PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Screen Time”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Performance of monolayered cervical smears in a gynecology outpatient setting in Kuwait.

OBJECTIVE: To compare ThinPrep (TP) Papanicolaou smears (Cytyc Corp., Box-borough, Massachusetts, U.S.A.) with matching conventional Papanicolaou (CP) smears for specimen adequacy, cytologic quality, diagnostic accuracy and screening time. STUDY DESIGN: In this prospective study of 1,024 women a split-sample, matched-pair design in favor of CP slides based on single-blind criteria was followed with a smear on a glass slide for CP and the remaining material collected in Preserv-Cyt solution (Cytyc) for a TP smear. A Cytobrush (Medscand, Hollywood, Florida, U.S.A.) was used for smear preparation for CP. TP smears were processed in ThinPrep 2000 (Cytyc). Smears were stained with Papanicolaou stain and were interpreted according to the Bethesda system. RESULTS: The number of satisfactory but limited (SBL) cases with TP were 77 (7.5%) as compared to 127 (12.4%) with the CP method. This reduction in SBL smears with the TP method and consequent increase in satisfactory smears were highly significant (P < .001) by McNemar's test. As regards unsatisfactory smears in discordant pairs, although the number of unsatisfactory smears was higher with TP (41 cases) as against CP (27 cases), the difference was not statistically significant (P < .05). The split-sample method showed a high correlation between the CP and TP diagnoses. TP smears had a significant advantage over CP smears in the reduction in the number of ASCUS and AGUS cases (14 vs. 29) (P < .05) and increased the pickup rate of LSIL, 6 vs. 1. Time taken to screen the TP smears was half that of CP smears. No cases of LSIL or HSIL were missed on TP smears. CONCLUSION: The liquid-based processor significantly improved the adequacy and quality of smears, resulting in fewer recall cases for SBL smears, leading to more definitive diagnoses in atypical cases, increasing the pickup rate of LSILs and reducing the screening time. A machine handling multiple specimens automatically would decrease cost and be an asset to a cytopathology laboratory.

Adolescent↗

Association between television, movie, and video game exposure and school performance.

BACKGROUND: The relationship between media exposure and school performance has not been studied extensively in adolescents. OBJECTIVE: The purpose of this work was to test the relative effects of television, movie, and video game screen time and content on adolescent school performance. METHODS: We conducted a population-based cross-sectional survey of middle school students (grades 5-8) in the Northeastern United States. We looked at weekday television and video game screen time, weekend television and video game screen time, cable movie channel availability, parental R-rated movie restriction, and television content restriction. The main outcome was self-report of school performance (excellent, good, average, or below average). We used ordinal logistic-regression analysis to test the independent effects of each variable, adjusting for demographics, child personality, and parenting style. RESULTS: There were 4508 students who participated in the study; gender was equally represented, and 95% were white. In multivariate analyses, after adjusting for other covariates, the odds of poorer school performance increased with increasing weekday television screen time and cable movie channel availability and decreased with parental restriction of television content restriction. As compared with children whose parents never allowed them to watch R-rated movies, children who watched R-rated movies once in a while, sometimes, or all of the time had significantly increased cumulative odds of poorer school performance. Weekend screen time and video game use were not associated with school performance. CONCLUSIONS: We found that both content exposure and screen time had independent detrimental associations with school performance. These findings support parental enforcement of American Academy of Pediatrics guidelines for media time (particularly weekdays) and content limits to enhance school success.

Achievement↗

Factors affecting patient radiation exposure during routine coronary angiography in a tertiary referral centre.

