PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “phase space reconstruction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

A Monte Carlo dose calculation tool for radiotherapy treatment planning.

A Monte Carlo user code, MCDOSE, has been developed for radiotherapy treatment planning (RTP) dose calculations. MCDOSE is designed as a dose calculation module suitable for adaptation to host RTP systems. MCDOSE can be used for both conventional photon/electron beam calculation and intensity modulated radiotherapy (IMRT) treatment planning. MCDOSE uses a multiple-source model to reconstruct the treatment beam phase space. Based on Monte Carlo simulated or measured beam data acquired during commissioning, source-model parameters are adjusted through an automated procedure. Beam modifiers such as jaws, physical and dynamic wedges, compensators, blocks, electron cut-outs and bolus are simulated by MCDOSE together with a 3D rectilinear patient geometry model built from CT data. Dose distributions calculated using MCDOSE agreed well with those calculated by the EGS4/DOSXYZ code using different beam set-ups and beam modifiers. Heterogeneity correction factors for layered-lung or layered-bone phantoms as calculated by both codes were consistent with measured data to within 1%. The effect of energy cut-offs for particle transport was investigated. Variance reduction techniques were implemented in MCDOSE to achieve a speedup factor of 10-30 compared to DOSXYZ.

Computer Simulation↗

Adaptive control of unknown unstable steady states of dynamical systems.

A simple adaptive controller based on a low-pass filter to stabilize unstable steady states of dynamical systems is considered. The controller is reference-free; it does not require knowledge of the location of the fixed point in the phase space. A topological limitation similar to that of the delayed feedback controller is discussed. We show that the saddle-type steady states cannot be stabilized by using the conventional low-pass filter. The limitation can be overcome by using an unstable low-pass filter. The use of the controller is demonstrated for several physical models, including the pendulum driven by a constant torque, the Lorenz system, and an electrochemical oscillator. Linear and nonlinear analyses of the models are performed and the problem of the basins of attraction of the stabilized steady states is discussed. The robustness of the controller is demonstrated in experiments and numerical simulations with an electrochemical oscillator, the dissolution of nickel in sulfuric acid; a comparison of the effect of using direct and indirect variables in the control is made. With the use of the controller, all unstable phase-space objects are successfully reconstructed experimentally.

Journal Article↗

Extracting multidimensional phase space topology from periodic orbits.

We establish a hierarchical ordering of periodic orbits in a strongly coupled multidimensional Hamiltonian system. Phase space structures can be reconstructed quantitatively from the knowledge of periodic orbits alone. We illustrate our findings for the hydrogen atom in crossed electric and magnetic fields.

Journal Article↗

Direct imaging of magnetic field gradients by group spin-echo selection.

A new image processing method for single-echo gradient echo imaging is presented which extracts local phase gradient information by k-space filtering instead of by phased reconstruction and spatial differentiation. It is shown that local phase gradient directions and semiquantitative local phase gradient magnitudes can be directly measured, even in regions where phased image reconstruction suffers from multiple phase foldovers due to strong phase modulations. The directional information thus obtained can be used as a reference to identify and correct phase modulation foldovers in phase maps which may be computed from the same raw data. The method is applied here to measure static magnetic field gradients and illustrates fundamental k-space signal properties of gradient echo imaging. Based on this concept, image artifacts caused by conventional strong k-space filtering in gradient echo imaging are discussed.

Artifacts↗

A new technique for fractal analysis applied to human, intracerebrally recorded, ictal electroencephalographic signals.

Application of a new method of fractal analysis to human, intracerebrally recorded, ictal electroencephalographic (EEG) signals is reported. 'Frameshift-Richardson' (FR) analysis involves estimation of fractal dimension (1 < FD < 2) of consecutive, overlapping 10-s epochs of digitised EEG data; it is suggested that this technique offers significant operational advantages over use of algorithms for FD estimation requiring preliminary reconstruction of EEG data in phase space. FR analysis was found to reduce substantially the volume of EEG data, without loss of diagnostically important information concerning onset, propagation and evolution of ictal EEG discharges. Arrhythmic EEG events were correlated with relatively increased FD; rhythmic EEG events with relatively decreased FD. It is proposed that development of this method may lead to: (i) enhanced definition and localisation of initial ictal changes in the EEG presumed due to multi-unit activity; and (ii) synoptic visualisation of long periods of EEG data.

Algorithms↗

A flexible view ordering technique for high-quality real-time 2DFT MR fluoroscopy.

