PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “needle”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

[Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy].

PURPOSE: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. MATERIAL AND METHODS: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall accessibility as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). RESULTS: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of - 0.05 (95 % confidence interval [- 0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p = 0.001) but fewer crush artifacts (p = 0.022) while the accessibility did not differ significantly between the two needle types (p = 0.064). There was also no significant difference in the calculated areas of the tissue cores (p = 0.236). According to the different calibers of the biopsy needles, the lengths (p = 0.008) and widths (p = 0.000) of the biopsy specimens differed significantly. CONCLUSIONS: The core biopsy specimens obtained with an MR-compatible 16G titanium alloy biopsy needle are of the same histopathologic quality as specimens obtained with a ferromagnetic 18G stainless steel needle.

Aged↗

Core needle biopsy of palpable breast lump: the influence of needle size.

The diagnostic value of core needle biopsy is increasingly being preferred because of its better characterization of benign and malignant lesions and lower frequency of insufficient samples. The aim of this study was to determine the diagnostic accuracy and complication rates with 2 different gauges of core biopsy needle in the preoperative diagnosis of palpable breast lumps. A total of 150 consecutive core biopsies were included in this prospective non-randomised study of palpable breast lump from May 2000 to May 2001. The tissue diagnosis made from the core biopsy specimen was compared with the final histopathology reports from the excised specimen. However, if the lump is not excised, a presumptive diagnosis of benign lesion was made only after at least 6 months follow up with no change in the breast lump. The data were analysed for sensitivity, specificity, predictive values, diagnostic accuracy and complications. The results from the 2 different sizes of core needle biopsies were compared accordingly and a statistical analysis was performed using Chi-squared test. Ninety-six core specimens were acquired with 14 G needle while the other 54 with 16 G needle. There was no significant statistical difference between the accuracy of both needle sizes. However, 4 complications occurred with the larger size 14 G needle while none with the 16 G needle, but this was not statistically significant. In conclusion the size 16 G core biopsy needle provided an accurate diagnostic reliability that is comparable to the larger size 14 G needle in the preoperative diagnosis of palpable breast lump.

Adult↗

A prospective crossover comparison study of the single-needle and multiple-needle techniques for facet-joint medial branch block.

BACKGROUND AND OBJECTIVES: Medial branch blocks have been widely described in the literature as a diagnostic tool for facet joint pain. Recently, a new "single-needle' technique was described that is purported to be equally accurate, and in some respects, superior to the standard multiple-needle technique. To date, no studies have been performed that compared these 2 techniques. METHODS: In a multicenter setting, 24 subjects underwent 2 separate diagnostic medial-branch blocks in a randomized, single-blind crossover comparison of the single-needle and multiple-needle techniques. Multiple variables were compared between the 2 techniques, including procedure-related discomfort, post-procedure pain relief, volume of local anesthetic required, accuracy as determined by final needle position and contrast-media spread, and time needed to perform the procedure. RESULTS: In this pilot study, the single-needle technique resulted in less procedure-related pain (P = .0003), required less superficial local anesthesia (P =.0006), and took less time to complete (P < .0001) than did the multiple-needle approach. With regard to final needle position, contrast spread, and post-procedure pain relief (P = .8), no differences were noted between the 2 techniques. CONCLUSIONS: Our results indicate that the single-needle technique takes less time to perform and causes less patient discomfort than does the standard technique but provides the same degree of accuracy. More studies with larger sample sizes are needed to corroborate these results and explore the effect the single-needle approach has on the rate of false-positive medial branch blocks.

Anesthesia, Spinal↗

Thyroid biopsies: fine-needle aspiration biopsy versus spring-activated core biopsy needle in 102 patients.

