At least 721 records · Page 40Linked to original sources

Surgical management of congenital and acquired pulmonary vein stenosis.

Pulmonary vein stenosis describes a variety of entities with a variable clinical course. The basic pathologic process appears to be fibrous intimal thickening, which can gradually cause obliteration of the lumen of the pulmonary veins at the atrial junction. In its most severe form, congenital pulmonary vein stenosis is a progressive disease with rapid pulmonary hypertension and rare survival beyond the first year of life. Surgical intervention has not been successful in this group. Other forms of pulmonary vein stenosis, including unilateral types associated with congenital heart disease, may be managed by various surgical treatments or pneumonectomy in some cases. Although multiple surgical techniques have been described for repair of congenital vein stenosis, the "sutureless" techniques recently described may have a place in the surgical treatment of this condition. In the most severe forms, lung transplantation appears to be an important option that should be considered early in the course of the disease. Copyright 1999 by W.B. Saunders Company

Journal Article↗

Phacoemulsification at King Khaled Eye Specialist Hospital--the experience of the past.

OBJECTIVE: To study the outcome of phacoemulsification (PE) compared to standard extracapsular surgery before the introduction of state-of-the-art techniques (capsulorhexis, hydrodissection, nuclear cracking, nuclear chopping, sutureless incisions) and sophisticated equipment. STUDY DESIGN: Charts from 375 patients (453 eyes) undergoing PE between 1984 and 1989 were randomly selected and studied retrospectively. A minimum age of 35 years, and a minimum follow-up of three months were required. SETTING: A large eye hospital in the Kingdom of Saudi Arabia staffed with an international faculty of ophthalmic surgeons. PATIENTS: Patients over 35 years of age undergoing PE for immature, mature and traumatic cataract. MAIN OUTCOME MEASURES: Postoperative visual acuity, and rate or frequency of intraoperative complications. RESULTS: 66.5% achieved visual acuity of 20/40 or better, which compares favourably with the 36.5% of eyes reaching this level of visual acuity after mainly standard extracapsular cataract surgery in another study at our hospital. Posterior capsule ruptures occurred in 7.5% and vitreous loss in 5.5%. Other ocular disease (odds ratio 7.51 confidence interval 4.43-12.7) and intraoperative complications (odds ratio 2.97 confidence interval 1.38-6.42) were statistically significant predictors for final visual acuity of under 20/40 (p = < 0.001 and 0.005 respectively). CONCLUSION: The outcome of PE was better than that of standard extracapsular cataract extraction in the same setting. However, since PE appeared to be used selectively, no clear advantage compared to extracapsular cataract extraction is evident in the period before the introduction of modern state-of-the-art PE-techniques.

Adult↗

The GraftConnector experience. Long-term patency and histological work up in an animal model.

BACKGROUND: A device to perform sutureless end-to-side coronary artery anastomosis has been developed by means of stent technology (GraftConnector). The present study assesses the long-term quality of the GraftConnector anastomosis in a sheep model. METHODS: In 8 adult sheep, 40-55 kg in weight, through left anterior thoracotomy, the right internal mammary artery (RIMA) was prepared and connected to the left anterior descending artery (LAD) by means of GraftConnector, on beating heart, without using any stabilizer. Ticlopidine 250 mg/day for anticoagulation for 4 weeks and Aspirin 100 mg/day for 6 months were given. The animals were sacrificed after 6 months and histological examination of anastomoses was carried out after slicing with the connector in situ for morphological analysis. RESULTS: All animals survived at 6 months. All anastomoses were patent and mean luminal width at histology was 1.8 +/- 0.2 mm; mean myotomia hyperplasia thickness was 0.21 +/- 0.1 mm. CONCLUSIONS: Long-term results demonstrate that OPCABGs performed with GraftConnector had 100% patency rate. The mean anastomotic luminal width corresponds to mean LAD's adult sheep diameter. We may speculate that myotomia hyperplasia occurred as a result of local device oversizing.

Animals↗

Discharging routine phacoemulsification patients at one week.

