PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “BORIC ACID”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40Linked to original sources

The capillary electrophoresis separation of benzodiazepine drug using dextran sulfate and SDS as running buffer.

Capillary electrophoresis has been applied the analyses of many clinical drugs due to its rapid, high-resolution separation. In this study, electrokinetic chromatography involving the combination of SDS and dextran sulfate, which are synthetic polymers, was examined in order to obtain high resolution. Use of 2% dextran sulfate (10,000 molecular weight), 20 mm SDS running buffer containing boric acid solution (pH 9.2) and a silica capillary (inner diameter of 75 micro m, effective length of 50 cm, 57 cm overall length) afforded separation of 10 kinds of benzodiazepines. The detection limit was 0.2 micro g/mL; additionally, reproducibilities were de fi ned as the peak height and migration time. The average peak height was 5.92% (2.46-17.61), whereas the average migration time was 0.44% (0.18-0.76; n = 5). This separations system can be applied to the analysis and measurement of other pharmaceuticals as well.

Benzodiazepines↗

Microemulsion electrokinetic chromatography with laser-induced fluorescence detection: as tested with amino acid derivatives.

Over a decade ago, microemulsion electrokinetic chromatography was introduced as a novel mode of capillary electrophoresis. However, there has not been publication on the combination of microemulsion electrokinetic chromatography with laser-induced fluorescence detection. In this paper, a preliminary method using microemulsion eletrokinetic chromatography combined with laser-induced fluorescence detection and second derivative electrophoregram was established as a sensitive and selective assay for separation and determination of nine amino acids after derivatization with 4-chloro-7-nitrobenzo-2-oxa-1, 3-diazol. The derivatization and separation conditions were optimized. In the investigated concentration ranges correlation coefficients were better than 0.995. The relative standard deviation (n = 5) of the migration times and peak heights were 0.56-0.76 and 2.21-7.15%, respectively. The detection limits (S/N = 3) were at a neaomolar level (0.32-2.20 nM). The method was applied for the analysis of compound amino acid injection and a Chinese traditional herbal medicine. The recoveries were 95.9-107.9%.

4-Chloro-7-nitrobenzofurazan↗

PKU-5: an aluminoborate with novel octahedral framework topology.

A new anhydrous aluminoborate Al4B6O15 (PKU-5) has been synthesized in a boric acid flux in a closed system at 350 degrees C. PKU-5, which crystallizes in the space group R3 with the lattice constants a=11.43398(9) and c=6.48307(5) A, consists of Al octahedra and triangularly coordinated boron. The Al octahedron adopts the (10,3)-a network, in which each octahedron shares three edges with the neighboring octahedra forming ten-membered-ring channels. The octahedral backbone in PKU-5 can be considered as a primary octahedral framework topology and, setting out from the structures of the aluminoborates (PKU-1 and PKU-5), we propose construction rules for the octahedral frameworks. There are two types of connections for edge-sharing octahedra in porous frameworks, trans and cis type, by which various microporous octahedral frameworks of different topologies can be constructed. The borate groups share oxygens with the Al octahedral frameworks forming two kinds of three-membered-ring units consisting of two octahedra and one triangle (2Al+B) and one octahedron and two triangles (Al+2B), respectively.

Aluminum Compounds↗

Molecular evolution using intramolecular acyl migration on myo-inositol benzoates with thermodynamic and kinetic selectors.

A molecular evolution model was successfully demonstrated by combining the intramolecular acyl migration on inositol tribenzoates and boron selectors. The addition of boric acid to 12 members of DCL (dynamic combinatorial library) induced the dramatic amplification of myo-I(2,4,6)Bz(3) (1) with up to 94 % under thermodynamic (see Figure 1 c) control while a portion of phenyl boronic acid caused two significant different distributions: under kinetic control, the pre-equilibrium of DCL shifted to induce the exclusive amplification of 1,4,6-tribenzoyl myo-inositol (7) with decrease of other members up to 82 % from the mixture (see Figure 2 b), and changed gradually to form 2,4,6-tribenzoyl myo-inositol (1) with up to 96 % under thermodynamic control (Figure 2 c).

Journal Article↗

Identification of enantioselective extractants for chiral separation of amines and aminoalcohols.