PURPOSE: Use of the single-action spring-activated core biopsy needle was compared with the fine needle aspiration biopsy (FNAB) technique in ultrasound (US)-guided thyroid biopsies. PATIENTS AND METHODS: Results in 102 patients who underwent sonographically guided thyroid biopsies with both fine needles and core biopsy needles were prospectively evaluated. Results from the 21-gauge FNAB (n = 102) were compared with results from 18-gauge (n = 1), 19-gauge (n = 2), 20-gauge (n = 43), or 21-gauge (n = 56) single-action spring-activated core biopsy needles. RESULTS: If the suggestive and diagnostic results were combined, the diagnostic accuracy for the core biopsy needle was 90.2% (92 of 102) and was 80.3% (82 of 102) for FNAB (P = .048). The diagnostic accuracy for the combination of both needles was 97.1% (99 of 102). The complication rate was 0.98% (n = 1). This complication was a minor soft-tissue infection successfully treated with orally administered antibiotics. CONCLUSION: In summary, sonographically guided biopsies of the thyroid performed with single-action core biopsy needles are safe and effective. The results with use of these needles are better than the results of FNAB, but the best results are obtained when both needles are used in the same patient.

Adult↗

Difficulties in spinal needle use. Insertion characteristics and failure rates associated with 25-, 27- and 29-gauge Quincke-type spinal needles.

The effect of different size (25-, 27- and 29-gauge) Quincke-type spinal needles on the incidence of insertion difficulties and failure rates was investigated in a randomised, prospective study with 300 patients. The needle size was randomised but the insertion procedure was standardised. The time to achieve dural puncture was significantly longer with the 29-gauge spinal needle compared with the larger bore needles and was due to the greater flexibility of the thin needle. However, the difference was less than 1 min and cannot be considered clinically significant. There were no significant differences between groups in the number of insertion attempts or failures and the same sensory level of analgesia was reached with all the needle sizes studied. Postoperatively, no postdural puncture headaches occurred in the 29-gauge spinal needle group, whilst in the 25- and 27-gauge needle groups, the postdural puncture headache rates were 7.4% and 2.1% respectively. The incidence of backache was similar in all study groups. We conclude that dural puncture with a 29-gauge spinal needle is clinically as easy as with larger bore needles and its use is indicated in patients who have a high risk of postdural puncture headache.

Adult↗

Retrobulbar anesthesia risk. Do sharp needles really perforate the eye more easily than blunt needles?

PURPOSE: Conventional wisdom in ophthalmology is that the force required to perforate an eye during retrobulbar injection is noticeably greater with a specially designed blunt needle than with a standard hypodermic needle. A search of the literature showed no measurements of scleral perforation pressure with specific needle tips. The authors investigated this concept. METHODS: A computerized search for eye perforations of the surgical records over a 5-year period at Wilford Hall United States Air Force Medical Center was conducted. A double-masked trial by experienced ophthalmologists, using preserved eye bank eyes and several commercially available needles, subjectively assessed the force required to perforate the globe. The authors designed and built a portable transducer system to objectively measure the perforation pressure of human globes with the needles. Measurements were done with preserved and unpreserved human cadaver eyes. RESULTS: No globe penetrations or perforations were found in this consecutive series of over 4000 retrobulbar anesthesia procedures. A subjective difference between the hypodermic and blunt needles was detected. Objective measurements showed a significant difference between the hypodermic and blunt needles, and between types of blunt needles. The difference was present with both eye bank eyes and fresh cadaver eyes. CONCLUSIONS: Blunt-tipped needles do require greater force to penetrate the eye. The noncutting edge, blunt-tipped needles have higher scleral perforation pressures than those with cutting edges.

Anesthesia, Local↗

A clinical comparison between needle-through-needle and double-segment techniques for combined spinal and epidural anesthesia.

