matrix solution (12.5 mg dissolved in 17% formic acid/33% acetonitrile/50% H(2)O). Protein signals of more than 20 kDa were routinely produced from both Gram positive and Gram negative bacteria prepared in this manner. Moreover, a substantial number of intense protein signals were also produced in the more 'conventional' fingerprint region extending from 4 to 20 kDa. This approach is rapid, easy to implement into existing methodologies, and does not require any special hardware.

Bacterial Proteins↗

Multicenter evaluation of a homogeneous assay for HDL-cholesterol without sample pretreatment.

We evaluated a new homogeneous assay for the measurement of HDL-cholesterol (HDL-C) in six European laboratories. The assay includes two reagents and is applicable to most autoanalyzers, which allows full automation. The total CVs of the new method ranged between 1.3% and 6.7%. Thereby determined HDL-C values were in good agreement with those obtained by precipitation with phosphotungstic acid/MgCl2 or by a combination of ultracentrifugation and precipitation (0.956 < r < 0.994). The assay was linear up to at least 1500 mg/L HDL-C. Hemoglobin did not interfere, whereas icteric samples with bilirubin > 100 mg/L showed discrepancies between the homogeneous and the precipitation assay. Lipemia up to total triglyceride concentrations of 8000 mg/L did not interfere with the homogeneous HDL-C assay. The homogeneous HDL-C assay was easy to handle and produced similar results in all laboratories participating in this study. This method will significantly facilitate the screening of individuals at increased risk for cardiovascular disease.

Artifacts↗

Determination of copper and arsenic in refined beet sugar by stripping voltammetry without sample pretreatment.

Copper and arsenic have been analysed in refined beet sugar at the microgram kg-1 level by anodic stripping voltammetry (copper) and cathodic stripping voltammetry (arsenic) in the differential-pulse mode (DPASV and DPCSV) at a hanging mercury drop electrode (HMDE). DPCSV measurements of arsenic are based on its accumulation onto the HMDE as an intermetallic Cu-As compound followed by the reduction of As0 to arsine in hydrochloric acid medium. Measurements were directly carried out on untreated sugar solutions. The performance of the procedures was compared with electrothermal atomic absorption spectrometry and stripping voltammetry applied to digested sugar samples, and showed in general better accuracy. The procedures were applied to the determination of these toxic elements in commercial beet sugar samples of concentrations below 50 micrograms kg-1 copper and 15 micrograms kg-1 arsenic were found, which are much lower that those allowed by the current regulations.

Arsenic↗

Immunoaffinity chromatography for the sample pretreatment of Taxus plant and cell extracts prior to analysis of taxanes by high-performance liquid chromatography.

The application of immunoaffinity chromatography for the purification of Taxus plant and cell extracts prior to the HPLC analysis is described. Polyclonal antibodies raised against 10-deacetylbaccatin III (10-DAB III), paclitaxel's main precursor in plant, were characterised by enzymed-linked immunosorbent assay. Immunoglobulins from selected antisera were immobilised on CNBr-activated Sepharose 4B. The immunoaffinity column was used for the purification of plant and plant cell culture extracts prior to their analysis by HPLC. Immunoaffinity chromatography enabled the selective concentration of taxoids and enhanced sample clean-up.

Antibodies↗

Carbonic anhydrase-immobilized precolumn for selective on-line sample pretreatment in high-performance liquid chromatographic determination of certain sulphonamide drugs.

Carbonic anhydrase (CA)-immobilized aminopropyl silica precolumn was developed for direct injection determination of certain sulphonamide drugs in biological fluids by column-switching (CS) high-performance liquid chromatography. Under the optimized conditions, only the sulphonamide drugs with an unsubstituted sulphonamide group were retained on the CA precolumn and separated on a reversed-phase analytical column. Of these, the retention of hydrochlorothiazide (HCT), chlorothiazide, acetazolamide, furosemide (FS) and chlorthalidone was almost quantitative. The peak area of HCT was proportional to the concentration in the range of 1-100 nmol/mL with relative standard deviations of 3.7% (5 nmol/mL) and 0.7% (100 nmol/mL). This CS system was applied to urine and plasma samples spiked with HCT and FS. Endogenous components of these were effectively removed, and HCT and FS were selectively retained on the CA precolumn. Almost quantitative recoveries and reproducibility were obtained.

Acetazolamide↗