PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “computed tomography imaging”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Analysis of 3D bone ingrowth into polymer scaffolds via micro-computed tomography imaging.

This paper illustrates the utility of micro-computed tomography (micro-CT) to study the process of tissue engineered bone growth. A micro-CT facility for imaging and visualising biomaterials in three dimensions (3D) is described. The facility is capable of acquiring 3D images made up of 2000(3) voxels on specimens up to 60mm in extent with resolutions down to 2 microm. This allows the 3D structure of tissue engineered materials to be imaged across three orders of magnitude of detail. The capabilities of micro-CT are demonstrated by imaging the Haversian network within human femoral cortical bone (distal diaphysis) and bone ingrowth into a porous scaffold at varying resolutions. Phase identification combined with 3D visualisation enables one to observe the complex topology of the canalicular system of the cortical bone. Imaging of the tissue engineered bone at a scale of 1cm and resolutions of 10 microm allows visualisation of the complex ingrowth of bone into the polymer scaffold. Further imaging at 2 microm resolution allows observation of bone ultra-structure. These observations illustrate the benefits of tomography over traditional techniques for the characterisation of bone morphology and interconnectivity and performs a complimentary role to current histomorphometric techniques.

Bone Density↗

Neural-network-based classification of cognitively normal, demented, Alzheimer disease and vascular dementia from single photon emission with computed tomography image data from brain.

Single photon emission with computed tomography (SPECT) hexamethylphenylethyleneamineoxime technetium-99 images were analyzed by an optimal interpolative neural network (OINN) algorithm to determine whether the network could discriminate among clinically diagnosed groups of elderly normal, Alzheimer disease (AD), and vascular dementia (VD) subjects. After initial image preprocessing and registration, image features were obtained that were representative of the mean regional tissue uptake. These features were extracted from a given image by averaging the intensities over various regions defined by suitable masks. After training, the network classified independent trials of patients whose clinical diagnoses conformed to published criteria for probable AD or probable/possible VD. For the SPECT data used in the current tests, the OINN agreement was 80 and 86% for probable AD and probable/possible VD, respectively. These results suggest that artificial neural network methods offer potential in diagnoses from brain images and possibly in other areas of scientific research where complex patterns of data may have scientifically meaningful groupings that are not easily identifiable by the researcher.

Aged↗

Evaluation of humeral head erosions in rheumatoid arthritis: a comparison of ultrasonography, magnetic resonance imaging, computed tomography and plain radiography.

The value of ultrasonography (US), magnetic resonance imaging (MRI), computed tomography (CT) and plain radiography (PR) in detecting bone erosions on the humeral head was evaluated in a study of 26 in-patients (26 shoulders) with rheumatoid arthritis (RA). MRI depicted humeral erosions in 25 (96%), US in 24 (92%), CT in 20 (77%) and PR in 19 (73%) of the 26 shoulders. MRI and US were superior to CT in detecting small erosions. US was the most sensitive method to show surface erosions on the greater tuberosity. US, CT and MRI detected large erosions quite similarly. PR frequently missed small erosions. In the evaluation of early erosions in the rheumatoid shoulder, US and MRI are more sensitive methods than the traditionally used PR. US and MRI are suitable for the evaluation of soft-tissue involvement in the rheumatoid shoulder, but also for the detection of bone erosions of the humeral head.

Adult↗

Assessment of the progression of emphysema by quantitative analysis of spirometrically gated computed tomography images.

RATIONALE AND OBJECTIVES: The authors assessed the progression of pulmonary emphysema by means of quantitative analysis of computed tomography images. METHODS: Twenty-three patients suffering from emphysema due to an alpha 1-antitrypsin deficiency, aged 45 +/- 7 years and exsmokers, were scanned twice with a 1-year time interval. At 90% of the vital lung capacity, slices with a thickness of 1.5 mm were acquired at the level of the carina and 5 cm above the carina; slices with a thickness of 1 cm were acquired 5 cm below the carina. The entire lung was scanned spirally at a respiratory status, corresponding with 75% of the total lung capacity at baseline. The mean lung densities (MLD) were calculated in an objective manner with new analytic software featuring automated detection of the lung contours. RESULTS: Mean lung densities decreased by 14.2 +/- 12.0 Hounsfield units (HU; P < 0.001) above the carina, by 18.1 +/- 14.4 HU (P < 0.001) at the carina level, by 23.6 +/- 15.0 HU (P < 0.001) below the carina, and by 12.8 +/- 22.2 HU (P < 0.01) for the entire lung. The decrease in MLD was most obvious in the lower lung lobes. For the same patient group, the annual decrease in the forced expiratory volume (FEV1) and the carbon monoxide-diffusion were 120 +/- 190 mL (P < 0.01) and 10 +/- 70 mmol/kg/minute ( P < 0.2), respectively. No significant correlation was found between the decrease in MLD and the decrease in FEV1. CONCLUSIONS: Progression of emphysema can be assessed in an objective manner based on the mean lung density (MLD), measured from computed tomography volume scans as well as from single-slice scans. Mean lung density has proved to be more sensitive than FEV1 and carbon monoxide-diffusion.