BACKGROUND AND OBJECTIVES: The goal of the present investigation was to compare the double-segment and the needle-through-needle techniques for combined spinal and epidural anesthesia (CSE) in a prospective, randomized, blinded study. METHODS: With Ethical Committee approval and patient's consent, 120 patients were randomized to receive CSE by the needle-through-needle (SST; n=60) or the double-segment technique (DST; n=60). A blind observer measured the time required from skin disinfection to readiness for surgery (loss of pinprick sensation up to T10), failure of dural puncture, need for epidural top-up before surgery, patient acceptance, and occurrence of complications. RESULTS: No neurologic complications were observed in either group. Time to readiness for surgery was 22.7+/-8.2 minutes in the SST group and 29.8+/-8.31 minutes in the DST one (P < .001). Dural puncture was unsuccessful in three patients in the SST group (5%) and in one patient in the DST group (1.6%) (ns); inadequate spread of spinal anesthesia was observed in five patients in the SST group (8.3%) and in eight patients in the DST group (13.3%) (ns). No difference in the incidence of hypotension, postdural puncture headache, and back pain was observed between the two groups. Acceptance of anesthetic procedure was better in the SST (85%) than in the DST group (66.6%) (P < .05). CONCLUSIONS: The needle-through-needle technique for CSE requires less time, has no greater failure rate, and results in greater patient satisfaction than the double-segment technique. The use of a spinal needle with an adjustable locking mechanism and protruding up to 15 mm beyond the Tuohy needle improved successful spinal block in the needle-through-needle technique compared with previous reports.

Anesthesia, Epidural↗

Treatment of fibromyalgia with formula acupuncture: investigation of needle placement, needle stimulation, and treatment frequency.

OBJECTIVES: The objective of this study was to investigate whether typical acupuncture methods such as needle placement, needle stimulation, and treatment frequency were important factors in fibromyalgia symptom improvement. DESIGN/SETTINGS/SUBJECTS: A single-site, single-blind, randomized trial of 114 participants diagnosed with fibromyalgia for at least 1 year was performed. INTERVENTION: Participants were randomized to one of four treatment groups: (1) T/S needles placed in traditional sites with manual needle stimulation (n = 29): (2) T/0 traditional needle location without stimulation (n = 30); (3) N/S needles inserted in nontraditional locations that were not thought to be acupuncture sites, with stimulation (n = 28); and (4) N/0 nontraditional needle location without stimulation (n = 2 7). All groups received treatment once weekly, followed by twice weekly, and finally three times weekly, for a total of 18 treatments. Each increase in frequency was separated by a 2-week washout period. OUTCOME MEASURES: Pain was assessed by a numerical rating scale, fatigue by the Multi-dimensional Fatigue Inventory, and physical function by the Short Form-36. RESULTS: Overall pain improvement was noted with 25%-35% of subjects having a clinically significant decrease in pain; however this was not dependent upon "correct" needle stimulation (t = 1.03; p = 0.307) or location (t = 0.76; p = 0.450). An overall dose effect of treatment was observed, with three sessions weekly providing more analgesia than sessions once weekly (t = 2.10; p = 0.039). Among treatment responders, improvements in pain, fatigue, and physical function were highly codependent (all p < or = 0.002). CONCLUSIONS: Although needle insertion led to analgesia and improvement in other somatic symptoms, correct needle location and stimulation were not crucial.

Acupuncture Analgesia↗

[Comparison of therapeutic effects between normal acupuncture and shallow needling with short-needle on periarthritis of shoulder].

OBJECTIVE: To compare therapeutic effects between normal acupuncture and shallow needling with short-needle, and search for therapeutic tool and method easy to be accepted by the patient of periarthritis of shoulder. METHODS: One hundred and fifty-two cases of periarthritis of shoulder were randomly divided into 2 groups. They were treated by normal acupuncture and shallow needling with short-needle, respectively. The two groups were same in acupoints selected and the therapeutic course, and their therapeutic effects and the accepting degrees of the patient were investigated. RESULTS: The cured rate was 67.1% in the normal acupuncture group and 69.7% in the shallow needling with short-needle group, with no significant difference between the two groups (P>0.05). CONCLUSION: Normal acupuncture and shallow needling with short-needle have similar therapeutic effect on periarthritis of shoulder, but the shallow needling with short-needle can obviously relieve the pain and mental fear in treatment, easy to be accepted.

