PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40Linked to original sources

Preparation and characterization of porous silica-coated multifibers for solid-phase microextraction.

C18-bonded silica-coated multifibers were prepared and studied as a stationary phase for solid-phase microextraction (SPME). The porous multifiber SPME provided larger absorption capacity and higher absorption rate compared to a polymer-coated single fiber. Its absorption rate was 10 times higher than that of a commercial 100-microm poly(dimethylsiloxane) (PDMS)-coated fiber. Its high extraction efficiency enabled the positive identification of unknown compounds at sub-part-per-billion level in full-scan mode with a benchtop quadruple GC/MS. The desorption temperature indicated that the analyte interactions with the C18-bonded silica were stronger than those with the PDMS polymer. The dependence of the equilibration time on the molecular weight was not observed for the porous multifiber SPME. The boundary layer between the fiber coating and the sample matrix could be the absorption control step in SPME under mild agitation. The special experimental conditions in the porous multifiber SPME, such as air interference and polar organic solvent wetting, were investigated.

Chromatography, Gas↗

Rapid determination of amino acids in neonatal blood samples based on derivatization with isobutyl chloroformate followed by solid-phase microextraction and gas chromatography/mass spectrometry.

The purpose of this study was to develop a simple, rapid and sensitive analytical method for determination of amino acids in neonatal blood samples. The developed method involves the employment of derivatization and a solid-phase microextraction (SPME) technique together with gas chromatography/mass spectrometry (GC/MS). Amino acids in blood samples were derivatized by a mixture of isobutyl chloroformate, methanol and pyridine, and the N(O,S)-alkoxycarbonyl alkyl esters thus formed were headspace extracted by a SPME fiber. Finally, the extracted analytes on the fiber were desorbed and detected by GC/MS in electron impact (EI) mode. L-Valine, L-leucine, L-isoleucine, L-phenylanaline and L-tyrosine in blood samples were quantitatively analyzed by measurement of the corresponding N(O,S)-alkoxycarbonyl alkyl esters using an external standard method. SPME conditions were optimized, and the method was validated. The method was applied to diagnosis of neonatal phenylkenuria (PKU) and maple syrup urine disease (MSUD) by the analyses of five amino acids in blood samples. The results showed that the proposed method is a potentially powerful tool for simultaneous screening for neonatal PKU and MSUD.

Amino Acids↗

Development of an improved heated interface for coupling solid-phase microextraction to high-performance liquid chromatography.

The aim of the study described in this report has been the development and the evaluation of a new improved interface to be operated under continuous heating, for on-line coupling solid-phase microextraction (SPME) to high-performance liquid chromatography (HPLC). Heating is desirable to increase desorption rate and decrease carryover. The results obtained have been compared with that obtained by off-line desorption and online desorption without heating. The SPME-HPLC interface described here has an inner volume of 60 microL, fixation for infinite points and a novel leak less sealing system. When the heating system was used, the area values were almost 10-fold higher than that obtained using the off-line mode. The obtained chromatograms showed an increasing of the area and height of chromatographic peaks and proved the excellent performance and reproducibility of the interface developed in this work.

Chemical Fractionation↗

Headspace solid-phase microextraction--a tool for new insights into the long-term thermo-oxidation mechanism of polyamide 6.6.

Low-molecular-mass products formed during thermo-oxidation of polyamide 6.6 at 100 degrees C were extracted by headspace solid-phase microextraction and identified by GC-MS. A total of 18 degradation products of polyamide 6.6 were identified. In addition some low-molecular-mass products originating from the lubricants were detected. The identified degradation products were categorized into four groups where compounds within each group contain the same structural feature. In groups A, B and C several new thermo-oxidation products of polyamide 6.6 were identified including cyclic imides, pyridines and structural fragments from the original polyamide chain. 1-Pentyl-2,5-pyrrolidinedione (pentylsuccinimide) showed the largest increase in abundance during oxidation. The cyclopentanones in group D were already present in the un-aged material. Their amounts decreased during ageing and they are thus not formed during thermo-oxidation of polyamide 6.6 at 100 degrees C. The identified thermo-oxidation products can be formed as a result of extensive oxidation of the hexamethylenediamine unit in the polyamide backbone. The degradation products pattern shows that the long-term thermo-oxidative degradation, just like thermal degradation and photo-oxidation of polyamide 6.6, starts at the N-vicinal methylene groups.

