PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Diffusion”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40Linked to original sources

Changes in axonal morphology in experimental autoimmune neuritis as studied by high b-value q-space (1)H and (2)H DQF diffusion magnetic resonance spectroscopy.

Experimental autoimmune neuritis (EAN) has been studied in rat sciatic nerves by a combination of high b-value (1)H and (2)H double quantum filtered (DQF) diffusion MRS. The signal decays of water in the (1)H and (2)H DQF diffusion MRS were found to be not monoexponential and were analyzed using the q-space approach. The q-space analysis of the (1)H diffusion data detected two diffusing components, one having broad and the other having narrow displacement profiles. These components were shown to be very sensitive to the progression of EAN disease. The q-space parameters were found to be abnormal at day 9 postimmunization before the appearance of clinical signs. The assignment of the component with the narrow displacement profile to axonal water has been corroborated by the (2)H DQF diffusion MRS results. The displacement and the relative population of this slow and restricted diffusing component followed the processes of demyelination, axonal loss, and remyelination that occur in EAN. The displacements extracted from the slow-diffusing component with the narrow displacement correlated well with the average size of the axons as deduced from electron microscopy (EM). The component with the broad displacement showed significant changes which were attributed to the formation of endoneurial edema. This observation was also corroborated by the (2)H DQF diffusion MRS experiments. It seems, therefore, that q-space analysis of high b-values diffusion MRS is a promising new approach for early detection and better characterization of the different pathologies associated with EAN. This study demonstrates the utility of high-b-value q-space diffusion MRS for studying white matter-associated disorders in general.

Animals↗

Cardiac diffusion MRI without motion effects.

We present a method for diffusion tensor MRI in the beating heart that is insensitive to cardiac motion and strain. Using a stimulated echo pulse sequence with two electrocardiogram (ECG) triggers, diffusion-encoding bipolar gradient pulses are applied at identical phases in consecutive cardiac cycles. In this experiment, diffusion is encoded at a single phase in the cardiac cycle of less than 30 ms in duration. This encoding produces no phase shifts for periodic motion and is independent of intervening strains. Studies in a gel phantom with cyclic deformation confirm that by using this sequence we can map the diffusion tensor free of effects of cyclic motion. In normal human subjects, myocardial diffusion eigenvalues measured with the present method showed no significant change between acquisitions encoded at maximum contractile velocity (peak) vs. at myocardial standstill (end-systole), demonstrating motion independence of in vivo diffusion measurements. Diffusion tensor images acquired with the present method agree with registered data acquired with a previous cardiac diffusion MRI method that was shown to be valid in the normal heart, strongly supporting the validity of MRI diffusion measurement in the beating heart. Myocardial sheet and fiber dynamics measured during systole showed that normal human myocardial sheet orientations tilt toward the radial during systole, and fiber orientations tilt toward the longitudinal, in qualitative agreement with previous invasive studies in canines. These results demonstrate the technique's ability to measure myocardial diffusion accurately at any point in the cardiac cycle free of measurable motion effect, as if the heart were frozen at the point of acquisition.

Diffusion↗

Visualization and analysis of white matter structural asymmetry in diffusion tensor MRI data.

This work presents a method that permits the characterization, quantification, and 3D visualization of white matter structural information contained within diffusion tensor MR imaging (DT-MRI) data. In this method, regions within the brain are defined as possessing linear, planar, or spherical diffusion. Visualization of this diffusion metric data is realized by generating streamtube and streamsurface models to represent regions of linear and planar diffusion. Quantification of differences in diffusion anisotropy between different regions of interest (ROIs) is then achieved by analyzing 2D barycentric histograms created from the complete distribution of diffusion metric values measured in each region. In four healthy volunteers, there was only a small degree of asymmetry (epsilon) in the number of linear, planar, or spherical diffusion voxels between the right and left hemispheres (epsilon approximately equal to +/- 2%). However, in a patient with a metastatic brain lesion there was marked asymmetry in both linear (epsilon approximately -10%) and planar (epsilon approximately equal to 5%) diffusion between comparable ipsilateral and contralateral regions, with a significant reduction in the number of linear diffusion voxels and an increase in the number of planar diffusion voxels in the tumor-bearing hemisphere. These results demonstrate the potential of this approach to characterize brain structure in both healthy and diseased subjects.