Acupuncture Therapy↗

Endoscopic needle biopsy: a comparative study of forceps biopsy, two different types of needles, and salvage cytology in gastrointestinal cancer.

One of the goals of gastrointestinal endoscopy is to diagnose whether a lesion is malignant. The desire to improve the sensitivity of biopsy-sampling techniques prompted us to compare prospectively the reliability and accuracy of obtaining tissue by forceps biopsy, needle biopsy (21 gauge 13-mm long metal needles versus 18 gauge 20-mm long plastic needles), and salvage cytology in patients with endoscopically suspected malignancy. Samples were obtained in the order of needle biopsy (the order of metal and plastic needle biopsy was randomized), forceps biopsy, followed by salvage cytology. Needle biopsies were obtained by puncturing the lesion under direct vision while aspirating with a syringe. Twenty-three patients with gastrointestinal malignancy were studied (7 esophageal, 4 gastric, and 12 colonic). Forceps biopsies were positive in 18 of 23 (78%), missing 1 gastric and 4 colon malignancies. Metal needle biopsy was positive in 16 of 19 (84%), plastic needle biopsy in 17 of 22 (77%), and salvage cytology in 20 of 22 (91%). Accuracy was increased by a combination of techniques. Endoscopic needle biopsy is a simple and rapid method to evaluate lesions seen at endoscopy and is especially useful in evaluation of submucosal lesions.

Biopsy, Needle↗

Evaluation of needle size for breast biopsy: comparison of 14-, 16-, and 18-gauge biopsy needles.

OBJECTIVE: The purpose of our study was to compare the quantity and quality of tissue harvested from breast biopsy when using 14-, 16-, and 18-gauge "long-throw" needles. SUBJECTS AND METHODS: We performed a prospective randomized study in 64 patients with 66 breast lesions. Under stereotactic guidance, passes were made in random order with each of the three biopsy needles in each lesion. Samples were measured for tissue area and scored for their quality. All lesions, including benign and malignant lesions and lesions with and without microcalcifications, were analyzed. Findings of the biopsy samples were compared with the final diagnoses made at surgical excision. RESULTS: In all 66 lesions, 14-gauge biopsy needles obtained significantly larger specimens (14-gauge, 13.14 mm2; 16-gauge, 9.6 mm2; 18-gauge, 6.41 mm2; p < .05) and scored significantly better (14-gauge, 8.37; 16-gauge, 7.56; 18-gauge, 7.14; p < .016) than either of the smaller needles. The results for malignant and benign lesions and for lesions with and without microcalcifications were similar but not equal to the overall results. However, benign lesions and areas with microcalcifications seem to be more problematic for both smaller needles than for 14-gauge needles. CONCLUSION: Our results indicate that the quantity and quality of breast biopsy specimens depend on the needle size. Of the three needle sizes tested, only 14-gauge long-throw biopsy needles can be recommended for breast biopsy.

Biopsy, Needle↗

Needle tract implantation of hepatocellular carcinoma after fine needle biopsy.

The reported incidence of needle tract implantation of hepatocellular carcinoma after fine needle biopsy ranges from 1 to 5%. We collected five cases of hepatocellular carcinoma with needle tract implantation after percutaneous biopsy and tried to determine how this complication affects the clinical outcome. From September 1997 to May 2002, five patients with needle tract implantation of hepatocellular carcinoma were managed in our institution. For treatment of the primary hepatocellular carcinoma, three patients underwent hepatectomy, one had transarterial chemoembolization, and in one patient peritoneal seeding in the needle tract precluded curative resection. All three hepatectomy patients were detected to have tumor implants in the needle tract at an interval of 39 to 58 months after biopsy. These implants were managed with wide surgical excision. Local control was achieved in two patients after repeat resection, whereas the third developed pulmonary metastasis. Thus, in two of five patients, tract implantation after fine needle biopsy changed a potentially curative disease into an untreatable situation. Because of the risk of tumor implantation in the needle tract, we support a policy of selective use of fine needle biopsy for the definitive diagnosis of liver lesions. The patients who do need a biopsy should be carefully followed up for early detection of implanted tumor and its recurrence after resection.