Caprolactam↗

Quantitation of formate by solid-phase microextraction and gas chromatography--mass spectrometry utilizing a [13C]formate internal standard.

A new method for the analysis of formic acid was developed using gas chromatography-electron impact ionization mass spectrometry in the selected ion monitoring mode and solid-phase microextraction. Using this method with [13C]formic acid as an internal standard, the peak area ratio of [12C]formic acid/[13C]formic acid was not affected by differing methanol or sulfuric acid concentrations during the esterification and fiber adsorbing step. In comparison, the peak area ratio of formic acid/acetonitrile as detected by conventional GC with flame ionization detection was greatly affected by methanol or sulfuric acid concentrations. The formic acid calibration curve of our method showed excellent linearity over the range 5 to 200 microM. The within- and between-run assay relative standard deviations for the formic acid concentration were all less than 1.70%.

Calibration↗

Headspace solid-phase microextraction with 1-pyrenyldiazomethane in-fibre derivatisation for analysis of faecal short-chain fatty acids.

Short chain fatty acids (SFCAs) are nutritionally important products of colonic bacteria. Their analysis in faeces is problematic. We report a headspace solid-phase microextraction procedure in which faecal SCFAs are derivatised on the fibre in-situ with 1-pyrenyldiazomethane. With this method sharp, well-resolved chromatographic peaks were obtained with no interferences. Inclusion of deuterated analogues enabled accurate quantification. Good linearity, recoveries and precision were achieved. Differences observed between the SCFA profiles of normal subjects and patients with cystic fibrosis indicate the potential of this new technique for clinical studies. 2-Methylbutyric acid was found in all faecal samples. Few have reported this before.

Case-Control Studies↗

Determination of methylmercury and butyltin compounds in marine biota and sediments using microwave-assisted acid extraction, solid-phase microextraction, and gas chromatography with microwave-induced plasma atomic emission spectrometric detection.

A method is described for the determination of methylmercury and butyltin compounds in marine sediment and tissue using microwave-assisted acid extraction or digestion and solid-phase microextraction (SPME) followed by analysis using gas chromatography with microwave-induced plasma atomic emission spectrometric detection (GC-MIP-AES). Using the SPME-GC-MIP-AES method, enrichment factors for methylmercury and butyltin compounds of 50-100 were achieved, as compared to the typical hexane extraction, and measurements in marine tissue and sediment matrixes were possible at 1-2 microg/kg (methylmercury) and 10-100 ng/kg (butyltins). The SPME-GC-MIP-AES method was validated using several marine sediment and tissue matrix certified reference materials (CRMs) with certified values for methylmercury and butyltin compounds. The SPME-GC-MIP-AES method was used to measure methylmercury in four marine tissue CRMs ranging from oyster tissue at 13.0 +/- 1.0 microg/kg to fish tissue at 397 +/- 13 microg/kg (as Hg dry mass). Results from the SPME-GC-MIP-AES method were used in conjunction with results from other techniques to assign certified values for methylmercury in oyster, mussel, and fish tissue CRMs. Mono-, di-, and tributyltin were measured in three sediment CRMs at concentration levels of (0.08 +/- 0.03)-(0.35 +/- 0.05) mg/kg (as Sn dry mass).

Animals↗

Solid-phase microextraction for the determination of pethidine and methadone in human urine using gas chromatography with nitrogen-phosphorus detection.

