Sick building syndrome: an emerging stress-related disorder?

BACKGROUND: This study examined the role of work-related psychosocial stress in the aetiology of sick building syndrome and tested the hypothesis that in buildings with no recognized environmental problems, health complaints typical of the syndrome were primarily stress-related. METHOD: A case-control study used data from confidential questionnaires to assess symptoms and perception of the physical and psychosocial environment among 2160 subjects in 67 offices. Working conditions were also inspected and indoor air quality monitored. RESULTS: We found an incremental trend in prevalence of sick building syndrome among office workers who reported high levels of physical and mental stress, and decreasing climate of co-operation. This association was confirmed after multivariate adjustment for significant personal and environmental exposure factors. Using a subsample, we further modelled interaction between stress and the other covariates but none achieved statistical significance. CONCLUSION: Our study confirmed stress to be a significant and independent determinant of the health complaints, and that symptoms compatible with the sick building syndrome in many cases were stress-related. Our findings underscore the importance of personal and organizational stress management to prevent ill health at the office.

Adolescent↗

The feasibility of using a double blind experimental cross-over design to study interventions for sick building syndrome.

Methodological problems have limited scientific investigation of the causes of and solutions for sick building syndrome. The feasibility of using an experimental double blind cross-over study to resolve many of these methodological problems was assessed in a pilot study. The experimental intervention was to vary the amount of outdoor air from 10 cubic feet per minute per person (cfmpp) to 20 cfmpp or 50 cfmpp by central manipulation of the building heating, ventilation and air-conditioning (HVAC) system. Over 6 consecutive study weeks, 2 trials of rates were administered in random order. Study subjects and investigators of the study were blinded to intervention sequence. Unblinding, office environment rating and symptom occurrence were measured weekly. Of 305 eligible workers, 254 participated. Problems were encountered in delivering the lowest dose of ventilation due to building leakage. The prevalence of symptoms diminished steadily over the 6 study weeks, time trends which could be controlled by recommended design modifications. Blinding to the intervention was successfully maintained. Weekly non-response did not introduce a response bias but reduced the number of subjects available for analysis by one-third for each trial. We conclude that this design, with certain modifications, is feasible to evaluate many proposed interventions for sick building syndrome.

Adult↗

[Sick building syndrome or fungal allergy? When houses cause illness].

In modern societies, the sick building syndrome (SBS) is a very common building-related complex of unspecific symptoms affecting groups of persons. Most frequently, complains include irritation of the eyes and respiratory tract that are believed to be related to negative ambient factors at the workplace. The etiology is multifactorial. In persons showing typical anxiety about the environment, SBS may also be considered a variant of a somatoform disorder. SBS must be clearly differentiated from building-related illness. Diagnostic measures and therapeutic implications are discussed.

Air Pollutants, Occupational↗

Building-related illnesses and sick building syndrome.

Worker-related complaints of sick building and/or building-related illnesses are being recognized increasingly. Clinicians need to become more familiar with these syndromes which include asthma, humidifier fever, hypersensitivity pneumonitis and allergic rhinitis. In addition, various infectious diseases such as legionellosis, Q fever and viral respiratory conditions may be building exposure linked. Finally, toxin exposures to indoor air chemicals ranging from volatiles, copy paper, glue, and pesticides may be linked to health sequelae. Thus, these patients should have serious considerations, particularly where cluster illnesses with documented respiratory disorders and skin rashes are identified. Appropriate measures for diagnosis, treatment, documentation and advocacy for employee relocation pending corrective actions should follow.

Air Pollutants, Occupational↗

Environmental, occupational, and personal factors related to the prevalence of sick building syndrome in the general population.

