PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Monte Carlo Method”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

A chromatin switch.

Cellular and molecular biological approaches that study eukaryotic gene regulation have led to separate models which describe structure and mechanism with differing precision. Using principles of combinatorial and cooperative interactions inherent in both models, we have extended concepts derived from a "genetic switch" for prokaryotes to a chromatin switch for eukaryotes composed of DNA, transactivators, nucleosomes and the nuclear matrix. We present a consensus model for gene regulation that uses a simple Monte Carlo method for simulating condensation and extension of chromatin. Such a chromatin switch can be modulated by known biochemical and molecular modifications, and the transactivator binding sites or enhancers within DNA domains can be organized into a hierarchy to control cell cycling and differentiation.

Animals↗

On the equivalence of propane-based tissue-equivalent gas and liquid water with respect to the ionisation-yield formation by electrons and alpha-particles.

One encouraging way, at present, to put the investigation of ionisation-yield formation in sub-cellular structures or, at least, in nanometric volumes of liquid water on an experimental basis is the use of highly sophisticated counters filled with gases at low operating pressure to simulate target volumes a few nm in diameter at unit density. To check the validity of such measurements, the ionisation-yield formation by electrons and alpha particles in liquid water was simulated using the Monte Carlo method and compared with that produced in propane-based tissue-equivalent gas (composition by volume: 55% C3H8, 39.6% CO2, 5.4% N2). After a short summary of the most important physical aspects of ionisation cluster formation, new results are presented and discussed from the point of view of radiation physics and radiation biology.

Alpha Particles↗

Modeling film-coat non-uniformity in polymer coated pellets: a stochastic approach.

The objective of the present study is to include coating thickness non-uniformity in the development of a drug release model using coated ion-exchange pellets through the use of stochastic approaches. Drug release from ion-exchange resins was described using a Nernst-Plank model. Complexes of a model drug (dextromethorphan) and Dowex 50WX4-200 were prepared using a modified batch method and coated with Kollicoat SR 30D polymer. The deterministic model, validated using experimental drug release profiles for different coating thicknesses at 0%, 10%, 15%, 20% (w/w), was in agreement with the experimental data with a maximum root mean square error (RMSE) of 2.4%. An arbitrary Lagrangian-Eulerian approach was pursued to develop models of spherical pellets with non-uniform coating thicknesses. The Monte Carlo method was used to simulate the effect of the level of coating deformity on the cumulative drug release profile. Considering the co-existence of equal percentages of deformed and undeformed pellets in a batch, the cumulative release profile can vary by approximately +/-6% as a result of coating non-uniformity. The release profile obtained for a model of an arbitrary pellet with an actual non-uniform coating profile was in good agreement with the average release profile for the models of the theoretical randomly deformed pellets. The developed mathematical model is a useful tool to evaluate and predict release profiles of polymer coated ion-exchange resin complexes.

Algorithms↗

Analysis of error propagation from NMR-derived internuclear distances into molecular structure of cyclo-pro-gly.

Analytical expressions have been derived that translate uncertainties in distance constraints (obtained from NMR investigations) into uncertainties in atom positions in the maximum likelihood (ML) structure consistent with these inputs. As a test of this approach, a comparison was made between test structures reconstructed by the new ML approach, which yields a single structure and a covariance matrix for coordinates, and those reconstructed by metric matrix distance-geometry (MMDG), which yields a family of structures that sample uncertainty space. The test structures used were 560 polyhedra, with edges of arbitrary length containing up to 50 vertices, and one polyhedron, with 100 vertices; randomized distance constraints generated from these structures were used in reconstructing the polyhedra. The uncertainties derived from the two methods showed excellent agreement, and the correlation improved, as expected, with increasingly larger numbers of MMDG structures. This agreement supports the validity of the rapid analytical ML approach, which requires the calculation of only a single structure. As a second test of the ML method, the approach was applied to the determination of uncertainties in the structure of a cyclic dipeptide, cyclo(DL-Pro-Gly) (cPG), derived from NMR cross-relaxation data. The input data were interproton distances calculated from NOEs measured for a solution of the peptide in 2:1 DMSO:H2O at -40 degreesC (so as to yield large negative NOEs). In order to evaluate effects of the quality of the input spectral parameters on the precision of the resulting NMR structure, information from the covalent geometry of cPG was not used in the structure calculations. Results obtained from the analytical ML approach compared favorably with those from the much slower random-walk variant of the Monte Carlo method applied to the same input data. As a third test, the ML approach was used with synthetic structural constraints for a small protein; the results indicate that it will be feasible to use this rapid method to translate uncertainties associated with a given set of distance restraints into uncertainties in atom positions in larger molecules.