A simple and rapid analytical method is presented for the determination of pethidine (meperidine) and methadone in human urine using solid-phase microextraction (SPME) and gas chromatography with nitrogen-phosphorus detection (GC-NPD). After the analytes had been partitioned between an extracting phase and the aqueous sample matrix, the needle of the coating fiber assembly was injected directly into the GC injector. The analytes were thermally desorbed in the heated injector (240 degrees C) and subsequently separated and detected by the GC-NPD system. The factors influencing the SPME method, such as the salt (NaCl) effect (15%), pH (pH 11), and equilibration time (30 min), were optimized. The calibration graphs for urine samples showed a good linearity. The detection limit was below 1 ng ml-1 for both drugs.

Chromatography, Gas↗

The comparison of toluene determination between headspace-solid phase microextraction and headspace methods in glue-sniffer's blood and urine samples.

An accurate and simple method was developed to determine the level of toluene in urine and blood quantitatively by using the gas chromatography/mass spectrometry (GC/MS) with headspace--solid phase microextraction (HS-SPME) technique. An assembly of SPME with a replaceable extraction fiber, coated with 100 microm polydimethylsiloxane, was used. The detection limit of toluene in blood and urine with HS-SPME technique was 10 times higher than that with headspace (HS) technique. To compare the HS-SPME with HS technique for the determination of toluene in biological fluids, blood and urine samples from glue sniffers were analyzed by both methods. The level of toluene by the two techniques was highly correlated: the correlation coefficient (r2) between the two sets of values were 0.98 and 0.96 in urine and blood, respectively.

Forensic Medicine↗

High extraction efficiency fiber coated with calix[4] open-chain crown ether for solid-phase microextraction of polar aromatic and aliphatic compounds.

The calix[4] open-chain crown ether, 5,11,17,23-tetra-tert-butyl-25,27-di(2-allyloxyethoxyl)-26,28-dihydroxycalix[4]arene was synthesized and used for preparation of solid-phase microextraction (SPME) fibers of enhanced extraction efficiency. The new SPME coating made from calix[4] open-chain crown ether and hydroxyl-terminated silicone oil was developed with the aid of vinyltriethoxylsilane as bridge using sol-gel method and cross-linking technology. The efficiency of the novel fiber in the extraction of polar aromatic and aliphatic compounds, such as phenols, alcohols, and volatile fatty acids, was also investigated. Due to the introduction of the polar open-chain crown ether in calix[4]arene molecules, the calix[4] open-chain crown ether fiber showed much better selectivity and sensitivity to these polar compounds in comparison with calix[4]arene fiber. It also had superior extraction efficiency when compared to commercial poly(dimethylsiloxane)-divinylbenzene and polyacrylate fibers. Parts per billion to parts per trillion level detection limits were achieved for most of the analytes through SPME in conjunction with GC and flame ionization detector. The linear ranges were two to four orders of magnitude, and the RSD values were below 7% for all analytes. The novel fiber was applied to determine volatile alcohols and fatty acids in wine samples. The volatile-free wine prepared in this work was used to assure similar chemical environment for analytes in both calibration solutions and in real wine samples, thus compensating for possible matrix interferences. The established internal standard method using 4-methyl-2-pentanol as internal standard showed satisfactory accuracy and precision.

Alcohols↗

Quantitative analysis of 2-furfural and 5-methylfurfural in different Italian vinegars by headspace solid-phase microextraction coupled to gas chromatography-mass spectrometry using isotope dilution.

A new method was developed for the determination of 2-furfural (2-F) and 5-methylfurfural (5-MF), two products of Maillard reaction in vinegar, with head-space solid-phase microextraction (HS-SPME) coupled to gas chromatography-mass spectrometry (GC-MS). A divinylbenzene (DVB)/carboxen (CAR)/polydimethylsiloxane (PDMS) fibre was used and SPME conditions were optimised, studying ionic strength effect, temperature effect and adsorption time. Both analytes were determined by calibration established on 2-furfural-d4 (2-F-d4). The method showed good linearity in the range studied (from 16 to 0.12 mg/l), with a regression coefficient r2 of 0.9999. Inter-batch precision and accuracy were found between 14.9 and 6.0% and between -11.7 and 0.2%, respectively. Detection limit was 15 microg/l. The method is simple and accurate and it has been applied to a series of balsamic and non-balsamic vinegars.

