The use of cytodex microcarrier beads in patch-clamp studies on cultured epithelial cells.

This paper describes an economical attachment substratum for use in patch-clamp experiments on cultured epithelial cells. It consists of Cytodex microcarrier beads on which growing cells present a unique profile perspective that increases the ease with which patch-clamp seals can be obtained. Cells from the mouse mandibular gland cell line, ST885, were grown on the beads and studied using standard patch-clamp techniques. The results were indistinguishable from those obtained from cells grown in monolayers on Petri dishes. The method can be applied in many types of patch-clamp experiment and used with a wide variety of cell types. It is especially useful if one wishes to do experiments in the cell-attached or whole-cell configurations and needs to add drugs or hormones to the external surface of the cell.

Animals↗

Patch-clamping of primary cardiac cells with micro-openings in polyimide films.

Patch-clamping is a powerful method for investigating the function and regulation of ionic channels. Currently, great efforts are being made to automate this method. As a step towards this goal, the feasibility of patch-clamping primary cells with a microscopic opening in a planar substrate was tested. Using standard microfabrication and ion beam technology, small-diameter openings (2 and 4 microm) were formed in polyimide films (thickness 6.5 microm). Single cells (sheep Purkinje heart cells, Chinese hamster ovary cells) in a suspension were positioned on top of the opening and sucked towards the opening to improve adhesion of the cell to the planar substrate, hence increasing the seal resistance. Voltage/current measurements yielded a median seal resistance of 1.3 Mohms with 4 microm openings (n=24) and 26.0 Mohms with 2 microm openings (n = 75), respectively. With 2 microm openings, successful loose-patch recordings of TTX-sensitive inward currents and action potentials in sheep Purkinje heart cells (n = 18) were made. In rare cases, gigaseals (n = 4) were also measured, and a whole-cell configuration (n = 1) could be established. It was concluded that the simple planar patch approach is suitable for automated loose-patch recordings from cells in suspension but will hardly be suitable for high-throughput whole-cell patch-clamping with high-resistance seals.

Animals↗

Cell marking in Arabidopsis thaliana and its application to patch-clamp studies.

Ion transport processes at the plasma membrane of plant cells are frequently studied by applying membrane-patch voltage-clamp (patch-clamp) electrophysiological techniques to isolated protoplasts. As plants are composed of many tissues and cell types, and each tissue and cell type may be specialized to a particular function and possess a unique complement of transport proteins, it is important to certify the anatomical origin of the protoplasts used for patch-clamp studies. This paper describes a general molecular genetic approach to marking specific cell types for subsequent patch-clamp studies and presents a specific example: a comparison of the K+ currents in protoplasts from cortical and stelar cells of Arabidopsis roots. Transgenic Arabidopsis were generated in which the expression of green fluorescent protein (GFP) from Aequoria victoria was driven by the CaMV 35S promoter (line mGFP3). In roots of the transgenic mGFP3 line, visible fluorescence was restricted to the stele. Protoplasts were generated from roots of the mGFP3 line and K+ currents in non-fluorescent (cortical/epidermal) and fluorescent (stelar) protoplasts were assayed using patch-clamp techniques. It was found that both the frequency of observing inward rectifying K+ channel (IRC) activity and the relative occurrence of IRC compared to outward rectifying K+ channels were significantly lower in protoplasts from cortical/epidermal cells compared to cells of the stele. The presence of GFP did not affect the occurrence or biophysical properties of K+ channels. It is concluded that the generation of transgenic Arabidopsis expressing GFP in a cell-specific fashion is a convenient and reliable way to mark protoplasts derived from contrasting cell types for subsequent patch-clamp studies.

Arabidopsis↗

A thin slice preparation for patch clamp recordings from neurones of the mammalian central nervous system.

(1) A preparation is described which allows patch clamp recordings to be made on mammalian central nervous system (CNS) neurones in situ. (2) A vibrating tissue slicer was used to cut thin slices in which individual neurones could be identified visually. Localized cleaning of cell somata with physiological saline freed the cell membrane, allowing the formation of a high resistance seal between the membrane and the patch pipette. (3) The various configurations of the patch clamp technique were used to demonstrate recording of membrane potential, whole cell currents and single channel currents from neurones and isolated patches. (4) The patch clamp technique was used to record from neurones filled with fluorescent dyes. Staining was achieved by filling cells during recording or by previous retrograde labelling. (5) Thin slice cleaning and patch clamp techniques were shown to be applicable to the spinal cord and almost any brain region and to various species. These techniques are also applicable to animals of a wide variety of postnatal ages, from newborn to adult.

Animals↗

Combining patch-clamp and optical methods in brain slices.