A method to tailor the view order to the reconstruction cycle is introduced for real-time MRI. It is well known that view sharing and oversampling central k-space views can improve the temporal resolution of gradient-echo pulse sequences. By ordering phase-encodes to synchronize k-space acquisition with the reconstruction cycle, apparent temporal resolution can match the frame rate with as few as one-fourth of the phase-encodes sampled per reconstruction. Spatial resolution is maintained by periodically updating high spatial frequencies. In addition to apparent temporal resolution, three other criteria for real-time imaging are identified and evaluated: display latency, dispersion, and frame-to-frame consistency. Latency is minimized by ordering views in a reverse-centric manner within each reconstruction interval, sampling high-energy views immediately prior to beginning reconstruction. Dispersion is kept low and consistent by synchronizing acquisition and reconstruction, thus avoiding poorly timed reconstruction instances. Real-time implementation demonstrates pulsatile time-of-flight blood signal enhancement in humans.

Algorithms↗

Experimental and theoretical analysis of phase singularity dynamics in cardiac tissue.

INTRODUCTION: Quantitative analysis of complex self-excitatory wave patterns, such as cardiac fibrillation and other high-order reentry, requires the development of new tools for identifying and tracking the most important features of the activation, such as phase singularities. METHODS AND RESULTS: Image processing operations can be used to detect the phase singularity at the tip of a spiral wave. The phase space behavior of a spatiotemporal sequence of data may be reconstructed using time-series analysis. The phase singularities then are localized efficiently by computing the topologic charge density as the curl of the spatial phase gradient. We analyzed the singularity interaction dynamics of both experimentally observed and numerically simulated instances of quatrefoil reentry and found that the singularity behavior in the experimental preparations can be classified into three categories on the basis of how their separation changes with time. CONCLUSION: Topologic charge densities can be calculated easily and efficiently to reveal phase singularity behavior. However, the differences between theoretical and experimental observations of singularity separation distances indicate the need for more sophisticated numerical models.

Action Potentials↗

2D partially parallel imaging with k-space surrounding neighbors-based data reconstruction.

Partially parallel imaging (PPI) achieves imaging acceleration by replacing partial phase encoding (PE) with the spatially localized sensitivity encoding of a receiver surface coil array. Further accelerations can be achieved through 2D PPI along two PE directions in 3D MRI. This paper is to explore the k-space-based PPI acquisition and reconstruction strategies for 3D MRI. A surrounding neighbors-based autocalibrating PPI (SNAPPI) was first presented by generalizing the 2D multicolumn multiline interpolation method. Several 2D PPI reconstruction methods were then provided by applying SNAPPI to recover the partially skipped k-space data along two PE directions separately or nonseparately, in k-space or in the hybrid k and image space. An optimal 2D PPI sampling-based reconstruction approach was also presented for applying PPI along certain spatial direction along which the array coil has not sufficient sensitivity variation for a valid PPI reconstruction. Both simulated and in vivo 2D PPI data were used to evaluate the proposed methods.

Algorithms↗

Reduced MR acquisition time with the CROCUS technique.

A technique to reduce magnetic resonance (MR) image acquisition time by approximately 50% is introduced. The conjugate reconstruction by off-center under-sampling (CROCUS) method samples only every other phase-encoded line in raw data space and uses the conjugate symmetry of the data to reconstruct a real image. If acquisition and image reconstruction were done in the simplest manner, this under-sampling would produce unacceptable image aliasing. However, if the phase-encoded lines are offset from the origin, the assumption of conjugate symmetry allows the image to be calculated without aliasing. Unfortunately, information from all practical MR systems contain phase-shift errors that produce deviations from conjugate symmetry. The CROCUS method incorporates a correction technique, similar to that used in other half-Fourier methods, which uses low-resolution phase-shift information obtained from a few extra lines of phase-encoded data. This paper provides a theoretical derivation of the reconstruction algorithm and correction technique and illustrates the results. Excellent image quality is obtained with no loss of spatial resolution. Image signal-to-noise ratio is reduced by a factor of approximately 1.4 because of the reduced acquisition time. When the imaging circumstances are such that a high signal level is available, CROCUS imaging can be an effective means of reducing imaging time.

Humans↗

Fractal dimension analysis of the oscillated blood flow with a vibrating flow pump.

To analyze the hemodynamic parameters during circulation with oscillated blood flow, nonlinear mathematical analyzing techniques, including fractal theory, were utilized. Vibrating flow pumps (VFP) were implanted as a left heart bypass, and the ascending aorta was clamped to constitute the total left heart circulation with oscillated blood flow in acute animal experiments using 7 adult goats. Using nonlinear mathematical analyzing techniques, reconstructed attractors of the arterial blood pressure waveform in the phase space during natural circulation and oscillated circulation were analyzed. Using the Grassberger-Procaccia correlation dimension analyzing technique, fractal dimension analysis of the reconstructed attractor was performed. During VFP bypass, lower fractal dimensions of the reconstructed attractor were shown compared with those during natural heart circulation. The results suggest that lower dimensional chaotic dynamics contributed to the circulation with oscillated blood flow.