The major obstacle for the introduction of fractional reactive extraction as a chiral separation method in the chemical and pharmaceutical industries is the lack of versatile enantioselective extractants. Therefore, a rational approach is developed to transfer the extensive knowledge of chiral selectors reported in the literature on chiral recognition and other chiral separation techniques to extraction. Based on a similarity in separation mechanisms, it was expected that chiral selectors originating from a technique in which chiral recognition takes place in the liquid phase are most likely to function as enantioselective extractant. Using this approach, a selection of promising extractants was made from the literature and experimentally evaluated for the enantioseparation of aminoalcohols and amines. As a result, four enantioselective extractant systems, namely, dibutyl-L-tartrate with boric acid, N-(2-hydroxydodecyl)-L-hydroxyproline Cu(II) complex, N-dodecyl-L-hydroxyproline Cu(II) complex, and azophenolic crown ether, have been identified. The azophenolic crown ether system performed the best and demonstrated an enantioselectivity between 1.3-5.0 for five out of six test compounds. Identification of the enantioselective extractant systems was highly facilitated by the developed rational transfer approach that, although partially qualitative, appeared capable of reducing more than 50 encountered candidates to only three promising systems for further experimental evaluation. Therefore, it is expected that this approach can be successfully applied to identify enantioselective extractants for other classes of enantiomers as well.

Amines↗

Micellar electrokinetic chromatographic studies in D2O based buffer solutions.

The addition of deuterium oxide or organic solvents to surfactant-based electrolytes is an effective method for improving resolution in micellar electrokinetic capillary chromatography (MECC). Buffers containing phosphate, boric acid and sodium dodecyl sulphate at pH or pD 7 in the presence and absence of deuterated and non-deuterated solvents were used to separate some hydrophobic compounds covering a range of octanol-water partition coefficients (log P). Significant improvements in resolution of the more hydrophobic compounds were achieved by using mixtures of heavy water and deuterated methanol, instead of water and methanol. Quantitative structure-retention relationships were also derived to provide a better understanding of the intermolecular interactions that contribute to the separation of analytes in MECC. Multiple regression analysis has shown that capacity factors were significantly related to both log P and molecular refractivity. The latter is a measure of the molecular volume of analytes and is related to their ability to undergo dispersive interactions with the micellar components.

Buffers↗

The gel edge electric field gradients in denaturing polyacrylamide gel electrophoresis.

It has previously been shown that zones of higher electric field form close to the loading end of the gel during denaturing polyacrylamide gel electrophoresis. Here we show that the field can reach up to three times its normal mean value a few cm in front of the loading wells when 44.5 mM Tris-44.5 mM boric acid-1 mM EDTA is used as the gel buffer. We also demonstrate that this electric field gradient is mostly due to the difference in ion transference numbers at the gel/buffer interface caused by the high viscosity of the urea solution contained in the gel. This field gradient leads to increased band widths and forces us to redefine both the electrophoretic mobility and the mean field intensity. We discuss some methods that can be used to minimize the effects of this gradient.

Acrylic Resins↗

Thiol redox status evaluation in red blood cells by capillary electrophoresis-laser induced fluorescence detection.

Thiols and in particular glutathione (GSH) play a central role in human metabolism, including the detoxification of xenobiotics, cell homeostasis, radioprotection, and antioxidant defence. Here, a new method is provided for the measurement of reduced and total forms of thiols in red blood cells. In order to minimize oxidation of reduced thiols, a water erythrocyte lysis (15 min at 4 degrees C) was performed followed by a protein precipitation step with acetonitrile. The supernatant was rapidly derivatized with 5-iodoacetoamidefluorescein that trapped thiol groups, thus minimizing auto-oxidation. Derivatized samples were separated in a 57 cm x 75 microm ID capillary by using 5 mmol/L sodium phosphate, 4 mmol/L boric acid as electrolyte solution with 75 mmol/L N-methyl-D-glucamine at pH 11.0. Under these conditions, cysteinylglycine (CysGly), cysteine (Cys), glutathione, and gamma-glutamylcysteine (GluCys) were baseline-resolved in approximately 4 min. Precision tests showed a good repeatability of our method both for migration times (coefficient of variation CV < 0.8%) and areas (CV < 3.3%). Furthermore, a good reproducibility of intrassay and interassay tests was obtained (CV < 5% and CV < 8%, respectively). The method was employed to investigate the effect of acidic precipitation on intracellular thiol concentration. Our data suggest that sample acidification causes a modification of the measured redox thiol status due to the development of a pro-oxidant environment; moreover, the thiol redox status of red blood cells was evaluated in 22 healthy volunteers.