Possible relations between prevalence of sick building syndrome (SBS) and environmental, occupational, and personal factors were studied in a random sample (0.1%) of the general population aged 20-65 in a three county region in middle Sweden. Childhood exposure to environmental tobacco smoke from smoking mothers and a childhood in urban areas was related to SBS symptoms. Current urban residency, fresh paint, and preschool children in the dwelling were also related to symptoms. Other residential factors such as age of building, type of building, degree of crowding, mechanical ventilation, or signs of moisture or mould growth were not related to symptoms. Other factors related to symptoms were history of atopy, allergy to nickel, proneness to infection, hyperreactivity, static electricity, work with video display units (VDU), work satisfaction, and climate of cooperation at work. Age, sex, marital state, education level, work stress, obesity, current or earlier smoking, regular physical exercise, or occupational exposure to chemicals did not correlate with symptoms. Women had a higher proportion of symptoms than men but these differences were not significant when adjusting for differences in allergy to nickel, hyperreactivity, and proneness to infection. Maternal smoking was related to a twofold increase of both atopy and allergy to nickel in the adult offspring. Eye symptoms were most common in administrative, managerial, and service work. Airway symptoms were most common in transport and communication work. Dermal symptoms were most common in professional and technical and related work. General symptoms were most common in service, health, hospital, and social work. The lowest prevalence of symptoms was found in agricultural, forestry, and sales work. Women and subjects allergic to nickel worked more often in occupations without exposure to chemicals, but no evidence was found for selection mechanisms causing sensitive persons to move from exposed to unexposed occupations. It was concluded that symptoms included in SBS are common in the general population, and of multifactorial origin related to both personal, occupational, and residential factors, and certain environmental exposures such as maternal smoking, the urban environment, VDU work, and volatile organic hydrocarbons from newly painted dwellings.

Adult↗

Personal and psychosocial factors and symptoms compatible with sick building syndrome in the Swedish workforce.

A random sample of 1000 subjects (20-65 years of age) received a postal questionnaire regarding sick building syndrome (SBS), including the three-dimensional model of demand-control-support (DCS). The response rate was 70% (n = 695), and 532 were occupationally active. Female gender and atopy were the main predictors of symptoms. Eye symptoms were more common at low social support combined with strained work situation [odds ratio (OR) 2.37], and at high social support combined with active work situation (OR 3.00). Throat symptoms were more common at low social support combined with either passive (OR 1.86) or strained situation (OR 2.42). Tiredness was more common at low social support combined with either passive (OR 2.41), strained (OR 2.25), or active situation (OR 1.87), and at high social support combined with active work situation (OR 1.83). Low social support combined with either passive (P = 0.01) or strained job situation (P = 0.01) was associated with a higher symptom score (SC). The lowest SC was found at a relaxed work situation, irrespective of social support. In conclusion, female gender, low age, asthma, atopy and psychosocial work environment are associated with symptoms. The three-dimensional model can predict symptoms compatible with SBS, but in a more complex way than earlier research indicated. Practical Implications A multi-disciplinary approach, including psychosocial stress factors as well as personal factors such as gender, age, atopy and asthma, and indoor exposures, should be applied in studies on symptoms compatible with sick building syndrome (SBS). Males and females perceive psychosocial work conditions differently, and may react differently to job stressors. The psychosocial work environment can be as important as gender and atopy as a predictor of SBS symptoms.

Adult↗

Prevalence of objective eye manifestations in people working in office buildings with different prevalences of the sick building syndrome compared with the general population.

A cross-sectional clinical epidemiological study was carried out among 169 office workers in four Copenhagen town halls with different prevalences of the sick building syndrome. The results were compared with those in 112 subjects randomly selected from the general population. Biomicroscopic eye manifestations, such as premature break-up of the precorneal tear film, absence of foam at the inner eye canthus and epithelial damage of the bulbar conjunctiva, were investigated together with self-reported eye complaints. Although intercorrelated, the objective eye manifestations independently were statistically associated with self-reported eye complaints in office workers. The prevalence of the objective eye manifestations was significantly elevated in office workers compared with the general population and most pronounced for the buildings with a high prevalence of the sick building syndrome (P < 0.001). In the general population, subjects with a non-industrial occupation, including office workers, had a significantly higher prevalence of objective eye manifestations than those with an industrial occupation (P = 0.03), but the prevalence was still significantly lower than that among the office workers in buildings with a high prevalence of the sick building syndrome (P < 0.001). Since possible confounders were found not to explain the difference in prevalence of objective eye manifestations and complaints among the two populations, it is concluded that the office environment (buildings and/or type of office work) promotes these objective changes accompanied by self-reported complaints.

