PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Fluorocarbon Polymers”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

Effect of interference on the performance of glucose enzyme electrodes using Nafion coatings.

The negatively charged perfluorinated ionomer Nafion was used as a coating on hydrogen peroxide detecting platinum electrode as well as on a polycarbonate diffusion membrane in the construction of a glucose amperometric enzyme electrode. The current response of these electrodes to hydrogen peroxide, ascorbic acid, acetaminophen, uric acid and glucose was studied and the coating procedure was optimized. It was confirmed that the Nafion coating prevents interference by anionic substances such as ascorbic acid and uric acid, and decreases acetaminophen interference. In this regard it was shown that coating the glucose diffusion membrane (polycarbonate) was more effective than coating the platinum wire itself, because of the prevention of the homogeneous redox reaction of the interference species with hydrogen peroxide, as well as the additional diffusional resistance to the glucose flux. The glucose levels in serum samples were estimated and the stability of the enzyme electrodes during continuous operation in serum was studied. An enzyme electrode with constant sensitivity of ca. 1 microA/mM and a linear range of up to 15 mM, unaffected by contact with serum, is reported.

Biosensing Techniques↗

A high-affinity reversible protein stain for Western blots.

We describe a reversible staining technique, using MemCode, a reversible protein stain by which proteins can be visualized on nitrocellulose and polyvinylidine fluoride (PVDF) membranes without being permanently fixed to the membrane itself. This allows subsequent immunoblot analysis of the proteins to be performed. The procedure is applicable only to protein blots on nitrocellulose and PVDF membranes. MemCode is a reversible protein stain composed of copper as a part of an organic complex that interacts noncovalently with proteins. MemCode shows rapid protein staining, taking 30s to 1 min for completion. The method is simple and utilizes convenient application conditions that are compatible with the matrix materials and the protein. The stain is more sensitive than any previously described dye-based universal protein staining system. The turquoise-blue-stained protein bands do not fade with time and are easy to photograph compared to those stained with Ponceau S. Absorbance in the blue region of the spectrum offers good properties for photo documentation and avoids interference from common biological chromophores. The stain on the protein is easily reversible in 2 min for nitrocellulose membrane and in 10 min for PVDF membrane with MemCode stain eraser. The stain is compatible with general Western blot detection systems, and membrane treatment with MemCode stain does not interfere with conventional chemiluminescent or chromogenic detection using horseradish peroxide and alkaline phosphatase substrates. The stain is also compatible with N-terminal sequence analysis of proteins.

Blotting, Western↗

Efficacy and compatibility with mass spectrometry of methods for elution of proteins from sodium dodecyl sulfate-polyacrylamide gels and polyvinyldifluoride membranes.

The resolving power of sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) combined with isoelectric focusing in two-dimensional gel electrophoresis has made it one of the most important techniques for resolving complex mixtures, and it is of great importance for proteome mapping projects. As a result of this, methods for postelectrophoretic protein characterization are of great interest as exemplified by in situ protease digestion combined with mass spectrometry (MS), which is the method of choice for identification of proteins. In this study we have developed and compared methods for recovering intact proteins from polyacrylamide gels and electroblotting membranes to define efficient methods compatible with MS. These methods complement in situ digestion protocols and allow determination of the molecular mass of whole proteins separated by SDS-PAGE. Passive elution of proteins from SDS-PAGE gels was efficient only in the presence of SDS, whereas electroelution was achieved using buffers without SDS. Surface-enhanced laser desorption/ionization MS (SELDI-MS) analysis of proteins eluted in the presence of SDS was possible using ion exchange ProteinChip arrays for concentration of sample and removal of SDS. Comparison of different electroblotting methods verified that the different membranes and buffers were equally efficient for transfer of proteins in the range 20-100 kDa. Elution from polyvinyldifluoride membranes was most efficient using either concentrated solutions of trifluoroacetic acid (TFA) or combinations of 8M urea and 1% Triton X-100, 1% Tween 20, or 40% isopropanol. The same result was obtained using nitrocellulose membranes, except that these were incompatible with organic solvent and TFA. Elution by TFA was compatible with matrix-assisted laser desorption/ionization MS (MALDI-MS) but was complicated by a high degree of trifluoroacetylation of the proteins. Alternatively, elution by 8M urea+1% Triton X-100, 1% Tween 20, or 40% isopropanol was compatible with both SELDI-MS and MALDI-MS. Eluted proteins were identified in MS experiments by intact mass determination, by peptide mapping, and by MS/MS analysis.