Acetic Acid↗

Rapid determination of essential oil in Acorus tatarinowii Schott. by pressurized hot water extraction followed by solid-phase microextraction and gas chromatography-mass spectrometry.

A simple, rapid, efficient and inexpensive method for the determination of essential oil in a traditional Chinese medicine (TCM), Acorus Tatarinowii Schott. was developed by using pressurized hot water extraction (PHWE) combined with solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS). Acorus Tatarinowii Schott. (0.050 g) was subjected to dynamic extraction with water at 50 bar, 150 degrees C and 1.0 ml/min for 5.0 min, and then the essential oil in the aqueous extract were extracted by SPME fibers at 60 degrees C for 10 min, finally the compounds on the fiber were desorbed and analyzed by GC-MS. The PHWE and SPME parameters were studied. The key active compound of alpha-asarone in the TCM samples from three different growing areas was quantitatively analyzed by external standard method. Compared to steam distillation (SD), the proposed method required little time (only 15 min) to prepare sample. Moreover, little sample mass and no organic solvent was needed. The present method provided good repeatability (R.S.D. less than 13.0%) and recovery (92% for alpha-asarone). It has been shown that PHWE-SPME-GC-MS is an alternative method for determination of essential oils in TCMs and a potential tool for TCM quality assessment.

Acorus↗

Application of gas chromatography coupled to chemical ionisation mass spectrometry following headspace solid-phase microextraction for the determination of free volatile fatty acids in aqueous samples.

Gas chromatography coupled to positive and negative ion chemical ionisation mass spectrometry was evaluated for the determination of free volatile fatty acids (VFAs) from aqueous samples by headspace solid-phase microextraction. Negative ion chemical ionisation in the selected ion monitoring mode using ammonia as reagent gas provided acceptable sensitivity and the highest selectivity for the determination of C2-C7 fatty acids using a polydimethylsiloxane-Carboxen fibre. Detection limits in the range of 150 microg l(-1) for acetic acid and from 2 to 6 microg l(-1) for the remaining carboxylic acids were achieved. The reproducibility of the method was between 9 and 16%. The developed analytical procedure was applied to the analysis of VFAs in raw sewage. The absence of interfering peaks provided a more accurate determination of acetic, propionic, butyric and isovaleric acids than a similar analytical scheme but using a flame ionisation detector.

Fatty Acids, Nonesterified↗

Sorption of phenols to dissolved organic matter investigated by solid phase microextraction.

The sorption of phenol and different halogenated phenols to natural organic matter of a brown water lake (HO14), of a compost extract, of Aldrich humic acid (Aldrich-HA), and to the protein bovine serum albumin (BSA) was investigated using solid phase microextraction (SPME). The limit of determination for the SPME analysis was < 15 microg/l for all phenols investigated. The extraction coefficients K(F) were calculated according to a first-order extraction kinetics. In general, the extraction equilibrium was established faster due to the presence of dissolved organic matter (DOM). The highest sorption capacity of phenols was observed for BSA with log K(OC) values in the range between 2 and 6. For the compost extract and HO14 only a small sorption of the investigated phenols was determined. On the other hand, Aldrich humic acid showed a reasonable sorption of phenols with log K(OC) values between 2 and 3. The sorption to DOM decreased when the pH of the solution was increased.

Adsorption↗

Solid phase microextraction application in gas chromatography/olfactometry dilution analysis.

Gas chromatography/olfactometry (GC/O) based on dilution analysis (e. g., CharmAnalysis or aroma extraction dilution analysis) gives an indication of what compounds are most important (most potent) to the aroma of foods. The application of solid phase microextraction to the preparation of samples for GC/O dilution analysis was shown to be feasible by varying the fiber thickness and length to achieve various absorbant volumes.