Adenocarcinoma↗

New modeling and experimental framework to characterize hindered and restricted water diffusion in brain white matter.

To characterize anisotropic water diffusion in brain white matter, a theoretical framework is proposed that combines hindered and restricted models of water diffusion (CHARMED) and an experimental methodology that embodies features of diffusion tensor and q-space MRI. This model contains a hindered extra-axonal compartment, whose diffusion properties are characterized by an effective diffusion tensor, and an intra-axonal compartment, whose diffusion properties are characterized by a restricted model of diffusion within cylinders. The hindered model primarily explains the Gaussian signal attenuation observed at low b values; the restricted non-Gaussian model does so at high b. Both high and low b data obtained along different directions are required to estimate various microstructural parameters of the composite model, such as the nerve fiber orientation(s), the T2-weighted extra- and intra-axonal volume fractions, and principal diffusivities. The proposed model provides a description of restricted diffusion in 3D given by a 3D probability distribution (average propagator), which is obtained by 3D Fourier transformation of the estimated signal attenuation profile. The new model is tested using synthetic phantoms and validated on excised spinal cord tissue. This framework shows promise in determining the orientations of two or more fiber compartments more precisely and accurately than with diffusion tensor imaging.

Animals↗

"Squashing peanuts and smashing pumpkins": how noise distorts diffusion-weighted MR data.

New diffusion-weighted imaging (DWI) methods, including high-b, q-space, and high angular resolution MRI methods, attempt to extract information about non-Gaussian diffusion in tissue that is not provided by low-b-value (b approximately 1000 s mm(-2)) diffusion or diffusion tensor magnetic resonance imaging (DT-MRI). Additionally, DWI data with higher spatial resolution are being acquired to resolve fine anatomic structures, such as white matter fasciculi. Increasing diffusion-weighting or decreasing voxel size can reduce the signal-to-noise ratio so that some DWI signals are close to the background noise level. Here we report several new artifacts that can be explained by considering how background noise affects the peanut-shaped angular apparent diffusion coefficient (ADC) profile. These include an orientationally dependent deviation from Gaussian behavior of the ADC profile, an underestimation of indices of diffusion anisotropy, and a correlation between estimates of mean diffusivity and diffusion anisotropy. We also discuss how noise can cause increased gray/white matter DWI contrast at higher b values and an apparent elevation of diffusion anisotropy in acute ischemia. Importantly, all of these artifacts are negligible in the b-value range typically used in DT-MRI of brain (b approximately 1000 s mm(-2)). Finally, we demonstrate a strategy for ameliorating the rectified noise artifact in data collected at higher b values.

Anisotropy↗

Biexponential parameterization of diffusion and T2 relaxation decay curves in a rat muscle edema model: decay curve components and water compartments.

Quantitative T2 relaxation and diffusion imaging studies of a rat muscle edema model were performed in order to determine the effects of intra- and extracellular water compartmentation on the respective decay curves. The right hind paw of rats was injected with a carrageenan solution to generate edematous muscle. A Carr-Purcell-Meiboom-Gill (CPMG) imaging sequence was used to acquire T2 relaxation decay curves from both paws. A line scan diffusion imaging (LSDI) sequence was then used to acquire diffusion decay curves from the same paws over a wide b-factor range. Measurements were made from both edematous muscle (EM) and control muscle (CM). The EM and CM T2 relaxation decay curves were best fit with biexponential functions. The fraction of the fast T2 component dropped dramatically from approximately 0.95 in CM to 0.45 in EM, consistent with a water compartmentation model in which the fast and slow T2 components reflect intra- and extracellular water, respectively. Both CM and EM diffusion decay curves required biexponential fitting functions, and the diffusion coefficients of the fast and slow components were substantially larger in EM than CM. The fraction of the fast diffusion component, however, was not radically altered between CM and EM conditions (0.84 versus 0.89 for CM versus EM). Assuming a model in which intra- and extracellular water compartments are responsible for the fast and slow T2-decay components and for the slow and fast diffusion decay components, respectively, leads to fractional sizes of the diffusion components that are not supported by experiment. We conclude that intra- and extracellular water compartmentation is a reasonable interpretation for the two T2-decay components in both CM and EM but that other factors, such as restricted diffusion and/or alternate forms of water compartmentation like surface versus volume water, most probably have profound influences on the precise shapes of the diffusion decay curves, a complete understanding of which will require significant theoretical work.