Dipeptides↗

Monte Carlo simulation of intrinsic count rate performance of a scintillation camera for diagnostic images.

This paper describes Monte Carlo simulation of intrinsic count rate performance of a scintillation gamma camera. MCNP Monte Carlo code was employed to calculate pulse height spectrum and detector efficiency. A custom code written in Fortran language was then developed to simulate, by Monte Carlo method, the distortion in pulse height spectrum due to the pile-up effect for paralyzable and nonparalyzable systems. The results of the simulations, compared with the experimental measurement of count rate performance, showed a good agreement between the two different approaches.

Algorithms↗

Monte Carlo simulation of the dose distribution around 125I seeds.

The Monte Carlo method was used to investigate dose distributions around the 3M Company model 6701 and model 6702 125I brachytherapy seeds. The transverse axis dose distributions of the two seed models were found to be nearly identical, but the longitudinal axis dose distributions differed significantly. Seed design influences upon dose distributions also were investigated.

Humans↗

A comparison of the analysis of covariance (ANCOVA) and range-based approaches for assessing batch-to-batch variability of the stability of pharmaceutical products.

Stability data were generated by the Monte Carlo method, and batch-to-batch variability was evaluated by analysis of differences in slope and intercept according to the analysis of covariance (ANCOVA) approach recommended in the FDA Guidance. Using the same generated data, batch-to-batch variability was also evaluated by assessing the equivalence of shelf lives estimated for individual batches based on the range (Range-based approach) in order to compare the ability of the two approaches to detect stability differences among batches. The results of the study indicated that the Range-based approach can detect a 30% difference in the slope of degradation curves among batches with a similar beta error as the ANCOVA approach, provided that degradation data are obtained with assay errors below 0.5. The range-based approach appears to be useful as an alternative method to ANCOVA, if it is modified such that the variance of estimates is taken into account.

Analysis of Variance↗

A Monte Carlo pharmacophore generation procedure: application to the human PAF receptor.

A novel pharmacophore definition procedure is described, which uses a Monte Carlo method to superimpose molecules. Pharmacophore space is searched by a technique similar to high temperature annealing. Subsequent refinement of candidate pharmacophores by energy minimization produces low-energy conformations that may be involved in receptor binding. The method has been applied to compounds that bind to the human platelet-activating factor (PAF) receptor. Alternative binding site models for the PAF receptor are presented and discussed.

Binding Sites↗

Generalized dual-energy-window scatter compensation in spatially varying media for SPECT.

The detection of scattered photons in the photopeak energy window hinders accurate activity estimation in single-photon-emission computed tomography (SPECT). To compensate for photons scattered in spatially varying media, a framework for generalized dual-energy-window scatter subtraction has been developed. Generalized scatter subtraction factors are introduced, and these factors are decomposed into terms dependent on the uniform (average) and spatially varying components of the source activity distribution. The variation of these factors with projection pixel location and gamma camera position is analysed for a simulated myocardial perfusion study with a 99Tc(m) source radionuclide and a non-uniform thorax model. Monte Carlo methods are used to model photon transport and detection. The application of pixel-dependent scatter subtraction factors for scatter compensation is evaluated in an image reconstruction experiment for this simulated myocardial perfusion study. Generalized matrix inverses with noise-dependent regularization are used for image reconstruction. For this simulation, use of a pixel-dependent scatter subtraction factor and a constant scatter subtraction factor are effective for scatter compensation. Activity estimates within the left ventricular myocardium for these two methods are practically the same as those obtained from image reconstructions where the detection of Compton-scattered photons is included in the system matrix.

Heart Ventricles↗

Usefulness of Bayesian graphical models for early prediction of disease progression in multiple sclerosis.