Acrylic Resins↗

Amperometric biosensor for determining human salivary phosphate.

An amperometric biosensor was constructed for analysis of human salivary phosphate without sample pretreatment. The biosensor was constructed by immobilizing pyruvate oxidase (PyOD) on a screen-printed electrode. The presence of phosphate in the sample causes the enzymatic generation of hydrogen peroxide (H(2)O(2)), which was monitored by a potentiostat and was in proportion to the concentration of human salivary phosphate. The sensor shows response within 2s after the addition of standard solution or sample and has a short recovery time (2 min). The time required for one measurement using this phosphate biosensor was 4 min, which was faster than the time required using a commercial phosphate testing kit (10 min). The sensor has a linear range from 7.5 to 625 microM phosphate with a detection limit of 3.6 microM. A total of 50 salivary samples were collected for the determination of phosphate. A good level of agreement (R(2)=0.9646) was found between a commercial phosphate testing kit and the phosphate sensor. This sensor maintained a high working stability (>85%) after 12h operation and required only a simple operation procedure. The amperometric biosensor using PyOD is a simple and accurate tool for rapid determinations of human salivary phosphate, and it explores the application of biosensors in oral and dental research and diagnosis.

Biosensing Techniques↗

Optimization of a nonradioactive method for consistent and sensitive determination of activated K-ras protein.

Accurate measurement of activity of wild-type K-ras protein is important due to its tumor suppressor action in tissues such as lung. A published method by Taylor and co-workers uses plasmid-containing Escherichia coli cells to produce a glutathione-S-transferase/raf-1 ras binding domain (GST-RBD) fusion protein attached to glutathione beads to isolate activated ras protein. We systematically optimized the method before use on lung tissues. Changing the GST-RBD protein induction temperature from the original 37 to 30 degrees C produced a consistently greater yield of fusion protein. To improve stability of the GST-RBD beads so as to perform large-scale experiments, 0.1% NaN(3) was added. NaN(3)-treated beads retained full affinity for at least 24 days. Sensitivity was improved by using a polyvinylidene difluoride membrane rather than nitrocellulose for immunoblotting. We also compared our GST-RBD beads with two commercial assay kits and found that our beads had both superior sensitivity and reduced variability. In summary, our modification of the GST-RBD affinity method to recover activated K-ras greatly increased the yield of fusion protein, prolonged the useful life of GST-RBD beads to at least 24 days, and enhanced detection sensitivity.

Animals↗

A homogeneous assay for relative affinity of binding proteins using a green fluorescent protein tag and membrane disk.

When the association between a ligand immobilized on a membrane disk and a fluorescence-labeled analyte was monitored with a fluorescent microplate reader, the time-dependent increase in fluorescence intensity of the reaction mixture was observed. A novel assay system for the specific interaction based on this phenomenon was designated the homogeneous assay for fluorescence concentrated on membrane (HAFCOM). In this study, streptococcal protein G (SpG) and glycogen-binding subunit R5 of protein phosphatase 1 (PPP1R5) tagged by green fluorescent protein (GFP) were used as the fluorescence-labeled analytes, and the affinity change caused by various amino acid substitutions was measured with HAFCOM. From the site-directed mutagenesis of SpG and PPP1R5, it was clarified that (i) the association rate constant of the Lys454Pro/Glu456Gln mutant of SpG to goat immunoglobulin G was almost equivalent to that of the wild-type but its dissociation rate constant was about 2.7 times that of the wild-type and (ii) the amino acid substitutions of Phe180 in PPP1R5 reduced glycogen-binding by 30-50%. Since HAFCOM using the GFP-tagged analyte requires no special chemicals and instruments, this system can easily and economically assay the specific interaction between target protein and ligand.

Animals↗

Quantitation of protein on gels and blots by infrared fluorescence of Coomassie blue and Fast Green.