Animals↗

Effects of cord motion on diffusion imaging of the spinal cord.

Measurement of diffusion and its dependence on direction has become an important tool for clinical and research studies of the brain. Diffusion imaging of the spinal cord may likewise prove useful as an indicator of tissue damage and axonal integrity; however, it is more challenging to perform diffusion imaging in the cord than in the brain. Here we report a study of the effects of motion on single-shot fast spin echo (FSE) diffusion tensor imaging (DTI) of the spinal cord. Diffusion imaging was performed at four different times in the cardiac cycle both without and with velocity compensation of the diffusion gradients. Uncompensated diffusion images demonstrated substantial signal loss artifacts in the cord that were strongly dependent on the delay after the pulse-oximeter trigger. Quantitative diffusion analysis was also strongly affected by this motion artifact. The use of flow-compensated gradients helped to restore normal signal in the cord, especially at particular trigger delays. Theoretical arguments suggest that improved spatial resolution may help eliminate this signal loss. Even with higher spatial resolution, motion-related signal attenuation may still occur in diffusion imaging of pathologies that alter the motion of the cord. However, this same cord motion may contain diagnostically valuable information when probed using appropriate diffusion imaging approaches.

Adult↗

High b-value q-space analyzed diffusion-weighted MRS and MRI in neuronal tissues - a technical review.

This review deals with high b-value q-space diffusion-weighted MRI (DW-MRI) of neuronal tissues. It is well documented that at sufficiently high b-values (and high q-values) neuronal water signal decay in diffusion experiments is not mono-exponential. This implies the existence of more than one apparent diffusing component or evidence for restriction. The assignment of the different apparent diffusing components to real physical entities is not straightforward. However, the apparent slow diffusing component that was found to be restricted to a compartment of a few microns, if originating mainly from a specific pool and if assigned correctly, may potentially be used to obtain more specific MR images with regard to specific pathologies of the CNS. This review examines the utility of analyzing high b-value diffusion MRS and MRI data using the q-space approach introduced by Callaghan and by Cory and Garroway. This approach provides displacement probability maps that emphasize, at long diffusion times, the characteristics of the apparent slow diffusing component. Examples from excised spinal cord, where the experimental conditions for which the q-space analysis of MR diffusion data was developed can be met or approached will be presented. Then examples from human MS patients, where q-space requirement for the short gradient pulse is clearly violated, are presented. In the excised spinal cord studies, this approach was used to study spinal cord maturation and trauma, and was found to be more sensitive than other conventional methods in following spinal cord degeneration in an experimental model of vascular dementia (VaD). High b-value q-space DWI was also recently used to study healthy and MS diseased human brains. This approach was found to be very sensitive to the disease load in MS, compared with other conventional MRI methods, especially in the normal appearing white matter (NAWM) of MS brains. Finally, the potential diagnostic capacity embedded in high b-value q-space analyzed diffusion MR images is discussed. The potentials and caveats of this approach are outlined and experimental data are presented that show the effect of violating the short gradient pulse (SGP) approximation on the extracted parameters from the q-space analysis.

Algorithms↗

The role of isotropic diffusion MRI in children under 2 years of age.

Our objective was to determine the contribution of diffusion MR imaging to standard MR imaging in the neuroradiological evaluation of children less than 2 years of age. Echo-planar diffusion MR imaging was added to standard MR exams in 75 consecutive patients under the age of 2 years. Single-shot echo-planar spin-echo T2 weighted images (EPSE-T2) were acquired. Isotropic diffusion-weighted images (DWI), attenuation coefficient maps (ACM), and apparent diffusion co-efficient (ADC) maps were calculated offline from images obtained with diffusion gradients (b = 1000 s/mm2) in three orthogonal directions. Two neuroradiologists determined if EPSE-T2, DWI, or ACM contributed new information to spin-echo proton density (SE PD) and T2 studies. In 15 of 18 abnormalities detected in 8 patients with symptoms less than 1 week in duration, DWI and/or ACM added information to SE PD and T2. Diffusion sequences detected five new lesions, showed six lesions with greater conspicuity, and identified four lesions with different diffusion character. In patients with symptoms of more than 7 days duration, diffusion studies added no information. Isotropic diffusion MR contributed to lesion detection and characterization in infants when symptoms were less than 1 week in duration. Diffusion MR is useful in patients with leukodystrophies, metabolic disorders, and patients with acute ischemic lesions.