Cardiac catheterization is carried out by an increasing number of operators from district hospitals as well as tertiary referral centres. Procedures are not standardized and are at the discretion of individual operators. The purpose of this study was to describe the pattern of patient radiation dose and screening times associated with diagnostic cardiac catheterization, and explore determinants of radiation dose to patients and staff. Data were collected from 1337 diagnostic procedures carried out in two cardiac catheterization laboratories from January to June 1998. Screening time and radiation dose measured by dose-area product (DAP) meter were recorded. Status of the operator and type of investigation were determined. 22 operators had performed at least 15 left ventriculograms with coronary angiography (total 944 procedures). The average (+/- SD) was 40 (+/- 22) per operator. Screening times for individual operators varied from 2.0 (+/- 1.3) min to 5.0 (+/- 4.3) min with no relationship between time and number of cases. Consultants and visiting physicians had longer screening times and greater patient DAP readings. In comparison with 115 cases of coronary angiography alone, left ventriculography increased DAP reading from 14.24 (+/- 11.7) Gy cm2 to 20.26 (+/- 0.47) Gy cm2 (p < 0.0001). In 106 cases of coronary artery bypass graft angiography, an aortogram (n = 53) did not add significantly to radiation dose or screening time. A right heart catheter added approximately 5 min to screening time (9.13 (+/- 0.63) min with right heart (n = 83) vs 3.96 (+/- 0.12) min without right heart (n = 1234)), but did not affect radiation dose significantly. There is a wide range of screening times and radiation doses related to diagnostic cardiac catheterization. Visiting and consultant staff use greater radiation doses. Left ventriculography adds significantly to patients' radiation exposure. Aortography does not add significantly to radiation dose in cases of graft angiography.

Cardiology↗

Longitudinal physical activity and sedentary behavior trends: adolescence to adulthood.

BACKGROUND: There is little national research on longitudinal patterns of physical activity and sedentary behavior in ethnically diverse teens as they transition to adulthood. METHODS: Longitudinal questionnaire data from U.S. adolescents enrolled in Wave I (1994-1995) and Wave III (2001) of the National Longitudinal Study of Adolescent Health (n =13,030) were analyzed in January 2004. Incidence, reversal, and maintenance of achieving five or more weekly bouts of moderate to vigorous physical activity (MVPA) and < or =14 hours of weekly TV and video viewing, computer/video game use (screen time) were assessed. Multinomial logistic regression models examined the likelihood of achieving five or more weekly sessions of MVPA week and < or =14 hours screen time per week as an adolescent and/or young adult, controlling for household income, parental education, age of adolescent, and seasonality. RESULTS: Of those achieving five or more weekly sessions of MVPA and < or =14 hours of weekly screen time as adolescents, few continued to achieve these favorable amounts of activity (4.4%) and screen time (37.0%) as adults. More failed to maintain these favorable amounts of activity (31.1%) and screen time (17.3%) into adulthood. Black versus white females were more likely to maintain less [corrected] favorable amounts of activity from adolescence to adulthood (odds ratio [OR]=3.09; 95% confidence interval [CI]=1.49-6.42), while black males (OR=1.50; CI=1.05-2.14) and females (OR=2.00; CI=1.40-2.87) were more likely than whites to maintain less (versus more) favorable screen time hours. CONCLUSIONS: The vast majority of adolescents do not achieve five or more bouts of moderate physical activity per week, and continue to fail to achieve this amount of activity into adulthood.

Adolescent↗

Prevalence of hepatitis B markers (HBsAg and HBsAb) in women screened at time of delivery.

Two thousand women were screened at the time of delivery for two hepatitis B markers, surface antigen (HBsAg) and antibody (HBsAb), in order to determine prevalence rates, define high-risk groups and estimate the cost-efficiency of routine screening. It was found that 2.2% of the women were HBsAg positive and 32% of a 20% subsample were HBsAb positive. Jewish women of North African origin had the highest rates (HBsAg, 3.8%; HBsAb, 47%) and those of European origin had the lowest (1.2 and 14%, respectively). Bedouin women had intermediate rates (HBsAg, 1.1%; HBsAb, 28%). The issue of screening pregnant women for HBsAg is discussed in light of these results.

Adolescent↗

Reduction in the cumulative incidence rate of cervical cancer by one life time selective screening.