Coomassie blue staining of gels and blots is commonly employed for detection and quantitation of proteins by densitometry. We found that Coomassie blue or Fast Green FCF bound to protein fluoresces in the near infrared. We took advantage of this property to develop a rapid and sensitive method for detection and quantitation of proteins in gels and on blots. The fluorescence response is quantitative for protein content between 10 ng and 20 microg per band or spot. Staining and destaining require only 30 min, and the method is compatible with subsequent immunodetection.

Acrylic Resins↗

De novo proteomic sequencing of a monoclonal antibody raised against OX40 ligand.

De novo sequencing of a full-length monoclonal antibody raised against OX40 ligand is described. Using a combination of overlapping complementary proteolytic and chemical digestions, with analysis by mass spectrometry and Edman degradation, both the heavy and light chains were fully sequenced. Particular attention was paid to those modifications that could be susceptible to degradation in the complementarity determining region and Fc region. An overview of the protocol is described, and suggestions for improvements to aid in such sequencing projects in the future are discussed.

Amino Acid Sequence↗

Development of membrane-based tests for the detection of urinary antigens and antibodies in human toxoplasmosis: preliminary studies in Ghanaian patients.

Two membrane-based ELISA systems were used in detecting Toxoplasma antigens and anti-Toxoplasma antibodies in urine samples collected from 54 ophthalmology (22 suggestive active and 32 suggestive past infection) patients and 26 pregnant women attending obstetrics/gynaecology clinic (OGP), suspected of toxoplasmosis by eye examination, past medical records and questionnaire, respectively, in Ghana from mid-February to April 2002. The antigen detecting ELISA was able to demonstrate antigen in 100% (22/22) ophthalmology (active infection) and 62.5% (20/32) ophthalmology (past infection) patients, and 42% (11/26) of OGP which included 3 that were sero-negative prior to and during this study, giving an overall prevalence of 66.3% (53/80). The urinary antigen positive samples also included 6 that were negative for both the Dye Test (DT) and latex agglutination test (LAT). Antigen was not detected in the urine of 22 normal (sero-negative for antibodies to Toxoplasma) individuals. The membrane-based urinary antibody detecting sandwich ELISA also detected anti-Toxoplasma antibodies in 100% (22/22) of ophthalmology (active infection) and 81.3% (26/32) of ophthalmology (past infection) patients, a total of 89% (48/54); and 80.8% (21/26) of OGP with an overall prevalence of 86.3% (69/80), including 7 ophthalmology patients' samples that were sero-negative for both DT and LAT. Antibody sero-positivity of the samples was determined by DT as 87% (47/54) in ophthalmology patients and 73.1% (19/26) in pregnant women, LAT as 85.2% (46/54) and 65.4% (17/26), and an overall prevalence as 82.5% (66/80) and 78.8% (63/80), respectively. The membrane-based ELISA systems appear promising but need to be investigated further for its efficacy as reliable diagnostic tests.

Adolescent↗

Three-dimensional co-culture of rat hepatocyte spheroids and NIH/3T3 fibroblasts enhances hepatocyte functional maintenance.

Functional maintenance of primary hepatocytes in culture can be improved by several distinct approaches involving optimization of the extracellular matrix microenvironment, media composition and cell-cell interactions, both homotypic and heterotypic. Using a galactose-decorated surface, we have developed a method to combine these two approaches by co-culturing rat primary hepatocyte spheroids with NIH/3T3 mouse fibroblast cells. Spheroids were performed by culturing hepatocytes for 3 days on galactosylated poly(vinylidene difluoride) membrane; NIH/3T3 cells were subsequently seeded and co-cultured with the spheroids. Results showed that although NIH/3T3 cells alone responded poorly to the galactosylated PVDF surface and displayed limited attachment, NIH/3T3 fibroblasts attached to the periphery of the hepatocyte spheroids and proliferated around them. Co-cultured hepatocyte spheroids exhibited significantly higher liver-specific functions as compared to spheroids cultured alone. Albumin secretion level in this co-culture system peaked on day 11, which was 1.8- and 2.9-times higher than the peak expression level in spheroid homo-culture control in serum-free (day 3) and serum-containing media (day 4), respectively. The albumin secretion function was maintained for at least two weeks; it was 5.1 (in serum-free medium) and 17.8 (in serum-containing medium) times higher than spheroid homo-culture on day 13. Similarly, the co-culture system also expressed approximately 5.5- and 3.1-times higher 3-methylcholanthrene-induced cytochrome P450 enzymatic activity on day 14 as compared to the homo-culture control in serum-free and serum-containing medium, respectively. In conclusion, this unique co-culture system demonstrated the synergistic roles of homotypic cell-cell interaction, heterotypic cell-cell interaction, cell-substrate interaction and soluble stimuli in hepatocyte functional maintenance.