Adult↗

Two-dimensional diffusion of F1F0-ATP synthase and ADP/ATP translocator. Testing a hypothesis for ATP synthesis in the mitochondrial inner membrane.

We report here the first experimentally determined lateral diffusion coefficients of the F1F0-ATP synthase and the ADP/ATP translocator in isolated inner membranes of rat liver mitochondria. Rabbit IgG developed against the F1F0-ATP synthase isolated from rat liver mitochondria was determined to be immunospecific for the synthase subunits, notably the alpha-beta doublet, gamma and delta subunits of F1 and subunits two, three and four of F0. This IgG, conjugated with lissamine-rhodamine, was used as a fluorescent probe to monitor the diffusion of the synthase in the membrane. IgG to cytochrome bc1 complex, prepared and labeled similarly, was used as a fluorescent probe for diffusion of this redox component. Eosin maleimide was determined to specifically label the ADP/ATP translocator in the isolated inner membrane and was used as a specific probe for the diffusion of the translocator. Using fluorescence recovery after photobleaching, the experimental average lateral diffusion coefficient of the F1F0-ATP synthase was determined to be 8.4 x 10(-10) cm2/s or twice that of cytochrome bc1 complex while the diffusion coefficient of the ADP/ATP translocator was 1.7 x 10(-9) cm2/s or four times that of cytochrome bc1 complex suggesting that all three components are independent two-dimensional diffusants. Using these diffusion coefficients and applying a number of basic assumptions, we calculated the theoretical two-dimensional diffusion-controlled collision frequencies and derived collision efficiencies (protons transferred per collision) between each of the three proton-transferring redox complexes and both the F1F0-ATP synthase and ADP/ATP translocator by treating the redox components as proton donors and the synthase and translocator as proton acceptors. These collision efficiencies support the physical possibility of a diffusion-based, random collision process of proton transfer and ATP synthesis in the mitochondrial inner membrane.

Adenosine Triphosphate↗

Computer simulation of ternary diffusion in distal airways of the human lung.

Gaseous diffusion plays a fundamental role in the terminal generations of airways for respiratory physiology. It has been proposed as a prime mechanism underlying stratified inhomogeneity in the alveolar space. Nevertheless, the diffusion phenomenon in the lung has often been studied using Fick's law which is only valid for binary diffusion. Under conditions of more than two gases in a mixture, the appropriate equations for diffusion are those of Stefan. In respiration, diffusion involves at least three gases (O2, CO2 and N2), and in physiological experiments complex mixtures including heavy or light gases (SF6, He) are often added to enhance the effect of diffusion. We present in this paper the features of ternary diffusion and solve the appropriate equations for the non-steady state by a finite difference method. The simulation was performed using two models derived from the anatomical data of Weibel and Hansen-Ampaya. Moreover, four initial conditions most often encountered during current respiratory physiology tests, were used for the computations. Therefore in these four situations, O2-N2-He, O2-N2-Ar, O2-N2-SF6 and O2-N2-CO2 combinations were used. Our results showed that for each case mentioned above the oxygen acted differently in ternary diffusion owing to the specific nature of the components of each mixture. Moreover, the behaviour of each component in ternary diffusion was very different from that of binary diffusion. However, this difference may be negligible when the subject breathed normal air.

Computers↗

Some implications of ternary diffusion in the lung.

Diffusion in the lung normally involves three gases and the governing laws are Stefan-Maxwell equations rather than the more familiar Fick's law. A simple gas film model is studied mathematically to (1) demonstrate that the rate of diffusion of a component gas may be zero even though its concentration gradient is not zero (known as "diffusion barrier"), that the rate of diffusion of a component gas may not be zero even though its concentration gradient is zero ("osmotic diffusion"), and that a component gas may diffuse against the gradient of its concentration ("reverse diffusion"); (2) compare the discrepancy between results obtained by binary and ternary laws separately; (3) determine the importance of ternary diffusion at high pressure. The findings from the model study suggest that the effects of ternary diffusion may not be pronounced when air is breathed under normal conditions, but the behavior of helium mixtures deviate significantly from that described by binary diffusion laws.

Biological Transport↗

Diffusion of sucrose and dextran through agar gel membranes.