Adult↗

Segmentation of cancellous bone from high-resolution computed tomography images: influence on trabecular bone measurements.

The quantification of cancellous bone network from computed tomography (CT) images requires a segmentation step which is crucial and difficult because of the partial volume effect in CT images. In this paper, we present and evaluate a new approach for segmenting cancellous bone network from high-resolution CT (HRCT) slices. The idea is first to detect a skeleton from the crest lines of the structure and then to thicken it to extract the whole bone structure by satisfying local neighborhood constraints. The segmentation requires the adjustment of relative and not absolute parameters like most methods. We quantified the influence of these parameters on architectural measurements. Results were first validated by using a physical phantom and then examined on a series of 12 HRCT images of human lumbar vertebra of different ages. We demonstrated that the choice of segmentation parameters yielded important variability on architectural measurements (up to 20%), but less variability than a more commonly used approach. This stresses the importance of settle on the segmentation parameters for once, which is possible with the proposed method.

Adult↗

Development of separable electron spin resonance-computed tomography imaging for multiple radical species: an application to .OH and .NO.

A method of separable ESR-CT (electron spin resonance-computed tomography) imaging for multiple radical species was developed and applied to imaging of .OH and .NO. The algorithm was improved by combining filtered back-projection with a modified algebraic reconstruction technique to enhance accuracy and shorten calculation time. With this algorithm, spectral-spatial images of the phantom consisting of 3-carbamoyl-2,2,5,5,-tetramethylpyrrolidine-N-oxyl and 2-phenyl-4,4,5,5,-tetramethylimidazoline-3-oxide-1-oxyl could be obtained in different directions by rotating the spatial axis. The spatial function of individual radicals was extracted by each of the two methods from each spectral-spatial image. The separative 2D images of each radical were individually constructed using the spatial function obtained with the two methods. By comparing the separative images with the phantom sample, the algorithm for separable ESR-CT imaging was established. This ESR-CT technique was combined with L-band ESR spectroscopy and applied to the separative imaging of .OH and .NO, which were spin trapped with 5, 5-dimethyl-1-pyrroline-N-oxide (DMPO) and Fe(2+)-N-methyl-D-glucamine dithiocarbamate complex, respectively. The ESR signal of DMPO-OH decreased gradually during data acquisition, and the decrease was calibrated by extrapolating the signal intensity to the beginning of data sampling. Both the position and size of the individual images for .OH and .NO were in very good agreement with the findings for the sample.

Cyclic N-Oxides↗

Carpal bone anatomy measured by computer analysis of three-dimensional reconstructions of computed tomography images.

Using quantitative analysis of three-dimensional reconstructions of computed tomography scan data, a normative database of carpal bone morphology was built. Thirty-five wrists were imaged in a computed tomography scanner. Each slice was processed to determine the bone edges and assembled as a three-dimensional model by stacking. Quantitative measurements of volume, surface area, maximum length, and intercarpal distances were then assessed. A reliable three-dimensional carpal height ratio was calculated by dividing the carpal height (minimum distance between the fourth metacarpal and the radius) by the capitate maximum length. For volume, maximum length, and surface area, the order for the eight carpal bones with respect to size (in descending order) were: capitate, hamate, scaphoid, trapezium, lunate, trapezoid, triquetrum, and pisiform. Male wrists were significantly larger than female wrists. There were no significant differences in the relative dimensions between left and right wrists, or between left and right wrists of matched pairs. This technology offers automated analysis of three-dimensional geometric carpal information and the opportunity to obtain a body of information about normal and abnormal morphology as well as spatial relationships between carpal bones.

Adolescent↗

Optimal computed tomography imaging of the midfoot: an improved technique.

A new protocol for computed tomography (CT) imaging of the midfoot is described. This imaging technique places the CT cuts parallel to and perpendicular to the talus-first metatarsal axis, as viewed on the lateral CT scout image. For imaging the midfoot, this technique is an improvement over previously described hindfoot or midfoot protocols.

Clinical Protocols↗

Use of reconstructed sagittal computed tomography images to plan middle cranial fossa surgery.

