PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Device Removal”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

The Compass Elbow Hinge: indications and initial results.

The Compass Elbow Hinge uses Illizarov's methods of fixation to externally hold the elbow reduced and allow both passive and active motion. Eleven patients with degenerative disease, contracture or instability were treated with the Compass Elbow Hinge and were retrospectively evaluated at an average follow-up of 29 months (range: 18-62 months). One was lost to follow-up. Patients with degenerative changes underwent fascia lata interposition while those treated for contractures underwent anterior and posterior capsular release with or without fascia lata interposition. Those with elbow instability underwent ligament reconstruction. The device was removed after 6 weeks and seven of the 11 patients were satisfied with the outcome of the operation. Stability could not be achieved in two patients with coronoid fractures that were not reconstructed. One patient did not tolerate the device and requested its removal with subsequent subluxation. We conclude that patient selection and compliance are key elements in achieving a satisfactory outcome with the device.

Adult↗

Weaning from mechanical support in a patient with acute heart failure and multiple sclerosis.

We describe a 19-year-old woman developing acute left ventricular heart failure during her first exacerbation of multiple sclerosis. Histopathologic examination of myocardial tissue showed extensive myocytolysis. A left ventricular assist device was implanted. Three months later the cardiac function was restored and the left ventricular assist device was explanted. After 1 year the patient still remains well and her cardiac function is normal.

Acute Disease↗

Corrosion and late infection causing delayed paraparesis after spinal instrumentation.

A 28-year-old female patient came to our hospital 14 years after surgical correction of adolescent idiopathic scoliosis with a 316L stainless-steel instrumentation. She presented progressive paraparesis during the last 2 months. Plain radiography, computed tomography scan and computed tomography-scan-guided needle biopsy revealed that a metallotic mass penetrated into the spinal canal, causing compression of the spinal cord at the T5-T6 level. The patient's symptoms were related to corrosion of the implant and infection by Propionibacterium acnes. Through a posterior approach, the instrumentation was retrieved and the metallotic mass and tissues were excised. Six months after the surgery, the patient is completely asymptomatic. Corrosion of stainless-steel implants is a finding more common than supposed. Biocorrosion--or microbially influenced corrosion--is a concept to be taken into account. It is possible that bacteria may modify the rate of corrosion of metals. Early diagnosis of corrosion is essential in order to prevent cases like the one we report, and perhaps, as suggested for total hip arthroplasties, metal levels could be useful to monitor spinal implants.

Adult↗

Hemolysis during percutaneous mechanical thrombectomy can mimic a hemolytic transfusion reaction.

BACKGROUND: Interventional radiologists have developed percutaneous mechanical thrombectomy (PMT) devices to remove intravascular thrombi. Hemolysis, secondary to thrombus destruction from these devices, has been described in radiology journals, but similar reports appear to be lacking in the transfusion medicine literature. Two cases of hemolysis after PMT are described that involved the transfusion service, one of which was reported as a hemolytic transfusion reaction. CASE REPORTS: The first patient received 4 units of red cells (RBCs) during a thrombectomy and subsequent placement of a transjugular intrahepatic portosystemic shunt. The patient developed hemoglobinuria, and it was reported to the blood bank as a possible hemolytic transfusion reaction. After RBC mismatch and bacterial contamination were excluded, the hemolysis was attributed to thrombectomy-related mechanical hemolysis. In the second case, a hemolyzed sample was sent to the blood bank for a type and cross-match. Upon requesting that the sample be redrawn, it was learned that the sample was obtained after PMT. CONCLUSION: Patients who have undergone PMT can have clinical and laboratory findings suggestive of hemolytic transfusion reactions. Although interventional radiologists are familiar with these side effects, the blood bank profession needs to be aware that these procedures cause nonimmune hemolysis and must consider this possibility when evaluating transfusion reactions in these patients.

Aged↗

The link between the peel force of adhesive dressings and subjective discomfort in volunteer subjects.

OBJECTIVE: The study compared the level of discomfort experienced by healthy volunteers on the removal of a range of adhesive wounds. METHOD: This was an open, within subject comparative study of six adhesive dressings in 24 volunteers. The test site was the lower back. Allocation of test materials to the test sites was randomised. The peel force of removal was recorded after 24 hours of application using a device that removed the dressing at a constant speed and angle to the skin surface. The discomfort experienced at each removal was assessed by the subjects themselves using an electronic visual analogue scale. RESULTS: Overall, Mepilex Border was given a significantly lower discomfort score (p < or = 0.01) by the subjects than the other dressings. There were no clear differences between the five other products tested. Tielle and Allevyn Adhesive had significantly higher (p < or = 0.05) peel force than the other products. Mepilex Border caused less discomfort on removal than Duoderm Extra Thin, Biatain and Versiva, even though the peel force was similar. Tielle and Allevyn had higher peel force, but the levels of discomfort were not significantly higher for these products. CONCLUSION: It may be that the level of discomfort experienced by subjects on removal of an adhesive dressing is not entirely dependent on the peel force and that other aspects of the interaction of the skin surface and adhesive play a role.