Mass scale cervical cytology which is the most accepted strategy for the control of cervical cancer cannot be undertaken in developing countries in view of paucity of resources, hence a need arises to examine alternate strategy. The present exercise attempts to study the reduction in cumulative incidence rate of cervical cancer by one life time selective screening. The results revealed that cumulative incidence rate (CIR) of cervical cancer per 100,000 in cohort of women during the age of 20 to 64 years was found to be 2555.0 in the absence of screening. One life time selective screening at the age of 40 and 45 years showed the reduction of 11.6 and 17.2% in CIR respectively where as respective estimates in case of complete screening at mentioned age groups were found to be 21.5% and 25%. In order to further conserve the resources the strategy seems to be optimum for developing countries.

Adult↗

[Factors associated with cancer screening participation, Korea].

OBJECTIVES: We wanted to identify those factors associated with stomach, colon, breast and cervix cancer screening. METHODS: A population-based telephone survey was conducted for 2 weeks (the 9th-23th of July, 2004) by trained interviewers with using a questionnaire. 2,598 respondents (females aged 30 years or over, and the males aged 40 years or over) were selected by random-digit dialing that was based on the 2000 Population and Housing Census. The data on socio-demographic, health behavior and enabling factors were collected. 2,571 respondents were included in analysis. The cancer screening rate was classified into 2 categories: the life time screening rate and the screening rate with recommendations. RESULTS: For the 2,571 respondents, the life time screening rate was as follows: 52.0% (Stomach), 25.3% (Colon), 55.9% (Breast) and 76.8% (Cervix). The screening rate with recommendation was as follows: 39.2% (Stomach), 20.6% (Colon), 42.5% (Breast) and 58.3% (Cervix). On a multiple logistic regression analysis of the life time screening, statistically significant relationships were observed for the screening intention, the health exam, the disease history, the age of the patients and the cancer screening rates. On a multiple logistic regression analysis of the screening with recommendation, statistically significant relationships were observed for the screening intention, the health exam, the age of the patients, the concern about the risk of cancer, the voluntary health insurance for cancer and the cancer screening rates. CONCLUSIONS: The results of this study suggest that the cancer screening intention, the health exam and the age of the patients are the most important factors to participate in life time cancer screening and also screening with recommendations. A positive association was also observed for the concern about the risk of cancer, the voluntary health insurance for cancer. It is hoped that this study will be a base line data for suggesting the representative cancer screening rate in Korea.

Adult↗

The usefulness of the Developmental Profile-II in developmental screening.

Timely provision of early developmental intervention depends on accurate developmental screening tests. The Developmental Profile-II (DP-II) relies on parent report to assess children from birth to 7 years old. One of its subtests, the Academic scale, is designed for developmental screening. To test its accuracy in detecting children with problems, the scale was administered to parents of 94 children between 6 and 75 months old. Each child was also given a battery of tests, such as the Bayley Scales of Infant Development and the Stanford-Binet Intelligence Scale. The Academic scale detected only 21% of the 19 children thus determined as having developmental problems, while 85% of the nondiagnosed children received normal or advanced scores on DP-II. Analysis revealed that DP-II scoring criteria are far too lenient and that many items are poorly placed in relation to age expectations. Alternative cutoff scores greatly improved sensitivity. DP-II is a potentially accurate measure that needs updating and restandardizing. Alternative tests include the Minnesota Child Development Inventory and the Battelle Developmental Inventory Screening Test.

Achievement↗

Tailored messages, external barriers, and women's utilization of professional breast cancer screening over time.

BACKGROUND: The efficacy of tailored messages on women's utilization of professional breast screening over time has not been examined often or in combination with external barriers (e.g., costs and access). The objectives of this study were to test the effects of alternative messages on mammography and clinical breast examination (CBE) utilization over time and to examine the combined effects of such messages and external barriers. METHODS: In a randomized, controlled trial, three message conditions were compared: no message (control group), recommendations about screening, or recommendations plus tailored discussion (on beliefs, feelings, costs, and access). Messages were delivered by advanced practice nurses over the telephone. Participants were women ages 51-80 years who had not had mammography in the prior 13 months. Outcome measures were women's mammography and CBE utilization 3-6 months postintervention (short-term follow-up) and 13-16 months after short-term follow-up (long-term follow-up). RESULTS: Both messages promoted mammography and CBE utilization at short-term follow-up. Utilization increased over time in all groups. Mammography utilization was greater for the tailored-message group compared with the recommendations-only group at long-term follow-up. Messages and external barriers had combined effects (Ps < 0.01). Among participants with high external barriers, participants in the message conditions-especially the tailored message-had the highest screening rates; among participants with low barriers, screening rates were similar across conditions. CONCLUSIONS: Clinicians can tailor discussions on beliefs, feelings, cost, and access about screening to promote professional breast screening over time, especially with women who have not had mammograms as recommended and who have external barriers to screening.