OBJECTIVE: To facilitate planning in temporal bone surgery for the middle cranial fossa approach by using sagittal reconstructed temporal bone computed tomography images. STUDY DESIGN: Comparison of anatomic measurements on random high-resolution, reformatted computed tomography scans of the temporal bone. METHODS: High-resolution computed tomography of 10 normal temporal bones in the axial and coronal planes was obtained, and two-dimensional sagittal reconstructions were performed using a commercial software program. Eight anatomical relationships between neural and/or vascular structures were measured. Representative images were inverted to recreate the plane of the middle cranial fossa approach. RESULTS: Anatomical relationships among the vestibule, superior semicircular canal, internal auditory canal, internal carotid artery, and middle cranial fossa exhibited a high SD in the 10 subjects. The sample size and the large range for the eight anatomical relationships precluded the detection of a significant difference between right and left temporal bones or sex and age of the patient. CONCLUSION: The present report presents a novel, practical measurement protocol for rapidly evaluating important individual anatomical differences in patients before middle cranial fossa surgery. Inverted sagittal reconstructions facilitate presurgical planning for the middle cranial fossa approach by 1) assessing critical anatomical relationships before surgery and 2) providing customized measurements between vital landmarks and the first in vivo measurements. This decreases the likelihood of surgical mishaps and improves teaching by providing the first in vivo measurements of practical anatomical relationships in the sagittal plane.

Adult↗

Cardiac computed tomography imaging: a history and some future possibilities.

Cardiac computed tomography (CT) is a special subset of CT, a subject about which much has been written in terms of the underlying concepts and mathematics and the sociologic impact. Cardiac CT has passed through three, chronologically overlapping, developmental stages and is now in its fourth stage of development. The first stage was fluoroscopy-based CT (1972-1995) stimulated by physiologic research needs, and the next was clinical CT-based exploration (1975-1980) of the potential of clinical CT in cardiology. This was followed by the electron beam CT-based stage (1980-present), which was the first CT approach applicable to clinical cardiology. Finally, volume-scanning CT imaging methods achieved with multislice scanning approaches of helical CT and by flat panel-based CT (1990-present), show great promise for clinically applicable CT of the cardiovascular system.

Animals↗

A new filtering algorithm for medical magnetic resonance and computer tomography images.

Inner views of tubular structures based on computer tomography (CT) and magnetic resonance (MR) data sets may be created by virtual endoscopy. After a preliminary segmentation procedure for selecting the organ to be represented, the virtual endoscopy is a new postprocessing technique using surface or volume rendering of the data sets. In the case of surface rendering, the segmentation is based on a grey level thresholding technique. To avoid artifacts owing to the noise created in the imaging process, and to restore spurious resolution degradations, a robust Wiener filter was applied. This filter working in Fourier space approximates the noise spectrum by a simple function that is proportional to the square root of the signal amplitude. Thus, only points with tiny amplitudes consisting mostly of noise are suppressed. Further artifacts are avoided by the correct selection of the threshold range. Afterwards, the lumen and the inner walls of the tubular structures are well represented and allow one to distinguish between harmless fluctuations and medically significant structures.

Algorithms↗

Efficacy of navigation in skull base surgery using composite computer graphics of magnetic resonance and computed tomography images.

The efficacy of a neurosurgical navigation system using three-dimensional composite computer graphics (CGs) of magnetic resonance (MR) and computed tomography (CT) images was evaluated in skull base surgery. Three-point transformation was used for integration of MR and CT images. MR and CT image data were obtained with three skin markers placed on the patient's scalp. Volume-rendering manipulations of the data produced three-dimensional CGs of the scalp, brain, and lesions from the MR images, and the scalp and skull from the CT. Composite CGs of the scalp, skull, brain, and lesion were created by registering the three markers on the three-dimensional rendered scalp images obtained from MR imaging and CT in the system. This system was used for 14 patients with skull base lesions. Three-point transformation using three-dimensional CGs was easily performed for multimodal registration. Simulation of surgical procedures on composite CGs aided in comprehension of the skull base anatomy and selection of the optimal approaches. Intraoperative navigation aided in determination of actual spatial position in the skull base and the optimal trajectory to the tumor during surgical procedures.

Computer Graphics↗

A comparison between IEEC, a new biodegradable particulate contrast medium, and iohexol in a tumor model of computed tomography imaging of the liver.