Combining patch-clamp and optical imaging techniques in brain slices offers several advantages for physiological studies of nerve cells. Numerous practical considerations weigh heavily in this design of an apparatus suitable for such combined measurements. These considerations include the thickness of the slices, the type of microscope to be used for imaging and the kind of optical signal to be measured. A system that combine optical and patch-clamp methods can be modified readily to permit studies of intracellular and extracellular signaling pathways via flash photolysis of caged compounds.

Animals↗

Control of ion channel expression for patch clamp recordings using an inducible expression system in mammalian cell lines.

BACKGROUND: Many molecular studies of ion channel function rely on the ability to obtain high quality voltage clamp recordings using the patch clamp technique. For a variety of channel types studied in mammalian cell heterologous expression systems, the lack of experimenter control over expression levels severely hinders the ability to obtain a high percentage of cells with an expression level suitable for high quality recordings. Moreover, it has been nearly impossible to obtain expression levels in mammalian cells well suited for single channel recordings. We describe here the use of an inducible promoter system in a stably transfected mammalian cell line that produces nearly 100% success in obtaining ion channel expression levels suitable for either whole cell or single ion channel studies. RESULTS: We used a tetracycline-regulated expression system to control K+ channel expression in a CHO (Chinese hamster ovary) cell line. Current magnitudes within a reasonably narrow range could be easily and reliably obtained for either macroscopic or single channel recordings. Macroscopic currents of 1-2 nA could be obtained in nearly 100% of cells tested. The desired expression level could be obtained within just 2 to 3 hours, and remained stable at room temperature. Very low expression levels of transfected channels could also be obtained, which resulted in a >70% success rate in the ability to record single channel currents from a patch. Moreover, at these low expression levels, it appeared that endogenous channels produced little or no contamination. CONCLUSION: This approach to controlling ion channel expression is relatively simple, greatly enhances the speed and efficiency with which high quality macroscopic current data can be collected, and makes it possible to easily and reliably record single channel currents in a mammalian cell heterologous expression system. Whereas we demonstrate the ability of this system to control expression levels of voltage-gated K+ channels, it should be applicable to all other channel types that express well in mammalian expression systems.

Animals↗

[Patch-clamp methods in research on the kidney tubules].

Patch-clamp studies in renal tubule cell have been very helpful in increasing our understanding of the tubule transport function. However, it has been a disappointing experience that the properties of cultured cells deviate grossly from the physiology of the intact tubule segment. Also, several important conductive pathways have not been characterized thus far on single channel level. Several ion channels, which have been found in the patch-clamp studies, such as the non-selective cation channel, do not find their equivalent in the intact tubule preparation. Therefore, much more efforts are required not only to characterize individual ion channels, but rather to integrate this knowledge for the understanding of tubule function.

Animals↗

Whole cell patch clamp recording performed on a planar glass chip.

The state of the art technology for the study of ion channels is the patch clamp technique. Ion channels mediate electrical current flow, have crucial roles in cellular physiology, and are important drug targets. The most popular (whole cell) variant of the technique detects the ensemble current over the entire cell membrane. Patch clamping is still a laborious process, requiring a skilled experimenter to micromanipulate a glass pipette under a microscope to record from one cell at a time. Here we report on a planar, microstructured quartz chip for whole cell patch clamp measurements without micromanipulation or visual control. A quartz substrate of 200 microm thickness is perforated by wet etching techniques resulting in apertures with diameters of approximately 1 microm. The apertures replace the tip of glass pipettes commonly used for patch clamp recording. Cells are positioned onto the apertures from suspension by application of suction. Whole cell recordings from different cell types (CHO, N1E-115 neuroblastoma) are performed with microstructured chips studying K(+) channels and voltage gated Ca(2+) channels.

Animals↗

Patch-clamp-induced perturbations of [Ca(2+)](i) activity in somatotropes.

Somatotropes and GC cells, a GH-producing cell line, exhibit [Ca(2+)](i) oscillations that result from rhythmic Ca(2+) action potentials. Determination of this operating mode required simultaneous recording of both parameters by fura-2 imaging and patch-clamp techniques. In order to test whether patch recording induces artificial alteration of the [Ca(2+)](i) oscillatory pattern, we recorded separately or simultaneously [Ca(2+)](i) and membrane potential. In the absence of any other stimulation, seal formation in patch-clamp recording evoked by itself a 2.5- to 4-fold persistent increase in basal [Ca(2+)](i), speeded up their frequency (from 0.03-0.17 to 0.4 Hz) and changed their pattern to a tonic mode. Patch-induced [Ca(2+)](i) increase was reproduced by mechanical contact between the pipette and the membrane. It was reduced by nifedipine, a blocker of L-type Ca(2+) channels, as well as by removal of external Na(+). It was fully blocked by external Ca(2+) removal or gadolinium. All patch-clamp-induced perturbations were reversed by membrane hyperpolarization. We propose that patch-clamp recording evokes Ca(2+) entry through L-type Ca(2+) channels either directly, or indirectly via membrane depolarization. This shows that patch recordings in endocrine cells showing mechanosensitivity have to be interpreted with caution, and explains why long-lasting patch recordings are so difficult to obtain.