Aged↗

Effective dose at pneumatic reduction of paediatric intussusception.

AIM: The purpose of this study was to assess screening times and resulting dose implication at pneumatic reduction of intussusception in the paediatric age group and to examine the relationship with the outcome of the procedure. MATERIALS AND METHODS: We retrospectively reviewed the case notes and departmental records of 143 children who had undergone a total of 153 pneumatic reductions in our department over a 4-year period. Success rates, screening times and available dose-area products (DAP) were recorded. The DAPs were converted to effective dose (ED) for 77 procedures. RESULTS: A 76.5% (117/153) success rate was achieved with a recurrence rate of 6.5% and only one complication: a perforation. Screening times were recorded in 137 reductions and ranged from 15 s to 22.6 min. Although the longest screening time was associated with an unsuccessful outcome, the second longest time of 21 min was successful. This gave a DAP of 1278 cGy cm(2)and an ED of 12.73 mSv, which is equivalent to approximately 400 abdominal films for a 1-year-old. A lifetime risk of fatal cancer of one in 1000 was achieved, assuming the worst case, after a screening time of 30 min on our conventional fluoroscopy unit. CONCLUSION: Our success rate compares well with other centres. Our institution is a tertiary referral centre and the occasional long screening time may reflect the delay and complex nature of the patients referred. Persistence at air reduction may be successful and the success rate increases with delayed attempts but the risks of the increasing radiation burden must be weighed against the risks of emergency surgery and anaesthesia.Heenan, S. D. (2000). Clinical Radiology 55, 811-816.

Air↗

Expanded screening for HIV in the United States--an analysis of cost-effectiveness.

BACKGROUND: Although the Centers for Disease Control and Prevention (CDC) recommend routine HIV counseling, testing, and referral (HIVCTR) in settings with at least a 1 percent prevalence of HIV, roughly 280,000 Americans are unaware of their human immunodeficiency virus (HIV) infection. The effect of expanded screening for HIV is unknown in the era of effective antiretroviral therapy. METHODS: We developed a computer simulation model of HIV screening and treatment to compare routine, voluntary HIVCTR with current practice in three target populations: "high-risk" (3.0 percent prevalence of undiagnosed HIV infection; 1.2 percent annual incidence); "CDC threshold" (1.0 percent and 0.12 percent, respectively); and "U.S. general" (0.1 percent and 0.01 percent). Input data were derived from clinical trials and observational cohorts. Outcomes included quality-adjusted survival, cost, and cost-effectiveness. RESULTS: In the high-risk population, the addition of one-time screening for HIV antibodies with an enzyme-linked immunosorbent assay (ELISA) to current practice was associated with earlier diagnosis of HIV (mean CD4 cell count at diagnosis, 210 vs. 154 per cubic millimeter). One-time screening also improved average survival time among HIV-infected patients (quality-adjusted survival, 220.7 months vs. 219.8 months). The incremental cost-effectiveness was 36,000 dollars per quality-adjusted life-year gained. Testing every five years cost 50,000 dollars per quality-adjusted life-year gained, and testing every three years cost 63,000 dollars per quality-adjusted life-year gained. In the CDC threshold population, the cost-effectiveness ratio for one-time screening with ELISA was 38,000 dollars per quality-adjusted life-year gained, whereas testing every five years cost 71,000 dollars per quality-adjusted life-year gained, and testing every three years cost 85,000 dollars per quality-adjusted life-year gained. In the U.S. general population, one-time screening cost 113,000 dollars per quality-adjusted life-year gained. CONCLUSIONS: In all but the lowest-risk populations, routine, voluntary screening for HIV once every three to five years is justified on both clinical and cost-effectiveness grounds. One-time screening in the general population may also be cost-effective.