Aldehydes↗

Automated on-line in-tube solid-phase microextraction followed by liquid chromatography/electrospray ionization-mass spectrometry for the determination of chlorinated phenoxy acid herbicides in environmental waters.

A method for the determination of six chlorinated phenoxy acid herbicides in river water was developed using in-tube solid-phase microextraction (SPME) followed by liquid chromatography/electrospray ionization-mass spectrometry (LC/ESI-MS). In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from a sample directly into an open tubular capillary by repeated draw/eject cycles of the sample solution. Simple mass spectra with strong signals corresponding to [M-H]- and [M-RCOOH]- were observed for all herbicides tested in this study. The best separation of these compounds was obtained with a C18 column using linear gradient elution with a mobile phase of acetonitrile-water containing 5 mmol l-1 dibutylamine acetate (DBA). To optimize the extraction of herbicides, several in-tube SPME parameters were examined. The optimum extraction conditions were 25 draw/eject cycles of 30 microliters of sample in 0.2% formic acid (pH 2) at a flow rate of 200 microliters min-1 using a DB-WAX capillary. The herbicides extracted by the capillary were easily desorbed by 10 microliters acetonitrile. Using in-tube SPME-LC/ESI-MS with time-scheduled selected ion monitoring, the calibration curves of herbicides were linear in the range 0.05-50 ng ml-1 with correlation coefficients above 0.999. This method was successfully applied to the analysis of river water samples without interference peaks. The limit of quantification was in the range 0.02-0.06 ng ml-1 and the limit of detection (S/N = 3) was in the range 0.005-0.03 ng ml-1. The repeatability and reproducibility were in the range 2.5-4.1% and 6.2-9.1%, respectively.

Chromatography, Liquid↗

Analysis of the volatile components of five Turkish Rhododendron species by headspace solid-phase microextraction and GC-MS (HS-SPME-GC-MS).

Volatile constituents of various solvent extracts (n-hexane, CH2Cl2, H2O) of 15 different organs (leaves, flowers, fruits) of five Rhododendron species (Ericaceae) growing in Turkey were trapped with headspace solid-phase microextraction (HS-SPME) technique and analyzed by GC-MS. A total of 200 compounds were detected and identified from organic extracts, while the water extracts contained only traces of few volatiles. The CH2Cl2 extract of the R. luteum flowers was found to exhibit the most diverse composition: 34 compounds were identified, with benzyl alcohol (16.6%), limonene (14.6%) and p-cymene (8.4%) being the major compounds. The CH2Cl2-solubles of R. x sochadzeae leaves contained only phenyl ethyl alcohol. This study indicated appreciable intra-specific variations in volatile compositions within the genus. Different anatomical parts also showed altered volatile profiles. This is the first application of HS-SPME-GC-MS on the volatiles of Rhododendron species.

Benzyl Alcohol↗

Applicability of solid-phase microextraction followed by on-fiber silylation for the determination of estrogens in water samples by gas chromatography-tandem mass spectrometry.

A solvent-free method for the determination of five estrogens in water samples at the low ng/l was optimized. Compounds were first concentrated on a polyacrylate (PA) solid-phase microextraction (SPME) fiber, directly exposed to the water sample, and then on-fiber silylated on the headspace of a vial containing 50 microl of N-methyl-N-(trimethylsilyl) trifluoroacetamide (MSTFA). Derivatized analytes were determined using GC with MS/MS detection. Influence of several factors on the efficiency of the microextraction step (e.g. time, sample volume, pH, ionic strength and fiber coating) is systematically described. Derivatization conditions were optimized in order to achieve the complete silylation of all hydroxyl groups contained in the structure of the compounds. Detection limits (from 0.2 to 3 ng/l) are compared with those obtained using the same detection technique and different sample preparation strategies, such as solid-phase extraction followed by silylation of the analytes in the organic extract and SPME without derivatization. The method was applied to the analysis of sewage water samples. Two of the investigated species were detected above the quantification limits of the procedure.

Estrogens↗