The reduction of surgically induced astigmatism and rapid refractive stabilisation after phacoemulsification have been well studied and often lead to reduced follow-up. In this prospective study we reviewed a cohort of 100 patients discharged with a refractive prescription at their 1 week post-operative appointment following routine sutureless phacoemulsification through a corneal or scleral section. The aim was to assess the incidence of late pathology and need for review. Eighty-eight patients attended for review between 3 and 4 months post-operatively, of whom 8 (9.1%) who had been symptomatic had already visited ophthalmic casualty. Nine (10.2%) benefited from the follow-up appointment: 4 were given a new refractive prescription that increased their Snellen visual acuity by 1 line; the other 5 were all symptomatic or had incidental findings. We feel that provided there is easy access to the eye department, early discharge with or without refraction is justifiable as those with surgically related pathology at any stage are symptomatic.

Emergency Service, Hospital↗

Randomised fellow eye comparison of the effectiveness of dorzolamide and apraclonidine on intraocular pressure following phacoemulsification cataract surgery.

PURPOSE: To compare the effectiveness of 2% dorzolamide and 0.5% apraclonidine on intraocular pressure (IOP) following phacoemulsification cataract surgery. METHODS: This prospective, randomised study comprised 54 eyes of 27 consecutive patients with age-related cataract scheduled for cataract surgery in both eyes. In each patient the eye with the higher degree of cataract was randomly assigned to receive one drop of either dorzolamide or apraclonidine immediately after surgery. The fellow eye was operated on later and received the other treatment. Cataract surgery was performed with a superior 6.0 mm sutureless frown incision, phacoemulsification and implantation of a three-piece PMMA intraocular lens. The IOP was measured pre-operatively as well as 6 h and 20-24 h and 1 week post-operatively. RESULTS: The mean pre-operative IOP was not significantly different between the groups (dorzolamide group, 14.9 +/- 2.3 mmHg; apraclonidine group, 14.6 +/- 2.5 mmHg; p = 0.450). At 6 h post-operatively, the mean IOP was significantly lower in the dorzolamide than in the apraclonidine group (15.6 +/- 3.9 mmHg vs 18.0 +/- 4.0 mmHg; p < 0.001). An IOP increase of more than 5 mmHg at 6 h post-operatively occurred in 3 (12%) eyes in the dorzolamide group and in 9 (36%) eyes in the apraclonidine group (p = 0.034). At 20-24 h post-operatively and at 1 week post-operatively no difference was found between the groups. CONCLUSIONS: 2% Dorzolamide is more effective than 0.5% apraclonidine in preventing the early post-operative IOP increase following phacoemulsification cataract surgery.

Adrenergic alpha-Agonists↗

Hydroview lens implant calcification: 186 exchanges at a district general hospital.

AIM: This paper describes the experience at a district general hospital of coping with an abrupt onset of calcification of Hydroview intraocular lens (IOL) implants requiring exchange surgery mostly for symptoms of glare, even though the visual acuities were relatively good. METHODS: In this retrospective study, the operative details of 174 consecutive lens exchanges by one surgeon were retrieved from the surgeon's notes. Of these, pre and post-operative details of 106 consecutive patients were obtained from the hospital notes. RESULTS: Of the 174 lens exchanges, all were sutureless except one and 31 eyes (18%) had had previous capsulotomies. Of 143 eyes with intact posterior capsules, eight (5.6%) needed anterior vitrectomy. Lens replacements were in the bag in 136 (95%), in the sulcus in five (3.5%), and in the anterior chamber in two (1.5%). Of the 31 eyes with previous capsulotomies, 10 (32%) needed anterior vitrectomy. Lens replacements were in the bag in 22 (71%) and in the sulcus in the remaining nine cases (29%). Postoperatively the best-corrected visual acuity was improved in 53%, remained the same in 35%, and deteriorated in 12%. CONCLUSION: The lens exchange procedure was mostly predictable with satisfactory visual results allowing preoperative counselling of risks to be similar to that for cataract surgery. The onset and resolution of the period of implantation of lenses requiring exchange has not been explained.

Aged↗

Two-year follow-up of meniscal repair using a bioabsorbable arrow.