Animals↗

Resolution extension and exit wave reconstruction in complex HREM.

Direct methods in real and reciprocal space are developed for structural reversion. The direct method in real space involves the use of a novel method to retrieve the phase in the image plane using transport of intensity equation/maximum entropy method (TIE/MEM) and exit wave reconstruction by self-consistent propagation. Since the exit wave is restored from the complex signal in the image planes, no image model between the exit wave and image is assumed. The structural information in the reconstructed exit wave is then further extended by a "complex" maximum entropy method as a direct method in reciprocal space to extrapolate the phase to higher frequencies.

Journal Article↗

Nonlinear analysis of continuous ECG during sleep I. Reconstruction.

In recent years evidence has accumulated that ECG signals are of a nonlinear nature. It has been recognized that strictly periodic cardiac rhythms are not accompanied by healthy conditions but, on the contrary, by pathological states. Therefore, the application of methods from nonlinear system theory for the analysis of ECG signals has gained increasing interest. Crucial for the application of nonlinear methods is the reconstruction (embedding) of the time series in a phase space with appropriate dimension. In this study continuous ECG signals of 12 healthy subjects recorded during different sleep stages were analysed. Proper embedding dimension was determined by application of two techniques the false nearest neighbours method and the saturation of the correlation dimension. Results for the ECG signals were compared with findings for simulated data (quasiperiodic dynamics, Lorenz data, white noise) and for phase randomized surrogates. Findings obtained with the two approaches suggest that embedding dimensions from 6 to 8 may be regarded as suitable for the topologically proper reconstruction of ECG signals.

Adult↗

Four-dimensional cone-beam computed tomography using an on-board imager.

On-board cone-beam computed tomography (CBCT) has recently become available to provide volumetric information of a patient in the treatment position, and holds promises for improved target localization and irradiation dose verification. The design of currently available on-board CBCT, however, is far from optimal. Its quality is adversely influenced by many factors, such as scatter, beam hardening, and intra-scanning organ motion. In this work we quantitatively study the influence of organ motion on CBCT imaging and investigate a strategy to acquire high quality phase-resolved [four-dimensional (4D)] CBCT images based on phase binning of the CBCT projection data. An efficient and robust method for binning CBCT data according to the patient's respiratory phase derived in the projection space was developed. The phase-binned projections were reconstructed using the conventional Feldkamp algorithm to yield 4D CBCT images. Both phantom and patient studies were carried out to validate the technique and to optimize the 4D CBCT data acquisition protocol. Several factors that are important to the clinical implementation of the technique, such as the image quality, scanning time, number of projections, and radiation dose, were analyzed for various scanning schemes. The general references drawn from this study are: (i) reliable phase binning of CBCT projections is accomplishable with the aid of external or internal marker and simple analysis of its trace in the projection space, and (ii) artifact-free 4D CBCT images can be obtained without increasing the patient radiation dose as compared to the current 3D CBCT scan.

Algorithms↗

Nonlinear phase correction for navigated diffusion imaging.

Motion during diffusion-weighted imaging (DWI) introduces phase errors that can cause significant artifacts in brain images. One method of correcting these errors uses additional navigator data to measure the phase corruptions. Standard navigator methods correct for rigid-body motion but cannot correct for nonrigid deformations of the brain related to the cardiac cycle. This work derives a generalized reconstruction that corrects for nonrigid motion based on a least-squares formulation. Since this reconstruction has the disadvantage of being computationally expensive, an approximation is presented, called a refocusing reconstruction. The refocusing reconstruction is both efficient and straightforward. Each readout is multiplied in image space by the phase conjugate of the navigator image, and these rephased readouts are then summed. The conditions under which the refocusing reconstruction is sufficient are considered and methods to improve the quality of refocused images are discussed. In particular, synchronization of the acquisition to the cardiac cycle can provide data that is well-conditioned to the refocusing reconstruction without incurring the large time penalty traditionally associated with cardiac gating. These methods are applied to steady-state DWI, a promising pulse sequence that is particularly sensitive to motion-induced phase artifacts. The refocusing reconstruction is shown to significantly improve SS-DWI over standard rigid-body corrections.

Artifacts↗

Nonlinear dynamics of giant resonances in atomic nuclei.