RATIONALE AND OBJECTIVES: Higher contrast between normal and pathologic tissues in the liver may enable detection of smaller lesions in computed tomography (CT). This can be obtained using a liver-specific contrast medium. The authors evaluate a new agent, IEEC (1'-Ethyloxycarbonyloxy)-ethyl-5-acetylamino-3-(N-methyl-acetylami no)-2,4,6- triiodo-benzenecarboxylate), in an animal model, as a potential contrast agent for CT scanning of the liver. The IEEC particulate contrast medium used is based on a prodrug ester design of metrizoic acid and accumulates rapidly in the liver. The particles are quickly degraded into well-known metabolites and excreted from the body. METHODS: Two groups of rabbits were inoculated with VX2-carcinoma directly into the liver by laparotomy. Computed tomography imaging studies were carried out 9 and 11 days after the inoculation. The investigation was designed as a crossover study. The first group was imaged both as controls (without contrast medium) and with the particulate contrast medium on the 9th day and with iohexol on the 11th day. The second group was imaged with iohexol on the 9th day and as controls, and with the particulate contrast medium on the 11th day. The contrast medium was administered in a dose of 100 mgI/kg. Iohexol was administered in a dose of 570 mgI/kg according to a standard clinical scheme in use at a radiology department for dynamic CT. Changes in normal liver/lesion contrast and the conspicuity of tumors were assessed. On completion of imaging studies on day 11, all animals were killed. The liver was removed and evaluated for the presence of tumors. RESULTS: At macroscopic inspection, all rabbits were found to have tumors ranging from 2 to 14 mm in diameter. The size and location of the tumors corresponded well with the CT images. In the images where the particulate contrast medium was used, the attenuation in the normal liver parenchyma and the contrast between normal liver and lesion was significantly higher compared with the images where iohexol was used or the controls. For all tumor sizes, the lesion detection capability with the particulate contrast medium was significantly higher compared with iohexol (P < .005) and controls (P < .05). CONCLUSIONS: VX2-carcinoma in rabbit liver is a useful model for studying the efficacy of contrast media in CT imaging. The particulate contrast medium IEEC improved visualization of liver tumors.

Animals↗

General purpose digital display system for computed tomography images.

The authors describe a microprocessor-based digital image display system utilizing a solid-state image memory with a high quality television-type monitor for display of computed tomography images. It is an alternative to a commercially available display system, and offers the potential for research in digital image display. It is now under clinical evaluation. Image input to the stand-alone display system is via 9-track magnetic tape common to almost all CT machines, and it may be programmed to accept digital tapes from any type of CT machine and display them in a common format.

Data Display↗

Automatic determination of minimal cardiac motion phases for computed tomography imaging: initial experience.

Low motion phases for cardiac computed tomography reconstructions are currently detected manually in a user-dependent selection process which is often time consuming and suboptimal. The concept of motion maps was recently introduced to achieve automatic phase selection. This pilot study compared the accuracy of motion-map phase selection to that with manual iterative selection. The study included 20 patients, consisting of one group with low and one with high heart rate. The technique automatically derives a motion strength function between multiple low-resolution reconstructions through the cardiac cycle, with periods of lowest difference between neighboring phases indicating minimal cardiac motion. A high level of agreement was found for phase selection achieved with the motion map approach compared with the manual iterative selection process. The motion maps allowed automated quiescent phase detection of the cardiac cycle in 85% of cases, with best results at low heart rates and for the left coronary artery. They can also provide additional information such as the presence of breathing artifacts. Motion maps show promise as a rapid off-line tool to automatically detect quiescent cardiac phases in a variety of patients.

Adult↗

Single photon emission computed tomography imaging of brain tumors.

Five radiotracers may be used for single-photon emission computed tomography (SPECT) imaging of brain tumors, namely technetium 99m pertechnetate, iodine-123 amphetamine derivatives, 99mTc-hexamethyl propylene amine oxime (HMPAO), thallium 201, and 123I alpha methyl tyrosine. Of these, pertechnetate may be considered as an "historical" procedure in brain tumors. However, there may be some equivocal cases in computed tomography or magnetic resonance imaging, where this procedure may still be used. In 1981, 123I isopropyl amphetamine was first used in brain tumors. Further studies showed, however, that IMP is not a useful tool for brain imaging in tumorous lesions. In 1986, 99mTc HMPAO appeared on the European market as a new tumor imaging agent. Some useful clinical results were obtained in patients before and after chemotherapy or radiotherapy. Thallium-201 was incidentally noted to accumulate in tumors. Using a threshold index, this agent can be used to distinguish low-versus high-grade lesions. The most promising agent for brain tumor SPECT is 123I-alpha methyl tyrosine, which shows potential to evaluate therapeutic procedures in brain tumors and may improve the differentiation between abscess and glioblastoma. The most promising aspect is the differentiation of tumor recurrences and scar tissue after brain surgery.

Brain Neoplasms↗