PURPOSE: The value of meniscal repair is well established. Several all-inside arthroscopic techniques have become available to achieve this goal. One such technique involves the use of a biodegradable polylactic acid tack, which has made repair technically easier to perform. This study evaluates the 2-year results of arthroscopic meniscal repair using this device. TYPE OF STUDY: Retrospective case series. METHODS: We reviewed charts of 38 patients who had undergone 39 meniscal repairs with the bioabsorbable arrow. All procedures were performed by one of 4 fellowship-trained sports medicine orthopaedic surgeons in 1 of 2 affiliated hospitals, with a minimum follow-up of 2 years. Review consisted of evaluation of patient records, interview, and clinical examination by an independent examiner. Lysholm and Tegner knee scores were recorded. Complications and clinical failure, defined as reoperation, were noted. RESULTS: The average age of the patients was 29.9 years. The ratio of medial to lateral meniscal repair was 5:1. Twenty-one patients underwent concurrent anterior cruciate ligament reconstruction, and in this subgroup, there were no clinical failures. In the remaining group, isolated meniscal repairs in stable knees, the clinical failure rate was 7% (2 reoperations). Local soft-tissue complications occurred in 31.6% of patients, including 2 with arrow migration through the skin. These symptoms typically resolve over several months. CONCLUSIONS: The availability of sutureless all-inside absorbable techniques for meniscal repair has made the procedure technically easier to perform arthroscopically. In our patients, local complications related to device migration, device prominence, and soft-tissue inflammation associated with absorption of the device were common (31.6%). These complications were usually transient. We emphasize the importance of selecting the correct length of device so as to minimize these effects. As with other meniscal repair techniques, a higher success rate was found in knees undergoing concurrent anterior cruciate ligament reconstruction. Our results show a clinical success rate using an absorbable all-inside technique with an absorbable device comparable to reported results using established inside-out techniques.

Absorption↗

Percutaneous endoscopic gastrostomy-20 years later: a historical perspective.

BACKGROUND/PURPOSE: Percutaneous endoscopic gastrostomy (PEG), initially developed for children with inability to swallow, had its first presentation at the annual meeting of the American Pediatric Surgical Association in Florida in 1980. Based on the novel concept of the sutureless approximation of a hollow viscus to the abdominal wall, this minimally invasive procedure has become the standard for direct gastric access worldwide. This report is a brief retrospective about the evolution of PEG and the expanded applications of the surgical concept on which it is based. METHODS: Information related to PEG was obtained from personal records, a focused literature search, and data from various registries and the industry. RESULTS: The search identified 836 peer-reviewed publications directly related to PEG. The original Journal of Pediatric Surgery article has received 483 bibliographic citations. The procedure has had a profound impact on nutritional management, particularly among adult patients. Over 216,000 PEGs are performed annually in the United States. Twelve major manufacturers produce PEG or PEG-related enteral access devices. Select expanded applications of PEG and its principle include indications beyond feeding, use in high-risk patients, percutaneous jejunostomy, percutaneous cecostomy, correction of gastrostomy leakage and gastric volvulus, multiple PEG portals for intragastric interventions, and laparoscopically assisted gastrostomies. CONCLUSIONS: Over 20 years, percutaneous endoscopic gastrostomy has experienced exponential growth. Improved guidelines and technical refinements have added to its safety. The concept on which it is based has created a ripple effect and led to numerous applications beyond gastric access for feeding. In an era when so many of our procedures are adopted from "adult" general surgery, it is worthwhile to have an historical perspective on PEG, a technique that originated in pediatric surgery.

Bibliometrics↗

Use of intraluminal stents in multiple intestinal atresia.

Multiple intestinal atresia presents a difficult technical problem because of extreme loss of intestinal length, disparity of residual bowel wall size, and discontinuity of multiple short intestinal segments. The authors report on a 3,000-g infant with gastroschisis complicated by intrauterine volvulus and multiple intestinal atresias who was treated successfully with intraluminal stenting and sutureless anastomoses. A total of 25 cm of small bowel was salvaged including 13 segments each measuring 1 to 8 cm in length. Subsequent radiographic studies showed spontaneous anastomosis with a compartmental configuration of the residual bowel and decreased transit time. Five months postoperatively, the patient was weaned off total parenteral nutrition completely and one year later is growing and gaining weight with 4 to 6 bowel movements per day.

Abnormalities, Multiple↗

Traditional Preperitoneal Approach to Inguinal Hernias.