The dynamics of monopole giant resonances in nuclei is analyzed in the time-dependent relativistic mean-field model. The phase spaces of isoscalar and isovector collective oscillations are reconstructed from the time series of dynamical variables that characterize the proton and neutron density distributions. The analysis of the resulting recurrence plots and correlation dimensions indicates regular motion for the isoscalar mode, and chaotic dynamics for the isovector oscillations. Information-theoretic functionals identify and quantify the nonlinear dynamics of giant resonances in quantum systems that have spatial as well as temporal structure.

Journal Article↗

Tailored utilization of acquired k-space points for GRAPPA reconstruction.

The generalized auto-calibrating partially parallel acquisition (GRAPPA) is an auto-calibrating parallel imaging technique which incorporates multiple blocks of data to derive the missing signals. In the original GRAPPA reconstruction algorithm only the data points in phase encoding direction are incorporated to reconstruct missing points in k-space. It has been recognized that this scheme can be extended so that data points in readout direction are also utilized and the points are selected based on a k-space locality criterion. In this study, an automatic subset selection strategy is proposed which can provide a tailored selection of source points for reconstruction. This novel approach extracts a subset of signal points corresponding to the most linearly independent base vectors in the coefficient matrix of fit, effectively preventing incorporating redundant signals which only bring noise into reconstruction with little contribution to the exactness of fit. Also, subset selection in this way has a regularization effect since the vectors corresponding to the smallest singular values are eliminated and consequently the condition of the reconstruction is improved. Phantom and in vivo MRI experiments demonstrate that this subset selection strategy can effectively improve SNR and reduce residual artifacts for GRAPPA reconstruction.

Algorithms↗

Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning.

We describe a method for generating CT images at multiple respiratory phases with a single spiral CT scan, referred to as respiratory-correlated spiral CT (RCCT). RCCT relies on a respiration wave form supplied by an external patient monitor. During acquisition this wave form is recorded along with the initiation time of the CT scan, so as to "time stamp" each reconstructed slice with the phase of the respiratory cycle. By selecting the appropriate slices, a full CT image set is generated at several phases, typically 7-11 per cycle. The CT parameters are chosen to optimize the temporal resolution while minimizing the spatial gap between slices at successive respiratory cycles. Using a pitch of 0.5, a gantry rotation period of 1.5 s, and a 180 degrees reconstruction algorithm results in approximately 5 mm slice spacing at a given phase for typical respiration periods, and a respiratory motion within each slice that is acceptably small, particularly near end expiration or end inspiration where gated radiotherapy is to occur. We have performed validation measurements on a phantom with a moving sphere designed to simulate respiration-induced tumor motion. RCCT scans of the phantom at respiratory periods of 4, 5, and 6 s show good agreement of the sphere's motion with that observed under fluoroscopic imaging. The positional deviations in the sphere's centroid between RCCT and fluoroscopy are 1.1+/-0.9 mm in the transaxial direction (average over all scans at all phases +/-1 s.d.) and 1.2+/-1.0 mm in the longitudinal direction. Reconstructed volumes match those expected on the basis of stationary-phantom scans to within 5% in all cases. The surface distortions of the reconstructed sphere, as quantified by deviations from a mathematical reference sphere, are similar to those from a stationary phantom scan and are correlated with the speed of the phantom. A RCCT scan of the phantom undergoing irregular motion, demonstrates that successful reconstruction can be achieved even with irregular respiration. Limitations from x-ray tube heating in our current CT unit restrict the length of the scan region to 9 cm for the RCCT settings used, though this will not be a limitation for a multislice scanner. RCCT offers an alternative to the current method of respiration-triggered axial scans. Multiple phases of respiration are imaged with RCCT in approximately the same scanning time required to image a single phase with a triggered axial scan. RCCT scans can be used in connection with respiratory-gated treatment to identify the patient-specific phase of minimum tumor motion, determine residual tumor motion within the gate interval, and compare treatment plans at different phases.

Artifacts↗

Partial Fourier imaging in multi-dimensions: a means to save a full factor of two in time.

We present an improvement to the traditional one-dimensional partial Fourier method by extending the method to multi-dimensions. The modified method allowed a full factor of two savings in time with much better coverage of the central k-space information and, because of this, smaller reconstruction artifacts. The residual magnitude error was found to correlate strongly with the residual phase error. Numerical simulation also indicated that with a priori perfect phase information, the original magnitude image could be perfectly reconstructed with half of the k-space data points in the multi-dimensional case. Simulated, phantom, and human data sets were tested with edge differences ranging from 10% (consistent with variable Gibbs ringing) to 25% (consistent with a blurred version of the object). The method was found to be a valuable adjunct to human imaging for short TR, T1-weighted three-dimensional gradient-echo imaging and magnetic resonance (MR) angiographic methods, especially when short echo times were used.

Algorithms↗