Previous studies of possible prognostic indicators for multiple sclerosis have been based on "classic" Cox's proportional hazards regression model, as well as on equivalent or simpler approaches, restricting their attention to variables measured either at disease onset or at a few points during follow-up. The aim of our study was to analyse the risk of reaching secondary progression in MS patients with a relapsing-remitting initial course, using two different statistical approaches: a Cox's proportional-hazards model and a Bayesian latent-variable model with Markov chain Monte Carlo methods of computation. In comparison with a standard statistical approach, our model is advantageous because, exploiting all the information gleaned from the patient as it is gradually made available, it is capable to detect even small prognostic effects.

Age of Onset↗

Spatial heterogeneity of the risk of BSE in France following the ban of meat and bone meal in cattle feed.

In France, meat-and-bone meal (MBM) has been prohibited for cattle feeding since 1990, but bovine spongiform encephalopathy (BSE) cases, called 'NAIF', appeared in animals born after this feed ban. Furthermore, in 1996 a new measure was taken: removal of cadavers and specified risk materials (SRM) from the processing of MBM dedicated to animal feed. Nevertheless, BSE cases (called 'super-NAIF') appeared in cattle born after this measure was in force. We analysed the spatial distribution of 445 'NAIF' and 58 'super-NAIF' cases detected in France from July 1, 2001 to July 31, 2003. The detection of BSE was based both on the mandatory reporting system (MRS) and the systematic test screening of cattle at the abattoir and at the fallen-animal plant with rapid tests. The background population was based on the adult-cow census. The disease mapping of the BSE risk was based on the standardised incidence ratio (stochastic Poisson process). A spatial component, which takes into account the spatial dependence between the geographical units by a notion of adjacency was used to eliminate the over-dispersion in the risk assessment. The geographical units were defined by hexagons with a side of 23km (France had 1264 hexagons). The parameters were estimated by a Metropolis Gibbs sampling algorithm using the Markov-chain Monte Carlo methods. The BSE cases were not randomly distributed. Furthermore, the areas at risk for the 'super-NAIF' matched part of the areas at risk for the 'NAIF' cases-which suggests that it might be a common source of contamination.

Animal Feed↗

Patterns of microsatellite variability in the Drosophila melanogaster complex.

Forty-seven microsatellite loci were amplified in Drosophila melanogaster, Drosophila simulans, Drosophila mauritiana and Drosophila sechellia. The two cosmopolitan species D. melanogaster and D. simulans were found to be the most variable ones, followed by D. mauritiana and D. sechellia. A model based clustering algorithm was applied to the population samples of D. melanogaster, D. simulans and D. sechellia. No evidence for population substructure was detected within species--most likely due to insufficient power. A Markov chain Monte Carlo method developed for demographic inference based on microsatellites provided unambiguous evidence for population contraction in D. melanogaster, D. simulans and D. sechellia, despite that the D. melanogaster and D. simulans population samples were of non-African origin and represented recently expanded populations.

Africa↗

Functional architecture of eye position gain fields in visual association cortex of behaving monkey.

In the behaving monkey, inferior parietal lobe cortical neurons combine visual information with eye position signals. However, an organized topographic map of these neurons' properties has never been demonstrated. Intrinsic optical imaging revealed a functional architecture for the effect of eye position on the visual response to radial optic flow. The map was distributed across two subdivisions of the inferior parietal lobule, area 7a and the dorsal prelunate area, DP. Area 7a contains a representation of the lower eye position gain fields while area DP represents the upper eye position gain fields. Horizontal eye position is represented orthogonal to the vertical eye position across the medial lateral extents of the cortices. Similar topographies were found in three hemispheres of two monkeys; the horizontal and vertical gain field representations were not isotropic with a greater modulation found with the vertical. Monte Carlo methods demonstrated the significance of the maps, and they were verified in part using multiunit recordings. The novel topographic organization of this association cortex area provides a substrate for constructing representations of surrounding space for perception and the guidance of motor behaviors.

Animals↗

Study of the methyl ester distribution in pectin with endo-polygalacturonase and high-performance size-exclusion chromatography.