Adult↗

Prevalence of the sick building syndrome symptoms in office workers before and after being exposed to a building with an improved ventilation system.

OBJECTIVE: To find if the prevalence of symptoms associated with sick building syndrome decreased among office workers after moving to a building with improved ventilation (after controlling for potential confounders). METHODS: Workers in five buildings in 1991 all moved in 1992 into a single building with improved design, operation, and maintenance of the ventilation system. All buildings had sealed windows with mechanical ventilation, air conditioning, and humidification. Workers completed a self administered questionnaire during normal working hours in February 1991 and February 1992. The questionnaire encompassed symptoms of the eyes, nose and throat, respiratory system, skin, fatigue, headache, and difficulty concentrating, personal, psychosocial, and work related factors. During normal office hours of the same week environmental variables were measured. RESULTS: The study population comprised 1390 workers in 1991 and 1371 workers in 1992 who represented more than 80% of the eligible population. The prevalence of most symptoms decreased when workers moved to the new building: skin (54%), respiratory system (53%), nose and throat (46%), fatigue (44%), headache (37%), eyes (23%). These findings were all significant and remained generally similar after controlling for personal, psychosocial, and work related factors. Furthermore, more than 60% of workers symptomatic in 1991 were asymptomatic in 1992 for all types of symptoms. In contrast, less than 15% of workers were asymptomatic in 1991 but symptomatic in 1992 for all types of symptoms. CONCLUSION: In this study, the prevalence of most symptoms usually associated with the sick building syndrome decreased by 40% to 50% after workers were transferred to a building with an improved ventilation system. The results show that it is possible to diminish the prevalence of symptoms associated with the sick building syndrome among office workers occupying a building with mechanical ventilation, air conditioning, and sealed windows.

Female↗

Volatile organic compounds, respirable dust, and personal factors related to prevalence and incidence of sick building syndrome in primary schools.

Possible relations between incidence and prevalence of sick building syndrome (SBS), indoor exposures, and personal factors were studied in a four year longitudinal study among personnel (n = 129) in six primary schools. The mean concentration of carbon dioxide was above the recommended value of 0.08 microliter/l (800 ppm) in all schools, indicating a poor outdoor air supply. Indoor concentration of volatile hydrocarbon (VOC) was enhanced at high room temperatures. Respirable dust, but not concentration of VOC was enhanced at lower ventilation rates and high air humidity. Chronic SBS was related to VOC, previous wall to wall carpeting in the schools, hyper-reactivity, and psychosocial factors. Incidence of new SBS was related to concentration of respirable dust, current smoking, and the psychosocial climate. Remission of hyperreactivity, decrease in sick leave owing to airway illness, removal of carpeting in the schools, and moving from new to old dwellings resulted in a decrease in SBS score. It is concluded that SBS is of multifactorial origin, related to a variety of factors and exposures. The total concentration of hydrocarbons is a simple and convenient measure of exposure, which also seems to be a predictor of chronic symptoms. Further investigations on the effect of temperature, ventilation, and air humidity on SBS should consider how these factors may influence the chemical composition of the air. Because poor air quality in schools could also affect the children, it may have implications for the state of health of a large proportion of the population.

Carbon Dioxide↗

Sick building syndrome--know your ventilation rates.

To summarise, although the occurrence of sick building syndrome could be due to a range of causal factors, research shows that it is probable that low outside air intake volume and pollution generated by the ventilation system and the building contents play a role in producing its effects. This being so, it is important that the flow of outside air into the building and the distribution of fresh or mixed air around the interior are known and controlled. However it is difficult to control the flow rate by conventional means and the use of fixed minimum position dampers is not likely to maintain a minimum fresh air flow rate under most wind velocities. What is needed is a control system which relies on direct measurement of air flow rate connected to a modulated minimum outside air intake damper to provide a constant and verifiable volume of fresh air flow. Flow sensors also open up the possibility of direct measurement and control of return and mixed air volumes and of course the flow of air anywhere else in the system.