Adhesives↗

[Post-myocardial infarction ventricular aneurysm and intractable ventricular tachycardia supported by left ventricular assist device: a case report].

A 57-year-old man was admitted under a diagnosis of myocardial infarction. Cardiac catheterization revealed total occlusions of the right coronary artery and the left anterior descending artery, and ventriculography showed aneurysmal change in the anterior and septal segments. Circulatory support was introduced with intraaortic balloon pumping, but intractable ventricular tachycardia developed. Electrophysiological mapping and cryoablation to the myocardium were performed intraoperatively, and then coronary artery bypass grafting with endoventricular circular patch plasty of the left ventricle was carried out. Weaning from the cardiopulmonary bypass was attempted, but a left ventricular assist device was subsequently implanted to support the deteriorated ventricular function. The hemodynamics of the ventricle improved several days after the circulatory support was introduced, and the left ventricular assist device was removed successfully. This case suggests that the left ventricular assist device is an effective method to support recovery from serious complications after myocardial infarction.

Cardiac Surgical Procedures↗

Intrauterine fragmentation of Gyne T380: an uncommon complication.

A case of intrauterine fragmentation of a Gyne T380 intrauterine device (IUD) is described that was detected during removal of the device. Pelvic ultrasound failed to detect the fragment. Subsequently the woman reported spontaneous expulsion of the device. A description of this uncommon complication of IUD use, diagnosis, management and the need for awareness of the possibility of spontaneous expulsion of the fragment are discussed.

Adult↗

A preliminary report on a method for studying the permeability of expanded polytetrafluoroethylene membrane to bacteria in vitro: a scanning electron microscopic and histological study.

The technique of guided tissue regeneration using expanded polytetrafluoroethylene (ePTFE) membranes has been shown to be effective in implant dentistry (bony defects, extremely thin alveolar ridges, and implants placed in fresh extraction sockets). One of the drawbacks associated with the use of membranes is their premature exposure with consequent bacterial contamination. The aim of this study was to examine the possibility that oral bacteria migrate through the occlusive portion of ePTFE membranes and to determine the time needed for microorganisms to pass from the outer surface to the inner surface of the membranes. A removable acrylic device was adapted to the molar-premolar region of one quadrant of the jaws in each of three volunteers. Five cylindrical teflon chambers were glued to the buccal aspect of each device. The chambers were divided into two rooms separated by the inner portion of a ePTFE membrane. The outer room was open to the oral cavity allowing plaque accumulation; the inner room was isolated from the oral cavity by the ePTFE membrane. One of the 5 chambers was completely closed and used as control. The test period lasted for 4 weeks. Every week, one chamber was removed from each device and processed for scanning electron microscopic and histologic examinations. Our study showed the possibility that oral bacteria may contaminate ePTFE membranes exposed to the oral cavity. One specimen showed partial bacterial penetration after 2 and 3 weeks, but after 4 weeks, all membrane specimens demonstrated bacterial contamination.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Return to fertility in nulliparous and parous women after removal of the GyneFix intrauterine contraceptive system.

OBJECTIVE: To evaluate the return to fertility following removal of the GyneFix intrauterine implant system in women wishing to conceive. STUDY DESIGN: A retrospective study was performed on a sample of healthy, sexually active nulligravid/nulliparous and parous women. The participants were 18-41 years of age, with no apparent infertility problem, living in a stable relationship and planning to become pregnant. Women who changed their mind and did not wish to become pregnant immediately after intrauterine device (IUD) removal were excluded from the study. Women were evaluated in terms of rates of conception and fertility outcome. A total of 128 women were evaluated. RESULTS: The study shows that 119 out of 128 (93%) past users of GyneFix have conceived, accounting for a net cumulative pregnancy rate of 88% at 12 months and 99% after 2 years' observation. No statistical differences in pregnancy rates were found for age and duration of use of the IUD. A strong significant difference in pregnancy rate was shown (p = 0.007) between parous and nulligravid/nulliparous women. Seventy-seven women (66.9%) gave birth to a term infant. There were no stillbirths. Twenty-five women (21.8%) are pregnant at the time of writing. Five (4.4%) spontaneous abortions occurred and in eight women (6.9%) the pregnancy was terminated. There were no ectopic pregnancies. CONCLUSION: The results obtained compare favorably with those obtained in previous studies conducted following the removal of copper IUDs. The use of the frameless IUD does not affect future fertility in nulligravid/nulliparous and parous women wishing to become pregnant following removal of the device. Nulliparous women conceive significantly earlier than parous women.

Abortion, Induced↗

Diagnosis and management of staphylococcal infections of pacemakers and cardiac defibrillators.