The preperitoneal approach desirably and advantageously permits direct exposure to transversalis fascia without disturbing the inguinal canal structures and allows restoration of the integrity of this layer in a anatomical, tension-free, and sutureless manner. The essential feature of prosthetic versus nonprosthetic repair of inguinofermoral hernias is the replacement of the transversalis fascia by a large mesh that extends far beyond the borders of myopectineal orifice unnecessary. Therefore, the indications for preperitoneal prosthetic repair include all recurrent and multiply recurrent groin hernias, and bilateral hernias in older patients.

Journal Article↗

Percutaneous endoscopic gastrostomy and the evolution of contemporary long-term enteral access.

This paper is based on the opening lecture of the 23rd Congress of the European Society of Parenteral and Enteral Nutrition (ESPEN), given on September 9, 200l in Muenchen, Germany. The article relates the story of the origin and the evolution of the percutaneous endoscopic gastrostomy or PEG, based on the then-novel concept of sutureless approximation of a hollow viscus to the abdominal wall. It also provides a perspective of the clinical applications of PEG, in general, and the author's pediatric experience in particular. Additionally, it briefly describes the old and new expanded applications of the PEG concept. In this communication, the author of the procedure encourages young investigators to ask relevant questions in research and in clinical settings aimed at developing new ideas and concepts in the field of nutrition. He also stresses the need to carefully reflect upon the ethical and moral implications of new discoveries. The article contains pertinent illustrations and bibliographic references.

Adult↗

Experimental lung transplantation using non-penetrating vascular clips for anastomosis of the pulmonary artery.

BACKGROUND: Reliable and rapid anastomosis is critical in lung transplantation. The purpose of this study is to show the appropriateness of sutureless anastomosis of the pulmonary artery using a nonpenetrating vascular clipping device. METHODS: The left lung was excised and the cranial lobe was transplanted autologously in 9 dogs. The anastomosis of the left main pulmonary artery (PA) (1 cm) was performed using a vascular clipping system. RESULTS: PA anastomosis was performed in 7 dogs in 8 to 13 minutes. The endovascular surface of the anastomotic site was smooth, and passage of silicone rubber through the anastomosis was good 14 or 28 days after surgery. Microscopic examination of the anastomotic sites showed excellent healing without evidence of intimal hyperplasia. CONCLUSIONS: The vascular clipping system facilitates anastomosis of the PA in lung transplant surgery.

Anastomosis, Surgical↗

Routine contralateral orchiopexy for children with a vanished testis.

AIM: The aim was to determine whether routine contralateral orchiopexy is justified in a child with a vanished testis from intrauterine torsion. METHODS: A retrospective study of thirty-one consecutive boys with a vanished testis who underwent contralateral orchiopexy with the sutureless technique over an eight-year (1995 - 2002 inclusive) period was carried out. Operative findings were analyzed. All patients have been followed to date and interviewed by telephone. RESULTS: Of the thirty-one patients, 22 had testicular abnormalities (71 %). Five patients (16 %) had abnormalities that could predispose them to metachronous torsion. These included bell clapper deformity (3), horizontal lie (1), and ectopic testis (1). Other abnormalities were abnormal epididymal-testicular fusion (2), hydrocele (2), and one testis did not show compensatory hypertrophy. CONCLUSIONS: Sixteen percent of patients had testicular abnormalities that could predispose them to metachronous torsion. There was no morbidity from the operation and no post-orchiopexy torsion on follow-up. Therefore, routine contralateral orchiopexy in a boy with a vanished testis appears to be safe and effective. A large multicenter trial should be done to investigate these preliminary findings. If confirmed, contralateral orchiopexy should be advocated.

Child↗

Comparison of nerve repair techniques: suture vs. avitene-polyglycolic acid tube.