Mass transfer limitations severely impede the performance of bioreactions involving large molecules by gel-entrapped microorganisms. This paper describes a quantitative investigation of such diffusional limitations in agar gel membranes. Sucrose and commercial dextran fractions with (weight-average) molecular weights ranging from 10,000 to 2,000,000 Da were used as standard diffusants. For all tested solutes but sucrose, the values of the agar/water partition coefficients highlighted steric hindrance at the entrance of the membrane pores. The effective diffusivity of sucrose in agar was similar to that in water. All dextran fractions, however, displayed restricted diffusion in the agar membranes. Their effective diffusivities were a decreasing function of the agar content of the gel membrane (0.5, 1.0, or 1.5% w/v). The effective diffusivity in a given membrane decreased as the molecular weight of the diffusing molecule increased. T500 (Mw = 470,000 Da) and T2000 (Mw = 1,950,000 Da) fractions were unable to diffuse through 1.0 or 1.5% agar membranes. The diffusion data did not agree with the classical (Renkin) model for a hard sphere diffusing through a cylindrical pore. These results are discussed in terms of gel and diffusant characteristics.

Agar↗

Postictal diffusion tensor imaging.

The objective of the study was to investigate postictal diffusion tensor imaging (DTI) in focal epilepsy. DTI and statistical parametric mapping (SPM) were used to examine objectively the diffusion properties of the brains of 18 patients with intractable focal epilepsy both postictally and interictally and to compare them with 27 normal controls scanned twice. Three sets of statistical tests were performed on each patient's fractional anisotropy and mean diffusivity data: interictal versus controls, postictal versus controls and a third "difference analysis" to test for significant changes in comparison with the differences noted between the two sets of control scans. Thirteen of the 18 patients (72%) had significant increases in mean diffusivity in the interictal scan. No decreases in mean diffusivity were detected. The difference analysis detected significant relative decreases in mean diffusivity postictally in nine patients (50%). These changes were focal in seven patients. In six of these, the site of the epileptic focus was known and co-localized with the diffusivity change in three. No significant changes in anisotropy were noted between the post- and interictal states. The postictal decrease in diffusivity probably reflects cellular swelling in the area of seizure onset and possibly areas of seizure spread. Postictal diffusivity changes appear complex and dynamic and timing after the seizure may be critical. Anisotropy measures appear less sensitive to these changes. Further systematic studies are needed and correlation with outcome after epilepsy surgery will determine the role of postictal diffusion measures in the presurgical evaluation of epilepsy patients.

Adult↗

The effect of a biofilm on solute diffusion in fractured porous media.

At sites in fractured rock where contamination has been exposed to the rock matrix for extended periods of time, the amount of contaminant mass residing in the matrix can be considerable. Even though it may be possible to diminish concentrations by the advection of clean water through the fracture features, back diffusion from mass held in the matrix will lead to a continuing source of contamination. In such an event, the development of a biofilm (a thin film of microbial mass) on the wall of the fractures may act to limit or prevent the back diffusion process. The objective of this preliminary study is to explore the influence imparted by the presence of a biofilm on the process of matrix diffusion. The investigation was conducted using radial diffusion cells constructed from rock core in which biofilm growth was stimulated in a central reservoir. Once biofilms were developed, forward diffusion experiments were conducted in which a conservative solute migrated from the central reservoir into the intact rock sample. Diffusion experiments were performed in a total of 11 diffusion cell pairs where biofilm growth was stimulated in one member of the pair and inhibited in the other. The effect of the presence of a biofilm on tracer diffusion was determined by comparison of the diffusion curves produced by each cell pair. A semi-analytical model that accounts for the presence of a biofilm was used to investigate the effect of the biofilm on mass transfer due to changes in the effective porosity, effective diffusion coefficient, and the depth of penetration of the biofilm into the intact rock. The results show that the biofilm acted to plug the rock matrix, rather than forming a discrete layer on the reservoir surface. The reduction in effective porosity due to the biofilm ranged from 6% to 52% with the majority of the samples in the 30% to 50% range. Based on the present results, with more efficient biofilm stimulation, it is reasonable to assume that a more complete plugging of the microcrack porosity might be possible, leaving a much thicker and efficient barrier than could be achieved via a surface biofilm.

Biofilms↗

Self-diffusion measurements by a mobile single-sided NMR sensor with improved magnetic field gradient.