Animals↗

Pharmacological characterization of the P2X(7) receptor on human macrophages using the patch-clamp technique.

Whole-cell patch-clamp recordings were made from macrophages derived from human monocytes that had been cultured for 5-7 days. The P2X agonists ATP (100 microM) and 2',3'-(4-benzoyl)-benzoyl ATP (BzATP, 100 microM) induced inward currents. A second application of the agonists was characterized by strong desensitisation of the maximum current. Pyridoxal phosphate-6-azophenyl-2',4'-disulphonic acid (PPADS), a non-specific P2X antagonist, and 1-( N, O- bis[5-isoquinolinesulphonyl]- N-methyl- L-tyrosyl)-4-phenylpiperazine (KN62), a potent P2X(7) antagonist at the human receptor, both reduced the ATP-induced inward current. KN62 also inhibited the BzATP-induced current. The P2X(7) antagonist Coomassie Brilliant Blue G (BBG), believed to be potent at the human but even more so potent at the rat receptor, did not reduce the BzATP-induced inward current significantly. These results indicate that the native P2X(7) receptor subtype is expressed in human macrophages and that this receptor subtype is involved in the ATP-mediated inward current. Our experiments suggest that other P2X receptors also appear to be involved in the ATP-mediated current in human monocyte-derived macrophages.

1-(5-Isoquinolinesulfonyl)-2-Methylpiperazine↗

[Current status of the application of patch-clamp technique and its combinations with other techniques].

The Patch-clamp technique, as an advanced electrophysiological technique, has been widely used for research in the life science research field. A recent trend is to combine this technique with other techniques, such as the Fura-2 microfluorimetry for measuring the concentration of Ca2+, electrochemical detection with carbon-fiber electrode (i.e. amperometric detection or amperometry), and single-cell reverse transcription of RNA followed by the polymerase chain reaction (RT-PCR). This article is to summarize the current status of the use of patch-clamp technique and its combinations with other techniques in solving problems related with transmembrane signal transduction in neurobiology.

Animals↗

Characterization of single-cell electroporation by using patch-clamp and fluorescence microscopy.

Electroporation of single NG108-15 cells with carbon-fiber microelectrodes was characterized by patch-clamp recordings and fluorescence microscopy. To minimize adverse capacitive charging effects, the patch-clamp pipette was sealed on the cell at a 90(o) angle with respect to the microelectrodes where the applied potential reaches a minimum. From transmembrane current responses, we determined the electric field strengths necessary for ion-permeable pore formation and investigated the kinetics of pore opening and closing as well as pore open times. From both patch-clamp and fluorescence microscopy experiments, the threshold transmembrane potentials for dielectric breakdown of NG108-15 cells, using 1-ms rectangular waveform pulses, was approximately 250 mV. The electroporation pulse preceded pore formation, and analyte entry into the cells was dictated by concentration, and membrane resting potential driving forces. By stepwise moving a cell out of the focused field while measuring the transmembrane current response during a supramaximal pulse, we show that cells at a distance of approximately 30 microm from the focused field were not permeabilized.

Animals↗

The interpretation of current-clamp recordings in the cell-attached patch-clamp configuration.

In these experiments we have investigated the feasibility and accuracy of recording steady-state and dynamic changes in transmembrane potential noninvasively across an intact cell-attached patch using the current-clamp mode of a conventional patch-clamp amplifier. Using an equivalent circuit mimicking simultaneous whole-cell voltage-clamp and cell-attached current-clamp recordings we have defined both mathematically and experimentally the relationship between the membrane patch resistance, the seal resistance, and the fraction of the whole-cell potential recorded across an intact membrane patch. This analysis revealed a steep increase in the accuracy of recording of steady-state membrane potential as the seal/membrane ratio increases from 0. The recording accuracy approaches 100% as the seal/membrane ratio approaches infinity. Membrane potential measurements across intact cell-attached patches in rat basophilic leukemia cells and rat megakaryocytes revealed a surprisingly high degree of accuracy and demonstrated the ability of this noninvasive technique to follow dynamic changes in potential in nonexcitable cells.

Adenosine Diphosphate↗

Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches.