Electrophoresis, Capillary↗

On-line hyphenation of capillary electrophoresis with flame-heated furnace atomic absorption spectrometry for trace mercury speciation.

Capillary electrophoresis (CE) was directly interfaced to flame-heated furnace atomic absorption spectrometry (FHF-AAS) via a laboratory-made thermospray interface for nanoliter trace element speciation. The CE-FHF-AAS interface integrated the superiorities of stable CE separation, complete sample introduction, and continuous vaporization for AAS detection without the need of extra external heat sources and any post-column derivation steps. To demonstrate the usefulness of the developed hybrid technique for speciation analysis, three environmentally significant and toxic forms of methylmercury (MeHg), phenylmercury (PhHg), and inorganic mercury (Hg(II)) were taken as model analytes. Baseline separation of the three mercury species was achieved by CE in a 60 cm long x 75 microm inner diameter fused-silica capillary at 20 kV and using a mixture of 100 mM boric acid and 10% v/v methanol (pH 8.30) as running electrolyte. The precision (relative standard deviation, RSD, n = 7) of migration time, peak area and peak height for the mercury species at 500 microg x L(-1) (as Hg) level were in the range of 0.9-1.2%, 1.5-1.9%, and 1.4-2.0%, respectively. The detection limit (S/N = 3) of three mercury species was 3.0 +/- 0.15 pg (as Hg), corresponding to 50.8 +/- 2.4 microg x L(-1) (as Hg) for 60 nL sample injection, which was almost independent on specific mercury species. The developed hybrid technique was successfully applied to the speciation analysis of mercury in a certified reference material (DORM-2, dogfish muscle).

Electrophoresis, Capillary↗

Integration of a carbon microelectrode with a microfabricated palladium decoupler for use in microchip capillary electrophoresis/electrochemistry.

A method to integrate a carbon microelectrode with a microfabricated palladium decoupler for use in microchip capillary electrophoresis (CE) is detailed. As opposed to previous studies with decouplers for microchip CE, the working electrode material, which is made by micromolding of a carbon ink, is different from the decoupling electrode material (palladium). The manner in which the working electrode is made does not add additional etching or lithographic steps to the fabrication of the glass electrode plate. The hybrid poly(dimethylsiloxane)/glass device was characterized with fluorescence microscopy and by monitoring the CE-based separation of dopamine. Hydrodynamic voltammograms exhibited diffusion-limited currents occurring at potentials above +1.0 V. It was also shown that the half-wave potential does not shift as the separation potential is changed, as is the case in nondecoupled systems. Gated injections of dopamine in a 25 mM boric acid buffer (pH 9.2) showed a linear response from 200 to 5 microM (r2 = 0.9992), with a sensitivity of 5.47 pA/microM and an estimated limit of detection of 2.3 microM (0.621 fmol, S/N = 3). This is the first report of coupling a carbon electrode with a decoupler in microchip CE.

Carbon↗

Analysis of positional isomers of hydroxylated aromatic cytokinins by micellar electrokinetic chromatography.

A micellar electrokinetic chromatography (MEKC) method was developed for the separation of six positional isomers of hydroxylated aromatic cytokinins (topolin and topolin riboside), including ortho-topolin, meta-topolin, para-topolin, ortho-topolin riboside, meta-topolin riboside, and para-topolin riboside. Optimum resolution and analysis time (ca. 20 min) for the six aromatic cytokinin standards were achieved with a running buffer at pH 8.0 consisting of 20 mM boric acid, 50 mM sodium dodecyl sulfate (SDS), and 20% v/v methanol. The method has good reproducibility and has been successfully applied to detect the presence of a putative ortho-topolin in coconut water extract sample purified using C(18) and mixed-mode solid-phase extraction (SPE) columns. Other advantages of this MEKC method are short analysis time, low solvent consumption, and separation of positional isomers which could be achieved by a simple aqueous buffer system without the use of expensive chromatographic columns. In addition, a high-performance liquid chromatography (HPLC) method with baseline separation of the six topolin and topolin riboside standards was developed for the confirmation of the endogenous ortho-topolin in coconut water sample. Finally, the presence of ortho-topolin was further confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) based on its characteristic fragmentation pattern.