A study was designed to determine whether a completely sutureless technique of nerve repair using avitene and polyglycolic acid (PGA) tube could provide a better repair than the standard suture repair technique. Randomized peroneal nerves of 18 male Sprague-Dawley rats were used. The study was divided into two parts. The first part was designed to test the adhesive and tensile strength of avitene at the second postoperative day in seven animals. The tensile strength of the suture repair at 498 mN +/- 130 was found to be statistically equivalent (p = 0.77) to the repair using avitene and PGA tube at 474 mN +/- 192. The second part of the study evaluated axonal regeneration in 11 animals. Evaluation by electrophysiology revealed a significant difference (p = 0.05) between the mean percentage of Integrated Mean Compound Action Potential for the suture repaired nerve (53.1 +/- 17.6 percent) and that of the avitene and PGA tube repaired nerve (72.0 +/- 17.9). The mean axonal count and mean fiber diameter for the suture repair technique (1,879 +/- 225 and 4.3 +/- 0.4 microns, respectively) were not significantly different (p = 0.61 and 0.67, respectively) from those of the avitene-PGA tube repair technique (1,938 +/- 398 and 4.2 +/- 0.4 microns, respectively).

Animals↗

Morphofunctional evaluation of fibrin glue versus microsuture nerve repairs.

Complications of microsuture repair of peripheral nerves include mechanical trauma, foreign body reaction, impairment of vascularity, and possible obstruction to successful sprouting. In addition, there are occasions when it is virtually impossible to perform a suture repair because of limited exposure and/or very fine structures, such as are encountered in pediatric cases. These situations have continued to provide the impetus for evaluating alternative methods of nerve coaptation. Recently, the use of tissue glue has gained in popularity as a technique for sutureless nerve repairs. We decided to test the efficacy of fibrin glue repair versus microsuture coaptation in the rat sciatic model. The repair sites were assessed for tensile strength, by quantitative morphometry, and by electrophysiologic studies. Tensile strength findings revealed that at two, four, and eight weeks after surgery, there was no significant difference between the two repair techniques, although there was a trend toward a stronger hold in the microsuture repairs. Electrophysiologic recordings revealed that conventional microsuture repairs had significantly faster conduction velocities, larger area under the curve, and higher peak amplitudes. The onset and peak latencies were comparable, revealing that the axonal quality of at least a certain number of axons was similar electrically. Axonal counts both proximal and distal to the repair showed no significant difference, although there was an overall suggestion of superiority in the number of myelinated axons in the suture repair.

Action Potentials↗

Is laser nerve repair comparable to microsuture coaptation?

Efforts to improve functional recovery following nerve injury and repair have included studies of sutureless repairs. The rat sciatic nerve was used as an experimental model to compare the efficacy of laser nerve repairs with standard microsuture repairs. Electrophysiologic (Compound Action Potential), quantitative morphometric, and behavioral (toe spread) measurements were used for assessment, and tensile strength of the repairs was also determined. Electrophysiologic studies showed that microsuture-repaired nerves had significantly faster conduction velocities, but the areas of the waveforms and peak amplitudes showed no significant differences between the two repair groups. Axon counts revealed significant differences in the suture group proximal to the repair site, contrasted with laser repairs. Toe spread evaluations, carried out at three day intervals, demonstrated a significant difference between the two methods of repair in only three out of 22 test dates: in these isolated cases, the suture group measurements were superior. The tensile strength findings confirmed that, at four days, microsuture repair was significantly stronger but thereafter, there was no difference between the two nerve repair techniques.

Action Potentials↗

A comparative study of median sternotomy and standard thoracotomy wound skin closure methods.

Complications from skin closure after median sternotomy or standard thoracotomy incision, although uncommon, may be the source of undesireable morbidity and even death. A prospective randomized study of 3 different methods of wound skin closure has been carried out in 205 patients undergoing cardiothoracic surgery. These methods were: 1. continuous nylon vertical mattress suture; 2. continuous subcuticular absorbable (Dexon) suture; 3. adhesive sutureless skin closure (Op-Site). All wounds were examined by independent observers at 5, 10 and 45 days after operation, and the findings were graded from 0 to 4. At 5 days, assessments were made of inflammation, edema, discharge and infection. At 10 days, attention was paid to the state of wound healing, and at 45 days to the final cosmetic appearance. The use of continuous subcuticular Dexon suture resulted in less discharge than Op-site (p less than 0.001) and less swelling or redness than nylon (p less than 0.001). Assessment of the final cosmetic appearance of the wound 6 weeks following surgery showed subcuticular Dexon to be superior to either nylon (p less than 0.01) or Op-site (p less than 0.01).

Adhesives↗