Aged↗

Installing needle disposal boxes closer to the bedside reduces needle-recapping rates in hospital units.

OBJECTIVE: To compare the proportion of recapped needles, an injury surrogate measure, in disposal boxes on two different types of hospital units, both before and after an intervention. DESIGN: Prospective nonrandomized intervention trial. SETTING: A major public teaching hospital. PARTICIPANTS: Specific hospital units. We selected two types of hospital units for study: the first type of hospital unit (medical-surgical ward) had existing mounted in-bathroom needle disposal boxes, and the second type of hospital unit (intensive care unit) had unmounted needle disposal boxes in the room but not necessarily near the patient's bedside. INTERVENTION: The installation, in the medical-surgical wards only, of mounted needle disposal boxes on the wall near the patient's bed. The box location in the intensive care units remained the same. In both types of unit, a new mailbox-slot disposal box (SAGE) also was substituted for the previous round-top container. RESULTS: The baseline proportion of recapped needles in the first medical-surgical unit was 32.6% (+/- 3.8%) and in the second medical-surgical unit it was 27.4% (+/- 4.0%) in the bathroom needle disposal boxes, which was similar to the observed proportion (34.7 +/- 6.4%) in the intensive care unit boxes. Following the intervention, the proportion of recapped needles was significantly reduced in the disposal containers adjacent to the bedside in medical-surgical units, to 27% (a difference of 2.9 standard errors of the baseline distribution) in the first unit and 18.2% (a difference of 4.6 standard errors) in the second. In the intensive care unit, where boxes were not moved but new mailbox-types were simply substituted, no significant change was noted (36.6%, a difference of 0.59 standard errors). A statistically significant reduction was observed in the proportion of needles recapped in both wards combined following the intervention (30.2% to 26.2%, a difference of 2.9 standard errors). CONCLUSION: Environmental changes alone are an effective means of altering the risk to healthcare workers from sharp instruments. The use of needle-box counts provides a sensitive and stable instrument to measure injury surrogates and, indirectly, behavioral change in hospital workers.

Accidents, Occupational↗

Single-needle celiac plexus block: is needle tip position critical in patients with no regional anatomic distortions?

BACKGROUND: The "single-needle" celiac plexus block is becoming a popular technique. Despite different approaches and methods used to place the needle, the success of the block depends on adequate spread of the injectate in the celiac area. In the present retrospective study, the influence of needle tip position in relation to the celiac artery on injectate spread was evaluated. METHODS: Among 138 cancer patients subjected, via an anterior approach, to computed tomography (CT)-guided single-needle neurolytic celiac plexus block, a radiologist, blinded to the aim of the study, retrospectively selected 53 cases with normal anatomy of the celiac area as judged by CT. The decision was based on images obtained before the block. Patients were then classified into either group A (29 patients), in whom the needle tip was caudad to the celiac artery, and group B (24 patients), in whom it was cephalad. To evaluate CT patterns of neurolytic (mixed with contrast) spread, the celiac area was divided on the frontal plane into four quadrants: upper right and left and lower right and left, as related to the celiac artery. Patient assessments by visual analog scale were reviewed to evaluate the degree of pain relief. Pain relief 30 days after block was judged as long-lasting. The patterns of contrast spread in relation to the needle position and pain relief according to the number of quadrants with contrast were analyzed. RESULTS: The percentage of cases with four quadrants with contrast was higher when the needle tip was cephalad (58%, group B) than when it was caudad (14%, group A) to the celiac artery (P < 0.01). The percentage of patients with four and three quadrants with contrast was also higher in group B at 79% than in group A at 38% (P < 0.01). A significant difference in long-lasting pain relief was observed between patients with four quadrants with contrast (18 of 18, 100%; 95% confidence interval [CI], 81-100%) and patients with three quadrants with contrast (5 of 12, 42%; 95% CI, 15-72%) (P < 0.01). No patients showing two or one quadrant with contrast had long-lasting pain relief. CONCLUSIONS: These findings suggest that, when the celiac area is free from anatomic distortions, and the single-needle neurolytic celiac plexus block technique is used, the needle tip should be positioned cephalad to the celiac artery to achieve a wider neurolytic spread. It also appears that only a complete (four quadrants) neurolytic spread in the celiac area can guarantee long-lasting analgesia.