Air Pollution, Indoor↗

Multiple logistic regression modelling substantiates multifactor contributions associated with sick building syndrome in residential interiors in Mauritius.

This paper presents a mathematical model that depicts the relationship between the possibility of occurrence of common health problems and factors leading to Sick Building Syndrome symptoms in domestic interiors in Mauritius. The prevalence of upper respiratory symptoms (dry eyes, runny nose), central nervous system symptoms (headache, nervousness), and musculoskeletal symptoms (pain/stiffness in shoulders/neck) were found to be elevated when responses were statistically regressed to type of building and age of respondents. The model presented here will be useful in helping to identify and quantify the relative role of factors that contribute to Sick Building Syndrome. Thus it may be possible to evaluate the effectiveness of current building operation practices and to prioritise allocations of resources for reduction of risk associated with Indoor Environmental Air Quality.

Adult↗

Dysfunctional buildings or dysfunctional people: an examination of the sick building syndrome and allied disorders.

As Bauer et al. (1992) have indicated, psychological variables may play a prominent role in workplace-related disorders, like sick building syndrome. To place their work in a broader context, a spectrum of workplace disorders is described that encompasses sick building syndrome, building-related illness, neurotoxic disorders, and mass psychogenic illness. For each disorder, the authors identify both the building- (or exposure-) related variables and the psychological variables believed to trigger or maintain the unique pattern of somatic and neuropsychiatric symptoms. Strategies to aid in diagnostically differentiating the four syndromes are also discussed.

Air Pollution, Indoor↗

Ventilation rate in office buildings and sick building syndrome.

OBJECTIVE: To examine the relation between ventilation rate and occurrence of symptoms of the eyes, nose, throat, and skin as well as general symptoms such as lethargy and headache, often termed the sick building syndrome. METHODS: A cross sectional population based study was carried out in 399 workers from 14 mechanically ventilated office buildings without air recirculation or humidification, selected randomly from the Helsinki metropolitan area. The ventilation type and other characteristics of these buildings were recorded on a site visit and the ventilation in the rooms was assessed by measuring the airflow through the exhaust air outlets in the room. A questionnaire directed at workers inquired about the symptoms and perceived air quality and their possible personal and environmental determinants (response rate 81%). The outcomes were weekly work related symptoms experienced during the previous 12 months and symptom groups defined either by their anatomical location or hypothesised mechanism. RESULTS: In logistic regression analysis, the adjusted odds ratio (OR) for any symptom of interest was 3.03 (95% confidence interval (95% CI) 1.13 to 8.10) in the very low ventilation category of below 5 l/s per person and 2.24 (0.89 to 5.65) in the high ventilation category of over 25 l/s per person compared with the reference (15- < 25 l/s). The ORs for ocular (1.27, 1.11 to 1.46), nasal (1.17, 1.06 to 1.29), skin symptoms (1.18, 1.05 to 1.32), and lethargy (1.09, 1.00 to 1.19) increased significantly by a unit decrease in ventilation from 25 to 0 l/s per person. CONCLUSION: The results suggest that outdoor air ventilation rates below the optimal (15 to 25 l/s per person) increase the risk of the symptoms of sick building syndrome with the sources of pollutants present in mechanically ventilated office buildings. The Finnish guideline value is 10 l/s per person.

Adult↗

Perceived air quality, sick building syndrome (SBS) symptoms and productivity in an office with two different pollution loads.