Animals↗

LRP 1 B functions as a receptor for Pseudomonas exotoxin.

Pseudomonas aeruginosa is an opportunistic pathogen that produces several virulence factors, among them Pseudomonas Exotoxin A (PE). Previously, low-density lipoprotein receptor-related protein 1 (LRP 1) was shown to be the primary receptor for PE. In this report, we show that a close family member, LRP 1B, can also function as a receptor.

Animals↗

Electrochemistry of cytochrome c incorporated in Langmuir-Blodgett films of Nafion and Eastman AQ 55.

Ultrathin films of Nafion and Eastman-AQ 55 loaded with cytochrome c (cyt c) were obtained and transferred on indium tin oxide (ITO) electrodes via the Langmuir-Blodgett (LB) technique. The pressure-area isotherms for mixed ionomer-protein films indicate that the miscibility of cyt c in the interfacial layer is better for Nafion than for AQ 55. Interestingly, these composite films maintain the electroactivity of cyt c without requiring the addition of promoters or mediators. Both for AQ 55-cyt c and Nafion-cyt c films, the half-wave potential for the reversible reduction of ferricytochrome c corresponds to the value expected for the weakly adsorbed protein. The modified electrodes show electrocatalytic reaction with ascorbate anion. Comparison with previous literature reports indicate that for Nafion the LB coating procedure is unique in keeping the electroactivity of cyt c.

Cytochrome c Group↗

Characterization of natural chitosan membranes from the carapace of the soldier crab Mictyris brevidactylus and its application to immobilize glucose oxidase in amperometric flow-injection biosensing system.

This study investigated characteristics of a chitosan membrane from the carapace of the soldier crab Mictyris brevidactylus intended to construct an amperometric biosensor. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used in this study to characterize these chitosan membranes intended for constructing enzymatic biosensors. Chitosan membranes suffering various durations (>10 min) of deacetylation had small charge-transfer resistances (<7.88 kohms) but large double-layer capacitances (>0.55 microF). They were found in EIS where both the solution resistance and Warburg impedance upon electrode interface were almost independent of the durations and degree of deacetylation. The degree of deacetylation and the thickness of chitosan membranes were also determined. Membrane thickness was slightly dependent with the duration but degree of deacetylation was slightly dependent on the duration. Chitosan membranes with various thicknesses suffered various durations of deacetylation, but this did not influence their electrochemical characteristics. The chitinous membrane was covalently immobilized with glucose oxidase (EC 1.3.4.3) and then attached onto the platinum electrode of a homemade amperometric flow cell. Sensor signal was linearly related to glucose concentration (r=0.999 for glucose up to 1.0 mM). The system was sensitive (S/N>5 for 10 microM glucose) and reproducible (CV<1.3% for 50 microM glucose, n=5).

Acetylation↗

Glucose oxidase/colloidal gold nanoparticles immobilized in Nafion film on glassy carbon electrode: Direct electron transfer and electrocatalysis.

The direct electron transfer of glucose oxidase (GOD) was achieved based on the immobilization of GOD/colloidal gold nanoparticles on a glassy carbon electrode by a Nafion film. The immobilized GOD displayed a pair of well-defined and nearly reversible redox peaks with a formal potential (Eo ') of -0.434 V in 0.1 M pH 7.0 phosphate buffer solution and the response showed a surface-controlled electrode process. The dependence of Eo ' on solution pH indicated that the direct electron transfer reaction of GOD was a two-electron-transfer coupled with a two-proton-transfer reaction process. The experimental results also demonstrated that the immobilized GOD retained its electrocatalytic activity for the oxidation of glucose. So the resulting modified electrode can be used as a biosensor for detecting glucose.