Anti-Retroviral Agents↗

Whether and where community health center users obtain screening services.

This study measures associations between minority and low socioeconomic status and the use of screening services for secondary prevention among adult community health center users. Among those who obtained timely screening services, the study also measures associations between minority and low socioeconomic status and obtaining these preventive services at a community health center. The data include 1,175 individuals ages 18 and older from a 1995 survey of community health center users. Minority and lower socioeconomic status adult community health center users were not less likely to obtain timely screening services than other adult community health center users. This differs from the trend in the general population. Minority and lower socioeconomic status community health center users who used timely screening services were more likely to obtain them at community health centers, which appear to facilitate the use of timely screening services for minority and low socioeconomic status users.

Adult↗

The learning curve in the training of percutaneous nephrolithotomy.

OBJECTIVES: To investigate the learning curve in the training of percutaneous nephrolithotomy (PCNL). METHODS: A total of 104 PCNL cases were included in this evaluation to define the learning curve of a surgeon with no previous experience at performing solo PCNL. Two parameters of expertise were reviewed, namely the operation and fluoroscopic screening times. The operation time was calculated as the beginning of access with the needle until the nephrostomy tube was placed and secured. PCNL procedures were analyzed in seven sets of 15 cases regarding the operation and fluoroscopy times, stone size, stone clearance rate, blood transfusion rate, and estimated blood loss. RESULTS: The mean operation time was 2.4 h for the first 15 patients. It decreased to a mean of 1.5 h for cases 46 through 60. No further decrease in the operation time was observed after case 60. The fluoroscopic screening time was a peak of 17.5 min in the first 15 cases, whereas it dropped to a mean of 8.9 min for cases 46 through 60. The decline in the mean fluoroscopy screening time continued in cases 61 to 104, but the decline was not significant. There was no significant difference in stone size, stone clearance rate, blood transfusion rate, and estimated blood loss among each set of cases. CONCLUSIONS: This study suggests that the surgical competence in PCNL can be reached after 60 cases. PCNL and fluoroscopy times drop to a steady-state level after performing 60 procedures.

Clinical Competence↗

Ionising radiation exposure to orthopaedic trainees: the effect of sub-specialty training.

INTRODUCTION: We monitored image intensifier use by orthopaedic trainees to assess their exposure to ionising radiation and to investigate the influence of sub-specialty training. MATERIALS AND METHODS: Five different orthopaedic registrars recorded their monthly image intensifier screening times and exposure doses for all cases (trauma and elective), for a combined total of 12 non-consecutive months. Radiation exposure was monitored using shoulder and waist film badges worn both by surgeons and radiographers screening their cases. RESULTS: Registrars in spinal sub-specialties were exposed to significantly higher doses per case and cumulative doses per month than non-spinal trainees (P < 0.05), but significantly lower screening times per case (P < 0.05). There were no significant differences in cumulative screening times per month (P > 0.05). Regression analysis for all surgeons showed a significant relationship between shoulder film badge reading and cumulative dose exposed per month (P < 0.05), but not for cumulative screening time. Shoulder film badge recordings were significantly higher for spinal compared with non-spinal registrars (P < 0.05), although all badges were below the level for radiation reporting. Only one radiographer badge recorded a dose above threshold. CONCLUSIONS: Whilst the long-term effects of sub-reporting doses of radiation are not fully understood, we consider that this study demonstrates that trainees should not be complacent in accepting inadequate radiation protection. The higher doses encountered with spinal imaging means that sub-specialty trainees should be alerted to the risk of their increased exposure. The principle of minimising radiation exposure must be maintained by all trainees at all times.

Film Dosimetry↗

A data-analytic approach for estimating lead time and screening benefit based on survival curves in randomized cancer screening trials.