A method was developed that enables the study of the methyl ester distribution in the polymers of pectin on a molecular level. Endo-polygalacturonase was used to extensively degrade three 70% methyl esterified pectins. The molecular weight distribution of the non- and enzymatically degraded pectins was determined with high-performance size-exclusion chromatography. Next, the molecular weight distribution was converted into a degree of polymerization distribution of galacturonan fragments. Monte Carlo methods were employed for the reconstruction of the parental polymers from their enzymatic degradation products. The results for the random methyl esterified pectin revealed that the enzyme-degradable sites were indeed randomly distributed, which confirmed the correctness of the procedure developed. The two other pectins studied differed greatly in the amount of non-, low-, and high-esterified regions present in the reconstructed pectic molecules of a given molecular mass. That the approach developed is able to reveal such detailed information makes it unique. The information on the fragmental composition of pectic polymers obtained is an important addition to the study of the methyl ester distribution and the functional properties of pectin.

Chromatography, High Pressure Liquid↗

Item response models for joint analysis of quality of life and survival.

A complication when assessing quality of life data longitudinally is that in many trials a substantial percentage of patients die before completing all of the assessments. Furthermore, a patient's risk of dying might be predicted by his current quality of life. This suggests jointly modelling quality of life and survival, and using this combined information to summarize the outcome. The aim of this paper is to address the complicated issues, such as death, present in analysing multiple-item ordinal quality of life data in clinical trials while recognizing the psychometric properties of the quality of life instrument being used. This is done by combining an item response model and Cox's proportional hazard model, where a latent variable process for quality of life determines the probability of selecting various options on quality of life items, and also serves as a time-dependent covariate in the survival model. We accomplish this by using Markov chain Monte Carlo methods to obtain parameter estimates. Then we compute a summary measure, area-under-QOL curve, to compare the efficacy of the treatments. The methods are illustrated with analysis of data from the Vesnarinone trial of patients with severe heart failure, in which quality of life was assessed with the Minnesota Living with Heart Failure Questionnaire.

Area Under Curve↗

Computer simulation of geometry and hemodynamics of canine pulmonary arteries.

Assuming that along the pulmonary arteries, mathematical expectations of branching are equal to matrix (Ei,j; i: parent branch class, j: daughter branch class number), we made computer drafts of patterns of pulmonary arterial branching trees from the published data of canine pulmonary arterial casts with the "Monte Carlo methods" by FORTRAN, calculating from these data, the numbers of branches, size and resistance of the trees. We also analyzed blood flow distribution in a pulmonary branch according to the pathlength from the entrance of the tree. The graphics of the trees were similar to the original arterial casts, and numbers of the branches were nearly the same as the previous reported values. Calculated resistance was reasonable. The rate of blood flow per unit vessel in the short pathlength group was calculated as 1.5 times that of the long pathlength group of the same diameter. We believe that our method of describing the branching pattern matrix (Ei,j) provides a reasonable simulation of complex branching patterns such as pulmonary arteries and a useful means to analyze local hemodynamics.

Animals↗

Comparative evaluation of two models for estimating sample sizes for tests on trends across repeated measurements.

Two equations for calculating sample sizes that are required for power in testing differences in rates of change in repeated measurement designs have been presented by different authors. One equation provides support for the conclusion that increased frequency of measurements across a treatment period of fixed duration enhances power of the tests. The other equation supports the counterintuitive conclusion that increased frequency of measurements actually tends to decrease power in the presence of realistic serial dependencies in the data. Monte Carlo methods confirm that the equation providing support for the latter conclusion is accurate, whereas the alternative equation tends to underestimate sample sizes required for power in testing differences in slopes of regression lines fitted to changes in the repeated measurements across time when symmetry is absent from the covariance structure.

Clinical Trials as Topic↗

Shielding analysis of the Microtron MT-25 bunker using the MCNP-4C code and NCRP Report 51.

A cyclic electron accelerator Microtron MT-25 will be installed in Havana, Cuba. Electrons, neutrons and gamma radiation up to 25 MeV can be produced in the MT-25. A detailed shielding analysis for the bunker is carried out using two ways: the NCRP-51 Report and the Monte Carlo Method (MCNP-4C Code). The walls and ceiling thicknesses are estimated with dose constraints of 0.5 and 20 mSv y(-1), respectively, and an area occupancy factor of 1/16. Both results are compared and a preliminary bunker design is shown.

Electrons↗