Perceived air quality, Sick Building Syndrome (SBS) symptoms and productivity were studied in an existing office in which the air pollution level could be modified by introducing or removing a pollution source. This reversible intervention allowed the space to be classified as either non-low-polluting or low-polluting, as specified in the new European design criteria for the indoor environment CEN CR 1752 (1998). The pollution source was a 20-year-old used carpet which was introduced on a rack behind a screen so that it was invisible to the occupants. Five groups of six female subjects each were exposed to the conditions in the office twice, once with the pollution source present and once with the pollution source absent, each exposure being 265 min in the afternoon, one group at a time. They assessed the perceived air quality and SBS symptoms while performing simulated office work. The subject-rated acceptability of the perceived air quality in the office corresponded to 22% dissatisfied when the pollution source was present, and to 15% dissatisfied when the pollution source was absent. In the former condition there was a significantly increased prevalence of headaches (P = 0.04) and significantly lower levels of reported effort (p = 0.02) during the text typing and calculation tasks, both of which required a sustained level of concentration. In the text typing task, subjects worked significantly more slowly when the pollution source was present in the office (P = 0.003), typing 6.5% less text than when the pollution source was absent from the office Reducing the pollution load on indoor air proved to be an effective means of improving the comfort, health and productivity of building occupants.

Adult↗

Indoor biological contaminants and symptoms of sick building syndrome in office buildings in Mauritius.

This study was carried out to investigate possible relationship between bio-contaminants and symptoms of sick building syndrome among office workers in Mauritius. Viable microbial colonies were collected using a Casella slit sampler in 23 selected indoor office buildings. A questionnaire survey as well as a walk through investigation was undertaken. Physico-chemical measurements were also monitored in the selected offices. Results of this study showed that number of indoor bacterial bioaerosol concentrations ranged between 3 and 1110 CFU/m(3) while fungal counts were 0-196 CFU/m(3). However, most of the buildings showed absence of dust mites. In conclusions fungal contamination was found to be associated with the onset of sick building syndrome symptoms among workers in office buildings in Mauritius.

Air Pollution, Indoor↗

Textile wall materials and sick building syndrome.

We studied the relation between the amount of textile and other soft fiber wall materials used in the office and the symptoms related to sick building syndrome in two identical, mechanically ventilated, eight-story office buildings. The study population consisted of 400 workers (85% of the source population): 264 males (66%) and 136 females (34%). A self-administered questionnaire inquired about the occurrence of symptoms and related personal and environmental determinants. The office environment was assessed concurrently. Exposure was defined as the surface area of textile or other soft wall material (SWM) in the office. The outcomes were formed using the 7-d prevalences of individual symptoms, including mucosal irritation score (eye irritation, nasal dryness, nasal congestion, pharyngeal irritation); allergic reaction score (eye irritation, nasal congestion, nasal excretion, sneezing); asthma reaction score (wheezing, breathlessness, cough); skin reaction score (dryness, itch, or irritation, rash); and general symptom score (headache, lethargy). In the logistic regression controlling for potential confounders, the adjusted odds ratio for the symptoms of mucosal irritation was 1.82 (95% confidence interval [95% CI] = 1.14, 2.90) in the low-exposure group, compared with the unexposed reference group; and 2.46 (95% CI = 1.15, 5.28) in the high-exposure group, compared with the reference group. Corresponding odds ratios for the symptoms of allergic reaction were 1.82 (95% CI = 1.14, 2.90) and 3.16 (95% CI = 1.41, 7.09). No difference was found in the risk for asthmatic or skin reactions or general symptoms. The results support a hypothesis that textile and other soft-fiber wall materials used in the office environment are possible determinants of sick building syndrome.

Adult↗

Sick building syndrome (SBS) and exposure to water-damaged buildings: time series study, clinical trial and mechanisms.