Biosensing Techniques↗

Ion-exchange voltammetry of dopamine at Nafion-coated glassy carbon electrodes: quantitative features of ion-exchange partition and reassessment on the oxidation mechanism of dopamine in the presence of excess ascorbic acid.

The incorporation/exclusion features of dopamine (DA), ascorbic acid (AA) and uric acid (UA) are evaluated for Nafion (NA)-coated glassy carbon electrodes (GCE) of different thicknesses. The ion-exchange partition of DA(+) between the NA film and the sodium phosphate electrolyte is evaluated by determining the partition coefficient (k(D)) and the apparent diffusion coefficient (D(app)) in thick NA films which were 401 and 1.5 x 10(-9) cm(2) s(-1), respectively. The solution diffusion coefficient was found to be 6.0 x 10(-6) cm(2) s(-1). Also, the effect of NA loading and of the voltammetric timescale on DA voltammetry in the presence of excess AA is assessed, at physiologic like conditions. It is demonstrated that, although AA is excluded at the NA coating, a catalytic regeneration of DA, induced by AA, occurs at the interface NA film/electrolyte resulting from the diffusion of the o-quinone product of DA oxidation from the electrode surface to that interface. The interference of AA in the voltammetric signal of DA is eliminated using 18 microg mm(-2) NA films and v> or =0.5 V s(-1). Therefore, fast, selective and sensitive voltammetric analysis of DA at concentrations<100 microM in the presence of excess AA, e.g., 1 mM is achieved.

Adsorption↗

Nitric oxide sensor based on carbon fiber covered with nickel porphyrin layer deposited using optimized electropolymerization procedure.

Electropolymerization regime of meso-tetrakis(3-methoxy-4-hydroxyphenyl) porphyrin is optimized to yield films possessing both electrocatalytical and permselective properties towards nitric oxide oxidation. The sensor composed of electrochemically oxidized carbon fiber, covered solely with nickel porphyrin derivative layer electropolymerized using our method, is characterized by high selectivity towards nitrite (1:600), ascorbate (1:8000) and dopamine (>1:80), determined by constant potential amperometry at 830 mV (vs. Ag/AgCl). Selectivity for ascorbate and dopamine as well as detection limit for NO (1.5 nM at S/N=3) is 5-10 times better than parameters usually reported for Nafion coated porphyrinic sensors. Nafion coating can further enhance selectivity properties as well as aids to the stability of the sensors' responses.

Ascorbic Acid↗

Gentamicin supplementation of polyvinylidenfluoride mesh materials for infection prophylaxis.

Hernia repair evolved from pure tissue repair to mesh repair due to decreased recurrence rates. However, concern exists about mesh-related infections occurring even several years after initial operation. Therefore, a polyvinylidenfluoride (PVDF) mesh material was constructed and surface modified by plasma-induced graft polymerization of acrylic acid (PVDF+PAAc). Antimicrobial treatment was sought by binding of gentamicin (PVDF+PAAc+Gentamicin). In vitro efficacy and cytotoxicity was measured by agar diffusion test, L929 cytotoxicity testing and by analyzing the amount of gentamicin release from the mesh surface. In vivo biocompatibility was evaluated in 45 Sprague-Dawley rats. 7, 21 and 90 days after mesh implantation the amount of inflammatory and connective tissue as well as the percentage of proliferating (Ki67) and apoptotic cells (TUNEL) were analyzed at the perifilamentary region. Agar diffusion tests showed sufficient local antimicrobiotic effects against the bacteria tested after 24h of incubation. No signs of cytotoxicity could be identified by L929 testing. Furthermore, surface modification did not affect the in vivo biocompatibility. At the end of the observation period, no significant differences were found for the perifilamentary amount of inflammatory cells and connective tissue and the percentage of Ki67 and TUNEL positive stained cells. The presented data confirm that an antibiotic surface modification of PVDF mesh samples is feasible. By analyzing cytotoxicity in vitro as well as biocompatibility in vivo no side effects were observed.

Animals↗