Chromatography, Micellar Electrokinetic Capillary↗

Determination of biogenic amines in HeLa cell lysate by 6-oxy-(N-succinimidyl acetate)-9-(2'-methoxycarbonyl) fluorescein and micellar electrokinetic capillary chromatography with laser-induced fluorescence detection.

An MEKC-LIF method using 6-oxy-(N-succinimidyl acetate)-9-(2'-methoxy-carbonyl) fluorescein (SAMF) newly synthesized in our lab as a labeling reagent for the separation and determination of eight typical biogenic amines was proposed. After careful study of the derivatization condition such as pH value, reagent concentration, temperature, and reaction time, derivatization reaction was accomplished as quickly as 10 min with stable yield. Optimal separation of SAMF-labeled amines was achieved with a running buffer (pH 9.3) containing 30 mM boric acid, 25 mM SDS, and 20% v/v ACN. The proposed method allowed biogenic amines to be determined with LODs as low as 0.25-2.5 nmol/L and RSD values from 0.4 to 4.5%. The present method has been successfully used to monitor biogenic amines in HeLa cells and fish samples. This study exploits the potential of MEKC-LIF with SAMF labeling as a tool for monitoring biogenic amines involved in complex physiological and behavioral processes in various matrices.

Biogenic Amines↗

A method for simultaneously determining the zeta potentials of the channel surface and the tracer particles using microparticle image velocimetry technique.

The zeta potentials of channel surfaces and tracer particles are of importance to the design of electrokinetic microfluidic devices, the characterization of channel materials, and the quantification of the microparticle image velocimetry (microPIV) measurement of EOFs. A method is proposed to simultaneously measure the zeta potentials of the channel surface and the tracer particles in aqueous solutions using the microPIV technique. Through the measurement of the steady velocity distributions of the tracer particles in both open- and closed-end rectangular microchannels under the same water chemistry condition, the electrophoretic velocity of the tracer particles and the EOF field of the microchannel are determined using the expressions derived in this study for the velocity distributions of charged tracer particles in the open- and closed-end rectangular microchannels. Thus, the zeta potentials of the tracer particles and the channel surfaces are simultaneously obtained using the least-square method to fit the microPIV measured velocity distribution of the tracer particles. Measurements were carried out with a microPIV system to determine the zeta potentials of the channel wall and the fluorescent tracer particles in deionized water and sodium chloride and boric acid solutions of various concentrations.

Electrophoresis↗

Nanostructured polymer matrix for oligonucleotide separation.

A nanostructured copolymer matrix has successfully separated oligonucleotides with high resolution by CE using a very short separation channel which simulates the real microchip condition for the first time. The triblock copolymer, E(45)B(14)E(45) (B20-5000) with E, B, and subscript denoting oxyethylene, oxybutylene, and segment length, respectively, has a unique temperature-dependent viscosity-adjustable property and a dynamic coating ability in 1xTBE buffer (89 mM Tris, 89 mM boric acid, 2 mM EDTA in Milli-Q water). The B-block is hydrophilic at low temperatures, e.g., 4 degrees C, and the polymer solution has a very low viscosity of about 100 cP in a 32.5% w/v solution. At room temperatures, the B-block becomes hydrophobic due to a breakdown of hydrogen bonds between B-blocks and water, and the polymer matrix forms a body-centered cubic structure at high concentrations. Oligonucleotide sizing markers ranging from 8 to 32 base could be successfully separated with one-base resolution in a 1.5 cm long separation channel by E(45)B(14)E(45) in its gel-like state.

Electrophoresis, Capillary↗

[Alkali treatment of proteins. I. Behavior of sulfhydryl and disulfide groups in alkali-treated beta-lactoglobulin and alpha-lactalbumin].