1. The extracellular patch clamp method, which first allowed the detection of single channel currents in biological membranes, has been further refined to enable higher current resolution, direct membrane patch potential control, and physical isolation of membrane patches. 2. A description of a convenient method for the fabrication of patch recording pipettes is given together with procedures followed to achieve giga-seals i.e. pipette-membrane seals with resistances of 10(9) - 10(11) omega. 3. The basic patch clamp recording circuit, and designs for improved frequency response are described along with the present limitations in recording the currents from single channels. 4. Procedures for preparation and recording from three representative cell types are given. Some properties of single acetylcholine-activated channels in muscle membrane are described to illustrate the improved current and time resolution achieved with giga-seals. 5. A description is given of the various ways that patches of membrane can be physically isolated from cells. This isolation enables the recording of single channel currents with well-defined solutions on both sides of the membrane. Two types of isolated cell-free patch configurations can be formed: an inside-out patch with its cytoplasmic membrane face exposed to the bath solution, and an outside-out patch with its extracellular membrane face exposed to the bath solution. 6. The application of the method for the recording of ionic currents and internal dialysis of small cells is considered. Single channel resolution can be achieved when recording from whole cells, if the cell diameter is small (less than 20 micrometer). 7. The wide range of cell types amenable to giga-seal formation is discussed.

Acetylcholine↗

Novel 384-well population patch clamp electrophysiology assays for Ca2+-activated K+ channels.

Planar array electrophysiology techniques were applied to assays for modulators of recombinant hIK and hSK3 Ca2+-activated K+ channels. In CHO-hIK-expressing cells, under asymmetric K+ gradients, small-molecule channel activators evoked time- and voltage-independent currents characteristic of those previously described by classical patch clamp electrophysiology methods. In single-hole (cell) experiments, the large cell-to-cell heterogeneity in channel expression rendered it difficult to generate activator concentration-response curves. However, in population patch clamp mode, in which signals are averaged from up to 64 cells, well-to-well variation was substantially reduced such that concentration-response curves could be easily constructed. The absolute EC50 values and rank order of potency for a range of activators, including 1-EBIO and DC-EBIO, corresponded well with conventional patch clamp data. Activator responses of hIK and hSK3 channels could be fully and specifically blocked by the selective inhibitors TRAM-34 and apamin, with IC50 values of 0.31 microM and 3 nM, respectively. To demonstrate assay precision and robustness, a test set of 704 compounds was screened in a 384-well format of the hIK assay. All plates had Z' values greater than 0.6, and the statistical cutoff for activity was 8%. Eleven hits (1.6%) were identified from this set, in addition to the randomly spiked wells with known activators. Overall, our findings demonstrate that population patch clamp is a powerful and enabling method for screening Ca2+-activated K+ channels and provides significant advantages over single-cell electrophysiology (IonWorks(HT)) and other previously published approaches. Moreover, this work demonstrates for the 1st time the utility of population patch clamp for ion channel activator assays and for non-voltage-gated ion channels.

Animals↗

Patch-clamp study of the apical membrane of the midgut of Manduca sexta larvae: direct demonstration of endogenous channels and effect of a Bacillus thuringiensis toxin.

The patch-clamp technique was applied to the apical membrane of epithelial midgut cells of a lepidoptera, Manduca sexta L. Access to the apical membrane, the main target site of Bacillus thuringiensis (Bt) toxins, was achieved by using freshly isolated larval midgut preparations mounted onto holding glass pipettes. The epithelial cells retained their functional integrity, as evidenced by the magnitude of intracellular potentials recorded with microelectrodes. With standard 32 mM K(+) solution in the bath and the patch-clamp pipette, endogenous channel activity was detected in about 50% of experiments, mainly in moulting larvae and larvae that had been kept at reduced temperature for at least two days prior to the experiments. In both cell-attached and inside-out patch-clamp configurations, different types of channel were observed, with conductances varying between about 5 and 50 pS and different conducting properties. Addition of trypsin-activated Cry1Ac Bt toxin in the patch-clamp pipette triggered, after a delay, large conductances of a few nanosiemens. This is the first study allowing exploration, in the intact midgut, of the properties of apical membrane channels and the direct interaction between the apical membrane of epithelial cells and pathogenic agents such as Bt toxins.

Animals↗

The patch clamp is more useful than anyone had expected.

The patch clamp was developed into its present form by Neher and Sakmann for recording the currents through individual ionic channels in excitable membranes. Recent advances now allow the patch-clamp technique to be used to record from cell-free membrane patches and from entire small cells. The technique has been used extensively for recordings from single channels that have provided new insights into their functioning; it is also being applied to a surprising variety of other physiological problems.

Animals↗

Bayesian restoration of single-channel patch clamp recordings.

The technique of patch clamp recording makes possible the measurement of current flowing through a single ion channel in a cell membrane. Examination of such recordings suggests that the current is quantal in nature, alternating in a seemingly random manner between "on" and "off," but the recordings are corrupted by noise from a variety of sources. In this paper we propose and illustrate methods for restoring the underlying quantal signal from such noisy measurements. The methods use a Markov chain prior distribution for the underlying quantal process and base the restoration on the resulting posterior distribution.

Algorithms↗