Screening tests are used frequently for control of diseases such as cancer. The increased survival time of screen-detected cases over those that are detected clinically may be due in part to 'lead time', or the length of time by which the disease is diagnosed earlier by screening in the presence or absence of any real extension in survival time. A realistic evaluation of screening needs to assess the true benefit of screening; that is, the length of time by which survival has been extended, beyond merely the time of the advanced diagnosis. The comparison of survival measured from time of entry between cases in a screening arm and in a control arm in randomized studies avoids the lead time bias. If the effects of average lead time and average benefit on survival are additive, these effects can be estimated by recognizing that (a) the difference in survival curves since time of diagnosis confounds benefit and lead time, but (b) the difference in survival curves since time of start of study involves benefit only. The method is evaluated on simulated data for its accuracy and may be used on data from randomized studies.

Bias↗

Assessing slide coverage by cytoscreeners during the primary screening of cervical smears, using the AxioHOME Microscope system.

We have used the HOME Microscope system to examine the screening patterns of cytotechnologists who undertake the primary screening of cervical smears, in order to measure accuracy of screening against screening time, slide coverage, and mean screening rate. Twelve cytotechnologists engaged routinely on cervical screening volunteered for this study. They were asked to perform primary screening of 10 test slides under normal laboratory conditions in the normal way. Slide coverage and screening time were recorded on the HOME system. Slide maps were prepared and the results analysed. The exercise demonstrated that all primary screeners fail at some point to scan the whole of the slide during primary screening. The maps produced by the HOME system clearly demonstrated that 5 different types of error can occur that lead to incomplete coverage of the slide. Mean slide coverage was 84%, and some individuals averaged only 66% coverage. The results show that there is a major problem in the education of some individual cytotechnologists in slide coverage. This could be rectified by the incorporation of a HOME system into every training centre, and the establishment of a protocol for assessment of slide coverage in competence examinations. Furthermore, the exercise has shown that even those individuals who normally attain a good standard of slide coverage would be able to improve slide coverage given access to the daily use of a HOME Microscope, or a system with equivalent screening/reviewing functionality.

Clinical Laboratory Techniques↗

Ionising radiation during internal fixation of extracapsular neck of femur fractures.

This study analyses the relationship between the level of experience of both surgeon and radiographer and the radiation dose administered in theatre, during fixation of extracapsular proximal femoral fractures. From the 63 dynamic hip screw procedures performed, 10 were done by Senior House Officers (SHOs), 10 by Consultants and 43 by Registrars, whereas Basic Radiographers were involved in all cases. Fractures were classified as two part, three part or four part. A four part fracture required higher levels of radiation dose and screening time as compared with a two part fracture. All two part fractures were screened by radiographers of similar experience; however, the radiation dose and screening time were different amongst different levels of surgeon. The highest radiation dose and screening times were recorded when an SHO was the operating surgeon and the lowest when a registrar was the surgeon. The two part and three part fractures performed by registrars were subdivided according to the experience of the radiographer. In both cases a statistically significant difference was found between the dose of radiation administered in theatre and the years of experience of the radiographers (p < 0.05).

Aged↗

The learning curve of selective salpingography and tubal catheterization.

OBJECTIVE: To determine the effect of increasing experience in fluoroscopically guided selective salpingography and tubal catheterization on radiation doses and screening times, thus establishing a learning curve for the procedure. DESIGN: Retrospective case note analysis. SETTING: IVF center of an academic teaching hospital. PATIENTS: Three hundred sixty-six patients with infertility seen over 3.5 years. INTERVENTION(S): Fluoroscopically guided selective salpingography and tubal catheterization. MAIN OUTCOME MEASURE(S): Reductions in radiation doses and screening times for different categories of selective salpingography and tubal catheterization, expressed as percentage reductions during the study period and reductions per 10 procedures. RESULT(S): During the study period, The median dose of radiation decreased by 62.6%-71.9%, and the median screening time declined by 61.5%-78.5%. Reductions per 10 procedures were 2.5%-4.2% and 2.7%-5%, respectively. CONCLUSION(S): Significant reductions in radiation doses and screening times start early in a clinical team's practice of selective salpingography and tubal catheterization and continue even as trainees are added to the pool of operators.

Catheterization↗