The alkali treatment of beta-lactoglobulin and alpha-lactalbumin results in the splitting of disulphide bonds in the protein molecules. When a 0.8-10(4) M beta-lactoglobulin solution in a 0.022 N sodium hydroxide solution (pH = 12) is heated at 90 degrees C for 30 min, 0-4 M disulphide groups, 2.2 M sulfhydryl groups and 1.8 M sulphide ions/M dimeric beta-lactoglobulin are detectable of the total of 4 M disulphide groups and 2 M sulfhydryl groups/M dimeric beta-lactoglobulin. The sulphide ions can be determined directly in the form of hydrogen sulphide or by calculating the difference between the values from the amperometric-argentometric titration and those from the method of ELLMAN (reaction with DTNB). The disulphide groups are determined with the aid of DTNB after reduction with sodium borohydride. The sulfhydryl groups obtained by reduction with sodium borohydride re-oxidize, the reaction velocity being of the second order. If the disulphide groups are reduced with sodium borohydride, the argentometric-amperometric determination of the sulfhydryl groups by means of the platinum rotating-disk electrode is disturbed by the presence of boric acid.

Chemical Phenomena↗

[Quantitative determination of the protein content of milk by ultraviolet spectrophotometry. 3. Determination of proteins in preserved milk samples].

It is reported upon the results of the quantitative estimation of protein content from preserved milk by means of ultraviolet spectrophotometry. In addition to the preservation by boric acid, bronopol, copper sulphate, potassium dichromate and ammonium peroxodisulphate storage at temperatures below 0 degrees C and freeze drying were tested. Besides bronopol and copper sulphate especially physical preservation methods proves fit for the protein estimation by measurements of absorbance at 210 nm, 235 and 280 nm or 210 and 220 nm. It is recommended to use solutions and filters of quartz with evaluated absorbance in daily calibrating of the spectrophotometer.

Animals↗

Buffer solution can control the porosity of DNA-chitosan complexes.

The current studies examine the pore properties and biological effects of DNA-chitosan complexes, which may be useful as scaffolds for tissue engineering. The porosity of the DNA-chitosan complexes was controlled by rinsing them with several different pH 7.2 buffer solutions, including phosphate-buffered saline (PBS), Tris-HCl, boric acid, and N-(2-hydroxyethyl)piperazine-N'-(2-ethanesufonic acid) (HEPES). Rinsing with PBS resulted in 84% porosity, whereas rinsing with Tris-HCl produced 94% porosity. It was further found that daunorubicin hydrochloride complex intercalated with and bound to the groove of the DNA-chitosan complexes, indicating that DNA in the complexes maintains its double-stranded helical structure. The DNA-chitosan complexes were not toxic to MG-63 osteoblast-like cells and caused only a mild tissue response when implanted subcutaneously in the backs of rats. These results suggest that buffer-rinsed DNA-chitosan complexes may be useful as a scaffold material in tissue engineering.

Buffers↗

Borate-nucleotide complex formation depends on charge and phosphorylation state.

Flow injection analysis with electrospray ionization mass spectrometry was used to investigate borate-nucleotide complex formation. Solutions containing 100 microM nucleotide and 500 microM boric acid in water-acetonitrile-triethylamine (50:50:0.2, v/v/v; pH 10.3) showed that borate complexation with nicotinamide nucleotides was significantly influenced by the charge on the nicotinamide group and the number of phosphate groups on the adenine ribose. Borate binding decreased in the order of NAD(+), NADH, NADP(+) and NADPH. To investigate the relationship between complex formation and phosphorylation, association constants (K(A)) of borate-adenine (AMP, ADP, ATP), -guanine (GMP, GDP, GTP), -cytidine (CMP, CDP, CTP) and -uridine (UMP, UDP, UTP) complexes were compared. The results showed that the number of nucleotide phosphate groups was inversely proportional to the relative abundance of the borate complexes, with the K(A) of borate-nucleotide complex decreasing in the order mono-, di- and tri-phosphates (AMP approximately GMP approximately CMP approximately UMP > ADP approximately GDP approximately CDP approximately UDP > GTP > ATP approximately CTP approximately UTP). At pH 7.4, using ammonium bicarbonate buffer, only borate-NAD(+) complex was observed. This indicates that the borate-NAD(+) complex may be the most physiologically relevant of those studied.

Borates↗