Occupants of water-damaged buildings (WDBs) with evidence of microbial amplification often describe a syndrome involving multiple organ systems, commonly referred to as "sick building syndrome" (SBS), following chronic exposure to the indoor air. Studies have demonstrated that the indoor air of WDBs often contains a complex mixture of fungi, mycotoxins, bacteria, endotoxins, antigens, lipopolysaccharides, and biologically produced volatile compounds. A case-series study with medical assessments at five time points was conducted to characterize the syndrome after a double-blinded, placebo-controlled clinical trial conducted among a group of study participants investigated the efficacy of cholestyramine (CSM) therapy. The general hypothesis of the time series study was that chronic exposure to the indoor air of WDBs is associated with SBS. Consecutive clinical patients were screened for diagnosis of SBS using criteria of exposure potential, symptoms involving at least five organ systems, and the absence of confounding factors. Twenty-eight cases signed voluntary consent forms for participation in the time-series study and provided samples of microbial contaminants from water-damaged areas in the buildings they occupied. Twenty-six participants with a group-mean duration of illness of 11 months completed examinations at all five study time points. Thirteen of those participants also agreed to complete a double-blinded, placebo-controlled clinical trial. Data from Time Point 1 indicated a group-mean of 23 out of 37 symptoms evaluated; and visual contrast sensitivity (VCS), an indicator of neurological function, was abnormally low in all participants. Measurements of matrix metalloproteinase 9 (MMP9), leptin, alpha melanocyte stimulating hormone (MSH), vascular endothelial growth factor (VEGF), immunoglobulin E (IgE), and pulmonary function were abnormal in 22, 13, 25, 14, 1, and 7 participants, respectively. Following 2 weeks of CSM therapy to enhance toxin elimination rates, measurements at Time Point 2 indicated group-means of 4 symptoms with 65% improvement in VCS at mid-spatial frequency-both statistically significant improvements relative to Time Point 1. Moderate improvements were seen in MMP9, leptin, and VEGF serum levels. The improvements in health status were maintained at Time Point 3 following a 2-week period during which CSM therapy was suspended and the participants avoid re-exposure to the WDBs. Participants reoccupied the respective WDBs for 3 days without CSM therapy, and all participants reported relapse at Time Point 4. The group-mean number of symptoms increased from 4 at Time Point 2 to 15 and VCS at mid-spatial frequency declined by 42%, both statistically significant differences relative to Time Point 2. Statistically significant differences in the group-mean levels of MMP9 and leptin relative to Time Point 2 were also observed. CSM therapy was reinstated for 2 weeks prior to assessments at Time Point 5. Measurements at Time Point 5 indicated group-means of 3 symptoms and a 69% increase in VCS, both results statistically different from those at Time Points 1 and 4. Optically corrected Snellen Distance Equivalent visual acuity scores did not vary significantly over the course of the study. Group-mean levels of MMP9 and leptin showed statistically significant improvement at Time Point 5 relative to Time Points 1 and 4, and the proportion of participants with abnormal VEGF levels was significantly lower at Time Point 5 than at Time Point 1. The number of participants at Time Point 5 with abnormal levels of MMP9, leptin, VEGF, and pulmonary function were 10, 10, 9, and 7, respectively. The level of IgE was not re-measured because of the low incidence of abnormality at Time Point 1, and MSH was not re-measured because previously published data indicated a long time course for MSH improvement. The results from the time series study supported the general study hypothesis that exposure to the indoor air of WDBs is associated with SBS. High levels of MMP9 indicated that exposure to the complex mixture of substances in the indoor air of the WDBs triggered a pro-inflammatory cytokine response. A model describing modes of action along a pathway leading to biotoxin-associated illness is presented to organize current knowledge into testable hypotheses. The model links an inflammatory response with tissue hypoxia, as indicated by abnormal levels of VEGF, and disruption of the proopiomelanocortin pathway in the hypothalamus, as evidenced by abnormalities in leptin and MSH levels. Results from the clinical trial on CSM efficacy indicated highly significant improvement in group-mean number of symptoms and VCS scores relative to baseline in the 7 participants randomly assigned to receive 2 weeks of CSM therapy, but no improvement in the 6 participants assigned placebo therapy during that time interval. However, those 6 participants also showed a highly significant improvement in group-mean number of symptoms and VCS scores relative to baseline following a subsequent 2-week period of CSM therapy. Because the only known benefit of CSM therapy is to enhance the elimination rates of substances that accumulate in bile by preventing re-absorption during enterohepatic re-circulation, results from the clinical trial also supported the general study hypothesis that SBS is associated with exposure to WDBs because the only relevant function of CSM is to bind and remove toxigenic compounds. Only research that focuses on the signs, symptoms, and biochemical markers of patients with persistent illness following acute and/or chronic exposure to WDBs can further the development of the model describing modes of action in the biotoxin-associated pathway and guide the development of innovative and efficacious therapeutic interventions.