Adult↗

Needle-use practices among intravenous drug users in an area where needle purchase is legal.

Needle-use practices of intravenous drug users (IVDUs) were examined in a region (Seattle, King Country, Washington State, USA) where needle purchase is legal. IVDUs in treatment (n = 313) were administered extensive structured interviews concerning drug and injection equipment-use practices. Of the 80.2% reporting intravenous drug use in the previous year, 78.3% reported sharing needles. Of the 47.7% reporting intravenous use in the previous 30 days, only 40.5% shared needles, with 59.3% sharing with only one other person. Most needle-sharing partners were very well known (63%) or well known (17%) to the subjects. The most frequent method for obtaining needles was 'buying in a drug store', ranked first by 65% of the sample. Subjects whose primary source was 'buying in a drug store' shared equipment less frequently during drug-use events in the previous year (mean: 16.2%) than those with other primary sources (mean: 28.5%). Compared with findings from other regions where needle purchase and possession are illegal without a prescription, fewer subjects in the current investigation shared needles, and those who did shared with a smaller number of people. The apparent association between legalized injection equipment and reduced sharing of equipment among IVDUs should be further examined in longitudinal studies of needle-sharing before and after legalization is instituted.

Adult↗

Is the pencil point spinal needle a better choice in younger patients? A comparison of 24G Sprotte with 27G Quincke needles in an unselected group of general surgical patients below 46 years of age.

Reports have indicated that there are less postoperative complaints after the use of pencil pointed spinal needles. We compared a 24G Sprotte needle with a 27G Quincke needle in a randomised study of 200 healthy patients (49% females), aged 15-46 years. Four patients (2%) reported postdural puncture headache, three with the 24G Sprotte needle and one with the 27G Quincke needle. Thirteen patients (7%) suffered with nonspecific headache, with no significant difference between the two groups. Of the 57 (29%) who reported backpain, a significantly higher proportion had received spinal anaesthesia with the Sprotte needle (OR = 2.06). There was a significantly higher incidence of insufficient blocks after dural puncture with the Sprotte needle. Ease of needle insertion and number of puncture attempts was the same for both needle types.

Adolescent↗

The effect of a needle exchange program on numbers of discarded needles: a 2-year follow-up.

OBJECTIVES: This study estimates the quantity and geographic distribution of discarded needles on the streets of Baltimore, Md, during the 2 years after a needle exchange program opened. METHODS: Thirty-two city blocks were randomly sampled. Counts were taken of the number of syringes, drug vials, and bottles before the needle exchange program opened and then at 6 periodic intervals for 2 years after the program opened. Nonparametric and generalized estimating equation models were used to examine change over time. RESULTS: Two years after the needle exchange program opened, there was a significant decline in the overall quantity of discarded needles relative to that of drug vials and bottles (background trash). The block mean of number of needles per 100 trash items was 2.42 before the program opened and 1.30 2 years later (mean within-block change = -0.028, P < .05). There was no difference in the number of discarded needles by distance from the program site. CONCLUSIONS: These data suggest that this needle exchange program did not increase the number of distribution of discarded needles.

Baltimore↗