A simple and fast method of measuring self-diffusion coefficients of protonated systems with a mobile single-sided NMR sensor is discussed. The NMR sensor uses a magnet geometry that generates a highly flat sensitive volume where a strong and highly uniform static magnetic field gradient is defined. Self-diffusion coefficients were measured by Hahn- and stimulated echoes detected in the presence of the uniform magnetic field gradient of the static field. To improve the sensitivity of these experiments, a Carr-Purcell-Meiboom-Gill pulse sequence was applied after the main diffusion-encoding period. By adding the echo train the experimental time was strongly shortened, allowing the measurement of complete diffusion curves in less than 1min. This method has been tested by measuring the self-diffusion coefficients D of various organic solvents and poly(dimethylsiloxane) samples with different molar masses. Diffusion coefficients were also measured for n-hexane absorbed at saturation in natural rubber with different cross-link densities. The results show a dependence on the concentration that is in good agreement with the theoretical prediction. Moreover, the stimulated-echo sequence was successfully used to measure the diffusion coefficient as a function of the evolution time in systems with restricted diffusion. This type of experiment proves the pore geometry and gives access to the surface-to-volume ratio. It was applied to measure the diffusion of water in sandstones and sheep Achilles tendon. Thanks to the strong static gradient G(0), all diffusion coefficients could be measured without having to account for relaxation during the pulse sequence.

Achilles Tendon↗

Diffusion tensor MRI as a diagnostic tool of upper motor neuron involvement in amyotrophic lateral sclerosis.

BACKGROUND: Clinical identification of upper motor neuron (UMN) dysfunction in amyotrophic lateral sclerosis (ALS) is often difficult, particularly early in the course of the disease, or when lower motor neuron (LMN) dysfunction is prominent. Diffusion tensor MR imaging (DTI) can provide unique information on axonal organization by measuring diffusion anisotropy and the directionally independent diffusion. OBJECTIVE: The purpose of this study was to assess water diffusion changes along pyramidal tracts of the brainstem in patients with ALS and to investigate possible correlations between changes of diffusion properties and various clinical parameters. METHODS: We studied 16 patients (M:F=9:7, 50.5+/-12.4 years) with ALS as defined by clinical and electrophysiological examinations. These patients were compared with 11 healthy, age and sex-matched controls (M:F=5:6, 54.5+/-9.9 years). DTI was performed using a single shot SE-EPI with 25 noncollinear diffusion gradient directions (b=1000 s/mm(2)) and with no diffusion gradient on a 3.0-T MR system. RESULTS: By multifactorial ANOVA, the effects of group (patient versus control) and anatomical level on fractional anisotropy (FA) and mean diffusivity (MD) were significant (p<0.001 for both parameters), whereas the effect of side (left versus right) and interactions between factors (group by side and group by anatomical level) were not (p>0.05). In all subjects, FA and MD varied greatly depending on the anatomical level, and FA was highly variable even between contiguous slices in the pons and medulla, whereas relatively constant FA values were noted at the level of the midbrain. Cerebral peduncle was the only area that showed significant differences of diffusion properties between patients and controls (p<0.001 for FA, p=0.001 for MD). Correlation analysis revealed a significant inverse relationship between the FA value and the extent of UMN signs (r=-0.81, p<0.001). CONCLUSIONS: Alteration of diffusion properties in the cerebral peduncle in ALS may reflect pathological changes in structures rather than regional architectural variations of the corticospinal tracts or experimental artifacts.

Adult↗

MRI diffusion tensor reconstruction with PROPELLER data acquisition.

MRI diffusion imaging is effective in measuring the diffusion tensor in brain, cardiac, liver, and spinal tissue. Diffusion tensor tomography MRI (DTT MRI) method is based on reconstructing the diffusion tensor field from measurements of projections of the tensor field. Projections are obtained by appropriate application of rotated diffusion gradients. In the present paper, the potential of a novel data acquisition scheme, PROPELLER (Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction), is examined in combination with DTT MRI for its capability and sufficiency for diffusion imaging. An iterative reconstruction algorithm is used to reconstruct the diffusion tensor field from rotated diffusion weighted blades by appropriate rotated diffusion gradients. DTT MRI with PROPELLER data acquisition shows significant potential to reduce the number of weighted measurements, avoid ambiguity in reconstructing diffusion tensor parameters, increase signal-to-noise ratio, and decrease the influence of signal distortion.

Algorithms↗