Staphylococcal species, usually Staphylococcus aureus or Staphylococcus epidermidis, account for 70% to 95% of pacemaker and cardiac defibrillator infections. Infection limited to the generator pocket may cause pain, redness and swelling that is often accompanied by drainage or fistula formation. In this instance, the generator should be removed and reimplanted at another site as cure is rare with antimicrobial therapy alone. Infection of the leads usually tracks along the wire to include the endocardial surface and may involve the tricuspid valve and pocket. Clinical manifestations vary from mild chronic non-specific symptoms to septic shock with marked localizing signs. Septic embolization to the lungs is common and may cause cough, chest pain and shortness of breath that may be misdiagnosed. Blood culture and trans-oesophageal echocardiography (TOE) are the most important investigations.TOE has a sensitivity of >90%. Lead infection without vegetations may occur and these infections should be treated as for endocarditis. Antimicrobial therapy is an important part of treatment but lead infections are unlikely to cured unless the device is removed. Vancomycin is suitable as initial antimicrobial therapy as this covers both S. aureus and coagulase-negative staphylococci. Flucloxacillin, dicloxacillin or a first-generation cephalosporin are preferred if the organism is sensitive. The addition of low-dose gentamicin may improve bacterial killing. The duration of antimicrobial therapy and timing of replacement of the device have not been determined but 2 weeks treatment before removal and 2-4 weeks treatment after replacement is commonly administered.

Anti-Bacterial Agents↗

Methods for removing metal obstructions from the root canal.

The removal of metallic obstructions is an important part of endodontic retreatment procedures and encounters a number of serious problems. Sometimes removal procedures are extremely easy and can be performed in rather short time, but often it is a very tedious and time-consuming operation with a high number of failures, especially with fractured instruments. Using special devices such as the Masserannkit, the Canal-Finder-System, or ultrasonic systems some fractured instrument cases can be managed successfully. The retreatment of dowel-obturated root canals or failing silver cone cases has a good prognosis and a fairly good success rate. The Masserannkit, post pullers, the Canal-Finder-System and ultrasonic systems have been shown to be helpful devices in removal of root posts and silver cones. Additionally a large number of special devices and techniques for the removal of metal obstructions from the root canal have been described in the literature and will be critically reviewed.

Dental Debonding↗

Endoscopic protector hood for safe removal of sharp-pointed gastroesophageal foreign bodies.

Endoscopic removal of sharp and pointed foreign bodies in the upper gastrointestinal tract still poses technical difficulties. Overtubes may be uncomfortable to the patients and only objects fitting within a lumen of about 11-15 mm can be removed. We present here our preliminary experience with a commercially available new endoscopic end protector hood having the unique characteristic of maintaining its bell portion inverted during the progression of the scope through the gut and flipping back to its original shape during withdrawal through the lower esophageal sphincter. This prevents exposure of the esophageal and pharyngeal wall to injuries from the edges of the foreign body. We used this device to remove nine large sharp or pointed gastroesophageal foreign bodies in six consecutive patients in whom conventional techniques were considered unsafe or not technically feasible owing to the size and shape of the objects. In all cases, removal was successful and easily performed without bowel damage. We believe that this device enhances the safe removal of a wide variety of potentially dangerous gastroesophageal foreign bodies.

Adult↗

Quality of red blood cells using autotransfusion devices: a comparative analysis.

Cell salvage devices are routinely used to process and wash red blood cells (RBCs) shed during surgical interventions. Although the principle theory of cell saving is the same, the actual process to achieve this is very different from one device to another. The purpose of this study was to compare the quality of washed, concentrated RBC produced by five very different cell-saving devices, specifically the Cobe BRAT 2, Medtronic Sequestra 1000, Haemonetics Cell Saver 5, Medtronic Autolog, and the Fresenius CATS. Reservoir and washed red blood cells were analyzed for hematocrit (Hct), platelets (PLT), leukocytes (WBC), potassium (K+), heparin, plasma-free hemoglobin (PFH), RBC mass recovery and recovery rate. The Haemonetics and BRAT 2 had the highest RBC recovery. All devices adequately removed heparin and potassium. The Medtronic Autolog had the highest removal of platelets and PFH; whereas, the BRAT had the lowest. Although the Autolog had the highest leukocyte removal, leukocytes were not adequately washed out by any of the autotransfusion devices. In conclusion, although all cell-saving devices use the same theory of centrifugation, the actual quality of the washed RBC product differs widely from one device to another.

Blood Component Removal↗

Late implant infections caused by Propionibacterium acnes in scoliosis surgery.

One hundred and one consecutive adolescent scoliosis patients instrumented from the posterior between 1995 and 2002, with a minimum follow-up of 24 months (maximum 106 months), were reviewed for incidence of infection. Stainless steel implants with pedicle screws were used in the thoracic and lumbar spine of all patients. All were operated on by a single surgeon. There were no early infections. Incidence of late infection was 6.9% (seven patients). Clinical indicators for infection were the sudden onset of local pain and swelling without fever after an initial pain-free interval. There were no reliable laboratory parameters. Normal CRP and ESR did not rule out a late infection. Extended cultures were done from intraoperative swabs. Propionibacterium acnes was found in six patients. There were no other organisms identified. No causative organism could be identified in one patient, despite extended cultures. All patients were successfully treated with implant removal and antibiotic therapy for 4-9 weeks. No pseudarthrosis was seen on implant removal. Despite bony fusion, loss of correction between 10 degrees and 26 degrees was observed in three patients after implant removal.

Adolescent↗